• 제목/요약/키워드: instantaneous period

검색결과 91건 처리시간 0.025초

$CO_2$ 아크 용접에 있어서 다중회귀분석에 의한 아크 끊어짐을 고려한 아크 안정성 예측 모델 개발 (Development of Estimation Model Are Stability Considering Arc Extinction with Multiple Regression Analysis in $CO_2$ Arc Welding)

  • 강문진;이세헌;우재진
    • 대한기계학회논문집A
    • /
    • 제24권8호
    • /
    • pp.1885-1898
    • /
    • 2000
  • Welding quality is closely related to the arc state. So, it is very important to estimate the arc state in real time. In the short circuit transfer region of CO2 are welding, the spatter , as it is well known, is mainly generated on an instance of short circuit or on an instance that the are is ignited after short circuit, or on the cases of an instantaneous short circuit. If the short circuit period or the arc time is irregular, the spatter is generated more than it is regular. Thus there is a close relationship of the amount of the spatter generation with the arc stability. In this paper, to develop the index for estimating the arc stability in short circuit transfer range Of CO2 arc welding, the welding current and are voltage waveforms were measured and the spatter generated was captured and measured. The correlation analysis of the measured amount of the spatter with the factors (the components and the standard deviations of the components) was performed, and the factors that have a considerable influence on the spatter generation among all factors were selected. And some cases of models consisted of the factors were presented, and a mathematical index model which can make an estimation the amount of the spatter from these models with multiple regression analysis. Also, it was compared how much the amount of the spatter generated under the selected welding conditions do these index models fit, and the index model to estimate the arc stability which represent the spatter generation most appropriately was developed

고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수 (Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter)

  • 김광태
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.35-43
    • /
    • 2005
  • 종래의 컨버터-인버터 전력변환 시스템에서 do-link를 제거하여 보다 효과적인 인버터를 만들기 위하여 매트릭스 컨버터에 관하여 연구를 하고자 한다. 따라서 매트릭스 컨버터는 에너지를 저장하는 능동소자를 갖지 않는 장점이 있으나 전원이 스위치를 통하여 직접 부하에 연결되므로 전원의 리플과 노이즈가 그대로 부하에 전달되는 결점을 갖는다. 매트릭스 컨버터는 전원을 부하에 대하여 정현적으로 스위칭해야 되며, 한편 이러한 노이즈를 제거 및 보상하는 특성과 함께 역율문제도 함께 해결해야 한다. 본 연구에서는 종래의 제시된 방법에 비하여 제어어시간을 단축시킨 제어함수를 제시한다. 제시된 제어함수는 전원에 포함된 리플과 노이즈를 스위칭하는 과정에서 자동으로 보상하며 역율 1이되게 스위칭한다. 시뮬레이션 결과와 실험결과를 함께 제시한다.

우리나라 강풍의 기후학적 시공간 변화 특성 (Climatological Spatio-Temporal Variation of Strong Wind in Korea)

  • 김현욱;김백조;남형구;정종혁;심재관
    • 대기
    • /
    • 제30권1호
    • /
    • pp.47-57
    • /
    • 2020
  • In this study, the climatological spatio-temporal variation of strong wind and gust wind in Korea during the period from 1993 to 2018 was analyzed using daily maximum wind speed and daily maximum instantaneous wind speed data recorded at 61 observations. Strong wind and gust wind were defined as 14 m s-1 and 20 m s-1, which are the same as the KMA's criteria of special weather report. The frequency of strong wind and gust wind occurrence was divided into regions with the higher 25 percent (Group A) and the lower 75 percent (Group B). The annual frequency of strong wind and gust wind occurrence tended to be decreased in most parts of the Korean peninsula. In Group A with stations located at coastal region, strong wind and gust wind occurred most frequently in winter with higher frequency at 1200~1600 LST and 2300~2400 LST due to influence of East Asian winter monsoon. In addition, a marked decreasing trend throughout the four seasons was shown at Daegwallyeong, Gunsan and Wando observations. In contrast, it can be found in Group B that the monthly frequency of strong wind and wind gust occurrence was higher in August and September by effect of typhoon and hourly frequency was higher from 1200 LST to 1800 LST.

