• 제목/요약/키워드: intensity of use

검색결과 1,554건 처리시간 0.032초

두 개의 Microphone 배열 특성에 의한 음향 Intensity 측정 (Sound Intensity Measurement for Characteristics of Two Microphone Arrangements.)

  • 장호경
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1985년도 학술발표회 논문집
    • /
    • pp.37-42
    • /
    • 1985
  • The errors caused by developmental finite difference approximations in the two microphone acoustic intensity measurement technique are considered in this paper. The frequencies and pressure responses obtained experimentally, are presented for both face to face (FF) and side by side(SS) microphone configurations. The implications of these results by the use of such a cofiguration for two microphone sound intensity measurement are discussed.

  • PDF

RGB-D 이미지 인텐시티를 이용한 실내 모바일 로봇 장애물 회피 (Obstacle Avoidance of Indoor Mobile Robot using RGB-D Image Intensity)

  • 권기현;이형봉
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권10호
    • /
    • pp.35-42
    • /
    • 2014
  • 주어진 실내 환경에 위치한 여러 장애물에 대한 정보를 사전에 훈련하고 인식하여 로봇의 인지 능력을 향상시키기 위해 스테레오비전 센서의 RGB-D 이미지에서 인텐시티를 기반으로 일정 거리 안에 있는 장애물을 검출하는 기법을 제시한다. RGB-D 인텐시티 정보에 대해 PCA, ICA, LDA, SVM의 주요 패턴인식 알고리즘을 적용하여 인식률 및 실행시간을 구하고, 여러 패턴인식 알고리즘 중에서 어떤 알고리즘이 인식률 및 실행시간 측면에서 적용이 가능한지를 제시한다. 실험결과, RGB-D 데이터와 인텐시티 데이터를 비교한 결과 정확도면에서는 RGB-D 데이터가 4.2% 높은 인식률을 보였으나 훈련시간은 인텐시티 데이터가 RGB-D 이미지에 비해 LDA의 경우 29%, SVM의 경우 31% 빠르게 처리되었으며 테스트시간은 LDA의 경우 70%, SVM의 경우 33% 빠르게 처리되어 모바일 로봇 장애물 인식에 인텐시티 데이터를 사용하는 것이 정확도면에서도 우수하고 처리 속도 면에서 높은 개선효과가 있다.

강우강도와 토지이용을 고려한 비점오염물질 부하량 산정에 관한 연구 (Estimation of Pollutants Loading from Non-Point Sources Based on Rainfall Event and Land use Characteristics)

  • 이혜원;최남희;이용석;최정현
    • 대한환경공학회지
    • /
    • 제33권8호
    • /
    • pp.572-577
    • /
    • 2011
  • 비점오염부하량 산정을 위해 사용되는 원단위는 쉽게 이용 가능하지만, 지역의 토지이용 특성과 강우강도의 시간적인 변이를 고려하지 못하는 단점이 있다. 본 연구에서는 간편하면서도 강우량에 따른 부하량 변화를 고려한 보다 정확한 비점부하량 산정방법을 개발 및 적용하였다. 경기도 경안천 유역에 위치한 두 개의 비점오염저감시설을 대상으로 2010년 6월부터 11월까지 모니터링을 수행하여 강우강도, 유출 특성, 오염부하 등에 관한 분석을 진행하였다. 비점오염원 유출수의 특성을 나타내는 유량가중평균농도(Event Mean Concentration; EMC)의 경우에는 도시 지역인 경기도 광주시 경안동이 산과 밭으로 이루어진 용인시 모현면에 비해 높거나 비슷한 값을 보였으나, TP (Total Phosphorus)의 경우 유역 내 농경지에 사용된 퇴비나 비료에 포함된 인의 영향으로 모현면이 경안동보다 더 높게 나타났다. 강우량과 오염물질 배출부하량과의 관계는 3차원 다항식에 의해 가장 잘 설명되었으며, 0.33~0.81 범위의 결정계수를 나타내고 있다. 산정된 유출율 및 부하량 함수의 기울기가 EMC 결과와 반대되는 경향을 보이는 것으로부터, 비점오염원은 토지이용 이외에도 지형, 토성, 수리 수문현상 등에 따라 배출특성이 달라짐을 알 수 있다. 따라서 비점오염물질의 유출 특성을 정확히 파악하기 위해서는 장기모니터링을 통한자료의 수집을 바탕으로 강우량에 따른 부하량 변화를 고려한 비점부하량 산정함수를 구하는 것이 필요하다.

