• Title/Summary/Keyword: interaction with small groups

Search Result 84, Processing Time 0.026 seconds

PHealth Service Deployment Methodology: A Case Study

  • Paggetti, Cristiano;Rugnone, Alberto;Tamburini, Elena;Nugent, Chris
    • Journal of Computing Science and Engineering
    • /
    • v.6 no.1
    • /
    • pp.60-66
    • /
    • 2012
  • It has been proved that information and communication technology (ICT) solutions for personalized health (PHealth) and ambient assisted living (AAL) can support people in their daily life activities. Several solutions have been demonstrated to empower different levels of services through seamless data acquisition and specific users' interaction modalities. Usually services usability and accessibility are handled in the design process and are validated with small users' groups. Moreover, while service design and systems development have been extensively described in literature, service deployment methodologies are not properly addressed and documented. Proper reference guidelines are also missing. The most common methodologies like unified process (UP) or ICONX can cover only the design and the development of PHealth services without a clear description on the following phases such as deployment, service provision and maintenance. These phases present several risks to be taken into account right from the beginning of the implementation of PHealth or AAL services. This paper focuses on the description of a structured methodology to deploy PHealth services and how this process can be supported by integrated software routines and adapting the UP framework in particular the "Transition phase."

Effect of Morin on the Pharmacokinetics of Nifedipine in Rats (흰쥐에서 모린이 니페디핀의 약물동태에 미치는 영향)

  • Lee, Chong-Ki;Choi, Jun-Shik
    • YAKHAK HOEJI
    • /
    • v.51 no.3
    • /
    • pp.169-173
    • /
    • 2007
  • The aim of this study was to investigate the effect of morin on the pharmacokinetics of nifedipine in rats. The pharmacokinetic parameters of nifedipine were measured after the oral administration of nifedipine (5 mg/kg) in the presence or absence of morin (1.5, 7.5 and 15 mg/kg, respectively). Compared to the control groups, the presence of 7.5 mg/kg and 15 mg/kg of morin significantly (p<0.05) increased the area under the plasma concentration-time curve (AUC) of nifedipine by 48.5${\sim}$68.2%, and the peak concentration (C$_{max}$,) of nifedipine by 59.9~84.2%. The absolute bioavailability(AB%) of nifedipine was significantly (p<0.05) increased by 21.5${\sim}$24.5% compared to the control (14.5%). While there was no significant change in the time to reach the peak plasma concentration (T$_{max}$) and the terminal half-life (T$_{1/2}$) of nifedipine in the presence of morin. It might be suggested that morin altered disposition of nifedipine by inhibition of both the first-pass metabolism and p-glycoprotein (P-gp) efflux pump in the small intestine of rats. In conclusion, the presence of morin significantly enhanced the oral bioavailability of nifedipine, suggesting that concurrent use of morin or morin-containing dietary supplement with nifedipine should require close monitoring for potential drug interaction.

A Study on the Structure and Thermal Property of $Co^{2+}$-Exchanged Zeolite A

  • Jong-Yul Park
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.3
    • /
    • pp.265-270
    • /
    • 1991
  • Theoretical calculations on the stabilization energies of framework atoms in hydrolyses Co(Ⅱ )-exchanged zeolite A were made using some potential energy functions and optimization program. The protons which are produced by hydrolysis of $[Co(H_2O)_n]^{2+}$ ion in large cavity showed a tendency to attack the framework oxygen atom O(1) preferentially, and the oxygen atom O(4) within OH- ion was coordinated at Al atom. The weakness of bonds between T(Si, Al) and oxygen by attack of proton and too large coordination number around small aluminum atom will make the framework of Co(Ⅱ)-exchanged zeolite A more unstable. The stabilization energy of $Co_4Na_4$-A framework (- 361.57 kcal/mol) was less than that of thermally stable zeolite A($Na_{12-}$A: - 419.68 kcal/mol) and greater than that of extremely unstable Ba(Ⅱ)-exchanged zeolite A($Ba_{6-}$A: - 324.01 kcal/mol). All the data of powder X-ray diffraction, infrared and Raman spectroscopy of Co(Ⅱ)-exchanged zeolite A showed the evidence of instability of its framework in agreement with the theoretical calculation. Three different groups of water molecules are found in hydrated Co(Ⅱ )-exchanged zeolite A; W(Ⅰ) group of water molecules having only hydrogen-bonds, W(Ⅱ) group water coordinated to $Na^+$ ion, ans W(Ⅲ) group water coordinated to Co(Ⅱ) ion. The averaged interaction energy of each water group shows the decreasing order of W(Ⅲ)>W(Ⅱ)>W(Ⅰ).

