• Title/Summary/Keyword: inspection interval

Search Result 111, Processing Time 0.031 seconds

Sparse reconstruction of guided wavefield from limited measurements using compressed sensing

  • Qiao, Baijie;Mao, Zhu;Sun, Hao;Chen, Songmao;Chen, Xuefeng
    • Smart Structures and Systems
    • /
    • v.25 no.3
    • /
    • pp.369-384
    • /
    • 2020
  • A wavefield sparse reconstruction technique based on compressed sensing is developed in this work to dramatically reduce the number of measurements. Firstly, a severely underdetermined representation of guided wavefield at a snapshot is established in the spatial domain. Secondly, an optimal compressed sensing model of guided wavefield sparse reconstruction is established based on l1-norm penalty, where a suite of discrete cosine functions is selected as the dictionary to promote the sparsity. The regular, random and jittered undersampling schemes are compared and selected as the undersampling matrix of compressed sensing. Thirdly, a gradient projection method is employed to solve the compressed sensing model of wavefield sparse reconstruction from highly incomplete measurements. Finally, experiments with different excitation frequencies are conducted on an aluminum plate to verify the effectiveness of the proposed sparse reconstruction method, where a scanning laser Doppler vibrometer as the true benchmark is used to measure the original wavefield in a given inspection region. Experiments demonstrate that the missing wavefield data can be accurately reconstructed from less than 12% of the original measurements; The reconstruction accuracy of the jittered undersampling scheme is slightly higher than that of the random undersampling scheme in high probability, but the regular undersampling scheme fails to reconstruct the wavefield image; A quantified mapping relationship between the sparsity ratio and the recovery error over a special interval is established with respect to statistical modeling and analysis.

Implementation of Drug Delivery Constitution for Inpatient based on the Position Tracking System

  • Kim, Jeong-lae;Yoon, Su-yeon;Gil, Sang-hee;Park, Bo-geun;Jeong, Hyun-woo
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.402-408
    • /
    • 2021
  • We are designed the delivery constitution technique that is to be measure the safe RFID statusof thewireless delivery system level (WDSL) on the delivery system tracking system. The delivery system level condition by the delivery system tracking system is organized with the RFID system. As to inspection a wireless network of the wireless network, we are found of the delivery value with wireless network by the upper take form. The concept of delivery system level is organized the reference of wireless level for delivery signal by the delivery RFID tracking system. Further, symbolizing a safe deliveryof the WDSL of the medium-minimum interval of the RFID tracking system, and the delivery wireless network RFID that was the delivery value of the far delivery of the DSTS-FA-φMED-MIN with 5.80±1.20 units, that was the delivery value of the convenient delivery of the DSTS-CO-φMED-MIN with 4.06±(-0.04) units, that was the delivery value of the flank delivery of the DSTS-φMED-MIN with 0.91±0.07 units, that was the delivery value of the vicinage delivery of the DSTS-VI-φMED-MIN with 0.18±(-0.03) units. The RFID will be to look into at the safe of the RFID tracking systemwith wireless network bythe delivery system level on the WDSL that is supply the wireless tracking system by the delivery system level system. We will be possible make to curb of a tracking system that to put the wireless signal and to use of the delivery data of RFID level by the delivery system.

Bending 30-gauge needles using a needle guide: fatigue life evaluation

  • Jared Joseph Tuttle;Andrew Doran Davidson;Gregory Kent Tuttle
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.5
    • /
    • pp.281-285
    • /
    • 2023
  • Background: Dentists bend needles prior to certain injections; however, there are concerns regarding needle fracture, lumen occlusion, and sharps handling. A previous study found that a 30-gauge needle fractures after four to nine 90° bends. This fatigue life study evaluated how many 90° bends a 30-gauge dental needle will sustain before fracture when bent using a needle guide. Methods: Two operators at Element Materials Technology, an independent testing, inspection, and certification company tested 48 30-gauge needles. After applying the needle guide, the operators bent the needle to a 90° angle and expressed the anesthetic from the tip. The needle was then bent back to a 0° angle, and the functionality was tested again. This process was repeated until the anesthetic failed to pass through the end of the needle due to fracture or obstruction. Each operator tested 24 needles (12 needles from each lot), and the number of sustained bends before the needle fracture was recorded. Results: The average number of sustained bends before needle failure was 40.33 (95% confidence interval = 37.41-43.26), with a minimum of 20, median of 40, and a maximum of 54. In each trial, the lumen remained patent until the needle fractured. The difference between the operators was statistically significant (P < 0.001). No significant differences in performance between needle lots were observed (P = 0.504). Conclusion: Our results suggest that using a needle guide increases the number of sustained bends before needle fracture (P < 0.000001) than those reported in previous studies. Future studies should further evaluate the use of needle guides with other needle types across a variety of operators. Furthermore, additional opportunities lie in exploring workplace safety considerations and clinical applications of anesthetic delivery using a bent needle.

