• 제목/요약/키워드: input ground motion

검색결과 198건 처리시간 0.024초

도시개발 영역 고정밀 공간지반모델의 지진 시 액상화 재해 및 지반 취약성 평가 활용 (Application into Assessment of Liquefaction Hazard and Geotechnical Vulnerability During Earthquake with High-Precision Spatial-Ground Model for a City Development Area)

  • 김한샘;선창국;하익수
    • 한국지진공학회논문집
    • /
    • 제27권5호
    • /
    • pp.221-230
    • /
    • 2023
  • This study proposes a methodology for assessing seismic liquefaction hazard by implementing high-resolution three-dimensional (3D) ground models with high-density/high-precision site investigation data acquired in an area of interest, which would be linked to geotechnical numerical analysis tools. It is possible to estimate the vulnerability of earthquake-induced geotechnical phenomena (ground motion amplification, liquefaction, landslide, etc.) and their triggering complex disasters across an area for urban development with several stages of high-density datasets. In this study, the spatial-ground models for city development were built with a 3D high-precision grid of 5 m × 5 m × 1 m by applying geostatistic methods. Finally, after comparing each prediction error, the geotechnical model from the Gaussian sequential simulation is selected to assess earthquake-induced geotechnical hazards. In particular, with seven independent input earthquake motions, liquefaction analysis with finite element analyses and hazard mappings with LPI and LSN are performed reliably based on the spatial geotechnical models in the study area. Furthermore, various phenomena and parameters, including settlement in the city planning area, are assessed in terms of geotechnical vulnerability also based on the high-resolution spatial-ground modeling. This case study on the high-precision 3D ground model-based zonations in the area of interest verifies the usefulness in assessing spatially earthquake-induced hazards and geotechnical vulnerability and their decision-making support.

Investigation of seismic response of long-span bridges under spatially varying ground motions

  • Aziz Hosseinnezhad;Amin Gholizad
    • Earthquakes and Structures
    • /
    • 제26권5호
    • /
    • pp.401-416
    • /
    • 2024
  • Long-span structures, such as bridges, can experience different seismic excitations at the supports due to spatially variability of ground motion. Regarding current bridge designing codes, it is just EC 2008 that suggested some regulations to consider it and in the other codes almost ignored while based on some previous studies it is found that the effect of mentioned issue could not be neglected. The current study aimed to perform a comprehensive study about the effect of spatially varying ground motions on the dynamic response of a reinforced concrete bridge under asynchronous input motions considering soil-structure interactions. The correlated ground motions were generated by an introduced method that contains all spatially varying components, and imposed on the supports of the finite element model under different load scenarios. Then the obtained results from uniform and non-uniform excitations were compared to each other. In addition, the effect of soil-structure interactions involved and the corresponding results compared to the previous results. Also, to better understand the seismic response of the bridge, the responses caused by pseudo-static components decompose from the total response. Finally, an incremental dynamic analysis was performed to survey the non-linear behavior of the bridge under assumed load scenarios. The outcomes revealed that the local site condition plays an important role and strongly amplifies the responses. Furthermore, it was found that a combination of wave-passage and strong incoherency severely affected the responses of the structure. Moreover, it has been found that the pseudo-static component's contribution increase with increasing incoherent parameters. In addition, regarding the soil condition was considered for the studied bridge, it was found that a combination of spatially varying ground motions and soil-structure interactions effects could make a very destructive scenarios like, pounding and unseating.

수정된 등가선형해석기법의 정확성 평가 (Evaluation of Accuracy of Modified Equivalent Linear Method)

  • 정창균;곽동엽;박두희;김광균
    • 한국지반환경공학회 논문집
    • /
    • 제11권6호
    • /
    • pp.5-20
    • /
    • 2010
  • 1차원 등가선형 지반응답해석은 지반에 의한 지진동의 증폭현상을 모사하는데 널리 사용되고 있다. 등가선형해석은 적은 수의 입력변수를 필요로하므로 사용하기 편리하며 해석 소요시간이 짧다는 장점을 가지고 있는 반면, 시간에 따라서 변화하는 지반의 비선형 거동을 모사할 수 없으며 일정한 전단탄성계수와 감쇠비를 해석 내내 적용하는 선형해석이라는 단점을 가지고 있다. 이와 같은 등가선형해석의 단점을 보완하기 위하여 진동 주파수와 변형률과의 관계를 모사하는 다양한 형태의 수정된 등가선형해석기법들이 개발되었다. 수정된 기법들은 전단변형률 푸리에 스펙트럼을 사용한다는 점에서는 동일하지만, 이로부터 변형률의 주파수 의존도를 정의하는 과정에서는 차이를 보이고 있다. 본 연구에서는 두 가지 수정된 등가선형해석기법들의 정확성을 평가하기 위하여 국내에서 조사된 두 개의 토층에서 일련의 비선형, 등가선형, 수정된 등가선형 지반응답해석을 수행하였다. 해석 결과, 수정된 등가선형해석기법들은 고주파수 요소를 과대 예측할 수 있으며, 특히 고주파수 요소가 풍부한 인공지진파를 입력 지진파로 사용하였을 경우 비현실적인 응답이 계산될 수 있는 것으로 나타났다.

