• Title/Summary/Keyword: integrated condition monitoring

Search Result 116, Processing Time 0.037 seconds

헐겁게 지지된 저널베어링의 마모 및 전동특성 실험적 연구 (An Experimental Study on the Wear and Vibrational Characteristics of a Loosely supported proceeding Bearing)

  • 장래혁;편성관;윤의성;공호성;최동훈
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.53-62
    • /
    • 2002
  • Condition monitoring plays a vital role since it sustains reliable operation of industrial plants and machinery in the pursuit of economic whole life operation. In order to achieve this goal, it is needed to monitor various parameters of mechanical system such as vibration, wear, temperature and etc., and finally to diagnosis the root causes of any possible abnormal machine condition. In this work, a machine failure caused by mechanical looseness was experimentally simulated and on-line measurement of the vibration, wear and temperature were simultaneously measured. For the quantitative analyses of machine wear, several statistical parameters of the wear particle size distribution were obtained through the center moment method of the Weibull distribution function, and they were compared to vibrational characteristics. Results showed that the wear and vibrational characteristics did not reveal a strong correlation each other in a loosely supported proceeding bearing.

  • PDF

용광로 연소대 관리시스템 개발 (Development of combustion zone monitoring system for a blast furnace)

  • 최태화
    • 제어로봇시스템학회논문지
    • /
    • 제3권3호
    • /
    • pp.318-322
    • /
    • 1997
  • A prototype of combustion zone monitoring system as been developed and installed into tuyeres of the blast furnace. The system consists of CCD(charge coupled device) cameras, sonic flow meters, an image processor and a personal computer. The personal computer collects raceway luminance data and operational data from the image processor that is connected to the color CCD camera from the blast furnace process computer, respectively. In addition, the sonic flow meters supply coal injection rate data to the personal computer. Then, the personal computer evaluates the combustion conditions with the raceway inspection algorithm. This integrated monitoring system allows us to detect abnormal raceway conditions and the clogging status of coal injection pipe. The image processing techniques of the system enable us to effectively monitor unburnt coal sticking to tuyere tip and injection lance wear conditions. Such a developed system ensures rapid and precise raceway inspection. The image processing capability of the system has helped operator to early detect both the unburnt coal sticking problem and the errosion problem of injection lance. Furthermore, the system could control the abnormal raceway condition based the the analysis results obtained from combustion monitoring.

  • PDF

무인항공체계 기반 시설물 상태점검 최근 연구동향 분석 (A Literature Review of Unmanned Aircraft System (UAS) Integrated Constructed Facility Condition Inspections)

  • 권진혁;윤지영;윤종영;이동훈;김성진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.172-173
    • /
    • 2021
  • In recent, unmanned Aircraft Systems (UAS) have been widely used for various purposes, such as safety inspection, facility condition inspection, progress monitoring, in the architecture engineering, and construction (AEC) industry. This technology can provide visual assets regarding the conditions of construction jobsites as well as constructed facilities during flying over the point of interests. With the significant interests in this advancement, the recent studies have presented how the UAS can be applied fro different types of facilities (e.g., buildings, power genereation systems, roads, or bridges) to inspect the current conditions of them for safe operations as well as public's safety. This study reviewed the receent studies to document their scientific findings and practical contributions, as well as provided the overview of further implications for future studies.

  • PDF

디지털전관방송을 위한 통합믹서컨트롤러 개발 (Development of Integrated Mixer Controller for Digital Public Address)

  • 조주필;김관웅;김대익
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.19-24
    • /
    • 2017
  • 최근 IT기술의 발전을 근간으로 PA시스템에 IT기술이 접목된 혁신적인 제품들이 개발되고 있다. 본 논문에서는 디지털 전관방송을 위한 통합 믹서 컨트롤러를 제안하였다. 기존 디지털 전관방송을 구성하는 디지털믹서와 디지털 통합 컨트롤러의 기능을 포함한 통합믹서컨트롤러를 개발하였다. 개발된 통합믹서컨트롤러는 16개의 오디오입력채널과 8개의 출력채널을 가진 다채널 믹서 기능을 가진다. 그리고, 디지털오디오신호를 처리하기 위한 EQ, Matrix, Limiter을 가지고 있다. 또한, 개발된 컨트롤러는 믹서의 동작상태 모니터링과 전체 PA시스템을 제어하기 위한 인터넷 연결기능을 가진다.

G-induced Loss of Consciousness(G-LOC) 예측을 위한 신체 부위별 Electromyogram(EMG) 신호 분석 (Analysis on Electromyogram(EMG) Signals by Body Parts for G-induced Loss of Consciousness(G-LOC) Prediction)

  • 김성호;김동수;조태환;이용균;최부용
    • 한국군사과학기술학회지
    • /
    • 제20권1호
    • /
    • pp.119-128
    • /
    • 2017
  • G-induced Loss of Consciousness(G-LOC) can be predicted by measuring Electromyogram(EMG) signals. Existing studies have mainly focused on specific body parts and lacked of consideration with quantitative EMG indices. The purpose of this study is to analyze the indices of EMG signals by human body parts for monitoring G-LOC condition. The data of seven EMG features such as Root Mean Square(RMS), Integrated Absolute Value(IAV), and Mean Absolute Value(MAV) for reflecting muscle contraction and Slope Sign Changes(SSC), Waveform Length (WL), Zero Crossing(ZC), and Median Frequency(MF) for representing muscle contraction and fatigue was retrieved from high G-training on a human centrifuge simulator. A total of 19 trainees out of 47 trainees of the Korean Air Force fell into G-LOC condition during the training in attaching EMG sensor to three body parts(neck, abdomen, calf). IAV, MAV, WL, and ZC under condition after G-LOC were decreased by 17 %, 17 %, 18 %, and 4 % comparing to those under condition before G-LOC respectively. Also, RMS, IAV, MAV, and WL in neck part under condition after G-LOC were higher than those under condition before G-LOC; while, those in abdomen and calf part lower. This study suggest that measurement of IAV and WL by attaching EMG sensor to calf part may be optimal for predicting G-LOC.

