• Title/Summary/Keyword: instrumental neutron activation analysis

Search Result 46, Processing Time 0.019 seconds

Determination of Trace Elements in Airborne Particulates by Instrumental Neutron Activation Analysis (중성자 방사화분석법을 이용한 대기분진시료의 정량)

  • Chung, Yong-Sam;Chung, Young-Ju;Jeong, Eui-Sik;Cho, Seung-Yeon
    • Nuclear Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.234-247
    • /
    • 1995
  • Trace elements in airborne particulates were analyzed by instrumental neutron activation analysis (INAA) under the optimum analytical condition. Neutron irradiation for sample was done at the irradiation hole(neutron flux 1$\times$10$^{13}$ n/$\textrm{cm}^2$.s) of TRIGA MARK-III research reactor in the Korea Atomic Energy Research Institute. For the verification of the analytical method, NIST SRM-1648 and NIES CRM No.8 ore chosen and analyzed. The accuracy and precision of the analysis of 40 and 24 trace elements in the samples were compared with the certified and reported values, respectively. The analytical method was found to be reliable enough when the analytical data of NIES sample were compared with those of different counties. In the analytical result of two or both of standard reference materials, relative standard deviation wes within the 15% except a few elements and the relative error was within the 10%. We used this method to analyze 30 trace elements in airborne particulates collected with the high volume air sampler(PM-10) at too different locations and also confirmed the possibility to use this method as a routine monitoring tool to find out environmental pollution sources.

  • PDF

Intercomparison and Determination of Trace Elements in Urban Dust by Neutron Activation Analysis (중성자방사화분석법을 이용한 대기분진중의 미량원소 비교분석)

  • Chung, Yong-Sam;Moon, Jong-Hwa;Kim, Sun-Ha;Park, Kwang-Won;Kang, Sang-Hun
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.179-188
    • /
    • 2000
  • Trace elements in air samples artificially loaded on filters with urban dust and the bulk material of urban dust as an environmental sample were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Dust, SRM 1648) of the National Institute of Standard and Technology was used for the analytical quality control. The relative error for 37 elements was less than 15% and the standard deviation was less than 10%. 29 elements in the urban dust and 21 elements in the loaded filter sample were determined respectively. To evaluate the proficiency and reliability of the measurement, data intercomparison was performed and 39 analytical laboratories participated in the analysis using different analytical methods; neutron activation analysis, particle induced X-ray emission analysis, X-ray fluorescence analysis and atomic absorption spectrometry. Z-scores were calculated using the standard deviation of the laboratorie's mean as target standard deviation, and a good result was obtained that the values fall between -1 and +1 except some elements.

  • PDF

A STUDY ON KOREAN ANTHRACITE BY INSTRUMENTAL NEUTRON ACTIVATION ANALYSIS

  • Kim, N.B.;Woo, H.J.;Lee, K.Y.;Hong, W.;Chun, S.K.;Park, K.S.
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.477-482
    • /
    • 1994
  • By the instrumental neutron activation analysis using two comparators of gold and cobalt, 31 elements have been anlalyzed in anthracites collected from two main coal-fields in Korea. The average concentrations and ranges of the elements were obtained with the elemental difference between two coal-fields. The trends of rare-earth elemental distribution and vertical elemental distribution are also given.

  • PDF

The Review of Instrumental Neutron Activation Analysis by $k_0$-standardization method ($k_0$-표준화방법에 의한 기기중성자방사화 분석법의 고찰)

  • Moon, Jong-Hwa;Chung, Yong-Sam;Kim, Sun-Ha
    • Analytical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.1075-1081
    • /
    • 2001
  • Instrumental Neutron Activation Analysis as a representative method of nuclear analytical technique, has advantages of non-destructive, simultaneous multi-element analysis with the characteristics of absolute measurement method. Up to date, $k_0$-quantitative method which is accurate, convenient and user-friendly, has been generalized world-widely. In this study, it is intented to introduce the general concept of $k_0$-method and to measure $k_0$-parameters for the future implementation to our NAA system. For this objectives, the definition of relevant factors for the quantitative analysis and the equation for the experimental determination of parameters such as $Q_0$(${\alpha}$) and f were summarized. Furthermore, a foundation for the $k_0$-standardization method was prepared through the measurement of ${\alpha}$ and f-value which depend on the specific character of irradiation hole at NAA#1-hole of HANARO research reactor.

  • PDF

Quality Control on Neutron Activation Analysis for Urban Dust by the Proficiency Test (비교숙련도 시험을 통한 도시대기분진에 대한 중성자방사화분석법의 품질관리)

  • Moon, Jong-Hwa;Kim, Sun-Ha;Chung, Yong-Sam
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.433-438
    • /
    • 2002
  • Trace elements in two air filters (V-50, P-50) artificially loaded with urban dust provided from IAEA were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Particulate Matter, SRM 1648) of National Institute of Standard and Technology was used for analytical quality control. About 20 elements in both of loaded filter samples were determined. To evaluate inter-laboratory comparison and proficiency test, analytical data were statistically treated with the results which collected from 49 laboratories, 40 countries participated in this study using neutron activation analysis, particle induced X-ray emission, inductively coupled plasma mass spectroscopy, etc,. From the results of statistical treatment, Z-scores are within ${\pm}2$. Furthermore, accuracy and precision of obtained analytical values are passed according to the criteria of the proficiency test. Consequently, it was proved that analytical quality for air dust samples being performed has been controlled properly.