연료전지 시스템을 이용한 Line-Interactive 방식의 무정전 전원 공급 장치의 설계 (Design of the Fuel Cell Powered Line-Interactive UPS System)

  • 최우진;전희종
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.205-212
    • /
    • 2004
  • 본 논문에서는 연료전지와 컨버터 모듈을 채용한 1-[KVA] 용량의 Line-interactive방식의 무정전 전원 공급장치(UPS)가 제안된다. 제안된 시스템은 두 개의 500[W]급 양자 교환막형 연료전지에 DC/DC 컨버터가 결합된 모듈을 채용하며, 이 모듈들이 인버터의 DC-Link를 공유한다. DC-Link에는 슈퍼커패시터 모듈이 채용되어 출력의 변동이나 연료 개질기의 느린 동특성으로 인한 연료전지와 부하 사이의 순시적인 전력의 불균형을 개선시킨다. 또한 슈퍼커패시터에 저장된 에너지는 단시간 동안의 과부하를 처리할 때에도 사용될 수 있다. 제안된 시스템은 배터리를 사용하지 않으므로 환경친화적이며 청정 에너지원에 대한 요구를 만족시킨다. 1-[KVA] 시스템의 설계 예가 제시되며, 1시간의 정전동안 부하에 전력을 공급하기 위해 필요한 수소의 양과 보상용 슈퍼커패시터의 용량을 계산하는 방법이 소개된다.

초음파 센싱 방식을 이용한 이동형 호흡량 측정 진단기의 설계 및 구현 (Design and Implementation of Mobile ]Respiration Detection Diagnostic System using Ultrasound Sensing Method fficient Multicasting Environment)

  • 김동학;김영길
    • 한국정보통신학회논문지
    • /
    • 제8권2호
    • /
    • pp.509-515
    • /
    • 2004
  • 폐 기능 검사는 임상에서 환자의 진단 및 치료 판단에 널리 이용되고 있을 뿐 아니라 폐의 연구, 특히 폐의 생리학 및 폐질환의 역학 연구에 일찍부터 사용되어 왔다. 여러 가지 폐 기능 검사 중 가장 쉽고 경제적으로 시행할 수 있는 기본적인 검사법으로 폐활량 검사법(Spirometer)이 있다. 폐활량 검사기는 호흡 기체의 용적 유량의 순간적인 변화량을 측정하는 의학 기기이다. 과거에는 기계식 폐활량기가 주로 사용되었으며, 현재까지도 많이 사용되는 방법은 유체 흐름의 "양" 변화를 유체의 압력 변화로 전환시키는 차압식 방식이다. 그러나 이러한 형태는 압력 손실과 유지 보수가 힘들고, 특성 검사 주기가 짧은 단점을 가지고 있다. 본 논문에서 구현하고자 하는 것은 관성의 오차 및 압력의 오차에 영향을 거의 받지 않는, 그리고 반영구적으로 사용이 가능한 초음파 센싱 방식을 이용한 임베디드 환경의 호흡 량 측정기의 개발을 최종 목표로 하여, 호흡 기체 특성에 적합한 센서, 신호 측정 구현 회로를 포함한 유량 측정 단말부 개발과 측정신호를 이용한 호흡 측정 알고리즘과 진단 알고리즘 구현에 중점을 두었다.

