• Title/Summary/Keyword: instrument and equipment

Search Result 220, Processing Time 0.034 seconds

Status of Development of Pyroprocessing Safeguards at KAERI (한국원자력연구원 파이로 안전조치 기술개발 현황)

  • Park, Se-Hwan;Ahn, Seong-Kyu;Chang, Hong Lae;Han, Bo Young;Kim, Bong Young;Kim, Dongseon;Kim, Ho-Dong;Lee, Chaehun;Oh, Jong-Myeong;Seo, Hee;Shin, Hee-Sung;Won, Byung-Hee;Ku, Jeong-Hoe
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.3
    • /
    • pp.191-197
    • /
    • 2017
  • The Korea Atomic Energy Research Institute (KAERI) has developed a safeguards technology for pyroprocessing based on the Safeguards-By-Design (SBD) concept. KAERI took part in a Member-State Support Program (MSSP) to establish a pyroprocessing safeguards approach. A Reference Engineering-scale Pyroprocessing Facility (REPF) concept was designed on which KAERI developed its safeguards system. Recently the REPF is being upgraded to the REPF+, a scaled-up facility. For assessment of the nuclear-material accountancy (NMA) system, KAERI has developed a simulation program named Pyroprocessing Material Flow and MUF Uncertainty Simulation (PYMUS). The PYMUS is currently being upgraded to include a Near-Real-Time Accountancy (NRTA) statistical analysis function. The Advanced Spent Fuel Conditioning Process Safeguards Neutron Counter (ASNC) has been updated as Non-Destructive Assay (NDA) equipment for input-material accountancy, and a Hybrid Induced-fission-based Pu-Accounting Instrument (HIPAI) has been developed for the NMA of uranium/transuranic (U/TRU) ingots. Currently, performance testing of Compton-suppressed Gamma-ray measurement, Laser-Induced Breakdown Spectroscopy (LIBS), and homogenization sampling are underway. These efforts will provide an essential basis for the realization of an advanced nuclear-fuel cycle in the ROK.

A Study about the Direction and Responsibility of the National Intelligence Agency to the Cyber Security Issues (사이버 안보에 대한 국가정보기구의 책무와 방향성에 대한 고찰)

  • Han, Hee-Won
    • Korean Security Journal
    • /
    • no.39
    • /
    • pp.319-353
    • /
    • 2014
  • Cyber-based technologies are now ubiquitous around the glob and are emerging as an "instrument of power" in societies, and are becoming more available to a country's opponents, who may use it to attack, degrade, and disrupt communications and the flow of information. The globe-spanning range of cyberspace and no national borders will challenge legal systems and complicate a nation's ability to deter threats and respond to contingencies. Through cyberspace, competitive powers will target industry, academia, government, as well as the military in the air, land, maritime, and space domains of our nations. Enemies in cyberspace will include both states and non-states and will range from the unsophisticated amateur to highly trained professional hackers. In much the same way that airpower transformed the battlefield of World War II, cyberspace has fractured the physical barriers that shield a nation from attacks on its commerce and communication. Cyberthreats to the infrastructure and other assets are a growing concern to policymakers. In 2013 Cyberwarfare was, for the first time, considered a larger threat than Al Qaeda or terrorism, by many U.S. intelligence officials. The new United States military strategy makes explicit that a cyberattack is casus belli just as a traditional act of war. The Economist describes cyberspace as "the fifth domain of warfare and writes that China, Russia, Israel and North Korea. Iran are boasting of having the world's second-largest cyber-army. Entities posing a significant threat to the cybersecurity of critical infrastructure assets include cyberterrorists, cyberspies, cyberthieves, cyberwarriors, and cyberhacktivists. These malefactors may access cyber-based technologies in order to deny service, steal or manipulate data, or use a device to launch an attack against itself or another piece of equipment. However because the Internet offers near-total anonymity, it is difficult to discern the identity, the motives, and the location of an intruder. The scope and enormity of the threats are not just focused to private industry but also to the country's heavily networked critical infrastructure. There are many ongoing efforts in government and industry that focus on making computers, the Internet, and related technologies more secure. As the national intelligence institution's effort, cyber counter-intelligence is measures to identify, penetrate, or neutralize foreign operations that use cyber means as the primary tradecraft methodology, as well as foreign intelligence service collection efforts that use traditional methods to gauge cyber capabilities and intentions. However one of the hardest issues in cyber counterintelligence is the problem of "Attribution". Unlike conventional warfare, figuring out who is behind an attack can be very difficult, even though the Defense Secretary Leon Panetta has claimed that the United States has the capability to trace attacks back to their sources and hold the attackers "accountable". Considering all these cyber security problems, this paper examines closely cyber security issues through the lessons from that of U.S experience. For that purpose I review the arising cyber security issues considering changing global security environments in the 21st century and their implications to the reshaping the government system. For that purpose this study mainly deals with and emphasis the cyber security issues as one of the growing national security threats. This article also reviews what our intelligence and security Agencies should do among the transforming cyber space. At any rate, despite of all hot debates about the various legality and human rights issues derived from the cyber space and intelligence service activity, the national security should be secured. Therefore, this paper suggests that one of the most important and immediate step is to understanding the legal ideology of national security and national intelligence.

