• Title/Summary/Keyword: inlet pressure

Search Result 1,649, Processing Time 0.036 seconds

Investigation on the Flow Field Upstream of a Centrifugal Pump Impeller

  • Zhang, Yao;Luo, Xianwu;Yi, Yunchi;Zhuang, Baotang;Xu, Hongyuan
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.209-216
    • /
    • 2011
  • The flow upstream of a centrifugal pump impeller has been investigated by both experimental test and numerical simulation. For experimental study, the flow field at four sections in the pump suction is measured by using PIV method. For calculation, the three dimensional turbulent flow for the full flow passage of the pump is simulated based on RANS equations combined with RNG k-$\varepsilon$ turbulence model. From those results, it is noted that at both design lo ad and quarter load condition, the pre-swirl flow whose direction is the same as the impeller rotation exists at all four sections in suction pipe of the pump, and at each section, the pre-swirl velocity becomes obviously larger at higher rotational speed. It is also indicated that at quarter load condition, the low pressure region at suction surface of the vane is large because of the unfavorable flow upstream of the pump impeller.

Effect of Flow Uniformity Device on the Catalytic Combustor for 5 kW High Temperature Fuel Cell System (5 kW급 고온형 연료전지 촉매 연소기 유동 균일화 장치가 연소 특성에 미치는 영향)

  • Lee, Sang-Min;Woo, Hyun-Tak;Ahn, Kook-Young
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.878-883
    • /
    • 2011
  • Effect of flow uniformity on the reaction characteristics of a catalytic combustor for high temperature fuel cell system has been experimentally investigated in the present study. One of the most important factor in designing catalytic combustion is to avoid hot spot in catalysts. In this regard, it is very important to secure flow uniformity of combustor inlet. A couple of perforated plates were applied at the front of catalyst region as flow uniformity device with minimal pressure drop. Results show that the velocity and temperature profile became more uniform when applying the flow uniformity device. CO and $CH_4$ emissions at the combustor exit were decreased and the average exit temperature was slightly increased with the flow uniformity device.

Performance Characteristics of Combined Heat and Power Generation with Series Circuit Using Organic Rankine Cycle (유기랭킨사이클을 이용한 직렬 열병합 사이클의 성능 특성)

  • Kim, Kyoung-Hoon;Jung, Young-Guan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.5
    • /
    • pp.699-705
    • /
    • 2011
  • A combined heat and power cogeneration system driven by low-temperature sources is investigated by the first and second laws of thermodynamics. The system consists of Organic Rankine Cycle (ORC) and an additional process heater as a series circuit. Seven working fluids of R152a, propane, isobutane, butane, R11, R123, isopentane and n-pentane are considered in this work. Maximum mass flow rate of a working fluid relative to that of the source fluid is considered to extract maximum power from the source. Results indicate that the second-law efficiency can be significantly increased due to the combined heat and power generation. Furthermore, higher source temperature and lower turbine inlet pressure lead to lower second-law efficiency of ORC system but higher that of combined system. Results also show that the optimum working fluid varies with the source temperature.

Combustion Instability of Gas Turbine with Segmented Dynamic Thermo-Acoustic Model under Load Follow-Up (이산형 열-음향 모델을 이용한 부하 변동시 가스터빈 연소 불안정 특성)

  • JEONG, JIWOONG;HAN, JAEYOUNG;JEONG, JINHEE;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.538-548
    • /
    • 2018
  • The thermo-acoustic instability in the combustion process of a gas turbine is caused by the interaction of the heat release mechanism and the pressure perturbation. These acoustic vibrations cause fatigue failure of the combustor and decrease the combustion efficiency. This study is to develop a segmented dynamic thermo-acoustic model to understand combustion instability of gas turbine. Therefore, this study required a dynamic analysis rather than static analysis, and developed a segmented model that can analyze the performance of the system over time using the Matlab/Simulink. The developed model can confirm the thermo-acoustic combustion instability and exhaust gas concentration in the combustion chamber according to the equivalent ratio change, and confirm the thermo-acoustic combustion instability for the inlet temperature and the load changes. As a result, segmented dynamic thermo-acoustic model has been developed to analyze combustion instability under the operating condition.

Performance Analysis of the Vertical Multi-stage Centrifugal Pump using Commercial CFD Code (상용 CFD코드를 이용한 입형 다단 원심펌프 성능해석)

  • MO Jang-Oh;KANG Shin-Jeong;SONG Geun-Taek,;NAM Cheong-Do;LEE Young-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.150-155
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pump including impeller with 6 blades and guide vane with 11 blades and is performed by changing flow rate from 10 to $26m^3/h$ at the constant 3500rpm. The purpose of this 3-D numerical simulation is not only to confirm how much the effect of three kinds of blade inlet breadth (11mm, 11.5mm, 12mm) of impeller has influence on the performance of vertical multi-stage pump but also to make clear the cause about performance difference at the exit side of impeller and guide vane. The vertical multi-stage pump consisit of the impeller, guide, vane and cylinder. The grid of numerical analysis used to the vertical multi-stage pump is 18,000, 45,000, and 100000 cells in case of the impeller, guide vane, cylinder and total grid is 730,000 cells. The characteristics such as total pressure coefficient, total head, shaft horse power, power efficiency at the exit side of impeller and guide vane, discharge coefficient are represented according to flow rage changing.

