• Title/Summary/Keyword: insulation thickness

검색결과 355건 처리시간 0.028초

국내 습식 잠수복 생산 업체의 생산실태 조사 및 향후 연구과제 (Study on the wetsuit manufacturing status in Korea and future research task)

  • 신현숙;최인영
    • 한국의상디자인학회지
    • /
    • 제23권3호
    • /
    • pp.99-108
    • /
    • 2021
  • The present study examines the overall manufacturing status of local wetsuit makers, problems in the manufacturing process, and future research tasks. The study revealed that most manufacturers use neoprene fabric of varying thickness, depending on the body part. Normally, 3 mm-thick fabric is utilized for high-activity body parts and 5 mm-thick fabric is used for high-activity areas requiring thermal insulation. In terms of the manufacturing method, the tools and manufacturing processes used by companies were found to be similar. However, because of the nature of wetsuits requiring a more complicated manufacturing method than that of general clothing, there were some differences in the manufacturing method processes from company to company, such as bonding and ease treatments. According to wetsuit manufacturers, they make incisions in consideration of the body's curvature and the overall shape and design of the wetsuit when developing patterns. For example, most answered that they preform the wrist and ankle parts, where the body's curvature is obvious. On the question regarding the "difficult manufacturing process", the most frequent response was the "bonding" process. Most manufacturers were found to focus on designs that can improve mobility and clothing fit, and commonly experienced low-order quantity as an operational difficulty. As for the question on the wetsuit-related technology needed in the future, the "development of various designs" was the most frequent answer, followed by the "development of lightweight and diverse materials".

판형 열유속계의 소형화에 따른 공간 해상도 개선에 관한 연구 (A Study on the Improvement of Spatial Resolution with Miniaturization of Plate Thermometer)

  • 윤홍석;한호식;황철홍
    • 한국화재소방학회논문지
    • /
    • 제33권2호
    • /
    • pp.39-46
    • /
    • 2019
  • 화재환경에서 열유속 측정을 위해 사용되는 판형 열유속계의 측정 오차 및 소형화를 통한 공간 해상도 개선에 관한 실험적 연구가 수행되었다. 주요 결과로서, Plate의 뒷면에 설치되는 단열재의 두께 및 밀도 변화에 따른 측정값 분석을 통해, 판형 열유속계의 측면으로의 열손실이 측정오차에 큰 영향을 줄 수 있음이 확인되었다. 또한 기존 10 cm 크기의 정사각형 형상을 기준으로 소형화를 통해 3 cm 크기의 판형 열유속계도 충분히 정확한 열유속 측정이 가능함을 확인하였다. 본 연구결과는 화재환경에서 보다 정확한 국소 위치의 열유속 측정을 위해 유용하게 활용될 것으로 기대된다.

실리콘 고분자 수지의 버클링을 통한 스틸기반 태양전지의 효율 향상 (Buckling Formation on Steel-Based Solar Cell Induced by Silicone Resin Coat and Its Improvement on Performance Efficiency)

  • 박영준;오경석
    • Korean Chemical Engineering Research
    • /
    • 제57권4호
    • /
    • pp.519-524
    • /
    • 2019
  • 스테인리스 스틸을 사용한 태양전지는 효율성이 낮지만, 패시배이션을 방지하는 목적의 추가적인 막을 설치하지 않아도 되는 장점을 가지고 있다. 본 연구에서는 스테인리스 스틸을 기반으로 하는 a-Si:H 박막 태양전지 제조에 고분자 재료인 실리콘 수지를 도입하였다. 실리콘 수지의 사용 목적은 스틸표면의 평탄화와 전기 절연성을 도입하는 것이다. 초기 공정에서, 스테일리스 스틸의 표면에 실리콘 수지를 스핀코팅을 통해 $2{\sim}3{\mu}m$ 두께로 코팅하였다. 이후 증착법을 이용하여 알루미늄 박막 코팅을 시도하였다. 알루미늄 증착시, 마이크로미터 크기의 실리콘 수지 표면위에 버클링이 형성되었다. 형성된 실리콘 수지 위로 반도체층 도입 등 추가적인 박막 공정을 실시하였으며, 박막층에 유지된 버클링은 광산란 효과를 증가시켜 태양전지의 효율 향상으로 연계되었음을 알 수 있었다.