  • PDF

Measurement and Quality Control of MIROS Wave Radar Data at Dokdo (독도 MIROS Wave Radar를 이용한 파랑관측 및 품질관리)

  • Jun, Hyunjung;Min, Yongchim;Jeong, Jin-Yong;Do, Kideok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.2
    • /
    • pp.135-145
    • /
    • 2020
  • Wave observation is widely used to direct observation method for observing the water surface elevation using wave buoy or pressure gauge and remote-sensing wave observation method. The wave buoy and pressure gauge can produce high-quality wave data but have disadvantages of the high risk of damage and loss of the instrument, and high maintenance cost in the offshore area. On the other hand, remote observation method such as radar is easy to maintain by installing the equipment on the land, but the accuracy is somewhat lower than the direct observation method. This study investigates the data quality of MIROS Wave and Current Radar (MWR) installed at Dokdo and improve the data quality of remote wave observation data using the wave buoy (CWB) observation data operated by the Korea Meteorological Administration. We applied and developed the three types of wave data quality control; 1) the combined use (Optimal Filter) of the filter designed by MIROS (Reduce Noise Frequency, Phillips Check, Energy Level Check), 2) Spike Test Algorithm (Spike Test) developed by OOI (Ocean Observatories Initiative) and 3) a new filter (H-Ts QC) using the significant wave height-period relationship. As a result, the wave observation data of MWR using three quality control have some reliability about the significant wave height. On the other hand, there are still some errors in the significant wave period, so improvements are required. Also, since the wave observation data of MWR is different somewhat from the CWB data in high waves of over 3 m, further research such as collection and analysis of long-term remote wave observation data and filter development is necessary.

Study for the Deficiency and Excessiveness Diagnosis in the Front Point by Elastic State (모혈(募穴)의 탄력(彈力) 상태(狀態) 측정(測定)에 의한 허실(虛實) 진단(診斷) 연구(硏究))

  • Na, Chang-Su;Yoon, Yeo-Choong;Park, Hyun-Cheal;Lee, Dong-Kyu;Choi, Chan-Hern;Jang, Kyung-Sun;So, Cheal-Ho
    • Journal of Acupuncture Research
    • /
    • v.17 no.1
    • /
    • pp.27-41
    • /
    • 2000
  • The meridian system is the most essential and basic connecting structure that maintains the vital activities of viscera and bowels by connecting them with each part of body's surface. Doctors can understand the healthy condition, and the region and deficiency-excessiveness of disease by observing the condition of Qi flowing. Deficiency and excessiveness could be differentiated by various symptoms expressed in meridian system. Especially there could be several clues like pain, heat-cold, protuberance-depression, change of color and shine in the line of channel leads to the judgment of deficiency-excessiveness The diagnosis of deficiency and excessiveness can be generalized by quantification of elastic status in skin surface along the meridian system. By comparing data from measurement of elastic condition with those from traditional deficiency and excessiveness, it could be utilized for the development of oriental medicine. All biological activities in the human body are based on meridian system according to the oriental medicine. Also the meridian system is viewed as basic and essential structure connecting internal viscera and each part of body. The areas of expressed channel phenomena are muscle to bone, muscle to muscle and bone to bone. These areas are called depression where meridian system is present and any changing state on those points can be measured. It could be difficult in diagnosing the reaction of meridian system because doctor can depend on his own judgment. Therefore, it is necessary to quantify and indexate channel reactions. To quantify the channel reactions, specially manufactured instrument was used to quantify the protuberance and depression to differentiate the deficiency and excessiveness. The results follow as below; 1. The elastic index measurement by the equipment proved a pattern of agreement showing the values that ranged within standard deviation 0.05kgf/cm throughout the experiment except few cases' measurement in CV-17. 2. To evaluate the state of deficiency & excessiveness of elastic index measurements in frontal point, elastic index measurements in the front paint were compared to the elastic index measured surrounding the point within 2.5 cm. Such result of indexing procedure was closely matched to the concept of palpitation. 3. If the elastic index values in the surrounding front point closely located to the elastic index values in the front point, the judgement on the state of deficiency and excessiveness was delayed. Otherwise, it was judged as deficiency or excessiveness. 4. Out of total 12 cases of comparing the elastic index values to the elastic index values in the surrounding front point, Three to nine front points were judged as either in the state of deficiency or excessiveness. 5. Among the nine front points judged as either in the state of deficiency or excessiveness, Four cases were matched to the electric index measured by EAV that evaluating the internal organs by five different phases. If more clinical cases are accumulated, it is expected to systematically theorize and improve the concept of deficiency and excessiveness in the internal organs using the front point.

