무용예술을 위한 무대조명에 관한 연구 (A Study on the Lighting for Dancing Art)

  • 이장원;이진우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.218-223
    • /
    • 2009
  • Even though the movement of human body contruct the primary factor of Dancing Art, spectators appreciate more meaningful expression of the stage that stand above limited space and time. Lighting is a distinctive expressive mechanism of obvious line, form and rhythem of human body by marking a light and shade through artificial beams into the stage. As Dancing art is different from drama, lighting of dancing stage should be distinguished from that of drama stage.

  • PDF

HID 램프용 Two-Stage 전자식 안정기의 과도 전류 제어 (Transient Current Control of Two-Stage Electronics Ballast for HID Lamps)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.1-8
    • /
    • 2014
  • The conventional Three-Stage electronic ballast is stable, but Two-Stage electronic ballast has been researching because of efficiency. Three-Stage electronic ballast is consisted of PFC circuit, buck converter, and inverter circuit, but Two-stage is consisted of PFC circuit, Buck-Inverter full bridge circuit. The Buck-Inverter full bridge inverter consists of two half bridge inverters for low frequency switching, and high frequency switching. In the case of street lamp it is far from a lamp to a ballast, the conventional pulsed high voltage ignitor can not turn on the HID lamps because of reduction of ignition voltage. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps. Therefore, in the Two-Stage electronic ballast which has the resonant tank for ignition, the transient resonant current because of low frequency changing is analyzed, the novel algorithm is proposed to resuce the transient current.

공연장의 소방시설 설치기준의 개선방안에 관한 연구 (A Study on the Fire Protection System in the Stage)

  • 장상태;이영재
    • 한국화재소방학회논문지
    • /
    • 제13권4호
    • /
    • pp.13-19
    • /
    • 1999
  • 건축물의 면적과 용도에 따른 형식적이고 획일적인 소방시설의 설치기준에 대하여 국내공연장들의 소방 시설 실태를 근거하여 건축물의 특이성에 적합한 방재시설에 대한 보완방법을 신축하고 있는 1900석 규모의 공연장을 사례로 하여 - 최 상층부 소방시설의 방수압력을 고려한 1차 수원의 100%와 예비 가압송수장치 -무대부 개방형 스프링쿨러에서의 측벽형 헤드 보완과 대구경 살수 헤드 -특수감지기의 설치규정 세분화와 첨단 감지기 도입 -무대부와 객석부의 방화구획용 방화막의 설치와 설치에 따른 설치방법 등에 대해 제시하였다.

  • PDF

산업용 원심블로어 수치해석을 위한 수치모델 평가 (Evaluation of Numerical Models for Analysing an Industrial Centrifugal Blower)

  • 이종성;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제23권6호
    • /
    • pp.688-695
    • /
    • 2012
  • The present study represents the effects of boundary condition on the performance of a centrifugal blower at the interference plane between rotational and stationary domains using three dimensional compressible Navier-Stocks equations. Two boundary conditions, frozen-rotor and stage, are compared to analyze the blower performance. Installation angle between the cutoff of a volute casing and a impeller blade is also introduced to evaluate the blower performance and to understand the internal flow inside the blower. Throughout numerical simulation, it is found that the frozen rotor interface method at the interference plane represents well the variations of flow field inside the blower compared to stage interface method. However, pressure has maximum two percent error according to the installation angles while pressure is almost constant for the stage interface method. And stage interface method can relatively well predict the blower performance. Detailed internal flows of the centrifugal blower are compared and analyzed by numerical simulation.

공연장의 전기설비중 지락보호설비에 대한 현장실태분석 연구 (A Study on the Analysis of Field Condition for Ground Fault Protection Installation among Electrical Installations in the Entertainment Area)

  • 배석명;김한상;길형준;이건호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1721-1723
    • /
    • 2002
  • This paper deals with the analysis of field condition for earth leakage current alarming system in the stage lighting, stage sound stage machinery installation. These analyses of field condition were carried out in accordance with investigating an installation of earth leakage current alarming system with respect to a main line of power source, dimmer, sound equipment, machinery mobile unit equipment and so on. As a result of analyses. The earth leakage current alarming system has been installed only a part of the main line of power source and the probability of places which were installed was less than 50(%). Therefore, it is desirable that the earth leakage current alarming system is installed at places which are suitable, for example, dimmer, each kind machinery etc. in order to prevent electrical hazard.