Effect of Nutrition and Exercise Modification Therapy on Metabolism Efficiency of Middle-aged Women Through Convergence (융복합을 활용한 영양과 운동중재요법이 중년여성의 대사 효율성에 미치는 영향)

  • Chea, Su-In;Nam, Sang-Nam;Kim, In-Dong
    • Journal of Digital Convergence
    • /
    • v.13 no.5
    • /
    • pp.393-400
    • /
    • 2015
  • The purpose of this study to examine the effect of intermittent fasting and resistance exercise on sex hormone and glucose metabolism of middle-aged women for 12 weeks. The two groups classified that one group(EG) was done intermittent fasting and resistance exercise both, the other group(CG) was controled. The group of EG was applied doing intermittent fasting 1 time for 24 hours a week, and doing resistance exercise 3 times for 60 minutes a week. The intensity of the exercise was 60%. Each measurement variable measured before and after 12 weeks to investigate the effect. During this study got the result with this step. First, EG have shown small interaction with sex hormone. Second, EG have shown small interaction with resistance exercise. Therefore, this study give us positive result to effect of intermittent fasting and resistance exercise on sex hormone and glucose of middle-aged women for 12 weeks. However, it has limitation to verify effect of intermittent fasting and resistance exercise.

Optimization of Dual Layer Phoswich Detector for Small Animal PET using Monte Carlo Simulation

  • Y.H. Chung;Park, Y.;G. Cho;Y.S. Choe;Lee, K.H.;Kim, S.E.;Kim, B.T.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.44-44
    • /
    • 2003
  • As a basic measurement tool in the areas of animal models of human disease, gene expression and therapy, and drug discovery and development, small animal PET imaging is being used increasingly. An ideal small animal PET should have high sensitivity and high and uniform resolution across the field of view to achieve high image quality. However, the combination of long narrow pixellated crystal array and small ring diameter of small animal PET leads to the degradation of spatial resolution for the source located at off center. This degradation of resolution can be improved by determining the depth of interaction (DOI) in the crystal and by taking into account the information in sorting the coincident events. Among a number of 001 identification schemes, dual layer phsowich detector has been widely investigated by many research groups due to its practicability and effectiveness on extracting DOI information. However, the effects of each crystal length composing dual layer phoswich detector on DOI measurements and image qualities were not fully characterized. In order to minimize the DOI effect, the length of each layer of phoswich detector should be optimized. The aim of this study was to perform simulations using a simulation tool, GATE to design the optimum lengths of crystals composing a dual layer phoswich detector. The simulated small PET system employed LSO front layer LuYAP back layer phoswich detector modules and the module consisted of 8${\times}$8 arrays of dual layer crystals with 2 mm ${\times}$ 2 mm sensitive area coupled to a Hamamatsu R7600 00 M64 PSPMT. Sensitivities and variation of radial resolutions were simulated by varying the length of LSO front layer from 0 to 10 mm while the total length (LSO + LuYAP) was fixed to 20 mm for 10 cm diameter ring scanner. The radial resolution uniformity was markedly improved by using DOI information. There existed the optimal lengths of crystal layers to minimize the variation of radial resolutions. In 10 cm ring scanner configuration, the radial resolution was kept below 3.4 mm over 8 cm FOV while the sensitivity was higher than 7.4% for LSO 5 mm : LuYAP 15 mm phoswich detector. In this study, the optimal length of dual layer phoswich detector was derived to achieve high and uniform radial resolution.

