• Title/Summary/Keyword: instantaneous period

Search Result 91, Processing Time 0.025 seconds

Development of Estimation Model Are Stability Considering Arc Extinction with Multiple Regression Analysis in $CO_2$ Arc Welding ($CO_2$ 아크 용접에 있어서 다중회귀분석에 의한 아크 끊어짐을 고려한 아크 안정성 예측 모델 개발)

  • Gang, Mun-Jin;Lee, Se-Heon;U, Jae-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.8 s.179
    • /
    • pp.1885-1898
    • /
    • 2000
  • Welding quality is closely related to the arc state. So, it is very important to estimate the arc state in real time. In the short circuit transfer region of CO2 are welding, the spatter , as it is well known, is mainly generated on an instance of short circuit or on an instance that the are is ignited after short circuit, or on the cases of an instantaneous short circuit. If the short circuit period or the arc time is irregular, the spatter is generated more than it is regular. Thus there is a close relationship of the amount of the spatter generation with the arc stability. In this paper, to develop the index for estimating the arc stability in short circuit transfer range Of CO2 arc welding, the welding current and are voltage waveforms were measured and the spatter generated was captured and measured. The correlation analysis of the measured amount of the spatter with the factors (the components and the standard deviations of the components) was performed, and the factors that have a considerable influence on the spatter generation among all factors were selected. And some cases of models consisted of the factors were presented, and a mathematical index model which can make an estimation the amount of the spatter from these models with multiple regression analysis. Also, it was compared how much the amount of the spatter generated under the selected welding conditions do these index models fit, and the index model to estimate the arc stability which represent the spatter generation most appropriately was developed

Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter (고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수)

  • Kim, Kwang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • Matrix converters have been studied for eliminating dc link of conventional converter-inverter system, and various undulation strategy have been proposed. Therefore, matrix converter have no energy storage component except for small ac later for the elimination of switching ripple, and can be made compact and highly reliable compare with the do link inverter system. Matrix converter, however, directly connected the input and the output terminals by bidirectional static switch. As a result if the input voltage are asymmetrical, and contain harmonics, the influence of the distortions directly appear on the output terminal. This problem is a major obstacle to the matrix converter. A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current unity input displacement factor regardless of load power factor. Moreover, compensation of the asymmetrical and/or harmonic containing input voltage is automatically realized, and calculation time of control function is reduced.

Climatological Spatio-Temporal Variation of Strong Wind in Korea (우리나라 강풍의 기후학적 시공간 변화 특성)

  • Kim, Hyun Uk;Kim, Baek-Jo;Nam, Hyoung-Gu;Jung, Jong Hyeok;Shim, Jae-Kwan
    • Atmosphere
    • /
    • v.30 no.1
    • /
    • pp.47-57
    • /
    • 2020
  • In this study, the climatological spatio-temporal variation of strong wind and gust wind in Korea during the period from 1993 to 2018 was analyzed using daily maximum wind speed and daily maximum instantaneous wind speed data recorded at 61 observations. Strong wind and gust wind were defined as 14 m s-1 and 20 m s-1, which are the same as the KMA's criteria of special weather report. The frequency of strong wind and gust wind occurrence was divided into regions with the higher 25 percent (Group A) and the lower 75 percent (Group B). The annual frequency of strong wind and gust wind occurrence tended to be decreased in most parts of the Korean peninsula. In Group A with stations located at coastal region, strong wind and gust wind occurred most frequently in winter with higher frequency at 1200~1600 LST and 2300~2400 LST due to influence of East Asian winter monsoon. In addition, a marked decreasing trend throughout the four seasons was shown at Daegwallyeong, Gunsan and Wando observations. In contrast, it can be found in Group B that the monthly frequency of strong wind and wind gust occurrence was higher in August and September by effect of typhoon and hourly frequency was higher from 1200 LST to 1800 LST.