35㎛ 점탄성수지가 적용된 1.035mm 제진강판의 이종소재간 저항점용접 특성분석 (Characteristic Analysis of Resistance Spot Welding between Dissimilar Materials of 1.035mm Laminated Vibration Damping Steel with 35㎛ Viscoelastic Resin)

  • 배기만;백종진;신창열;김승경;강명창
    • 한국기계가공학회지
    • /
    • 제20권12호
    • /
    • pp.24-29
    • /
    • 2021
  • Recently, owing to the high demand for eco-friendly cars in the automotive industry, noise and vibrations have become major challenges. The use of laminated damping steel is increasing in response to these demands. Laminated damping steel is primarily used in sound insulation plates. The vibration energy is converted into thermal energy due to the viscoelastic resin being located between two steel sheets and being able to damp the vibrations when an external force, such as, noise or vibration is applied to the steel plate. Laminated damping steel is chiefly applied to dash panels in automotive body parts, and because of its structure, junction technology for bonding with other components is necessary. However, there has not been sufficient research conducted on junctions. In this study, regardless of the electrode shape, in the range of 4.0 ~ 8.0 kA welding current, the same welding force and welding time were applied which were 2.8 kN and 200 m/s (12 cycles) and the tensile shear load and nugget size were analyzed after the resistance spot welding between different materials of laminated damping steel with a thickness of 1.035 mm. The results show that in the range of 5 ~ 8 kA welding current, 1.035 mm laminated damping steel meets the MS181-15 standard, which is the technical standard of Hyundai-Kia Motors.

Distortional buckling performance of cold-formed steel lightweight concrete composite columns

  • Yanchun Li;Aihong Han;Ruibo Li;Jihao Chen;Yanfen Xie;Jiaojiao Chen
    • Steel and Composite Structures
    • /
    • 제50권6호
    • /
    • pp.675-688
    • /
    • 2024
  • Cold-formed steel (CFS) is prone to buckling failure under loading. Lightweight concrete (LC) made of lightweight aggregate has light weight and excellent thermal insulation performance. However, concrete is brittle in nature which is why different materials have been used to improve this inherent behavior of concrete. The distortional buckling (DB) performance of cold-formed steel-lightweight concrete (CFS-LC) composite columns was investigated in this paper. Firstly, the compressive strength test of foam concrete (FC) and ceramsite concrete (CC) was carried out. The performance of the CFS-LC members was investigated. The test results indicated that the concrete-filled can effectively control the DB of the members. Secondly, finite element (FE) models of each test specimen were developed and validated with the experimental tests followed by extensive parametric studies using numerical analysis based on the validated FE models. The results show that the thickness of the steel and the strength of the concrete-filled were the main factors on the DB and bearing capacity of the members. Finally, the bearing capacity of the test specimens was calculated by using current codes. The results showed that the design results of the AIJ-1997 specification were closer to the experimental and FE values, while other results of specifications were conservative.

투습발수직물과 보온단열소재의 열 및 수분전달 특성 (Thermal and Water Transmission Properties of Vapor Permeable Water Repellent Fabrics and Thermal Insulation Batting Materials)