  • PDF

Verification of Multi-point Displacement Response Measurement Algorithm Using Image Processing Technique (영상처리기법을 이용한 다중 변위응답 측정 알고리즘의 검증)

  • Kim, Sung-Wan;Kim, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.297-307
    • /
    • 2010
  • Recently, maintenance engineering and technology for civil and building structures have begun to draw big attention and actually the number of structures that need to be evaluate on structural safety due to deterioration and performance degradation of structures are rapidly increasing. When stiffness is decreased because of deterioration of structures and member cracks, dynamic characteristics of structures would be changed. And it is important that the damaged areas and extent of the damage are correctly evaluated by analyzing dynamic characteristics from the actual behavior of a structure. In general, typical measurement instruments used for structure monitoring are dynamic instruments. Existing dynamic instruments are not easy to obtain reliable data when the cable connecting measurement sensors and device is long, and have uneconomical for 1 to 1 connection process between each sensor and instrument. Therefore, a method without attaching sensors to measure vibration at a long range is required. The representative applicable non-contact methods to measure the vibration of structures are laser doppler effect, a method using GPS, and image processing technique. The method using laser doppler effect shows relatively high accuracy but uneconomical while the method using GPS requires expensive equipment, and has its signal's own error and limited speed of sampling rate. But the method using image signal is simple and economical, and is proper to get vibration of inaccessible structures and dynamic characteristics. Image signals of camera instead of sensors had been recently used by many researchers. But the existing method, which records a point of a target attached on a structure and then measures vibration using image processing technique, could have relatively the limited objects of measurement. Therefore, this study conducted shaking table test and field load test to verify the validity of the method that can measure multi-point displacement responses of structures using image processing technique.

The Effects of Bilateral Chewing Exercise on Occlusion Force and Masseter Muscle Thickness in Community-Dwelling Elderly (양측저작 운동이 지역사회 거주 노인의 교합력과 깨물근에 미치는 효과)

  • Hong, Jun-Yong;Jung, Young-Jin;Kim, Min-Ji;Hwang, Se-Hyun;Park, Ji-Su;Lee, Gi-Hyoun;Kim, Tae-Hoon;Jung, Nam-Hae;Yoon, Tae-Hyung
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.10 no.1
    • /
    • pp.31-38
    • /
    • 2020
  • Objective : The purpose of this study is to investigate the effects of bilateral chewing exercise applied for 6 weeks on occlusion force and masseter muscle thickness in the elderly living in the community. Methods : This study recruited 25 community residents. All participants performed bilateral chewing exercise using equipment developed for the purpose of oral chewing exercise. The chewing exercise was divided into isometric and isotonic type and applied for about 20 minutes a day, five times a week for six weeks. For the evaluation, the masseter muscle thickness and the maximum occlusion force were measured three times at three week intervals using a portable ultrasound instrument and an occlusion force gauge. Results : As a result of the change in masseter muscle thickness, baseline, 3 weeks later, and 6 weeks later referred to 7.51±0.43, 7.63±0.44, and 7.83±0.46, respectively (F=3.819, p<.05). The post hoc test resulted in a significance between baseline and 6 weeks later (p=0.023). Similarly, as a result of the change in occlusion force, baseline, 3 weeks later, and 6 weeks later referred to 265±9.22, 268±9.57, and 271.59±10.16, respectively (F=3.031, p<.05). The post hoc test resulted in a significance between baseline and 6 weeks later (p=0.048). Conclusion : This study confirmed that bilateral chewing exercise was effective for increasing masseter muscle thickness and occlusion force in the elderly. Therefore, bilateral chewing exercise can be applied as a therapeutic exercise method for improving oral function.

