• Title/Summary/Keyword: insulation detail

Search Result 42, Processing Time 0.031 seconds

Novel Active Voltage Quality Regulator with Adaptive DC-Link Voltage Control

  • Xiao, Guochun;Zeng, Zhong;Liu, Kai;Hu, Zhiliang;Wang, Zhaoan
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.880-889
    • /
    • 2011
  • In this paper, a novel Active Voltage Quality Regulator (AVQR) topology with a thyristor rectifier and an adaptive dclink voltage control strategy are proposed. The proposed AVQR can efficiently mitigate the long duration variations (e.g. undervoltages/overvoltages), voltage imbalances and voltage harmonics. Compared with conventional AVQRs, it can regulate the load voltage very well with a much lower dc-link voltage. This is accomplished by replacing the diode rectifier with a thyristor rectifier. Moreover, its dc-link voltage can vary with the deviations of the supply voltage through the proposed adaptive dc-link voltage control strategy. All of these contribute to its significantly higher efficiency for online operating, which is very important and attractive for many applications. The proposed topology and control strategy are theoretically analyzed in detail. Simulation results are also provided in the paper. Finally, the feasibility and effectiveness of the proposed method are verified by means of experimental results from a 2kVA prototype. Both of the simulation and experimental results show that the proposed AVQR can achieve a much higher efficiency and similar regulation performance when compared with the conventional ones.

Effect of Decomposition Product on the Insulation Characteristics of Mineral Oil as Insulation Medium of Distribution Transformer (주상변압기의 절연매질인 광유의 절연파괴특성에서 분해생성물의 영향)

  • Lim, Dong-Young;Park, Sung-Gyn;Park, Cheol-Ho;Kim, Ki-Chai;Lee, Kwang-Sik;Choi, Eun-Hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.52-59
    • /
    • 2014
  • This paper deals with the effect of decomposition products which occur in breakdown of mineral oil, on the insulation characteristics of its oil. Breakdown tests in the oil were conducted by the proposed experimental methods under a quasi-uniform field and AC HV (60Hz). The breakdown voltage in the oil shows characteristics of dispersion from successive breakdowns and, it is found that there are three patterns of the decomposition products behavior at the process of breakdown progress in the oil. Finally, the breakdown voltage dispersion in the oil can be described in detail based on the behavior patterns of the decomposition products and its diffusion time.

The preparation and characteristics of polyimide for applications as an insulation of semiconductor devices (반도체 소자의 절연막응용을 위한 폴리이미드 박막의 제작과 특성)

  • 김형권;이은학;박수홍;이백수;이덕출
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.3B
    • /
    • pp.340-345
    • /
    • 1999
  • In this paper, polyimide thin films are fabricated by vapor deposition polymerization method appling to the interlayer insulator of semiconductor device, and are investigated in detail. It is found that the packing density and uniformity of films deposited by thermal evaporation are increased according to curing temperature. The resistivity, breakdown strength, relative permitivity, and dielectric loss are $3.2\tomes10^{15}\Omega$cm, 4.61 MV/cm, 2.9(10kHz) at $25^{\circ}C$, respectively. This thin films can be endured at $230^{\circ}C$ for 20,000 hours. Finally, we conclude that the thin films having the characteristics similar to those of $SiO_2$ can be used as an insulation films between layers of semiconductor device.

  • PDF

Insulation Details and Energy Performance of Post-Beam Timber House for Insulation Standards (단열 기준에 따른 기둥-보 목조주택의 단열 상세 및 에너지 성능)

  • Kim, Sejong;Park, Joo-Saeng
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.876-883
    • /
    • 2015
  • Han-green project, which pursues Korean style post and beam timber house with traditional construction technique of Han-ok, has been carried out in KFRI (Korea Forest Research Institute) since 2006. Recently, the improvement of its building energy performance was studied with energy-saving elements. This study was conducted to provide the insulation details of building envelopes in a post-beam timber house for recent enhanced insulation standards and following effect on building energy performance. The level of thermal transmittance (U-value) values of building envelopes was composed of two stages: present Korean insulation standards and passive house. To evaluate building energy performance, the building airtightness values of two stages was ACH50 = $3.0h^{-1}$ for common domestic timber house constructed recently, and ACH50 = $0.6h^{-1}$ for passive house. Consequently, four cases of the building energy performance according to the combination of U-value with airtightness were evaluated. The test house for evaluation was located in Seoul and its energy performance was evaluated with CE3 commercial building energy simulation program. The result showed that enhanced insulation from level I to II reduced $14kWh/(m^2{\cdot}a)$ of annual heating energy demand regardless of airtightness.

