• 제목/요약/키워드: insulating breakdown

검색결과 266건 처리시간 0.021초

자동차 점화코일용 절연유의 전기적 특성 (Electrical properties of insulating oils for automobile ignition coil)

  • 신종열;홍진웅
    • 한국자동차공학회논문집
    • /
    • 제7권5호
    • /
    • pp.172-177
    • /
    • 1999
  • In this paper, the physical and electrical properties of the synthetic fluids No. 2 class Ⅶ used the insulating oils for automobile ignition coil are studied. Also, benzotriazole(BTA) as the streaming electrification suppressant additive is added to the oil, and the change of physical and electrical properties due to different BTA concentration is investigated. To investigate the electrical characteristics, the breakdown strength of each specimen by an experiment for AC breakdown and the changes of conductivity by measuring volume resistivity are analyzed. It is considered that the effective content of BTA as charge suppressant additive is about 10[ppm] from the results of AC breakdown and volume resistivity test.

  • PDF

전극 형태와 전극 간 거리에 따른 전기적 특성 분석 (Electrical Characteristics Analysis According to Electrode Shape and Distance Between Electrodes)

  • 김태희;이순형;황미용;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제36권4호
    • /
    • pp.408-412
    • /
    • 2023
  • In this paper, in order to analyze high electrical insulation and cooling performance using mineral oil, the liquid insulating oil was changed in electrode shape and distance between electrodes to compare and analyze electrical characteristics according to equal electric field, quasi-equivalent electric field, and unequal electric field. As a result, the breakdown voltages were 36,875 V and 36,875 V in the form of sphere-sphere and plate-plate electrodes with equal electric fields. The breakdown voltage was 31,475 V in the sphere-plate electrode type, which is a quasi-equilibrium field, and the breakdown voltage was 28,592 V, 27,050 V, and 22,750 V in the needle-needle, sphere-needle, and needle-plate electrode types, which are unequal fields. Through this, it is possible to know the difference in breakdown voltage according to the type of electric field. The more equal the field, the higher the breakdown voltage, and the more unequal field, the lower the breakdown voltage. The difference in insulation breakdown voltage could be seen depending on the type of electric field, the insulation breakdown voltage was higher for the more equal electric field, and the insulation breakdown voltage was lower for the more unequal electric field. Also, it was confirmed that the closer the distance between the electrodes, the higher the insulation breakdown voltage, the higher the insulation breakdown current, and the insulation breakdown voltage and the insulation breakdown current were proportional.

고온초전도 케이블의 응용을 위한 PPLP의 절연파괴 특성연구 (Study on the Breakdown Performance of Synthetic Polypropylene Laminated Paper for Application of a HTS Cable)

  • 곽동순;김영석;김해종;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.65-68
    • /
    • 2003
  • In this paper, we researched breakdown characteristics of paper/liquid nitrogen composite insulation system for application of a high temperature superconducting cable. And, we have studied the AC breakdown performance of paper/ice composite insulating system immersed in liquid nitrogen. The electric strength in this paper/ice composite system is higher than that of paper/liquid nitrogen system. Furthermore this system shows a self-healing type breakdown behavior. Among the many kinds of liquid to be immersed and frozen to the ice, deionized water gives the highest electric breakdown strength. The paper/ice composite insulation system is thought to be one of good candidate for the electrical insulating system at cryogenic temperature.

  • PDF

거칠기에 따른 반도전-절연 계면층에서 접착특성과 절연성능 (Adhesion and Electrical Performance by Roughness on Semiconductive-Insulation Interface Layer of Silicone Rubber)

  • 이기택;황선묵;홍주일;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.78-81
    • /
    • 2004
  • In this paper, the effect of adhesion properties of semiconductive-insulating interface layer of silicone rubber on electrical properties was investigated. Surface structure and adhesion of semiconductive silicon rubber by surface asperity was obtained from SEM and T-peel test. In addition, ac breakdown test was carried out for elucidating the change of electrical property by roughness treatment. From the results, Adhesive strength of semiconductive-insulation interface was increased with surface asperity. Dielectric breakdown strength by surface asperity decreased than initial Specimen, but increased from Sand Paper #1200. According to the adhesional strength data unevenness and void formed on the silicone rubber interface expand the surface area and result in improvement of adhesion. Before treatment Sand Paper #1200, dielectric breakdown strength was decreased by unevenness and void which are causing to have electric field mitigation small. After the treatment, the effect of adhesion increased dielectric breakdown strength. It is found that ac dielectric breakdown strength was increased with improving the adhesion between the semiconductive and insulating interface.

  • PDF

케이블 접속재 부분방전 특성에 미치는 보이드의 영향 (Influence of Partial Discharge Properties due to Void in Cable Joint Parts)

  • 신종열;홍진웅
    • 한국안전학회지
    • /
    • 제18권3호
    • /
    • pp.69-74
    • /
    • 2003
  • To investigate the partial discharge and electric field distribution in cable joint parts, we measured the partial discharge and electric field in specimen. The specimens which cross-linked polyethylene(XLPE) and ethylene propylene diene ethylene(EPDM) are used to insulating material for underground cable md cable jointing parts. The polymers are used to insulating material in switchgear which is a kind of transformer equipment and in ultra-high voltage cable. Its using is increasing gradually, the electrical insulation properties are not only excellent but also mechanical property is excellent. And because it is possible to be made void of several type in insulator while it is produced, which the electrical field distribution is changed by void, it has a critical influence to insulator performance. The underground cable is connecting by the jointing material, insulating breakdown and the electric ageing which are caused by several mixing impurity and the damage of cable insulator layer, which reduced the life of cable while intermediate joint kit is connected. Therefore, the computer simulation is used to estimating insulator performance, XLPE is used to the insulating material of ultra-high voltage cable and EPDM is used to insulator layer in joint material kit, and which are produced as specimen. And it is analyzed the electric field concentrating distribution and partial discharge by modeling of computer simulation in void and cable joint kit.