Economic Analysis of the Livestock Manure Treatment System Using Life-Cycle Cost Technique (LCC 기법을 통한 가축분뇨처리시설의 경제성 분석)

  • Kim, J.H.;Cho, S.H.;Kwag, J.H.;Choi, D.Y.;Jeong, K.H.;Chung, U.S.;Chung, M.S.;Park, S.K.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.sup
    • /
    • pp.61-68
    • /
    • 2011
  • To assess the total cost with all stages of facilities, the feasibility of Life Cycle Cost (LCC) analysis was examined in this study to estimate the livestock manure treatment system and optimal decision making process. For the economic evaluation, the plant/equipment investment and annual operation cost of four Public Livestock Recycling Facilities, whose treatment capacity is 100 ton piggery manure per day, was compared. The initial cost was in the range of 2,699 million won to 3,202 million won, where T and E methods were highest and lowest, respectively. The annual operation cost was in the level of 378 million to 498 million won, which decreased in the following order : T method > J method > E method > B method. For the LCC analysis, 4.7% of interest rate, 3.13% of inflation rate, and 1.52% of net discount rate was considered by the data received from Bank of Korea and Statics Korea in the period of 2000 to 2009. Also, for the calculation of present value factor, the durable years of civil engineering & construction, machinery and electric instrument was 30 years, 10 years and 15 years, respectively. Based on these consideration, operation cost was in the range of 17,570 won/ton to 20,661 won/ton, and E method (17,570 won/ton) was economical and B method (20,661 won/ton) was non-economical. Though initial cost of T method was higher than that of B method, LCC analysis of T method was lower than that of T method due to the lower operation cost. Therefore, LCC analysis, which considers both initial cost and operation cost, is more reasonable evaluation method than either initial cost or annual operation cost. For the change of LCC analysis according to the uncertainty, the sensitivity analysis was carried out using fluctuation magnitude of discount rate in the period of 2000 to 2009. As a result, LCC analysis evaluated by discount rate was stable for the uncertain factors since the cost leadership did not change even though the sensitivity analysis varied. In summary, the economic evaluation using LCC analysis could be an efficient reference to choose the suitable livestock manure treatment plants. Furthermore, standardization of statement calculation for the actual cost analysis should be conducted and more detailed study is necessary to validate this summary. Therefore, the application of comprehensive technology evaluation, which considers LCC analysis, should contribute in obtaining objectivity and enhancing reliability for the 'Evaluation of Livestock Manure Treatment System and its Technology'.

An Experimental Study on Establishing Criteria of Gripping Work in Construction Site (건설 현장 악력 작업안전 기준 설정에 관한 실험적 연구)