  • 조길수;최종명;이정주;이선우
    • 한국의류학회지
    • /
    • 제16권2호
    • /
    • pp.237-244
    • /
    • 1992
  • The purpose of this study was to comparatively evaluate thermal and water transmission properties of several vapor permeable water repellent (VPWR) fabrics and synthetic battings that became available in recent years. Five VPWR fabrics evaluated were Hipora in three coating variants, $Gore-Tex^{\circledR}$ and $Aitace^{\circledR}$. Battings evaluated were $Viwarma^{\circledR}$, $Uniwarmr^{\circledR}$, $Thinsulate^{\circledR}$, and $Airseal^{\circledR}$ Thermal resistance and water vapor transmission were measured for each fabric and batting and in all combinations. Thermal resistance at zero and 37 cm/sec air velocity was determined by the Thermo Labo II technique for simultaneously measuring conduction and radiation heat transfer. Water vapor transmission over 24 hours was measured by a modified weight-gain method in a compact humid chamber at conditions simulating the clothing climate under heavy exercise ($40{\pm}1^{\circ}C$, $90{\pm}2\%$ R.H., and 0.5 m/sec air velocity). Fabric porosity was calculated from fiber density and fabric weight, thickness, and area. Thermal resistance results for the fabrics showed the effectiveness of coatings in inhibiting heat transfer. Measurements taken in wind were: $31.1\~37.6\%$ for $Hipora^{\circledR}$ variants; $31.0\%$ for $Gore-Tex^{\circledR}$; and $18.4\%$ for $Aitaca^{\circledR}$ Measurements without wind were higher but in the same order. Water vapor transmission results were in reverse order: $Aitac^{\circledR}$, $8.8 kg/m^{2};\;Gore-Tex^{\circledR}$, 6.4 kg/$m^{2}$; and $Hipora^{\circledR},\;4.4\~6.0\;kg/m^{2}$. In general thermal resistance increased with porosity. For battings, the thermal resistance with wind results were: $Viwarmu^{\circledR}$, $65.0\%;\; Thinsulate^{\circledR}$, $62.0\%$; $Uniwarm^{\circledR}$, $61.0\%$; and $Airseala^{\circledR},\;53.1\%$. Thermal resistance was proportional to thickness. Thermal resistance of fabric-batting combinations were $20\%$ higher than those of the battings only. Water vapor transmission for combinations was mainly affected by that for the VPWR fabric used.

  • PDF

실리카 에어로겔을 이용한 다겹보온커튼의 온실 난방 특성 분석 (Analysis of Heating Characteristics of Multi-Layered Insulation Curtain with Silica Aerogel in Greenhouses)

  • 진병옥;김형권;유영선;이태석;김영화;오성식;강금춘
    • 생물환경조절학회지
    • /
    • 제29권4호
    • /
    • pp.320-325
    • /
    • 2020
  • 본 연구는 최근 신소재 단열재로 주목받고 있는 실리카 에어로겔을 이용하여 현재 사용되고 있는 다겹보온커튼의 단점을 보완하고 보온성을 유지 및 향상시킬 수 있는 새로운 조합의 다겹보온커튼을 제작 하여 현장에 설치함으로써 보온성과 경제성을 분석하고자 한다. 실험에 사용된 다겹보온커튼은 실리카 에어로겔이 함유된 부직포를 사용하여 2가지의 조합으로 제작하였으며 시중에 판매, 사용되고 있는 관행 다겹보온 커튼과의 차이에 따른 온습도변화와 연료소비량을 측정하여 비교분석하였다. 실험결과 단동온실과 연동온실에서 다겹보온커튼 차이에 따른 온습도변화는 미세하게 나타났으나, 거의 비슷한 온습도 값을 유지하였다. 이는 실리카 에어로겔을 이용한 다겹보온커튼이 관행 다겹보온커튼에 비해 온습도 제어 측면에서 문제가 없음을 나타냈다. 난방에너지 비교분석 결과, 실리카 에어로겔을 이용한 다겹보온커튼이 관행 다겹보온커튼에 비해 연료소비량은 단동온실에서 약 15%, 연동온실에서 약 20%의 연료소비량을 절감한 것으로 나타나 온실의 규모와 사용기간이 증가함에 따라 난방에너지는 절감될 것으로 판단된다. 실리카 에어로겔 이용 다겹보온커튼이 관행 다겹보온커튼에 비해 통기성과 보온성이 증가되는 것이 확인되었다. 그러나, 연동온실에서 사용된 다겹보온커튼은 관행 다겹보온커튼에 비해 무게가 증가하고 뻣뻣하여 시공성과 작동성이 떨어지는 것을 확인할 수 있었다. 이에 단동온실에서 사용된 다겹보온 커튼에서는 개선사항을 적용하였다. 내부단열재의 교체를 통해 두께를 감소시키고 뻣뻣함을 개선함으로써 농가가 사용하기에 충분한 가능성이 있다는 것을 확인하였다.

