• Title/Summary/Keyword: inspection and diagnosis

Search Result 470, Processing Time 0.026 seconds

A Study on the Self-Diagnosis Criteria of Electrical Installations (자가용 전기설비의 자가진단 기준에 대한 연구)

  • Kim, Jong-Min;Lee, Hyeon-Woo;Kim, Hong-Ki;Yoo, Sang-Bong;Jang, Kyung-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.863-869
    • /
    • 2017
  • This paper is to enable electrical safety manager to have more objective evaluation on the safety by indicating quantitative values such as life-time and status quotient of daily visual inspection on private electrical equipments. Self-diagnosis table is recommended to apply such a evaluation efficiently according to the characteristics of each electrical equipments, and the managers's determination of the precise inspection, replacement etc. will be also possible through the standard selected by various domestic and foreign data with expert's advise for numerical evaluation. This circumstance will be able to establish the foundation to secure the soundness of electrical equipments.

Damage Assessment of RC Bridge Using Neural-Fuzzy System (퍼지신경망을 이용한 철근콘크리트 교량의 손상도 평가)

  • Seong, Young-Joon;Kim, Ki- Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.4
    • /
    • pp.129-137
    • /
    • 1999
  • Assessment of structural damage is a complex subject imbued with uncertainty and vagueness. This complexity arises from the use of subjective opinion and imprecise numerical data. Recently several active researches have been performed using new methods such as neural network approach or on-line damage detection. In this paper, Damage assessment (diagnosis) of the concrete bridges is studied by a new approach utilizing a neural fuzzy system that combined a neural network and a fuzzy logic. By applying this system to actual in-service bridges, it has been verified that the neural fuzzy method is effective for the bridge diagnosis.

  • PDF

Understanding Facility Management on Tunnel through Text Mining of Precision Safety Diagnosis Data (터널시설물 점검진단 데이터의 텍스트마이닝 분석을 통한 유형별·지역별 중점 유지관리요소의 이해)

  • Seo, Jeong-eun;Oh, Jintak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.3
    • /
    • pp.85-92
    • /
    • 2021
  • The purpose of this paper is to understand the key factors for efficient maintenance of rapidly aging facilities. Therefore, the safety inspection/diagnosis reports accumulated in the unstructured data were collected and preprocessed. Then, the analysis was performed using a text mining analysis method. The derived vulnerabilities of tunnel facilities can be used as elements of inspections that take into account the characteristics of individual facilities during regular inspections and daily inspections in the short term. In addition, if detailed specification information and other inspection results(safety, durability, and ease of use) are used for analysis, it provides a stepping stone for supporting preemptive maintenance decision-making in the long term.

Development of Risk-Based Inspection(RBI) Technology for LNG Plant Based on API RP581 Code (API RP 581 Code를 기반으로한 LNG 플랜트의 Risk-Based Inspection(RBI) 기술 개발)

  • Choi, Song-Chun;Choi, Jae-Boong;Hawang, In-Ju
    • Corrosion Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.179-183
    • /
    • 2012
  • As one of promising solutions to overcome high oil price and energy crisis, the construction market of high value-added LNG plants is spotlighted world widely. The purpose of this study is to introduce LNG-RBI system to develop risk assessment technology with RAM(Reliability, Availability, Maintainability) modules against overseas monopolization. After analyzing relevant specific features and their technical levels, risk assessment program, non-destructive reliability evaluation strategy and safety criteria unification class are derived as core technologies. These IT-based convergence technologies can be used for enhancement of LNG plant efficiency, in which the modular parts are related to a system with artificial optimized algorithms as well as diverse databases of facility inspection and diagnosis fields.

Drone Infrared Thermography Method for Leakage Inspection of Reservoir Embankment (드론 열화상활용 저수지 제체 누수탐사)

  • Lee, Joon Gu;Ryu, Yong Chul;Kim, Young Hwa;Choi, Won;Kim, Han Joong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.6
    • /
    • pp.21-31
    • /
    • 2018
  • The result of examination of diagnostic method, which is composed of a combination of a thermal camera and a drone that visually shows the temperature of the object by detecting the infrared rays, for detecting the leakage of earth dam was driven in this research. The drone infrared thermography method was suggested to precise safety diagnosis through direct comparing the two method results of electrical resistivity survey and thermal image survey. The important advantage of the thermal leakage detection method was the simplicity of the application, the quickness of the results, and the effectiveness of the work in combination with the existing diagnosis method.