Design of the Fuel Cell Powered Line-Interactive UPS System (연료전지 시스템을 이용한 Line-Interactive 방식의 무정전 전원 공급 장치의 설계)

  • Choi, Woo-Jin;Jeon, Hee-Jong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.205-212
    • /
    • 2004
  • In this paper the design of a 1-[KVA] fuel cell powered line-interactive UPS system employing modular (fuel cell & DC/DC converter) blocks is proposed. The proposed system employs the two fuel cell modules along with suitable DC/DC converters and these modules share the DC-Link of the DC/AC inverter. A supercapacitor module is also employed to compensate for the instantaneous power fluctuations and to overcome the slow dynamics of the fuel processor. The energy stored in the supercapacitor can also be utilized to handle the overload conditions for a short time period. Due to the absence of batteries, the system satisfies the demand for an environmentally friendly and dean source of the energy. A complete design example illustrating the amount of hydrogen storage required for 1hr power outage, and sizing of supercacpacitor for transient load demand is presented for a 1-[KVA] UPS.

Design and Implementation of Mobile ]Respiration Detection Diagnostic System using Ultrasound Sensing Method fficient Multicasting Environment (초음파 센싱 방식을 이용한 이동형 호흡량 측정 진단기의 설계 및 구현)

  • 김동학;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.509-515
    • /
    • 2004
  • Pulmonary function tests are widely used to diagnose and determine patients' therapy in clinic. And it was also applied in the research of the physiology and dynamics for lung disease. Among the pulmonary function tests, spirometry is the most easy and economic test. Spirometers are medical instruments that measure the instantaneous rate of volume flow of respired Bas. The mechanical spirometer was mostly used in the past. Up to the present, the most popular method of spirometer is the differential pressure technique with which change in the volume of flow are transferred to change in pressure. This kind of instrument suffers from several limitations, pressure drop, difficulty in maintenance and short period of calibration. Therefore, this study has begun to implement ultrasound spirometer, which is free of pressure loss and has wide range, focusing on the flow measurement technique and diagnostic algorithm.

Adaptive-length pendulum smart tuned mass damper using shape-memory-alloy wire for tuning period in real time

  • Pasala, Dharma Theja Reddy;Nagarajaiah, Satish
    • Smart Structures and Systems
    • /
    • v.13 no.2
    • /
    • pp.203-217
    • /
    • 2014
  • Due to the shift in paradigm from passive control to adaptive control, smart tuned mass dampers (STMDs) have received considerable attention for vibration control in tall buildings and bridges. STMDs are superior to tuned mass dampers (TMDs) in reducing the response of the primary structure. Unlike TMDs, STMDs are capable of accommodating the changes in primary structure properties, due to damage or deterioration, by tuning in real time based on a local feedback. In this paper, a novel adaptive-length pendulum (ALP) damper is developed and experimentally verified. Length of the pendulum is adjusted in real time using a shape memory alloy (SMA) wire actuator. This can be achieved in two ways i) by changing the amount of current in the SMA wire actuator or ii) by changing the effective length of current carrying SMA wire. Using an instantaneous frequency tracking algorithm, the dominant frequency of the structure can be tracked from a local feedback signal, then the length of pendulum is adjusted to match the dominant frequency. Effectiveness of the proposed ALP-STMD mechanism, combined with the STFT frequency tracking control algorithm, is verified experimentally on a prototype two-storey shear frame. It has been observed through experimental studies that the ALP-STMD absorbs most of the input energy associated in the vicinity of tuned frequency of the pendulum damper. The reduction of storey displacements up to 80 % when subjected to forced excitation (harmonic and chirp-signal) and a faster decay rate during free vibration is observed in the experiments.

Experimental Study on Hydrodynamic Characteristics of Dam Break Flow for Estimation of Green Water Loading (청수현상 추정을 위한 댐 붕괴 흐름의 유체동역학적 특성에 관한 실험적 연구)