  • PDF

Exergy Analysis of Regenerative Steam-Injection Gas Turbine Systems (증기분사 재생 가스터빈 시스템의 엑서지 해석)

  • Kim, Kyoung-Hoon;Jung, Young-Guan;Han, Chul-Ho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.4
    • /
    • pp.45-54
    • /
    • 2009
  • An exergy analysis is carried out for the regenerative steam-injection gas turbine systems which has a potential of enhanced thermal efficiency and specific power. Using the analysis model in the view of the second law of thermodynamics, the effects of pressure ratio, steam injection ratio, ambient temperature and turbine inlet temperature are investigated on the performance of the system such as exergetic efficiency, heat recovery ratio of heat exchangers, exergy destruction, loss ratios, and on the optimal conditions for maximum exergy efficiency. The results of computation show that the regenerative steam-injection gas turbine system can make a notable enhancement of exergy efficiency and reduce irreversibilities of the system.

A Study on Effects of Large Tip Clearance in a Turbine Cascade (터빈캐스케이드에서 큰 팁간극에 의한 효과에 관한 연구)

  • Lee, Hyo-Seong;Song, Seung-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.33-36
    • /
    • 2010
  • Lots of studies about turbine loss have been done especially about tip leakage loss. But these studies deals with small tip clearances which is less than 5 percent chord. Now, like turbopumps, small turbines have larger tip clearance and it is hardly found related papers in open literature. On this study, with varying tip clearance 1% to 20% chord, loss is measured under inlet velocity at 30m/s and Reynolds number based on chord at 210000. It is found that maximum loss coefficient is 0.113 at 10% clearance, and when tip clearance is larger than 10%, loss is not linearly increased anymore.

  • PDF

Microchannels for the Flow Control of Two Fluids with Different Volumes (부피가 다른 두 유체의 효과적인 유동제어를 위한 미세채널)

  • La, Moon-Woo;Ho, Jae-Yun;Kim, Dong-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.89-95
    • /
    • 2012
  • In this paper, microchannels for the flow control of two fluids with different volumes have been designed, fabricated, and verified. The dimensions of the inlets were determined based on the Stokes equation in order to realize that the flow of the two fluids meet at the same time, and to maintain a certain configuration when the flows passed through each inlet channel. The designed microchannels were confirmed using computational fluid dynamics simulation for the incompressible, Newtonian, and transient flows. In addition, a microfluidic system containing the designed microchannels was fabricated by soft lithography, and the pressure-driven flows of the two fluids were characterized by microfluidic experiments.

An experimental study on heat transfer characteristics in a vertical micro-fin tube during evaporation process of carbon dioxide flowing upward (이산화탄소의 마이크로 핀관 내 상향유동 증발열전달 특성에 관한 연구)

  • Kim, Yong-Jin;Cho, Jin-Min;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.247-251
    • /
    • 2007
  • Because of the ozone layer depletion and global warming, new alternative refrigerants are being developed. In this study, evaporation heat transfer characteristics of carbon dioxide flowing upward in a vertical micro-fin tube have been investigated by experiment. Before a test section, a pre-heater is installed to adjust the inlet quality of the refrigerant to a desired value. The micro-fin tube with outer diameter of 5 mm and length of 1.44 m was selected as the test section. The test was conducted at mass fluxes of 318 to $530\;kg/m^2s$, saturation temperature of -5 to $5^{\circ}C$, and heat fluxes of 15 to $30\;kW/m^2$. As the vapor quality increases, the heat transfer coefficients of carbon dioxide are increased, and the heat transfer coefficients increase when the heat fluxes and saturation temperatures increase, and there was not much of influence of mass flux on the heat transfer coefficients.

  • PDF

Study on the Counterflow Regenerative Evaporative Cooler with Finned Channels (대향류 핀삽입형 재생증발식 냉방기 연구)

  • Choi, Bong-Su;Hong, Hi-Ki;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.447-454
    • /
    • 2008
  • The regenerative evaporative cooler(REC) is to cool a stream of air using evaporative cooling effect without an increase in the humidity ratio. In the regenerative evaporative cooler, the air can be cooled down to a temperature lower than its inlet wet-bulb temperature. Besides the cooling performance, for practical application of the regenerative evaporative cooler, the compactness of the system is also a very important factor to be considered. In this respect, three different configurations, i.e., the flat plate type, the corrugated plate type, and the finned channel type are investigated and compared for the most compact configuration. The optimal structure of each configuration is obtained individually to minimize the volume for a given effectiveness within a limit of the pressure drop. Comparing the three optimal structures, the finned channel type is found to give the most compact structure among the considered configurations. The volume of the regenerative cooler can be reduced to 1/8 by adopting the finned channel type as compared to that of the flat plate type.