Analysis of Zirconium and Nickel Based Alloys and Zirconium Oxides by Relative and Internal Monostandard Neutron Activation Analysis Methods

  • Shinde, Amol D.;Acharya, Raghunath;Reddy, Annareddy V.R.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.562-568
    • /
    • 2017
  • Background: The chemical characterization of metallic alloys and oxides is conventionally carried out by wet chemical analytical methods and/or instrumental methods. Instrumental neutron activation analysis (INAA) is capable of analyzing samples nondestructively. As a part of a chemical quality control exercise, Zircaloys 2 and 4, nimonic alloy, and zirconium oxide samples were analyzed by two INAA methods. The samples of alloys and oxides were also analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES) and direct current Arc OES methods, respectively, for quality assurance purposes. The samples are important in various fields including nuclear technology. Methods: Samples were neutron irradiated using nuclear reactors, and the radioactive assay was carried out using high-resolution gamma-ray spectrometry. Major to trace mass fractions were determined using both relative and internal monostandard (IM) NAA methods as well as OES methods. Results: In the case of alloys, compositional analyses as well as concentrations of some trace elements were determined, whereas in the case of zirconium oxides, six trace elements were determined. For method validation, British Chemical Standard (BCS)-certified reference material 310/1 (a nimonic alloy) was analyzed using both relative INAA and IM-NAA methods. Conclusion: The results showed that IM-NAA and relative INAA methods can be used for nondestructive chemical quality control of alloys and oxide samples.

Study on Airborne Particulate Matter ($PM_{10}$) Monitoring in Urban and Rural Area by Using Gent SFU Sampler and Instrumental Neutron Activation Analysis (중성자 방사화분석법과 Gent SFU 샘플러를 이용한 도시의 농촌지역의 대기분지($PM_{10}$)관측 연구)

  • 정용삼;문종화;김선하;박광원;강상훈
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.5
    • /
    • pp.453-467
    • /
    • 2000
  • The aim of this research is to collect and characterize fine particles (FPM:$\leq$2.5${\mu}{\textrm}{m}$) and coarse particles (CPM: 2.5~10${\mu}{\textrm}{m}$) using a low volume air sampler provided by the IAEA, at urban (Taejon) and rural area(Wonju) for a period of about two years(April 1996 to May 1998) and to promote a use of nuclear analytical techniques for air pollution studies. For the collection of airborne particulate matter (PM(sub)10), the Gent stacked filter unit sampler and polycarbonate membrane filters were employed. The concentration of trace elements in collected APM samples were determined byu instrumental Neutron Activation Analysis. For validation of the analytical data, internal quality control were implemented by using both the comparison of the analytical results of standard reference materials(NIST SRM 1648) and interlaboratory comparison for proficiency test (NAT-3). The standard uncertainty was less than 15% and Z-score of two samples were within $\pm$1. The monitoring of (PM(sub)10) mass concentration and elemental concentrations were carried out weekly. The average mass concentration of (PM(sub)10) in urban and rural areas were 59.2$\pm$36.5$\mu\textrm{g}$/㎥ and 41.4$\pm$23.7$\mu\textrm{g}$/㎥, respectively. To investigate the emission source, the enrichment factors were calculated for the fine and coarse particle fractions at two sites, respectively and these values were classified for anthropogenic and soil origin elements.

  • PDF

A Study on the Characterization on Some Semiconuctor Materials by Neutron Activation Analysis. Characterization of Semiconductor Silicon

  • Lee Chul;Kwun Oh Cheun;Kim Ho Kun;Lee Jong Du;Chung Koo Soon
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.1
    • /
    • pp.30-32
    • /
    • 1989
  • Traces of nine elements, gold, arsenic, cobalt, chromium, copper, europium, hafnium, sodium and antimony in commercially available silicon crystals were determined by the instrumental neutron activation analysis using the single comparator method. The values of the concentrations of these elements in both single and polycrystals were found to decrease significantly to a low limiting level by simply washing and etching surface contaminants having been introduced during various steps of sample preparation and irradiation. However, the chromium levels in polycrystals were not easily decreased, these depending upon the cutting tools employed. The Sb-doped content in each semiconductor has been compared with the associated quantities such as the concentration and the conductivity range given by the sample donor. Uncertainty in the sodium analysis due to the fission neutron reaction by silicon itself was discussed.

Intercomparison and Determination of Sediment by Instrumental Neutron Activation Analysis (중성자방사화분석을 이용한 퇴적물의 정량 및 비교연구)

  • 정용삼;문종화;정영주;박용준;이길용;윤윤열;이수형;김경태
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.2
    • /
    • pp.116-121
    • /
    • 1998
  • For the application of study on pollution and conservation of environment determination of 33 elemental concetrations in different sediment samples were carried out using instrumental neutron activation analysis (INAA). For verification and evaluation of the analytical method, three standard reference materials (two NIST SRMs and one NRCC CRM) were chosen and the accuracy and precision of the analysis were estimated by comparison to the certified values. Under the optimum condition, the analytical procedure to apply a practical sample was estimated. Neutron irradiation of sample was done at the irradiation facilities (neutron flux, 1-3${\times}$10$\^$13/n/$\textrm{cm}^2$$.$s) of the TRIGA MARK-III and HANARO research reactor in the Korea Atomic Energy Research Institute. In addition, analysis of two IAEA's sediment was performed according to the pre-established analytical method. The analytical results of elements such as Al, As, Co, Cr, Fe, Sb and Zn by INAA were intercompared with those of WD-XRF, ICP-MS and AAS, and are relatively agreed with each other.

  • PDF