The Usefulness of Rapid Triple Test for Cardiac Marker in Forensic Paragnosis of Sudden Cardiac Death (심장표지물질 간이검사의 급성심장사 법의학적 사후진단 유용성에 관한 연구)

  • Lim, Chae-Won;Kim, Jin-Gak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.2
    • /
    • pp.108-113
    • /
    • 2017
  • A sudden cardiac death (SCD) is defined as an unnatural sudden death caused by heart disease. To determine the cause of death, observation of the microscopic change in cardiac muscle tissue is suggested, rather than visual postmortem examination. However, this suggestion is time consuming to be applied in the field, is cost-ineffective, and is inconvenient. Therefore, the purpose of this study is to understand whether temporary inspection used to examine the cardiac marker (Myoglobin, CK-MB, cTn I) in postmortem blood via rapid cardiac triple test kit (which is used by clinics to diagnose patients with acute myocardial infarction) can effectively be utilized for the paragnosis of sudden, unnatural cardiac death. The results of postmortem examination and temporary investigation found that 23 groups (76.7%), among the 30 experimental groups, were assumed to be non-traumatic sudden cardiac deaths, which indicated a positive response (according to comparison with forensic autopsy); 4 groups, among the 10 control groups, were assumed to be cerebrovascular disease, which indicated a negative response; 1 group was assumed to be alcoholic and drug poisoning, indicating a positive response; and 1 group was assumed to be oxygen deficiency due to suffocation, indicating a positive response. Hence, it was found that the level of sensitivity and specificity of cardiac marker's temporary inspection showed significant result, 76.7% and 80% respectively. Given this, temporary inspection can be effectively used for the paragnosis of sudden cardiac death when the medical history, situation of the site, and postmortem interval are considered together. With the result of precedent research on time of first revelation and extinction in blood, and difference in concentration over time progress according to the characteristic of cardiac marker's (myoglobin, CK-MB, cTn I) individual material, further research on concentration of cardiac marker per each post time needs to be conducted in order to estimate time science death (which is required to identify the cause of death and investigation).

Changes of Components in Salt-Fermented Anchovy, Engraulis Japonicus Sauce during Fermentation (숙성기간에 따른 멸치액젓의 성분변화)

  • CHO Young Je;IM Yeong Sun;PARK Hee Yeol;CHOI Young Joon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.1
    • /
    • pp.9-15
    • /
    • 2000
  • To investigate changes of components in salt-fermented anchovy, Engraulis japonims sauce during fermentation, various chemical properties were examined at $1.5{\~}3$ months interval during 18 months fermentation. Moisture content and pH were decreased slightly, but the contents of VBN and crude protein, total and amino nitrogen, hydrolytic degree and absorbance at 453 nm were increased gradually during fermentation. On the other hand, ash content and salinity showed almost no change. Hk and uric acid were the most abundant in ATP related compounds, ranging from $80.1{\%}\;to\;92.7{\%}$ in salt-fermented anchovy sauce during the fermentation, After 18 months of fermentation the sauce was rich in free amino acids, such as glutamic acid, leucine, alanine, lysine, isoleucine, valine in that order.

  • PDF

White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions

  • Jeon, Jin-Hun;Lee, Kyung-Tak;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.452-456
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS. Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (${\alpha}$=.05). RESULTS. The discrepancy between the impressions for the canine, premolar, and molar teeth were $6.3{\mu}m$ (95% confidence interval [CI], 5.4-7.2), $6.4{\mu}m$ (95% CI, 5.3-7.6), and $8.9{\mu}m$ (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: $26.7{\mu}m$ (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, $16.3{\mu}m$ (95% CI, 15.3- 17.3), and $14.0{\mu}m$ (95% CI, 12.3-15.7), respectively. CONCLUSION. The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between $6.3{\mu}m$ and $8.9{\mu}m$, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions.