마이크로파 하이브리드 소결법에 의한 NTC 서미스터의 제조 (Microwave hybrid sintering of NTC themistor)

  • 최영락;안진용;안주삼;백동규;최승철
    • 한국결정성장학회지
    • /
    • 제8권3호
    • /
    • pp.508-512
    • /
    • 1998
  • 마이크로파(2.45GHz) 에너지를 이용한 소결법으로 $1100^{\circ}C$~$1300^{\circ}C$의 온도범위에서 반도체 세라믹스인 $Mn_3O_4{\cdot}Co_3O_4{\cdot}3NiO$ 조성의 NTC 서미스터를 소결하였으며, 그 전기적 특성을 조사하였다. 소결온도가 높아질수록 소결밀도가 높은 치밀한 소결체를 얻을 수 있었으며, 25~$85^{\circ}C$ 범위의 온도변화에 따른 전기저항변화 특성으로부터 구한 비저항 $B_{25^{\circ/85^{\circ}}$ 정수는 3100~3200K이었다. 마이크로파 하이브리드, 소결법으로 소결된 시편과 일반소결법으로 소결된 시편을 비교하면 소결특성과 전기적물성에서 비슷한 결과를 얻을 수 있었다. 마이크로파 에너지를 이용한 소결공정은 20분 안에 완료되는 짧은 시간의 급속소결법으로 공정 시간과 에너지를 크게 절감할 수 있었다.

  • PDF

온실용 이중피복 및 보온재의 관류열전달계수 산정을 위한 수치적 연구 (A Numerical Study for Calculation of Overall Heat Transfer Coefficient of Double Layers Covering and Insulation Material for Greenhouse)

  • 이종원;김동건;이현우
    • Current Research on Agriculture and Life Sciences
    • /
    • 제33권2호
    • /
    • pp.41-47
    • /
    • 2015
  • 본 연구는 온실용 피복재 및 보온재의 조합에 대한 시뮬레이션 해석모델을 개발하여 관류열전달계수를 산정하고 측정된 결과와 비교하여 타당성을 평가하기 위해 수행되었으며 결과를 요약하면 다음과 같다. 유리이중피복의 경우 이중피복 사이의 공기층이 두꺼워짐에 따라 관류열전달계수가 서서히 작아져서 공기층 두께가 25 mm 이상이 되면 관류열전달계수의 변화가 거의 없는 것을 확인할 수 있었다. 또한 온도차가 증가함에 따라 관류열전달계수도 증가하는 것을 확인할 수 있었다. 두 플라스틱 피복재 사이에는 대류에 의한 열전달이 활발하게 일어나기 때문에 비정상 유동에 의한 열전달이 발생하고 이로 인해 온도분포도 비선형적으로 변하는 것으로 사료된다. 플라스틱 피복재 및 보온재들의 간격이 50~200 mm범위에서 변화할 때에 피복재의 간격은 관류열전달계수 큰 영향을 미치지 않는다는 사실을 확인할 수 있었다. 천공복사를 고려한 경우와 고려하지 않은 경우 모두 핫박스의 내외부 온도차가 $30^{\circ}C$인 조건에 대해서는 수치해석결과와 실험결과가 대체로 잘 일치하였다. 따라서 핫박스의 내외부 온도차가 $30^{\circ}C$ 이상인 조건에서 수치해석을 통해 관류열전달계수를 산정한다면 신뢰성 있는 값을 얻을 수 있을 것으로 판단된다.

대형 풍력터빈 절연커플링 시험장치 개발 및 평가 (Development and Evaluation for the Insulated Coupling Test Machine of a Large Wind Turbine)

  • 주성하;김동현;오민우;김수현;배준우;강종훈;이형우;김경희
    • 대한기계학회논문집B
    • /
    • 제40권8호
    • /
    • pp.543-556
    • /
    • 2016
  • 본 연구에서는 5 MW 급 대형 풍력터빈 절연커플링의 시험평가 장치를 자체설계 개발하였다. 3 MW 급 대형 풍력터빈용 절연커플링에 대한 공인성능시험평가를 수행하고 시험장치에 대해서는 개발요구도, 장치설계, 기능적 고려사항, 구조진동해석 및 검토 결과를 제시하였다. 본 연구에서 고려한 대형 풍력용 절연커플링 모델과 같이 필라멘트와인딩 공법으로 제작된 두꺼운 유리섬유 복합재 파이프의 경우 shell 요소 기반의 유한요소 해석기법과 두께 효과를 정확하게 모델링 할 수 있는 복합재 적층형 3D solid 모델링 기법의 비교결과를 제시하였다. 또한 다수의 판스프링이 적층된 형태로 제작된 디스크팩 구조에 대한 효과적인 비선형 유한요소 해석기법을 제시하고 시험평가 결과와 비교 검증을 수행하였다.