지하층-지반 운동학적 상호작용을 고려한 기초저면의 설계지반운동 산정 (Extracting Foundation Input Motion Considering Soil-Subterranean Level Kinematic Interaction)

  • ;윤지남;김주형;박두희
    • 한국지반환경공학회 논문집
    • /
    • 제19권11호
    • /
    • pp.31-37
    • /
    • 2018
  • 대부분의 초고층 건물은 지상 구조물과 주차와 상가 용도 등으로 사용되는 복수층의 지하 구조물로 구성된다. 지하층은 초고층 건물의 지진응답에 큰 영향을 줄 수 있지만 내진설계에서 이의 영향이 명확하게 규명되지 않았다. 국외에서 가장 널리 사용되는 고층 구조물 내진설계 지침서에서는 지하층은 모델링하되 주변 지반은 모사하지 않으며 지하층-지반 운동학적 상호작용을 고려하여 계산된 기초 저면의 운동을 적용할 것을 권장하고 있다. 본 연구에서는 지하 1층과 5층 구조물에 대한 동적 해석을 수행하여 지하층 저면에서의 운동을 계산하였으며 자유장 운동과 비교하였다. 수치해석 결과를 내진설계 지침서에 제시된 상호작용을 고려하는 두가지 방법과 비교한 결과, 지하 1층의 경우 이 중 한가지 방법이 해석결과와 잘 맞지만 지하 5층의 경우 지침서에 제시된 방법은 큰 차이가 발생하는 것으로 나타났다.

말뚝 기초 고유진동수의 가속도 크기 의존성을 고려한 상사법칙 개발 (Development of the similitude law considering the intensity-dependent variation of natural frequency of pile foundation system)

  • 최정인;유민택;김성렬;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.905-912
    • /
    • 2009
  • 1-g shaking table test is conducted to evaluate the dynamic behavior of a soil-structure system under seismic loading condition. A consistent similitude law between the model and prototype is needed to predict the behavior of the prototype structure, quantitatively. The natural frequency of geomaterial decreases with the increase of shaking intensity because of the non-linear property of the geomaterial. This phenomenon affects the applicability of similitude laws in 1-g shaking table tests. In this study, a simple method is suggested to determine the frequency of the input motions in 1-g tests in order to enhance the applicability of similitude laws. Modified input frequency is calculated using the frequency ratio with consideration of the variation of the natural frequency according to the intensity of input ground acceleration. To verify the applicability of the suggested method, a series of 1-g shaking table tests were performed for three different sizes of model piles having an overburden mass on their heads by varying the acceleration and the frequency of input motion. The acceleration amplification ratio on the overburden mass, the lateral displacement at the pile head and the maximum bending moment along the pile depth were measured. The projected behaviors of the virtual prototype based on the measured values of the model tests, where the input frequencies were calculated by the new method, showed good consistency, verifying the applicability of the suggested method.

  • PDF

침대에 부착된 용량성 전극 배열을 이용한 수면 중의 심전도 측정 (ECG Measurement Method during Sleep with Array of Capacitive Electrodes Attached to Bed)

  • 임용규;김고근;박광석;정도언
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.521-524
    • /
    • 2005
  • In order to measure ECG in daily life, a new ECG measurement method on bed was developed. The provided method does not require any direct conductive contact between the instrument and bare skin, so that it does not cause the uncomfortable feel of touch and the possible skin trouble which are typical shortcomings of the conventional conductive contact ECG measurement. The provided method utilized an array of high-input-impedance active electrodes fixed on the mattress and an indirect-skin-contact ground made of a large conductive textile sheet and laid on lower area of the mattress. A thin cotton bedcover covered the mattress, the electrodes, and the conductive textile and subjects lay on the mattress over the bedcover. ECG was obtained successfully. However its signal quality is lower and the motion artifact is larger than direct-contact measurement. Careful measurement setup was needed to reduce the motion artifact originated from variation in static electricity. From the ECG obtained by the provided method, R-peak could be discriminated easily and the information about the position and the posture of the subject could be obtained.