  • PDF

The Economic Analysis of Notional and Global Interest Politics for International Environmental Standards

  • Hwang, Uk
    • Journal of Environmental Policy
    • /
    • v.6 no.4
    • /
    • pp.103-127
    • /
    • 2007
  • This study presents the political economics models to explore the political landscape of special interest groups influencing the government's decision making process for implementing international environmental standard. Starting with the popular menu-auction types of lobbying frameworks in the literature, the study extends its scope of research to multi-principal and multi-agency based international interest group politics and its hybrid case in order to bring the interaction of the relevant interest politics to the fore. Within a specific factor model of international trade between 2 small open economies, we compare the political equilibrium environmental standards in different institutional frameworks which can be feasible in the sense of recently growing role of environmental interest group. Although the conventional finding suggests that cooperative bargaining between the two countries can attain the globally optimal level of the standard, the paper rather explains that the cooperation between the national interest groups and the hybrid case also generate the stricter standard then national interest politics usually do.

  • PDF

SURFACE ANALYSES OF TITANIUM SUBSTRATE MODIFIED BY ANODIZATION AND NANOSCALE Ca-P DEPOSITION

  • Lee, Joung-Min;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.795-804
    • /
    • 2007
  • Statement of problem. Nano-scale calcium-phosphate coating on the anodizing titanium surface using ion beam-assisted deposition (IBAD) has been recently introduced to improve the early osseointegration. However, not much is known about their surface characteristics that have influence on tissue-implant interaction. Purpose. This study was aimed to investigate microtopography, surface roughness, surface composition, and wettability of the titanium surface modified by the anodic oxidation and calcium phosphate coating using IBAD. Material and methods. Commercially pure titanium disks were used as substrates. The experiment was composed of four groups. Group MA surfaces represented machined surface. Group AN was anodized surface. Group CaP/AN was anodic oxidized and calcium phosphate coated surfaces. Group SLA surfaces were sandblasted and acid etched surfaces. The prepared titanium discs were examined as follows. The surface morphology of the discs was examined using SEM. The surface roughness was measured by a confocal laser scanning microscope. Phase components were analyzed using thin-film x-ray diffraction. Wettability analyses were performed by contact angle measurement with distilled water, formamide, bromonaphtalene and surface free energy calculation. Results. (1) The four groups showed specific microtopography respectively. Anodized and calcium phosphate coated specimens showed multiple micropores and tiny homogeneously distributed crystalline particles. (2) The order of surface roughness values were, from the lowest to the highest, machined group, anodized group, anodized and calcium phosphate deposited group, and sandblasted and acid etched group. (3) Anodized and calcium phosphate deposited group was found to have titanium and titanium anatase oxides and exhibited calcium phosphorous crystalline structures. (4) Surface wettability was increased in the order of calcium phosphate deposited group, machined group, anodized group, sandblasted and acid etched group. Conclusion. After ion beam-assisted deposition on anodized titanium, the microporous structure remained on the surface and many small calcium phosphorous crystals were formed on the porous surface. Nanoscale calcium phosphorous deposition induced roughness on the microporous surface but hydrophobicity was increased.

Exploring the Patterns of Group model Development about Blood Flow in the Heart and Reasoning Process by Small Group Interaction (소집단 상호작용에 따른 심장 내 혈액 흐름에 대한 소집단 모델 발달 유형과 추론 과정 탐색)

  • Lee, Shinyoung;Kim, Chan-Jong;Choe, Seung-Urn;Yoo, Junehee;Park, HyunJu;Kang, Eunhee;Kim, Heui-Baik
    • Journal of The Korean Association For Science Education
    • /
    • v.32 no.5
    • /
    • pp.805-822
    • /
    • 2012
  • The purpose of this study was to explore the patterns of group model development about blood flow in the heart and reasoning process by small group interaction. The subjects were 14, 8th graders in a Science Gifted Center. The group discussion was made possible by using triggering questions that can be answered based on experiences of hands-on activities such as a siphon pump analogy model activity and a dissection of pigs' hearts. Despite participating in same activities, the groups showed different model development patterns: unchanged, persuasive, and elaborated. Due to the critical revising, the group's explanatory model was elaborated and developed in the added and elaborated pattern. As critical revising is a core element of the developing model, it is important to promote a group interaction so that students become critical and receptive. The pedagogical analogy model and conflict situation enabled students to present elaborated reasoning. The Inquiry activity with the pedagogical analogy model promote students' spontaneous reasoning in relation to direct experience. Therefore offering a pedagogical analogy model will help students evaluate, revise and develop their models of concerned phenomena in science classroom. Conflict situation by rebuttal enable students to justify more solid and elaborate a model close to the target model. Therefore, teachers need to facilitate a group atmosphere for spontaneous conflict situation.