Breakdown Characteristics and Lifetime Estimation of Rubber Insulating Gloves Using Statistical Models

  • Kim, Doo Hyun;Kang, Dong Kyu
    • International Journal of Safety
    • /
    • 제1권1호
    • /
    • pp.36-42
    • /
    • 2002
  • This paper is aimed at predicting the life of rubber insulating gloves under normal operating stresses from relatively rapid test performed at higher stresses. Specimens of rubber insulating gloves are subject to multiple stress conditions, i.e. combined electrical and thermal stresses. Two modes of electrical stress, step voltage stress and constant voltage stress are used in specimen aging. There are two types of test for electrical stress in this experiment: the one is Breakdown Voltage (BDV) test under step voltage stress and thermal stress and the other is lifetime test under constant voltage stress and temperature stress. The ac breakdown voltage defined as the break-down point of insulation that leakage current excesses a limit value, l0mA in this experiment, is determined. Because the very high variability of aging data requires the application of statistical model, Weibull distribution is used to represent the failure times as the straight line on Weibull probability paper. Weibull parameters are deter-mined by three statistical methods i.e. maximum likelihood method, graphical method and least squares method, which employ SAS package, Weibull probability paper and FORTRAN, respectively. Two chosen models for predicting the life under simultaneous electrical and thermal stresses are inverse power model and exponential model. And the constants of life equation for multistress aging are calculated using numerical method, such as Gauss Jordan method etc.. The completion of life equation enables to estimate the life at normal stress based on the data collected from accelerated aging test. Also the comparison of the calculated lifetimes between the inverse power model and the exponential model is carried out. And the lifetimes calculated by three statistical methods with lower voltage than test voltage are compared. The results obtained from the suggested experimental method are presented and discussed.

절연 파괴 데이터를 이용한 에폭시 복합체의 절연 신뢰도 평가 (Evaluation of Insulating Reliability in Epoxy Composites using Dielectric Breakdown Data)

  • 박건호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.114-118
    • /
    • 2005
  • In this study, the DC dielectric breakdown of epoxy composites used for molding material was experimented and then its data were simulated by Weibull distribution equation. From the analysis of Weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5[kV/mm].

  • PDF

OF 케이블 절연유의 특성 변화에 따른 경년열화진단 (The Aging Diagnosis of OF Cable Insulation Oil by Characteristic Change)

  • 윤구섭;정우성;김철운;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.35-40
    • /
    • 1997
  • As demand of electric power are growing and transmission line limited owing to enlargement of the downtown area The eonfidence of underground transmission cable which shows gradual growth are high. It is found whether insulating ability is good or not. In this paper, The exper iment result is shown that the fall of insulating ability and take preventive measure through the analysis of tans, water content, dielectric breakdown voltage, total acid number, volume resistivity , and gas in the oil in an accordance with the characteristic change of oil used very much for insulating oil of cable.

  • PDF

평등전계중의 절연유에 미치는 첨가물의 영향 (A study on the effect of additives in insulating oil under uniform electric field)

  • 국상훈
    • 전기의세계
    • /
    • 제30권6호
    • /
    • pp.357-365
    • /
    • 1981
  • When electronegative gas SF$_{6}$ is dissolved and charged with insulating oil, the effect caused in the process by electronegative characteristic is studied and also the pressure effect caused by electronegative SF$_{6}$ acting on the liquid-level is examined respectively. When inert gas Ar is used to find a pressure effect acting on the liquid-level, its effect on dielectric strength is considered in the experiment. With three kinds of impulse voltage different in the duration of wave front and wave tail, a brief experiment if carried out ot see the effects on the dielectric breakdown characteristic as the wave is changing; either if I$_{2}$ and SF$_{6}$ are added to the insulating oil, or if the oil pressure is increased by Ar the dielectric strength becomes great and the longer the duration of wave front is, the greater the increase of the breakdown voltage, because I$_{2}$ added by a small quantity brings about some hirderance in the formation of gas phase. Likewise, the greater the changed pressure is, the greater the incerase of the breakdown voltage. When SF$_{6}$ is charged, the electronegative characteristic is prevailing at the time of low balanced pressure, and the pressure effect at the time of high balanced pressure.ressure.

  • PDF

도포된 오일의 변화에 따른 Epoxy/EPDM 계면의 교류 절연파괴 특성에 관한 연구 (A Study on the AC Interfacial Breakdown Properties of the Interface between Epoxy/EPDM with Variation of the Spread Oil)

  • 배덕권;정일형;오재한;박우현;이기식;김충혁;이준웅
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권8호
    • /
    • pp.445-450
    • /
    • 2000
  • Many successful developments and microscopic studies have been made on the high quality insulating materials. However, a little attention have given to the macroscopic interface in HV(High Voltage) insulating systems. In this study, AC interfacial breakdown strength and V-t characteristic of the interface between Epoxy/EPDM(ethylene propylene diene terpolymer) are investigated. Electrode system is designed to reduce the charges from electrodes and to have the tangential potentials along the interface between Epoxy/EPDM by FEM(finite elements method). The AC breakdown strength is observed when HV is given to the interface. It is shown that AC interfacial breakdown strength is improved by increasing interfacial pressure and oiling. In particular, it was saturated at certain interfacial pressure level. V-t characteristic is able to extend to the life time of the interface between Epoxy/EPDM. Oiling also plays a good roll in prolongation of the life time.

  • PDF