평판 인텐시티 측정을 통한 근접장 음향 인텐시티와 손실 계수 측정법 (Measurement of Near Field Sound Intensity and Loss Factor Using Plate Intensity Measurement)

  • 김용조;김양한
    • 소음진동
    • /
    • 제7권4호
    • /
    • pp.589-596
    • /
    • 1997
  • A energy equation for a thin plate and surrounding fluid is derived. The equation essentially determines the relation between internal loss of thin plate, energy of acoustic radiation, and structure intensity. We attempted to use this relation to measure internal loss of thin plate. The significance of this approach is that internal loss at any point of a thin plate can be measured. The quality of this measure is dicated by the accuracy of associated measurement systems such as structure and acoustic intensity measurements. A strain gauge bridge system has been developed to measure structure intensity of thin plate. Its performance is tested by experiments.

  • PDF

반동 전단 구조 인텐서티 측정에 의한 제진재 적용과 그에 따른 에어컨 실외기 구조 방사 소음 저감 (Placing Constrained Layer Damping Patches Using Reactive Shearing Structural Intensity in Order to Reduce the Radiated Sound Power of a Air-Conditioner Outdoor Unit)

  • 김규식;강연준;진심원;정인화;이정우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.333-337
    • /
    • 2003
  • The use of reactive shearing structural intensity to place small patches of constrained layer damping material in order to achieve the largest reduction in the radiated sound power of Air-conditioner outdoor unit is described. The normal surface velocity of each panel was measured using a laser doppler vibrometer. Experimental results indicated that patches of constrained layer damping material placed over areas of high reactive structural intensity reduced the radiated sound power significantly more than patches of the same area placed over areas of low reactive structural intensity

  • PDF

REMARKS ON FINITE ELEMENT METHODS FOR CORNER SINGULARITIES USING SIF

  • Kim, Seokchan;Kong, Soo Ryun
    • 호남수학학술지
    • /
    • 제38권3호
    • /
    • pp.661-674
    • /
    • 2016
  • In [15] they introduced a new finite element method for accurate numerical solutions of Poisson equations with corner singularities, which is useful for the problem with known stress intensity factor. They consider the Poisson equations with homogeneous Dirichlet boundary condition, compute the finite element solution using standard FEM and use the extraction formula to compute the stress intensity factor, then they pose a PDE with a regular solution by imposing the nonhomogeneous boundary condition using the computed stress intensity factor, which converges with optimal speed. From the solution we could get accurate solution just by adding the singular part. This approach works for the case when we have the accurate stress intensity factor. In this paper we consider Poisson equations with mixed boundary conditions and show the method depends the accrucy of the stress intensity factor by considering two algorithms.

A FINITE ELEMENT METHOD USING SIF FOR CORNER SINGULARITIES WITH AN NEUMANN BOUNDARY CONDITION

  • Kim, Seokchan;Woo, Gyungsoo
    • East Asian mathematical journal
    • /
    • 제33권1호
    • /
    • pp.1-9
    • /
    • 2017
  • In [8] they introduced a new finite element method for accurate numerical solutions of Poisson equations with corner singularities, which is useful for the problem with known stress intensity factor. They consider the Poisson equations with homogeneous Dirichlet boundary condition, compute the finite element solution using standard FEM and use the extraction formula to compute the stress intensity factor, then they pose a PDE with a regular solution by imposing the nonhomogeneous boundary condition using the computed stress intensity factor, which converges with optimal speed. From the solution they could get accurate solution just by adding the singular part. This approach works for the case when we have the reasonably accurate stress intensity factor. In this paper we consider Poisson equations defined on a domain with a concave corner with Neumann boundary conditions. First we compute the stress intensity factor using the extraction formular, then find the regular part of the solution and the solution.