  • Hyung Joon Kim;Jong Mu Kim;Jae Hong Kim;Kwang Hyo Jung;Gang Nam Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.2
    • /
    • pp.120-134
    • /
    • 2023
  • In this study, hydrodynamic characteristics of dam break flow were investigated by a series of experiments. The experiments were performed in a 2-D rectangular flume with obtaining instantaneous images of dam break flow to capture the free surface elevation, and pressure distributions on vertical wall and bottom of the flume. The initial water depth of the dam break flow was changed into 3 different heights, and the gate opening speed was changed during the experiments to study the effect of the gate speed in the dam break flow. Generation of dam break phenomena could be classified into three stages, i.e., very initial, relatively stable, and wall impact stages. The wall impact stage could be separated into 4 generation phases of wall impinge, run-up, overturning, and touchdown phases based on the deformation of the free surface. The free surface elevation were investigated with various initial water depth and compared with the analytic solutions by Ritter (1892). The pressures acting on the vertical wall and bottom were provided for the whole period of dam break flow varying the initial water depth and gate open speed. The measurement results of the dam break flow was compared with the hydrodynamic characteristics of green water phenomena, and it showed that the dam break flow could overestimate the green water loading based on the estimation suggested by Buchner (2002).

Wavelet-based Pitch Detector for 2.4 kbps Harmonic-CELP Coder (2.4 kbps 하모닉-CELP 코더를 위한 웨이블렛 피치 검출기)

  • 방상운;이인성;권오주
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.8
    • /
    • pp.717-726
    • /
    • 2003
  • This paper presents the methods that design the Wavelet-based pitch detector for 2,4 kbps Harmonic-CELP Coder, and that achieve the effective waveform interpolation by decision window shape of the transition region, Waveform interpolation coder operates by encoding one pitch-period-sized segment, a prototype segment, of speech for each frame, generate the smooth waveform interpolation between the prototype segments for voiced frame, But, harmonic synthesis of the prototype waveforms between previous frame and current frame occur not only waveform errors but also discontinuity at frame boundary on that case of pitch halving or doubling, In addtion, in transition region since waveform interpolation coder synthesizes the excitation waveform by using overlap-add with triangularity window, therefore, Harmonic-CELP fail to model the instantaneous increasing speech and synthesis waveform linearly increases, First of all, in order to detect the precise pitch period, we use the hybrid 1st pitch detector, and increse the precision by using 2nd ACF-pitch detector, Next, in order to modify excitation window, we detect the onset, offset of frame by GCI, As the result, pitch doubling is removed and pitch error rate is decreased 5.4% in comparison with ACF, and is decreased 2,66% in comparison with wavelet detector, MOS test improve 0.13 at transition region.

Detection of Complex Event Patterns over Interval-based Events (기간기반 복합 이벤트 패턴 검출)

  • Kang, Man-Mo;Park, Sang-Mu;Kim, Sank-Rak;Kim, Kang-Hyun;Lee, Dong-Hyeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.201-209
    • /
    • 2012
  • The point-based complex event processing handled an instantaneous event by using one time stamp in each event. However, the activity period of the event plays the important role in the field which is the same as the finance, multimedia, medicine, and meteorology. The point-based event is insufficient for expressing the complex temporal relationship in this field. In the application field of the real-time world, the event has the period. The events more than two kinds can be temporally overlapped. In addition, one event can include the other event. The relation about the events of kind of these can not be successive like the point-based event. This thesis designs and implements the method detecting the patterns of the complex event by using the interval-based events. The interval-based events can express the overlapping relation between events. Furthermore, it can include the others. By using the end point of beginning and end point of the termination, the operator of interval-based events shows the interval-based events. It expresses the sequence of the interval-based events and can detect the complex event patterns. This thesis proposes the algorithm using the active instance stack in order to raise efficiency of detection of the complex event patterns. When comprising the event sequence, this thesis applies the window push down technique in order to reduce the number of intermediate results. It raises the utility factor of the running time and memory.

Cardio-pulmonary Adaptation to Physical Training (운동훈련(運動訓練)에 대(對)한 심폐기능(心肺機能)의 적응(適應)에 관(關)한 연구(硏究))