Investigating Factors Contributing to Inadequate Facility Safety Inspections and Diagnosis Services: A Machine Learning Approach (머신러닝 기반 시설물 안전 점검·진단용역 부실 판정 요인에 대한 연구)

  • Junyong Park;Chie Hoon Song
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.4_2
    • /
    • pp.897-908
    • /
    • 2024
  • Evaluating the adequacy of facility safety inspection and diagnosis services performed by private enterprises is a time-consuming and administratively complex process. This study aims to analyze the determinants that could influence the rating of these safety inspection and diagnosis services using data analytics approach. Through a comparative analysis of several machine learning algorithms suitable for multi-class classification, we selected the model with the best performance (Random Forest) and identified the main determinants using the permutation importance technique. Among the variables examined, "contract value," "days of service performed" and "adherence to fair market value" were found to be strongly correlated with the rating assessments. Furthermore, we discovered that the skills and expertise of service performing personnel significantly impacted the rating. The results of this study can contribute to the enhancement of the current post-evaluation administrative processes and offer valuable insights into rating assessments by incorporating previously unexplored variables pertaining to both service providers and the services itself.

Face Regions Segmentation and Five Sensory Organs & Myeongdang Extraction Method for Baby Ocular Inspection (소아 망진을 위한 얼굴 영역 분할과 오관 및 명당 추출 방법)

  • Kim Bong-Hyun;Lee Se-Hwan;Kim Seung-Youn;Lee Bok-Gi;Koo Kyung-Ok;Cho Dong-Uk
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.4
    • /
    • pp.69-80
    • /
    • 2006
  • Interest about baby health increased into promise of all life health on society. Prevention disease or treatment about baby health is important, but it is important that first of grasping baby state through correct diagnosis. In this paper, diagnosis method for baby ocular inspection of Oriental medicine applying image processing technology is presented. For this, extracting baby frontal face image based on skin color, five sensory organs extraction and extraction of myeongdang based on position information is proposed. Finally, usefulness of method Proposed by an experiment world prove.

  • PDF

An Experimental Study on the Engineering Properties of Deteriorated Concrete using Recycled Fine Aggregate by Fire Damage (재생잔골재를 활용한 화재피해를 입은 콘크리트의 공학적 특성에 관한 실험적 연구)

  • Kwon, Yung-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.190-196
    • /
    • 2006
  • In the existed study, a fire outbreak in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the Properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. Therefore, This study is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with making variable concrete test specimen, exposing high temperature environment, observing the explosive spalling and examining engineering property.

Inspection of the Diagnosis Report for Life Assessment of Engine Generator (내연발전기 건전성 판정을 위한 종합 진단결과 고찰)

  • Lee, Young-Jun;Ju, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.96-99
    • /
    • 2010
  • This paper presents evaluating procedure for engine generator operated over 13 years which are usually installed at the island and therefore, isolated to the main distribution line. To decide continual operation of the generator, their diagnosis results should guarantee safety running. So the determination of criteria for continual usage or replacement is essential for economical and reliable maintenance. We present all the courses of evaluating the condition which includes the processes from acquiring basic data to comprehensive determination of generators. All the test was applied to serial number 3 generator in Jodo Engine Power Plant.

A Study on the Improvement of Evaluation Method of Diagnosis-System for Exterior-Wall Deterioration by Infrared Thermography (적외선 탐사기를 이용한 외벽열화 진단시스템의 평가기법 향상에 관한 연구)

  • Kim, Moo-Han;Kwon, Young-Jin;Kang, Suk-Puo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.2
    • /
    • pp.185-190
    • /
    • 1999
  • It is difficult to estimate for deterioration of exterior wall by infrared thermography, because of amount of infrared-ray radiation effected by environmental factors such as temperature properties of materials, the outside air and the amount of solar radiation. Therefore we measured the distribution of temperature by times in the same reinforced-concrete structure in order to reduce problems, occasioned by environmental factors, then we analyzed physical influence factors of the infrared thermography. It is the aim of this study to suggest basic data with regard to method of estimation-system for deterioration of exterior wall in reinforced-concrete structures.

  • PDF