• 제목/요약/키워드: insulation

검색결과 4,499건 처리시간 0.036초

함침기법에 따른 인버터 구동 유도전동기 고정자 권선의 절연성능 평가 (Evaluation of Insulation Performance for Stator Winding of the Inverter Driven Induction Motor According to Impregnation Methods)

  • 황돈하;강동식;이인우;김동희;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.487-492
    • /
    • 2006
  • Inverter driven induction motors with high speed switching and advanced PWM techniques are widely used for variable speed applications. Recently, the insulation failures of stator winding have attracted much concern due to high dv/dt of IGBT PWM inverter output. In this paper, the detailed insulation test results of 26 low-voltage induction motors are presented. Six different types of insulation techniques are applied to 26 motors. The insulation characteristics are analyzed with partial discharge, inception voltage, AC current, and dissipation factor tests. Also, breakdown tests by high voltage pulses are performed. From the above test data the effects due to different wires and insulation techniques on the insulation characteristics of low-voltage induction motors are compared and analyzed. The insulation technique to enhance the insulation strength is suggested from the test results.

  • PDF

Electrical Insulation Breakdown Strength in Epoxy/Spherical Alumina Composites for HV Insulation

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권2호
    • /
    • pp.105-109
    • /
    • 2013
  • In order to develop high voltage (HV) insulation materials, epoxy/spherical alumina composites with two different particle sizes (in ${\mu}m$) were prepared and a dynamic mechanical analysis (DMA) and electrical insulation breakdown strength test were carried out in sphere-sphere electrodes and the data were estimated using Weibull statistical analysis. Alumina content varied from 50 to 70 wt%. The electrical insulation breakdown strength for epoxy/alumina (50 wt%) was 44.0 kV/1 mm and this value decreased with increasing alumina content. The effects of insulation thickness and alumina particle size on the insulation breakdown strength were also studied. The insulation thickness varied from 1 mm to 3 mm, and the particle sizes were 7.3 or $40.3{\mu}m$.

다층형 단열재를 사용한 영구거푸집의 처짐 특성 (Deflection Characteristics of Permanent Formwork Using Multi-layer Insulation)

  • 류화성;신상헌;송성용;김득모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.130-131
    • /
    • 2019
  • As part of recent low-energy policies, thermal insulation standards for buildings are being tightened every year. In addition, the conventional styrofoam insulating material has a problem that the thickness of the heat insulating material to achieve a standard heat permeability is rapidly increased. Due to the thick insulation, there is a high risk of spreading vulnerable structures such as fire due to lack of space between buildings. On the other hand, the method of using the insulation as a formwork is known to be excellent cost saving effect through the reduction of the formwork usage and the simplification of the external insulation work. In order to solve this problem, this study aims to fabricate a multi-layered insulator that combines high-performance phenolic foam insulation and styrofoam insulation and evaluate the deflection characteristics for use as formwork.

  • PDF

산화마그네슘 및 재유화형 분말수지를 사용한 시멘트계 불연단열재의 단열특성 (Insulation Property of Cement-based Non-combustible Inorganic Insulation Using MgO and Redispersible Polymer Powder)

  • 손배근;송훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.120-121
    • /
    • 2021
  • The organic insulation material has excellent thermal insulation property, but it is difficult to expect fire stability, and semi inorganic insulation only delays combustible hour but it is difficult to expect fire stability. In this study, thermal insulation property of cement-based non-combustible inorganic insulation using cement and non combustible materials and redispersible polymer powder was studied. As a result of the experiment, the thermal insulation property decreased as the use of redispersible polymer powder increased, but the heat insulation property improved when using the appropriate amount.

  • PDF

고압회전기 절연진단 및 수명평가 기술현황 (A technology State of Life Estimation and Insulation Diagnosis for High Voltage Rotating Machine)

  • 최영찬;왕종배;김기준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.31-35
    • /
    • 2000
  • We worried about the technology difference between our company and the advanced company at present motor market and are asked to set up the independent coil insulation system to accumulate insulation technology data. And to export our products at oversee market, we are asked to the evaluation of insulation performance to show our product excellence. In this study, we evaluated the insulation system of our motor, and studied the insulation diagnosis technology systematically to do site diagnosis. We are now accumulating the measured data. And also to reduce the initial insulation failure, we performed the insulation characteristic test and acquired the data to evaluate the initial soundness. We are doing the improvement of the insulation system. And also these data were used to new product development as very useful data, also will be used in the insulation deterioration diagnosis to estimate the remained life time which is very important data for the maintenance management. As the result, we were able to get our product reliability.

  • PDF

Physical Properties of Cement System Insulation Using Blast Furnace Slag

  • Seo, Sung Kwan;Park, Jae Wan;Cho, Hyeong Kyu;Chu, Yong Sik
    • 한국세라믹학회지
    • /
    • 제55권1호
    • /
    • pp.61-66
    • /
    • 2018
  • In this study, fabrication method of inorganic insulation were studied to reduce $CO_2$ from buildings. Main materials for inorganic insulation were used cement, blast furnace slag and aluminum powder as foaming agent. Mixing ratio of cement and slag was controlled and physical properties of inorganic insulation were analyzed. When inorganic insulation was fabricated using cement and slag, expanded slurries were not sunken and hardened normally. Pore size was 0.5 - 2 mm; mean pore size was about 1mm in inorganic insulation. Compressive strength of inorganic insulation increased with curing time and increased slightly with cement fineness. However, specific gravity decreased slightly with curing time; this phenomenon was caused by evaporation of adsorptive water. When inorganic insulation was dried at $60^{\circ}C$, compressive strength was higher than that of undried insulation. The highest compressive strength was found with a mixture of cement (50%) and slag (30%) in inorganic insulation. Compressive strength was 0.32 MPa, thermal conductivity was 0.043 W/mK and specific gravity was $0.12g/cm^3$.