Adaptive-length pendulum smart tuned mass damper using shape-memory-alloy wire for tuning period in real time

  • Pasala, Dharma Theja Reddy;Nagarajaiah, Satish
    • Smart Structures and Systems
    • /
    • 제13권2호
    • /
    • pp.203-217
    • /
    • 2014
  • Due to the shift in paradigm from passive control to adaptive control, smart tuned mass dampers (STMDs) have received considerable attention for vibration control in tall buildings and bridges. STMDs are superior to tuned mass dampers (TMDs) in reducing the response of the primary structure. Unlike TMDs, STMDs are capable of accommodating the changes in primary structure properties, due to damage or deterioration, by tuning in real time based on a local feedback. In this paper, a novel adaptive-length pendulum (ALP) damper is developed and experimentally verified. Length of the pendulum is adjusted in real time using a shape memory alloy (SMA) wire actuator. This can be achieved in two ways i) by changing the amount of current in the SMA wire actuator or ii) by changing the effective length of current carrying SMA wire. Using an instantaneous frequency tracking algorithm, the dominant frequency of the structure can be tracked from a local feedback signal, then the length of pendulum is adjusted to match the dominant frequency. Effectiveness of the proposed ALP-STMD mechanism, combined with the STFT frequency tracking control algorithm, is verified experimentally on a prototype two-storey shear frame. It has been observed through experimental studies that the ALP-STMD absorbs most of the input energy associated in the vicinity of tuned frequency of the pendulum damper. The reduction of storey displacements up to 80 % when subjected to forced excitation (harmonic and chirp-signal) and a faster decay rate during free vibration is observed in the experiments.

청수현상 추정을 위한 댐 붕괴 흐름의 유체동역학적 특성에 관한 실험적 연구 (Experimental Study on Hydrodynamic Characteristics of Dam Break Flow for Estimation of Green Water Loading)

  • 김형준;김종무;김재홍;정광효;이강남
    • 대한조선학회논문집
    • /
    • 제60권2호
    • /
    • pp.120-134
    • /
    • 2023
  • In this study, hydrodynamic characteristics of dam break flow were investigated by a series of experiments. The experiments were performed in a 2-D rectangular flume with obtaining instantaneous images of dam break flow to capture the free surface elevation, and pressure distributions on vertical wall and bottom of the flume. The initial water depth of the dam break flow was changed into 3 different heights, and the gate opening speed was changed during the experiments to study the effect of the gate speed in the dam break flow. Generation of dam break phenomena could be classified into three stages, i.e., very initial, relatively stable, and wall impact stages. The wall impact stage could be separated into 4 generation phases of wall impinge, run-up, overturning, and touchdown phases based on the deformation of the free surface. The free surface elevation were investigated with various initial water depth and compared with the analytic solutions by Ritter (1892). The pressures acting on the vertical wall and bottom were provided for the whole period of dam break flow varying the initial water depth and gate open speed. The measurement results of the dam break flow was compared with the hydrodynamic characteristics of green water phenomena, and it showed that the dam break flow could overestimate the green water loading based on the estimation suggested by Buchner (2002).

2.4 kbps 하모닉-CELP 코더를 위한 웨이블렛 피치 검출기 (Wavelet-based Pitch Detector for 2.4 kbps Harmonic-CELP Coder)

  • 방상운;이인성;권오주
    • 한국음향학회지
    • /
    • 제22권8호
    • /
    • pp.717-726
    • /
    • 2003
  • 본 논문은 2.4 kbps 하모닉-CELP 부호화기를 위한 피치 검출기의 설계 방법과 전이 시점을 검출하고 그 값을 기준으로 유/무성음 변환 구간에 대한 합성 윈도우를 달리하여 효과적인 파형 보간이 이루어지도록 하기 위한 방법을 제안하였다. 하모닉-CELP 부호화기에서 유성음 구간은 과거와 현재 프레임의 표준 파형을 보간하여 이루어지므로 전이 구간에서 피치 주기가 반으로 줄거나 두 배로 예측되어질 경우, 피치주기의 심한 변화량에 의해 파형 왜곡 및 프레임 경계에서의 불연속을 발생시킨다. 또한 하모닉 합성을 할 때 삼각 윈도우에 의한 중첩-합산 (overlap-add) 방법을 사용하기 때문에 전이 구간에서 유성음 구간의 신호가 순간적인 증가 (감소)를 할 경우 삼각 윈도우의 영향으로 합성 여기 신호가 선형 증가 (감소) 하는 단점이 있다. 우선 피치 검출기의 설계는 정확한 피치의 검출을 하되 피치 더블링에 의한 프레임 불연속성을 막기 위해 1차 혼성 검색법을 사용하였으며, ACF에 의한 2차 검색으로 피치의 정확도를 높였다. 그리고 삼각 윈도우에 의해 합성 파형이 선형 증가하던 문제는 웨이블렛에 의해 검출된 GCI를 이용하여 전이 시점을 검출한 후, 그 값을 기준으로 사다리꼴 윈도우 설정을 하여 해결하였다. 실험 결과 파형 보간 코더에서 가장 문제가 되었던 피치 더블링이 사라졌으며, 피치 검색 오차율은 ACF 검출법에 비해 5.4% 개선되었고 웨이블렛에 의한 검출법에 비해 2.66% 개선되었다. 전이 구간에서의 MOS값은 0.13 향상되었다.