PM10 β-ray attenuation samplers (β-ray absorption method) equivalence evaluation and comparatively observed study (PM10 연속자동측정기(β-ray) 등가성평가 및 비교관측 연구)

  • WonSeok Jung;Hee-Jung Ko;Wonick Seo;Jiyoung Jeong;Sang Min Oh;Kyung-On Boo
    • Particle and aerosol research
    • /
    • v.19 no.1
    • /
    • pp.13-20
    • /
    • 2023
  • The Asian dust observation network operates β-ray attenuation samplers to measure PM10 concentrations. In addition, equivalence evaluation and accuracy inspection(Precision Tests) are conducted every year for the reliability of data. β-ray attenuation samplers(16 units) were comparatively observed from May to June 2020 and from July to December 2021. During the observation period, the average daily temperature was the lowest at 6.4℃ in December and the highest at 27.3℃ in August. The average daily humidity ranged from 60% to 100%, but the average daily humidity was over 75% from July to September. The minimum value of the PM10 Gravimetric method was 5.0 ㎍/m3, the maximum value was 53.4 ㎍/m3, and the average value was 17.8 ㎍/m3. The equivalence evaluation results of the PM10 Gravimetric method and β-ray attenuation samplers satisfied the criteria (slope: 1±0.1, intercept: 0±0.5). A relative error analysis between the PM10 Gravimetric method and β-ray attenuation samplers equipment showed that the relative error increased when the concentration was low and the temperature and humidity were high. In addition, in the β-ray attenuation samplers 5-minute interval observation data in May 2020, a relatively large Standard devication was shown as an average maximum ±23.4 ㎍/m3 and a minimum ±15.2 ㎍/m3. At standard deviations of 10% and 90%, equipment with high variability (deviation) was measured at 6 ㎍/m3and 61 ㎍/m3, and equipment with low variability was measured at 12 ㎍/m3 and 47 ㎍/m3. It was confirmed that concentration differences occurred due to differences in variability for each equipment.

Measurement of the Mucosal Surface Distance in the Early Gastric Cancer Using CT Gastrography (조기 위암에서 CT Gastrography를 이용한 위점막 표면 거리 측정)

  • Choi, Hyang-Hee;Yu, Wan-Sik;Ryeom, Hun-Kyu;Lee, Jae-Hyuk;Choi, Jae-Jeong;Kim, Hee-Su;Cleary, Kevin;Mun, Seong-Ki;Chung, Ho-Young
    • Journal of Gastric Cancer
    • /
    • v.6 no.3
    • /
    • pp.161-166
    • /
    • 2006
  • Purpose: Recently, the incidence of early gastric cancer (EGC) patients is rapidly increased in Korea. However, they're often not perceptible by surgical palpation or inspection. The aim of this study is 1) to develope a software that can locate the tumor and measure the mucosal distance from an anatomic landmark to the tumor using CT gastrography and 2) to compare the distance measured by the developed software with the distance measured by the pathologic findings. Materials and Methods: Between January 2004 and September 2005, sixty patients (male=45, female=15, mean 57.8 years old) estimated for EGC with preoperative CT scans and undergone gastrectomies in Kyungpook National University Hospital were enrolled in this study. Preoperative CT scans were performed after insufflations of room air via 5 Fr NG tube. The scans included the following parameters: (slice thickness/reconstruction interval: 0.625 mm, kVp: 120, mAs: 200). 3D volume rendering and measurement of the surface distance from the pylorus to the EGC were performed using the developed software. Results: The average difference between the lesion to pylorus distances measured from pathologic specimens and CT gastrography was $5.3{\pm}2.9\;mm(range,\;0{\sim}23\;mm)$. The lesion to pylorus distance measured from CT gastrography was well correlated with that measured from the pathologic specimens (r=0.9843, P<0.001). Conclusion: These results suggest that the surface distance from an anatomic landmark to the EGC can be measured accurately by CT gastrography. This technique could be used for preoperative localization of early gastric carcinomas to determine the optimal extent of surgical resection.