  • PDF

점탄성감쇠기를 설치한 구조물의 비용효율성 평가 (Cost-Effectiveness Evaluation of the Structure with Viscoelastic Dampers)

  • 고현무;함대기;조상열
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.387-393
    • /
    • 2001
  • Installing vibration control devices in the structure rises as a solution instead of increasing structural strength considering construction cost. Especially, viscoelastic dampers show excellent vibration control performance at low cost and are easy to install in existing structures compared with other control devices. Therefore, cost-effectiveness of structure with viscoelastic dampers needs to be evaluated. Previous cost-effectiveness evaluation method for the seismically isolated structure(Koh et al., 1999;2000)is applied on the building structure with viscoelastic dampers, which combines optimal design and cost-effectiveness evaluation for seismically isolated structures based on minimum life-cycle cost concept. Input ground motion is modeled in the form of spectral density function to take into account acceleration and site coefficients. Damping of the viscoelastic damper is considered by modal strain energy method. Stiffness of shear building and shear area of viscoelastic damper are adopted as design variables for optimization. For the estimation of failure probability, transfer function of the structure with viscoelastic damper for spectral analysis is derived from the equation of motion. Results reveal that cost-effectiveness of the structure with viscoelastic dampers is relatively high in how seismic region and stiff soil condition.

  • PDF

전통 초가삼간 가옥의 내진성능 평가 실험(I) : 암반지반 조건 (A Test on the Aseismic Capacity of a Traditional Three-bay-straw-roof House(I) : Rock Site Condition)

  • 서정문;최인길;전영선;이종림;신재철
    • 한국지진공학회논문집
    • /
    • 제1권4호
    • /
    • pp.11-20
    • /
    • 1997
  • 우리나라 전통 초가삼간의 1/4 축소모델을 제작하여 암반지반 조건에 대한 내진성능실험을 수행하였다. Nahanni 지진파를 사용하여 최대 가속도 0.1g~0.6g 범위에서 거동을 분석하였다. 탄성한계에서 초가삼간의 고유진동수는 장방향의 경우 약 1.66Hz, 단방향의 경우 215Hz이다. 탄성한계에서의 감쇠비는 약 7%이다. 수평방향의 가속도응답은 입력에 비해 감소하며 입력가속도 수준이 증가할수록 감소율이 증가한다. 이는 사개맞춤으로 만들어진 목조 프레임의 비선형.비탄성 특성 때문이다. 전통 초가삼간 가옥은 고진동수가 지배적인 암반지반에서 매우 큰 내진성능을 나타내었다.

  • PDF

테프론형 기초지진격리장치의 성능평가 (Evaluation of Performance of the Teflon-Type Seismic Foundation Isolation System)

  • 손수원;김응수;나건하;김진만
    • 한국지진공학회논문집
    • /
    • 제21권3호
    • /
    • pp.125-135
    • /
    • 2017
  • Various seismic isolation methods are being applied to bridges and buildings to improve their seismic performance. Most seismic isolation systems are the structural seismic isolation systems. In this study, the seismic performance of geotechnical seismic isolation system capable of isolating the lower foundation of the bridge structure from ground was evaluated. The geotechnical seismic isolation system was built with teflon, and the model structure was made by adopting the similitude law. The response acceleration for sinusoidal waves of various amplitudes and frequencies and seismic waves were analyzed by performing 1-G shaking table experiments. Fixed foundation, Sliding foundation, and Rocking foundation were evaluated. The results of this study indicated that the Teflon-type seismic foundation isolation system is effective in reducing the acceleration transmitted to the superstructure subject to large input ground motion. Response spectrum of the Rocking and Sliding foundation structures moves to the long period, while that of Fixed foundation moves to short period.

Exploring the effects of tuned mass dampers on the seismic performance of structures with nonlinear base isolation systems

  • Hessabi, Reza Mirza;Mercan, Oya;Ozturk, Baki
    • Earthquakes and Structures
    • /
    • 제12권3호
    • /
    • pp.285-296
    • /
    • 2017
  • Base isolation is a quite practical control strategy for enhancing the response of structural systems induced by strong ground motions. Due to the dynamic effects of base isolation systems, reduction in the interstory drifts of the superstructure is often achieved at the expense of high base displacement level, which may lead to instability of the structure or non-practical designs for the base isolators. To reduce the base displacement, several hybrid structural control strategies have been studied over the past decades. This study investigates a particular strategy that employs Tuned Mass Dampers (TMDs) for improving the performance of base-isolated structures and unlike previous studies, specifically focuses on the effectiveness of this hybrid control strategy in structures that are equipped with nonlinear base isolation systems. To consider the nonlinearities of base isolation systems, a Bouc-Wen model is selected and nonlinear dynamic OpenSees models are used to perform several time-history simulations in time and frequency domains. Through these numerical simulations, the effects of several parameters such as the fundamental period of the structure, dynamic properties of the TMD and isolation systems and properties of the input ground motion on the behaviour of TMD-structure-base isolation systems are examined. The results of this study provide a better insight into the performance of linear shear-story structures with nonlinear base isolators and show that there are many scenarios in which TMDs can still improve the performance of these systems.