기간기반 복합 이벤트 패턴 검출 (Detection of Complex Event Patterns over Interval-based Events)

  • 강만모;박상무;김상락;김강현;이동형
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.201-209
    • /
    • 2012
  • 시점기반 복합 이벤트 처리는 각 이벤트에 하나의 타임스탬프를 사용하여 즉각적인 이벤트를 처리한다. 하지만, 시점기반의 이벤트 처리로는 이벤트의 활동 기간이 중요한 역할을 하는 금융, 멀티미디어, 의학, 기상학 같은 분야에서 복합적인 시제 관계를 표현하기에는 불충분하다. 실세계의 애플리케이션 분야에서, 이벤트는 기간을 가지며, 두 종류 이상의 이벤트는 시간적으로 겹쳐질 수도 있고, 하나의 이벤트가 다른 이벤트를 포함할 수도 있다. 이런 종류의 이벤트들에 대한 관계는 시점기반 이벤트처럼 연속적이지 않을 수도 있다. 본 논문에서는 기간기반 이벤트를 사용하여 복합 이벤트의 패턴을 검출하는 방법을 설계하고 구현한다. 기간기반 이벤트는 시점기반 이벤트가 다룰 수 없는 이벤트들 사이의 겹침과 포함관계를 표현할 수 있다. 기간기반 이벤트 연산자는 시작 끝점과 종료 끝점을 사용하여 이벤트의 기간을 나타내고, 기간기반 이벤트의 시퀀스를 표현하여 복합 이벤트 패턴을 검출할 수 있다. 본 논문에서는 복합 이벤트 패턴 검출의 효율성을 높이기 위해 활성 인스턴스 스택을 사용하는 알고리즘을 제시하며, 이벤트의 시퀀스를 구성할 때 중간 결과의 개수를 줄이기 위해 윈도우 푸시다운 기법을 적용하여 수행시간과 메모리의 효율을 높인다.

운동훈련(運動訓練)에 대(對)한 심폐기능(心肺機能)의 적응(適應)에 관(關)한 연구(硏究) (Cardio-pulmonary Adaptation to Physical Training)