  • PDF

Prophylactic and therapeutic studies on intestinal giant-cystic disease of the Israel carp caused by yhelohunellus kitauei I. Course of formation and vanishment of the cyst (향어의 장포자충(Thelohanellus kitauei)증의 예방 및 치료에 관한 기초적 연구 I . 종유의 소장 과정)

  • 이재구;김종오
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.3
    • /
    • pp.183-194
    • /
    • 1990
  • In an attempt to develop prophylactic and therapeutic measures of the intestinal giant-cystic disease caused by Thelohanellus kitauei in the Israel carp, Cyprinus carpio nodus, pathological observations were conducted upon the carps which were hatched in May 1988 and raised in a net cage fish farm at the Soyang lake, managed by Horim Fisheries for the period of 21 months with 1~2 months interval. After a gross inspection of the carps, necropsy was carried out periodically in order to clarify the pathological changes in various internal organs and muscular tissues. Also. the prevalence of the disease was checked during the period from 1988 to 1990. Gross inspections revealed that the infected carps showed some degree of fading in body and gill color, back-emaciation symptoms, reddish anus accompanying erosion and relaxation and pot-belly, as well as discharge of yellowish white mucoid material from the anus. However, most carps died eventually of intestinal obstruction. Other significant necropsy fadings included cyst formation of various size in the intestinal mucosa, ascites, anemic condition through internal organs and muscular tissues, hyperemia and dilation of intestines with decreased tension, thinness and fragility, and full contents of semi-fluid or yellowish white mucoid material in the intestinal canals. Based on the morphological characteristics of the spores found in the cysts, parasitic location in the intestines, macro- and microscopic findings of the lesions, the parasites were identised as Thelohanellus kitauei Egusa os Nakajima, 1981. Although monthly changes of water temperature were distinct, the extrusion rates of the polar filaments of the spores stayed constant throughout the year with an exception of a lower rate in July, The lesions initiated from mucosa and submucosa in early July became large swellings and then complete mature (orms following the peracute course. From late August the upper cysts were gradually opened and most of the spores were dispersed from anus into the surrounding water through December but only a few lasted until next April. The cysts were completely recovered until next September. Comparing the incidence and prevalence of the disease by year tremendous infection and death rates were checked in the first prevalent year, 1988, but the rates were significantly decreased in the second year, and showed an almost normal status in the third year, 1990. As the above summarized results showed, the disease entity might come to an end in three years after the first prevalent year, however, the spores must be strictly prevented because they could be infective in the water for one year.

  • PDF

Residual Characteristics and Monitoring of Cyenopyrafen and Cyflumetofen in Strawberries for Export (수출딸기 중 Cyenopyrafen과 Cyflumetofen의 잔류소실 특성평가 및 잔류농약 모니터링)

  • Kim, Yeong-Jin;Kim, Jong-Hwan;Kwon, Young-Sang;Song, Jong-Wook;Seo, Jong-Su
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.4
    • /
    • pp.279-287
    • /
    • 2017
  • BACKGROUND: Many farmers who cultivate the strawberries for export have used agricultural chemicals which MRL (Maximum Residue Limits) of main export target countries or simultaneous multi-residue analysis in Korea have not been established. Among them, the cyenopyrafen and cyflumetofen were selected and applied to this study to determine the PHI (pre-harvest interval) which is appropriate to the PLS (Positive List System) criterion (0.01 mg/kg) and to investigate the residual amounts in the samples. In addition, Fifty pesticides were monitored to check up whether it is suitable or not for main export target countries. METHODS AND RESULTS: Cyenopyrafen and cyflumetofen were spayed out to the strawberries. Samples for residual analyses were taken for maximum 60 days. After sampling, they were extracted by the QuEChERS method and analyzed using the LC-MS/MS. Cyenopyrafen and cyflumetofen were detected in a range of 0.0106~2.6517 mg/kg and of 0.0005~1.4480 mg/kg, respectively. From this results, they were found to be suitable for PLS concentration after 30 or 45 days after spray. In addition, they were detected in most samples that were selected at random. Their concentrations were higher than the PLS criterion in the maximum twenty samples. Twelve of pesticides unsuitable for main export target countries have been detected in the monitoring of simultaneous multi-residue analysis. The result indicates they are unsuitable for export since they excesses over PLS criterion. CONCLUSION: The monitoring result showed it is necessary to establish the pesticide standards of safe use suitable for the PLS criterion. In addition, it is considered continues management and inspection are needed to solve problems caused by unsuitable pesticides in export strawberries.