K 노인전문병원의 공간 통합도와 자연광의 상관관계 분석 (Correlation Analysis between Space Integration and Natural Light in K Senior Hospitals)

  • 문선영;이현수
    • 한국실내디자인학회논문집
    • /
    • 제24권2호
    • /
    • pp.189-196
    • /
    • 2015
  • In case of Senior Hospitals, meticulous care is required in both amount and quality of natural lighting because of the semi-long term residence of patients. Natural lighting has a huge impact on the physical and psychological part for the seniors. Likewise, natural lighting is an important factor considered for hospital design because it can also effect hospitalization period of patients. Research subject was K Senior Hospital which was determined as the courtyard-type building made to provide healing environment through natural lighting. Analysis was performed by dividing the space of K Senior Hospital into Central Treatment Department directly used by patients, Outpatient Department(OPD), Ward Department, Common Use Department. Research was carried out in two ways of integration value analysis using SPACE SYNTAX and illumination intensity analysis using ECOTECT. K Senior Hospital intended to actively let in natural light through courtyard and to make patients exposed to natural light when they walk along the circuit corridor built around the courtyard. This environmental consideration affected the utilization rate of Common Use Department and residence time of patients raising the average of Common Use Department on every floor. As a resuit of this study presenting type C and type D, part of four types of illumination intensity, takes higher percentage of almost every spaces compare to the others therefore K Senior Hospital was designed on the assumption of healing environment composition through natural light. The result of this research would be used meaningfully in the space programming phase of Senior Hospitals in the future. Utilization rate can be adjusted using illumination intensity value in the space that integration rate should be planed to be high. The use(purpose) of space and integration rate can be used as a guideline to set illumination intensity of natural.

농업용 저수지 유역의 보전전략 수립을 위한 특성평가지표 개발 (Development of Evaluation Indices for Preservation Strategies for Agricultural Reservoir Watersheds)

  • 장병관;황보철;황국웅
    • 한국조경학회지
    • /
    • 제35권6호
    • /
    • pp.14-20
    • /
    • 2008
  • The agricultural reservoir watershed plan suggests three specific indices or ways to measure the potential for maintaining reservoir quality in balance with existing or proposed uses: an index of the reservoir's vulnerability to accelerated eutrophication, an index of the degree of land use intensity in reservoir watersheds, and an index of present water quality. Three items that contribute to reservoir eutrophication are included in the vulnerability index: the ratio of reservoir volume to drainage-basin area, shoreline configuration, and mean depth. The watershed land-use intensity index is based on road proximity and upland watershed land-use intensity. Water quality can be given a COD level. All six indicators are considered separately and then rated as follow: low (1), medium (2), or high (3). Five out of 30survey sites were less than 8points, 17sites were less than 11points and 8sites were less than 14points. This study suggests that the sites in the first ranking were potential areas for preservation, sites in the second ranking were potential areas for environmental friendly planning and sites in the third ranking were potential areas for residential need oriented planning. The advantage of this study is the low cost of gathering data for the development of local policy for the planning, management and protection of reservoir basin.

Albumin-conjugated Cadmium Sulfide Nanoparticles and their Interaction with KB Cells

  • Selim, K.M. Kamruzzaman;Kang, Inn-Kyu;Guo, Haiqing
    • Macromolecular Research
    • /
    • 제17권6호
    • /
    • pp.403-410
    • /
    • 2009
  • Cytotoxicity is a severe problem of cadmium sulfide nanoparticles(CSNPs) for use in biological systems. In the present study, mercaptoacetic acid-coated CSNPs were conjugated with bovine serum albumin (BSA) to improve biocompatibility. The surface properties of the CSNPs and albumin-conjugated CSNPs (ACSNPs) were characterized by XRD, UV, FTIR, EA, TEM and DLS. Human breast cancer cells (KB cells) were then cultured in the presence of the nanoparticles to evaluate the cytotoxicity of CSNPs and ACSNPs. Finally, the fluorescence intensity of the nanoparticles' aqueous solution was examined using a fluorescence spectrometer. The results showed that the cell compatibility and fluorescence intensity of ACSNPs were higher than those of CSNPs. The strongly luminescent features of the biocompatible ACSNPs are promising for use in biological fields such as cellular labeling, intracellular tracking and molecular imaging.