  • Cho, Kang-Ha
    • The Korean Journal of Physiology
    • /
    • v.1 no.1
    • /
    • pp.103-120
    • /
    • 1967
  • As pointed out by many previous investigators, the cardio-pulmonary system of well trained athletes is so adapted that they can perform a given physical exercise more efficiently as compared to non-trained persons. However, the time course of the development of these cardio-pulmonary adaptations has not been extensively studied in the past. Although the development of these training effects is undoubtedly related to the magnitude of an exercise load which is repeatedly given, it would be practical if one could maintain a good physical fitness with a minimal daily exercise. Hence, the present investigation was undertaken to study the time course of the development of cardio-pulmonary adaptations while a group of non-athletes was subjected to a daily 6 to 10 minutes running exercise for a period of 4 weeks. Six healthy male medical students (22 to 24 years old) were randomly selected as experimental subjects, and were equally divided into two groups (A and B). Both groups were subjected to the same daily running exercise (approximately 1,000 kg-m). 6 days a week for 4 weeks, but the rate of exercise was such that the group A ran on treadmill with 8.6% grade for 10 min daily at a speed of 127 m/min while the group B ran for 6 min at a speed of 200 m/min. In order to assess the effects of these physical trainings on the cardio-pulmonary system, the minute volume, the $O_2$ consumption, the $CO_2$ output and the heart rate were determined weekly while the subject was engaged in a given running exercise on treadmill (8.6% grade and 127 m/min) for a period of 5 min. In addition, the arterial blood pressure, the cardiac output, the acid-base state of arterial blood and the gas composition of arterial blood were also determined every other week in 4 subjects (2 from each group) while they were engaged in exercise on a bicycle ergometer at a rate of approximately 900 kg m/min until exhaustion. The maximal work capacity was also determined by asking the subject to engage in exercise on treadmill and ergometer until exhaustion. For the measurement of minute volume, the expired gas was collected in a Douglas bag. The $O_2$ consumption and the $CO_2$ output were subsequently computed by analysing the expired gas with a Scholander micro gas analyzer. The heart rate was calculated from the R-R interval of ECG tracings recorded by an Offner RS Dynograph. A 19 gauge Cournand needle was inserted into a brachial artery, through which arterial blood samples were taken. A Statham $P_{23}AA$ pressure transducer and a PR-7 Research Recorder were used for recording instantaneous arterial pressure. The cardiac output was measured by indicator (Cardiogreen) dilution method. The results may be summarized as follows: (1) The maximal running time on treadmill increased linearly during the 4 week training period at the end of which it increased by 2.8 to 4.6 times. In general, an increase in the maximal running time was greater when the speed was fixed at a level at which the subject was trained. The mammal exercise time on bicycle ergometer also increased linearly during the training period. (2) In carrying out a given running exercise on treadmill (8.6%grade, 127 m/min), the following changes in cardio·pulmonary functions were observed during the training period: (a) The minute volume as well as the $O_2$ consumption during steady state exercise tended to decrease progressively and showed significant reductions after 3 weeks of training. (b) The $CO_2$ production during steady state exercise showed a significant reduction within 1 week of training. (c) The heart rate during steady state exercise tended to decrease progressively and showed a significant reduction after 2 weeks of training. The reduction of heart rate following a given exercise tended to become faster by training and showed a significant change after 3 weeks. Although the resting heart rate also tended to decrease by training, no significant change was observed. (3) In rallying out a given exercise (900 kg-m/min) on a bicycle ergometer, the following change in cardio-vascular functions were observed during the training period: (3) The systolic blood pressure during steady state exercise was not affected while the diastolic blood Pressure was significantly lowered after 4 weeks of training. The resting diastolic pressure was also significantly lowered by the end of 4 weeks. (b) The cardiac output and the stroke volume during steady state exercise increased maximally within 2 weeks of training. However, the resting cardiac output was not altered while the resting stroke volume tended to increase somewhat by training. (c) The total peripheral resistance during steady state exercise was greatly lowered within 2 weeks of training. The mean circulation time during exorcise was also considerably shortened while the left heart work output during exercise increased significantly within 2 weeks. However, these functions_at rest were not altered by training. (d) Although both pH, $P_{co2}\;and\;(HCO_3-)$ of arterial plasma decreased during exercise, the magnitude of reductions became less by training. On the other hand, the $O_2$ content of arterial blood decreased during exercise before training while it tended to increase slightly after training. There was no significant alteration in these values at rest. These results indicate that cardio-pulmonary adaptations to physical training can be acquired by subjecting non-athletes to brief daily exercise routine for certain period of time. Although the time of appearance of various adaptive phenomena is not identical, it may be stated that one has to engage in daily exercise routine for at least 2 weeks for the development of significant adaptive changes.

  • PDF