건식 유리섬유 심재를 사용한 진공단열재의 단열특성에 관한 연구 (A Study on the Thermal Insulation Performance of Vacuum Insulation Panel Using Dry Processing Glass Fiber Core)

  • 유채중;김민철;고성석
    • 대한건축학회논문집:구조계
    • /
    • 제35권6호
    • /
    • pp.121-128
    • /
    • 2019
  • There is a big move to build zero-energy buildings in the form of passive houses that reduce energy waste worldwide. Korea has set a goal of reducing its greenhouse gas emissions by 37% by 2030 through the activation of green buildings, such as strengthening the energy levels of new buildings and improving the energy efficiency of existing buildings. The use of insulation with high insulation performance is one of the key technologies to realize this, and vacuum insulation is the next generation insulation that blocks the energy flow of the building. In this study, we measured the bonding structure of dry and wet processing glass fiber core materials and compared the insulation performance of vacuum insulation panel. In addition, the insulation performance of vacuum insulation panel was measured according to the thickness of the laminated core. It can be confirmed that the lamination structure of the core and the lamination thickness are important factors for the heat insulating performance of the vacuum insulating panel.

국내 섬유질 단열재의 내화성능에 관한 연구 (A Study on the Fire Resistance of Korean Cellulose Insulation)

  • 권영철;황정하;유형규
    • 한국태양에너지학회 논문집
    • /
    • 제28권4호
    • /
    • pp.10-16
    • /
    • 2008
  • The fire resistance of thermal insulation and interior finishing materials is recently much emphasized after the fire accident at the Icheon Cold Store in January 2008. Three kinds of thermal insulation are used in buildings. They are Organic, Non-organic and cellulosic insulation. Organic insulation such as polystyrene foam board and urethane foam has high thermal resistance but it has no fire resistance. While non-organic insulation such as rockwool and glassfiber has high fire resistance, it has lower thermal resistance than organic insulation. Cellulose insulation is primarily manufactured from recycled newsprint or cardboard using shredders and fiberizers. Despite of its environmental friendliness and high thermal resistivity, its domestic use has not much increased because of the prejudice that paper can easily burn. However, the cellulose insulation as a product is about 80 wt.% cellulosic fiber and 20 wt.% chemicals, most of which are fire retardants such as boric acid and ammonium sulfate. It is required to secure its fire safety for more consumption as a building insulation in Korea. Therefore, this study investigates the fire resistance of Korean cellulose insulation according to the rate of fire retardant and finally presents the optimum rate of fire retardant in cellulose as building insulation. The fire safety test was conducted according to the ASTM C 1485-00. The test results indicate that above 18 wt% of fire retardant is necessary to secure the fire safety of cellulose insulation.

고압전동기 절연진단 해석 (II) (Analysis of Insulation Diagnostic Test for High Voltage motor (II))

  • 이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2107-2109
    • /
    • 1999
  • The insulation diagnostic tests was performed at local thermal power plants high voltage motor. The insulation diagnostic tests include measurements of insulation resistance, polarization index, AC current, $tan{\delta}$, partial discharges. This paper describes Insulation characteristics for high voltage motor which located by inside and outside.

  • PDF

한국 남성용 단일의복의 앙상블 조합시의 온열특성 변화에 관한 연구 - 무풍, 풍속환경하에서 - (A Study on Changes in Thermal Performances in Ensembles Made up of Single Garments Marketed for Korean Men - In Still and Dynamic Air Conditions -)

  • 송민규;권서윤;정현미
    • 한국의류산업학회지
    • /
    • 제14권4호
    • /
    • pp.660-668
    • /
    • 2012
  • The purpose of this study is to analyze the thermal characteristics of garments marketed for Korean males and to investigate the influence of each garment on ensemble, by measuring their insulation values(clo) using thermal manikins. The results are as follows. The total insulations(clo) of ensembles for S/S seasons are between 1.46 and 2.6 clo, with the mean of 2.12 clo. The insulation in the still air condition is 1.23 clo, which means a decrease of 42% compared to the total insulation of all the component garments. The insulation of ensembles for S/S seasons in the dynamic air condition decreased by 46.8%, compared to the still air condition. The total insulation(clo) of ensembles for F/W seasons is between 3.84 and 7.36 clo with the mean of 4.74 clo. The insulation in the still air condition is 2.26 clo, which means a decrease of 53.6% compared to the total insulation of all the component garments. The insulation of ensembles for F/W seasons in the dynamic air condition decreased by 36.2%, compared to the still air condition. As the clo value of each component garment gets higher, the insulation of ensembles gets higher. Especially, the insulation of ensembles was more influenced by outer wear than inner wear. The insulation of ensembles could be predicted by the insulation of outerwear better.