DEVELOPMENT OF OZONE DETECTOR FOR KSR-III AND PRELIMINARY TEST RESULTS (과학 로켓 3호용 오존 측정기 개발 및 초기 모델 시험 결과)

  • Hwang, Seung-Hyun;Kim, Jhoon;Kim, Jun-Kyu;Lee, Soo-Jin;Park, Jeong-Joo;Cho, Gwang-Rae
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.2
    • /
    • pp.277-284
    • /
    • 2000
  • KARI(Korea Aerospace Research Institute) has measured the ozone density profiles over the Korean Peninsular since the launch of the Korean Sounding Rocket-I (KSR-I) in 1993. The purpose of ozone measurements is to obtain the stratospheric and mesospheric vertical ozone density profiles over the Korean Peninsular with solar UV radiometers. With the visible channel of the radiometer, the attitude variation of the rocket was corrected and compensated. Developed system is based on ozone detector designs onboard the KSR-I and KSR-II. We discuss the development of ozone detector which will be onboard the KSR-III and its circuit and vibration test results for EM model.