국가 교육과정 모니터링 체제 개선 연구 (Improving National Curriculum Monitoring System)

  • 이근호;이병천;가은아;이주연
    • 한국콘텐츠학회논문지
    • /
    • 제16권2호
    • /
    • pp.588-599
    • /
    • 2016
  • 본 연구의 목적은 호주와 싱가포르 교육과정 모니터링 체제를 분석하여 우리나라 교육과정 모니터링 체제 개선을 위한 시사점을 도출하는 데 있다. 본 연구의 목적을 달성하기 위하여 우선 우리나라의 2007 교육과정부터 2009 개정 교육과정 모니터링 체제의 문제점을 문헌 연구와 현장 교사 면담 등을 통하여 분석하였다. 이를 토대로 해외 사례 연구의 시사점 도출의 준거를 설정하였으며, 설정된 준거에 기초하여 싱가포르와 호주를 방문하고 국가 교육과정 모니터링 체제의 실제 운영 사례를 조사 분석하였다. 이 과정에서 해당 국가의 교육부 관계자, 학교 관리자, 현장 교사 등을 면담하여 문헌과 인터넷 탐색 등에 기반을 둔 사전 조사의 실질적 운영 현황을 파악하였다. 이는 비단 현재의 시스템이나 현황에 대한 표피적인 조사를 넘어서 당면하고 있는 문제점이나 개선 요구 등과 같은 실체적인 내용을 파악하여 시사점을 도출하기 위한 것이었다. 도출된 시사점은 국가교육과정 모니터링 시스템의 통합적 접근, 쌍방향과 개방형 의사소통 방식의 개선, 모니터링 시스템 운영의 내실화 등이 제안되었다.

수배전반 진단을 위한 통합형 센서모듈 (An Integrated Sensor Module for Diagnosis of Closed Switchboards)

  • 차상욱;차현규;박대원;박희철;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2043-2048
    • /
    • 2011
  • According to the statistical report from National Emergency Management Agency (NEMA) in Korea, the accident rate of closed switchboards in power systems occupies over 40%. In this paper, an integrated sensor module for monitoring the condition of closed switchboards is described. The sensor module monitors electro-magnetic (EM) wave, ultra-violet (UV) ray, heat and smoke generated by electrical discharges or insulation breakdown. The effective detection ranges were decided from experiment results; 100 kHz~10 MHz for EM wave, 220 nm~395 nm for UV ray and 0~$150^{\circ}C$ for heat, respectively. The prototype sensor module includes all functions above-mentioned in one device.

  • PDF

건물일체형 지열시스템의 동계 성능 모니터링 연구 (Performance Monitoring Study of Building Integrated Geothermal System in Winter)

  • 유형규;배상환
    • 한국지열·수열에너지학회논문집
    • /
    • 제6권1호
    • /
    • pp.23-28
    • /
    • 2010
  • The objective of this study is to develope ground heat exchanger using PHC pile used to building foundation, and it's element technology. So we made PHC piles into ground heat exchanger and evaluate it's performance. First, we studied PHC pile type, heat exchanger pipe, grouting materials, and present apartment house's foundation condition for PHC ground heat exchanger. As a result we designed BIGS(Building Integrated Geothermal System) prototype. Second, we applied BIGS to apartment houses' utility building in Osan built by Daelim. Third, we monitored heating performance of winter season. 1be result of heating performance was so good to apply to heat & cooling system in building.

도시철도 전력설비 상태진단 통합시스템 현장구현 (Urban Rail Power Facilities on-site Implementation of an Integrated System Diagnosis)

  • 임형길;이병두;김용덕;장순호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2015-2020
    • /
    • 2011
  • Key set the current non-urban rail power failure of equipment to operate the railway will generate a lot of problems. I know in advance the ideal of power equipment to prevent the failure to derive an efficient replacement cycle for the power equipment monitoring and diagnosis of the condition can become necessary to develop a system. In order to determine the status of the power plant during operation and behavior of the partial discharge current state data, regular monitoring and inspection requirements also stamp the basic current, voltage, temperature and humidity should be identified.

  • PDF

Sensors, smart structures technology and steel structures

  • Liu, Shih-Chi
    • Smart Structures and Systems
    • /
    • 제4권5호
    • /
    • pp.517-530
    • /
    • 2008
  • This paper deals with civil infrastructures in general, sensor and smart structure technology, and smart steel structures in particular. Smart structures technology, an integrated engineering field comprising sensor technology, structural control, smart materials and structural health monitoring, could dramatically transform and revolutionize the design, construction and maintenance of civil engineering structures. The central core of this technology is sensor and sensor networks that provide the essential data input in real time for condition assessment and decision making. Sensors and robust monitoring algorithms that can reliably detect the occurrence, location, and severity of damages such as crack and corrosion in steel structures will lead to increased levels of safety for civil infrastructure, and may significantly cut maintenance or repair cost through early detection. The emphasis of this paper is on sensor technology with a potential use in steel structures.