  • 손기상;이인홍;최만진;안병준
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.81-95
    • /
    • 1995
  • Now, safety assurance in construction sites should be accomplished by its own organization rather than control of the code or government. It is believed that the safety assurance can be considerably improved by a lecture or an education using the existing theories or literatures up to now, but it is thought that fundamental safety assurance we not able to be accomplished without developing safety devices '||'&'||' equipment or taking fundamental measures, based on the result analyzed from workers behaviors. There are various behaviors of the workers showed in construction site, but only tests for hammerusing works such as form, re-bar, stone workers directly related to the grip strength are mainly performed, investigated and measured here for the study. The above works are similar to power grip, 7th picture on seven items which are categorized for hand grip types(Ammermin 1956 ; Jones ; Kobrick 1958). Measurements of grip strength are commonly taken in anthropometric surveys. They are easy to administer but unfortunately it is rather dubious whether they yield any data that are of interest to the engineer. Very fewer controls of tools are grasped and squeesed studies showed very little overall correlation between grip strength and other measures of bodily strength (Laubach, Kromer, and Thordsen 1972), but hammer-using work which is practically progressed in construction site are mainly influenced with grip strength. According to the investigation on work measurement, it is shown that 77% of form worker are using hammer to be related to grip strength. In this study, it is particularly noticed that wearing safety gloves in construction site is required for workers safety but 20% difference between grip strength with safety gloves and without ones are commonly neglected in the site(Fig. 1). Nevertheless, safety operation with consideration of the above 20% difference is not considered in the construction site. Factors of age, kinds of work, working time, with or without safety gloves are in vestigated '||'&'||' collected at the sites for this study. Test, not at each working hour but at 14 : 00 when the almost all of the workers think the most tired, resulting from the questionaires, also when it is shown on the research report has been performed and compared for main kinds of works : form '||'&'||' re-bar work. Tests were performed with both left SE rightand of the workers simultaneously in construction site using Rand Dynamometer(Model 78010, Lafayette Instrument Co., Indiana, U.S.A) by reading grip strength on the gauge while they are pulling, and then by interviewing on their ages, works, experiences and etc., directly. The above tests have been performed for the dates of 15th march-26th May '95 with consideration of site condition. And even if various factors of ambient temperature on the testing date, working condition, individual worker's habit and worker's condition of the previous ate are concerned with the study. Those are considered as constants in this study. Samples are formwork 53, rebar 62, electrician 5, plumber 4, welding 1 from D construction Co., Ltd, ; formwork 12, re-bar 5, electrician 2, from S construction Co., Ltd, , formwork 78, re-bar 18, plumber 31, electrician 13, labor 48, plumber 31, plasterer 15, concrete placer 6, water proof worker 3, maisony 5 from B construction Co., Ltd. As In the previously mentioned, main aspect to be investigated in this study will be from '||'&'||' re-bar work because grip strength will be directly applied to these two kinds of works ; form '||'&'||' re-bar work, eventhough there are total 405 samples taken. It is thought that a frequency of accident occurrence will be mainly two work postures "looking up '||'&'||' looking down" to be mainly sorted, but this factor is not clarified in this study because It will be needed a lot of work more. Tests has been done at possible large scale of horizontally work-extended sites within one hour in order to prevent or decrease errors '||'&'||' discrepancies from time lag of the test. Additionally, the statistical package computer program SPSS PC+has been used for the study.

  • PDF

Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam (PET/CT 검사 환자의 피폭선량 경감을 위한 연구)

  • Kim, Bong-Su;Pyo, Sung-Jai;Cho, Yong-Gyi;Shin, Chai-Ho;Cho, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.10-16
    • /
    • 2009
  • Purpose: As the number of patients has increased since the installation of a PET/CT, we are now examining about 2500-3000 annually. We have realized that if we properly adjust a pitch under the same condition of a CT during a PET/CT exam, radiation quantity that reaches the patient can change. In order to reduce the exposure dose of a patient, the research examines a method of reducing the exposure dose of a patient by controlling the pitch during a PET/CT exam, viewing whether the adjustment of the pitch influences CT image and PET SUV. Methods: The equipment used is a Biograph Positron Emission Tomography (PET) Scanner (CT type: TRCT-240-130 (WCT-240-130)) of Siemens company. For the evaluation of exposure dose of a patient, we measured radiation quantities using a PTW-DIADOS 11003/1383, which is a CT radiation measurement instrument used by Siemens. We measured and analyzed the space resolutions of CT images caused by the change of pitches using an AAPM Standard Phantom in order to see how the adjustment of pitches influenced the CT images. In addition, in order to obtain SUVs caused by each change of pitches using a PET source made with a solid radioactive cylinder phantom, we confirmed whether the SUVs changed in the PET/CT images by calculating the SUVs of the fusion images caused by the change of pitches after obtaining CT and PET images and finishing the test. Results: 2slice CT scanner showed that radiation quantities largely dropped when pitches ranged from 0.7 to 1.3 and that the reduction of radiation quantities were smaller when pitches ranged from 1.5 to 1.9. That is, we found that the bigger pitch values are the smaller the radiation quantities of a patient are. Moreover, we realized that there is no change of SUVs caused by the increase of pitches and that pitch values do not influence PET SUVs and the quality of CT images. It is judged that using 1.5 as a pitch value contributes to the reduction of exposure dose of a patient as long as there is no problem in the quality of an image. Conclusions: When seeing the result of the research, hospital using a PET/CT should make an effort to reduce the exposure dose of a patient seeking pitch values appropriate for their hospital within the range in which there is no image distortion and PET SUVs are not influenced from pitches. We think that the research can apply to all multi-detectors having a CT scanner and that such a research will be needed for other equipments in the future.

  • PDF

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.