  • 조강하
    • The Korean Journal of Physiology
    • /
    • 제1권1호
    • /
    • pp.103-120
    • /
    • 1967
  • As pointed out by many previous investigators, the cardio-pulmonary system of well trained athletes is so adapted that they can perform a given physical exercise more efficiently as compared to non-trained persons. However, the time course of the development of these cardio-pulmonary adaptations has not been extensively studied in the past. Although the development of these training effects is undoubtedly related to the magnitude of an exercise load which is repeatedly given, it would be practical if one could maintain a good physical fitness with a minimal daily exercise. Hence, the present investigation was undertaken to study the time course of the development of cardio-pulmonary adaptations while a group of non-athletes was subjected to a daily 6 to 10 minutes running exercise for a period of 4 weeks. Six healthy male medical students (22 to 24 years old) were randomly selected as experimental subjects, and were equally divided into two groups (A and B). Both groups were subjected to the same daily running exercise (approximately 1,000 kg-m). 6 days a week for 4 weeks, but the rate of exercise was such that the group A ran on treadmill with 8.6% grade for 10 min daily at a speed of 127 m/min while the group B ran for 6 min at a speed of 200 m/min. In order to assess the effects of these physical trainings on the cardio-pulmonary system, the minute volume, the $O_2$ consumption, the $CO_2$ output and the heart rate were determined weekly while the subject was engaged in a given running exercise on treadmill (8.6% grade and 127 m/min) for a period of 5 min. In addition, the arterial blood pressure, the cardiac output, the acid-base state of arterial blood and the gas composition of arterial blood were also determined every other week in 4 subjects (2 from each group) while they were engaged in exercise on a bicycle ergometer at a rate of approximately 900 kg m/min until exhaustion. The maximal work capacity was also determined by asking the subject to engage in exercise on treadmill and ergometer until exhaustion. For the measurement of minute volume, the expired gas was collected in a Douglas bag. The $O_2$ consumption and the $CO_2$ output were subsequently computed by analysing the expired gas with a Scholander micro gas analyzer. The heart rate was calculated from the R-R interval of ECG tracings recorded by an Offner RS Dynograph. A 19 gauge Cournand needle was inserted into a brachial artery, through which arterial blood samples were taken. A Statham $P_{23}AA$ pressure transducer and a PR-7 Research Recorder were used for recording instantaneous arterial pressure. The cardiac output was measured by indicator (Cardiogreen) dilution method. The results may be summarized as follows: (1) The maximal running time on treadmill increased linearly during the 4 week training period at the end of which it increased by 2.8 to 4.6 times. In general, an increase in the maximal running time was greater when the speed was fixed at a level at which the subject was trained. The mammal exercise time on bicycle ergometer also increased linearly during the training period. (2) In carrying out a given running exercise on treadmill (8.6%grade, 127 m/min), the following changes in cardio·pulmonary functions were observed during the training period: (a) The minute volume as well as the $O_2$ consumption during steady state exercise tended to decrease progressively and showed significant reductions after 3 weeks of training. (b) The $CO_2$ production during steady state exercise showed a significant reduction within 1 week of training. (c) The heart rate during steady state exercise tended to decrease progressively and showed a significant reduction after 2 weeks of training. The reduction of heart rate following a given exercise tended to become faster by training and showed a significant change after 3 weeks. Although the resting heart rate also tended to decrease by training, no significant change was observed. (3) In rallying out a given exercise (900 kg-m/min) on a bicycle ergometer, the following change in cardio-vascular functions were observed during the training period: (3) The systolic blood pressure during steady state exercise was not affected while the diastolic blood Pressure was significantly lowered after 4 weeks of training. The resting diastolic pressure was also significantly lowered by the end of 4 weeks. (b) The cardiac output and the stroke volume during steady state exercise increased maximally within 2 weeks of training. However, the resting cardiac output was not altered while the resting stroke volume tended to increase somewhat by training. (c) The total peripheral resistance during steady state exercise was greatly lowered within 2 weeks of training. The mean circulation time during exorcise was also considerably shortened while the left heart work output during exercise increased significantly within 2 weeks. However, these functions_at rest were not altered by training. (d) Although both pH, $P_{co2}\;and\;(HCO_3-)$ of arterial plasma decreased during exercise, the magnitude of reductions became less by training. On the other hand, the $O_2$ content of arterial blood decreased during exercise before training while it tended to increase slightly after training. There was no significant alteration in these values at rest. These results indicate that cardio-pulmonary adaptations to physical training can be acquired by subjecting non-athletes to brief daily exercise routine for certain period of time. Although the time of appearance of various adaptive phenomena is not identical, it may be stated that one has to engage in daily exercise routine for at least 2 weeks for the development of significant adaptive changes.

  • PDF