  • PDF

극장 형태에 따른 무대조명 디자인 기법에 관한 연구 (A Study on the Stage Lighting Design by the Type of Performance Hall)

  • 이장원;김명남
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.224-229
    • /
    • 2009
  • A Study on the Stage Lighting Design by the Type of Performance Hall The purpose of this study is to inquire into the practice of lighting design which is changed by type of stage Proscenium Stage, Thrust Stage, Arena Stage, and Flexible Stage, which have originated from ancient Greek theatre and are still used in contemporary theatre. This studt takes a good at the practical application of lighting design to different types of stage, through which it is expected to improve the understanding of lighting as a part of performing arts and to develop the quality of stage arts. The way of lighting design by type of stage can be acstracted as the following. This is expected to be of a great help to stage arts as well as different lighting designs for each type of stage. The methodology of lighting design might have limits in its application to practice in the current war Id where theatre structures and lighting equipments are fast-developing and ever-changing. However, lighting design can develop based on the basic design concepts as the researches of all fields can develop by applying their basic theories.

  • PDF

능동 클램프 ZVS 플라이백 컨버터의 역률개선에 관한 연구 (A Study on PFC of Active Clamp ZVS Flyback Converter)

  • 최태영;류동균;이우석;안정준;원충연;김수석
    • 조명전기설비학회논문지
    • /
    • 제15권6호
    • /
    • pp.49-57
    • /
    • 2001
  • 본 논문에서는 single-stage, two-stage 두가지 역률보상(PFC)기법을 기존의 능동 클램프 플라이백 컨버터에 적용하여 역률개선을 하였다. 삽입된 플라이백 컨버터의 능동클램프회로가 주스위치와 보조스위치의 영전압스위칭(ZVS)을 구현하며, 스위칭 손실을 줄임으로써 고효율을 얻을 수 있고, 높은 주파수에서의 스위칭이 가능하다. 하지만 일반적으로 사용되는 다이오드정류기, 평활용커패시터에 의한 낮은 역률의 문제점이 남아있다. 본 논문에서는 300[W급] 능동 클램프 ZVS 플라이백 컨버터를 설계하여 single-stage two-stage방식을 적용, 입력역률개선을 시뮬레이션과 실험에 의해 입증하고자 한다.

  • PDF

무용안무와 무대조명의 상호적 관계에 관한 연구 (A Study on the Reciprocal Relationship Between Dance Choreography and Stage Lighting)

  • 장소정
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.10-13
    • /
    • 2015
  • Stage lighting plays a significant role in drawing out the mood and images that are intended by the choreographer. It is related to the dancers' movements and affects them both directly and indirectly. This study is on a reciprocal relationship between dance choreography and stage lighting, covering a broad range of functional factors of lighting effects on the dance choreography. Also, the data on preferred lighting colours and their frequency of usage are gathered through surveys by lighting specialists. The data is used to identify the lighting colour in general dance choreography. It is collected to serve the purpose of providing opportunities to acknowledge the needs of various colour changes on the stage. It is hoped that a collaboration of studies related in this subject are continuously promoted and researched in producing high quality dance performances.

무대조명에서의 조도 시뮬레이션 결과와 실측값 비교 연구 (A study on the Comparison of Illuminace Simulations and Measured Values at the Stage Lighting)

  • 이장원;이진우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.230-234
    • /
    • 2009
  • 무대조명의 조도 시뮬레이션을 수행하여 얻은 결과치와 실제로 스튜디오 상에서 설치 후 조도값을 실측한 결과를 비교하여 발생하는 오차에 대하여 비교 연구 하였다.