Effects of Alpha-galactosidase Supplementation to Corn-soybean Meal Diets on Nutrient Utilization, Performance, Serum Indices and Organ Weight in Broilers

  • Wang, C.L.;Lu, W.Q.;Li, Defa;Xing, J.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.12
    • /
    • pp.1761-1768
    • /
    • 2005
  • Effects of alpha-galactosidase (GAL) on broiler corn-soybean meal diet was investigated. In experiment 1, sixty cockerels were allocated to five groups, including three enzyme treatments (GAL added at 0, 500, and 1,000 mg/kg diet), a nitrogen-free diet group and a fast group. The true nitrogen-corrected ME (TME$_n$) and true amino acid availability were determined. In experiment 2, 324 day-old chicks were used in a 2${\times}$3 factorial design consisting of two energy contents (high and low) and three GAL levels (0, 250, and 500 mg/kg). Three feeding phases, comprising 0-21 d, 22-35 d and 36-48 d, were involved. GAL addition improved TME$_n$ and the availability of methionine and cystine (p<0.05). The apparent ME (AME) or nitrogen-corrected AME (AME$_n$) and digestibility of dry matter, organic matter, calcium, and phosphorus were improved significantly on d 21, so was crude protein and an interaction of energy and GAL on AME$_n$ (p<0.05) was found on d 35. However, daily intake and daily gain were significantly improved with GAL addition (p<0.05) during 21 d. The small intestine relative weight decreased at 250 mg/kg GAL (p<0.05) on d 35, whereas presented an interaction between GAL and energy on d 21 (p<0.05). Likewise, this treatment increased breast muscle ratio (p<0.05). On d 21, triglycerides level of broilers showed interaction between energy and enzyme levels (p<0.05). Uric acid level in 500 mg/kg GAL declined linearly (p<0.05). On d 35, quadratic effects (p<0.05) were observed in total protein, albumin, globulin and cholesterol content for enzyme supplementation. And the interactive effects of energy and GAL on serum values showed more obviously. The study implies that GAL improved energy and nutrient availability of corn-soybean meal diet in broiler. The GAL supplementation to corn-soybean meal based diet can improve performance of broilers in early stages of growth.

Evaluation of Individual Finger Force to Grip Strength in Various Grip Spans and Hand Sizes (파지 폭과 손 크기에 따른 각 손가락이 총 악력에 미치는 영향 분석)

  • Jung, Myung-Chul;Kim, Dae-Min;Kong, Yong-Ku
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.59-65
    • /
    • 2007
  • In this study, six grip spans (45mm-65mm) were tested to evaluate the effects of handle grip span and user's hand size on maximum grip strength, individual finger force, and subjective ratings of comfort using a digital dynamometer with individual force sensors. Forty-six males were assigned into three hand size groups according to their hand lengths. Results showed that overall 55mm and 50mm grip spans were the most comfortable sizes and associated with the highest grip strength in the maximum grip force exertions, whereas 65mm grip span was rated as the least comfortable size as well as the lowest grip strength. In the interaction effect of grip span and hand size, small and middle hand sized participants rated the best preference and the least preference grip spans differently with large hand sized participants. With respect to the analysis of individual finger force, the middle finger force was the strongest and the highest contribution to the total finger force, followed by ring, index and little fingers. In addition, it was noted that each finger had a different optimal grip span for exerting maximum force resulting in a bowed contoured shaped handle for two-handle hand tools. Thus, the grip spans for two-handle hand tools might be designed according to the users' hand and finger anthropometrics to maximize performance and subjective perception of comfort.