Unbalanced Power Sharing for Islanded Droop-Controlled Microgrids

  • Jia, Yaoqin;Li, Daoyang;Chen, Zhen
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.234-243
    • /
    • 2019
  • Studying the control strategy of a microgrid under the load unbalanced state helps to improve the stability of the system. The magnitude of the power fluctuation, which occurs between the power supply and the load, is generated in a microgrid under the load unbalanced state is called negative sequence reactive power $Q^-$. Traditional power distribution methods such as P-f, Q-E droop control can only distribute power with positive sequence current information. However, they have no effect on $Q^-$ with negative sequence current information. In this paper, a stationary-frame control method for power sharing and voltage unbalance compensation in islanded microgrids is proposed. This method is based on the proper output impedance control of distributed generation unit (DG unit) interface converters. The control system of a DG unit mainly consists of an active-power-frequency and reactive-power-voltage droop controller, an output impedance controller, and voltage and current controllers. The proposed method allows for the sharing of imbalance current among the DG unit and it can compensate voltage unbalance at the same time. The design approach of the control system is discussed in detail. Simulation and experimental results are presented. These results demonstrate that the proposed method is effective in the compensation of voltage unbalance and the power distribution.

Comparison of Standards for a 1ϕ 2 W MCCB and Study on the Evaluation of Heat Resistance Characteristics (1ϕ 2 W MCCB의 기준 비교 및 내열 특성 평가에 관한 연구)

  • Choi, Chung-Seog;Lee, Jae-Hyuk
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.21-28
    • /
    • 2014
  • This study obtained the following results by analyzing the standards related to a $1{\phi}$ 2W MCCB and evaluating its heat resistance characteristics. Since KS C 8321 corresponds to IEC 60947-2 standards, most of the related regulations are similar. The NFPA, which presents the user oriented safety regulations, contains no details about tests or inspections, etc., but it does specify in detail the regulations directly related to safety. It can be seen that KS C 8321 classifies in detail the items about tests and inspections. However, IEC 60947-2 and IEEE C37.51 simplified the test and inspection items or omitted some of them. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state. In addition, most of the fixing hanger was melted down, losing their function. When applying thermal stress to the MCCB at $90^{\circ}C$, it showed nothing peculiar, but the fixing hanger was partly deformed at $105^{\circ}C$ and $120^{\circ}C$. It was found that the fixing hanger was deformed and the name plate was discolored at $150^{\circ}C$. It can be seen from the analysis of the internals of the MCCB that the trip bar has been melted away and that the up and down operator has moved up. The experiment performed by applying a withstanding voltage of 6 kV for 60 s showed that all items remained intact. In addition, the evaluation of the insulation performance performed by applying DC 500 V using an insulation-resistance tester showed good insulation performance.

A PI Control Algorithm with Zero Static Misadjustment for Tracking the Harmonic Current of Three-Level APFs

  • He, Yingjie;Liu, Jinjun;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.175-182
    • /
    • 2014
  • Tracking harmonic current quickly and precisely is one of the keys to designing active power filters (APF). In the past, the current state feedback decoupling PI control was an effective means for three-phase systems in the current control of constant voltage constant frequency inverters and high frequency PWM reversible rectifiers. This paper analyzes in detail the limitation of the conventional PI conditioner in the APF application field and presents a novel PI control method. Canceling the delay of one sampling period and the misadjustment for tracking the harmonic current is the key problem of this PI control. In this PI control, the predictive output current value is obtained by a state observer. The delay of one sampling period is remedied in this digital control system by the state observer. The predictive harmonic command current value is obtained by a repetitive predictor synchronously. The repetitive predictor can achieve better predictions of the harmonic current. By this means, the misadjustment of the conventional PI control for tracking the harmonic current is cancelled. The experiment results with a three-level NPC APF indicate that the steady-state accuracy and dynamic response of this method are satisfying when the proposed control scheme is implemented.

Sloshing Impact Response Analysis for Insulation System of LNG CCS Considering Elastic Support Effects of Hull Structures (선체구조의 탄성지지 효과를 고려한 LNG 운반선 방열구조의 슬로싱 충격응답 해석법에 관한 연구)

  • Nho, In Sik;Ki, Min-Seok;Kim, Sung-Chan;Lee, Jang Hyun;Kim, Yonghwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.357-363
    • /
    • 2017
  • The sloshing pressure acting on a membrane-type LNG CCS is a typical irregular impact load, and the structural response of a tank system induced by sloshing also shows very complex behavior, including fluid structure interaction. Therefore, it is not easy to accurately estimate the sloshing impact pressures and resulting structural response. Moreover, a huge time consuming process to deal with the enormous pressure data obtained during a model tank test and the following structural analysis would be inevitable. To reduce the computation time for structural analysis, in this study, a rational structural modeling strategy was considered, and a simplified scheme to analyze the dynamic structural responses of an LNG CCS was introduced, which was based on the concept of the linear combination of the triangular response functions obtained by a transient response analysis of structures under unit triangular impact pressure. A structural analysis of a real Mark III membrane type insulation system under the sloshing impact pressure time histories obtained by model tests was performed using the various proposed structural models and simplified analysis scheme. The results were investigated in detail, including the elastic support effects of the hull structure.

Review of New Technologies' Energy Conservation Rate in High-Performance Buildings (High-Performance Buildings 구현을 위한 신기술 연구 동향 및 에너지 절감 효과 평가)

  • Kim, Chul-Ho;Yang, Ja-Kang;Lee, Seung-Eon;Yu, Ki-Hyung;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze the energy performance by applying new technologies for passive and active control. Method: We selected new technologies for passive and active control which are based on formal study by analyzing technology applied to the High-Performance Buildings in various countries. Also, we analyzed energy saving potential for each technologies by breakdown the result of the energy saving rates in detail. Result: For the wall and roof insulating methods, preceding studies showed that up to 21% energy could be saved by improving roof insulation and applying proper outside insulation compared to non-insulation. For the windows and glazing system, preceding studies showed that Low-E glazing system could save up to 11% energy compared to single glazing system. Studies about solar and daylighting controls revealed that effective daylighting dimming control could save 13% of energy compared to uncontrolled situation. Studies on DOAS (Dedicated Outdoor Air System) showed that about 23% energy could be saved compared to standard VAV system. Studies on the active chilled beam showed that about 25% energy could be saved compared to standard VAV system and studies of applying UFAD (Under Floor Air Distribution) could consume 31% less energy than applying overhead system.

A Study on the Algorithm for Detection of Partial Discharge in GIS Using the Wavelet Transform

  • J.S. Kang;S.M. Yeo;Kim, C.H.;R.K. Aggarwal
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.4
    • /
    • pp.214-221
    • /
    • 2003
  • In view of the fact that gas insulated switchgear (GIS) is an important piece of equipment in a substation, it is highly desirable to continuously monitor the state of equipment by measuring the partial discharge (PD) activity in a GIS, as PD is a symptom of an insulation weakness/breakdown. However, since the PD signal is relatively weak and the external noise makes detection of the PD signal difficult, it therefore requires careful attention in its detection. In this paper, the algorithm for detection of PD in the GIS using the wavelet transform (WT) is proposed. The WT provides a direct quantitative measure of the spectral content and dynamic spectrum in the time-frequency domain. The most appropriate mother wavelet for this application is the Daubechies 4 (db4) wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, is very well suited to detecting high frequency signals of very short duration, such as those associated with the PD phenomenon. The proposed algorithm is based on utilizing the absolute sum value of coefficients, which are a combination of D1 (Detail 1) and D2 (Detail 2) in multiresolution signal decomposition (MSD) based on WT after noise elimination and normalization.