• 제목/요약/키워드: inlet flow conditions

검색결과 601건 처리시간 0.023초

전력구트라프내간접수냉방식에서의 송전용량 변화에 관한 연구 (A Study on the Variation of the Transmission Capacity by External water Cooled System with Trough in Tunnel)

  • 박만흥;조규식;김재근;서정윤
    • 대한전기학회논문지
    • /
    • 제41권5호
    • /
    • pp.445-458
    • /
    • 1992
  • As one of the forced cooling method of the underground power transmission system, external water cooled system with trough in tunnel was investigated. This study is performed on thermal analysis for a standard condition to determine the cable transmission current of the underground power transmission system about the cooling facility. A parametric study was performed for the inlet water temperatures, flow rates, the inlet air velocities, flow rates and the cooling spans. This study shows that the cable transmission current varies within the allowable limitation in compliance with the variation of inlet water temperatures and flow rates. It exhibits little variations for the most intervals in compliance with the variation of inlet air temperatures and flows. But, the cable transmission current fast reduces for a specified interval and consequently affects the underground transmission system. As a result, when the actual forced cooling system is designed, the design conditions of inlet air have to be considered as the most important parameters in determination of the cable transmission current.

The Effects of Injector Nozzle Geometry and Operating Pressure Conditions on the Transient Fuel Spray Behavior

  • Koo, Ja-Ye
    • Journal of Mechanical Science and Technology
    • /
    • 제17권4호
    • /
    • pp.617-625
    • /
    • 2003
  • Effects of Injector nozzle geometry and operating pressure conditions such as opening pressure, ambient pressure. and injection pressure on the transient fuel spray behavior have been examined by experiments. In order to clarify the effect of internal flow inside nozzle on the external spray, flow details Inside model nozzle and real nozzle were alto investigated both experimentally and numerically. for the effect of injection pressures, droplet sizes and velocities were obtained at maximum line pressure of 21 MPa and 105 MPa. Droplet sizes produced from the round inlet nozzle were larger than those from the sharp inlet nozzle and the spray angle of the round inlet nozzle was narrower than that from the sharp inlet nozzle. With the increase of opening pressure, spray tip penetration and spray angle were increased at both lower ambient pressure and higher ambient pressure. The velocity and size profiles maintained similarity despite of the substantial change in injection pressure, however, the increased injection pressure produced a higher percentage of droplet that are likely to breakup.

난류 예혼합 연소기에서의 흡입 유동 섭동에 대한 화염의 동적 거동 (Flame Dynamic Response to Inlet Flow Perturbation in a Turbulent Premixed Combustor)

  • 김대식
    • 한국연소학회지
    • /
    • 제14권4호
    • /
    • pp.48-53
    • /
    • 2009
  • This paper describes the forced flame response in a turbulent premixed gas turbine combustor. The fuel was premixed with the air upstream of a choked inlet to avoid equivalence ratio fluctuations. To impose the inlet flow velocity, a siren type modulation device was developed using an AC motor, rotating and static plates. Measurements were made of the velocity fluctuation in the nozzle using hot wire anemometry and of the heat release fluctuation in the combustor using chemiluminescence emission. The test results showed that flame length as well as geometry was strongly dependent upon modulation frequency in addition to operating conditions such as inlet velocity. Convection delay time between the velocity perturbation and heat release fluctuations was calculated using phase information of the transfer function, which agreed well with the results of flame length measurements. Also, basic characteristics of the flame nonlinear response shown in the current test conditions were introduced.

  • PDF

다중 블록 격자를 이용한 원뿔 직관 모양의 벌류트 유동의 수치해석 (NUMERICAL SIMULATION ON A VOLUTE OF STRAIGHT CONICAL DUCT TYPE BY MULTI-BLOCK GRID)

  • 배황;강현구;윤주식;박기철;장근식
    • 한국전산유체공학회지
    • /
    • 제11권1호
    • /
    • pp.1-7
    • /
    • 2006
  • Numerical investigation of a centrifugal compressor volute having a modified straight conical duct hill been made. Three-dimensional Reynolds-Averaged Navier-Stokes equations with $k-{\varepsilon}$ turbulence equation are solved To avoid coordinate singularity at the central axis of the duct, multi-block H-type grid is generated on the circular cross-sections of the volute and stretched toward the solid wall boundary. We obtained numerical results with three different mass flow rates at the volute inlet, namely, with the inlet conditions that give small, medium and large mass flow rates at the outlet of the conical duct. Agreement with the experimental results is observed.

상반류(물/공기) 유동한계에 관한 연구 (Counter-Current Flow Limit of a Vertical Two Phase (Water/Air) Flow)

  • 오율권;조상진;김상녕;이종원
    • 대한기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.308-322
    • /
    • 1991
  • 본 연구에서는 CCFL에 영향을 미치는 관의 크기, 길이, 주입구 형상 등 변화 에 대한 현상해석과 이의 영향을 고려한 관계식의 개발에 있다. 그러므로 본 실험에 서의 물의 주입량을 관에 수막(film)이 형성시킬 수 있는 유량으로 고정시킨 상태에서 공기의 유량을 증가시켜, CCFL이 발생하였을때 공기와 물의 유량을 측정하였다. 그 리고 관의 길이, 크기 그리고 물의 주입구 구조(예각, 둔간, 톱니, 다공)의 변화에 따 른 CCFL의 영향에 관하여 실험을 수행하였다.

받음각이 있는 3차원 초음속 흡입구 주위의 유동진동 해석 (Numerical Analysis of Flow Characteristics around 3D Supersonic Inlet at Various Angle of Attack)

  • 김정민;홍우람;김종임
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.218-224
    • /
    • 2011
  • A supersonic inlet at angle of attack has anti-symmetric pressure distribution, and it can make flow instability and structural problem. In this study, numerical analysis of three-dimensional inviscid flow was conducted under various throttle ratio and angle of attack conditions. Throttle ratio was defined as the ratio of the exit area to the smallest cross section area at inlet, and the ratio is controlled from 0 to 2.42. At various angle of attack, the characteristics of steady and unsteady flow around supersonic inlet is observed under different throttling ratios. From these results, pressure recovery curves and pressure history curves were plotted by post processing. Using pressure history data, FFT analysis is also carried out. Through these processes, it shows the tendency of pressure distribution anti-symmetricity and changing dominant frequency as increasing angle of attack.

  • PDF

열해현상 방지를 위한 버스 엔진룸 구조개선 (Reengineering of Bus Engine Room Structure for Preventing Thermal Damages)

  • 맹주성;윤준용;손한규
    • 한국자동차공학회논문집
    • /
    • 제8권3호
    • /
    • pp.46-55
    • /
    • 2000
  • Four types of different flow inlet models were tested to improve the flow uniformity at the inlet of the radiator and to prevent thermal damages of auxiliary units from the hot air in the bus engine room. Measurements and numerical calculations were performed and their results were in a good agreement with each other. Simultaneously temperature measurements were carried out under the conditions of actual bus driving. As designing the new flow inlet at the partition board which seperates the engine space and radiator space, flow circulation can be achieved and fresh air comes into the engine room from the bottom. It was proved that new inlet makes the one air temperature cooling down in the engine room, the other uniformity improvement.

  • PDF

A SENSITIVITY STUDY OF THE DISTORTED INLET FLOW IN AXIAL TURBOMACHINERY WITH NOVEL INTEGRAL SCHEME

  • Ng Eddie Yin-Kwee;Liu Ningyu;Lim Hong Ngiap;Tan Daniel
    • 한국전산유체공학회지
    • /
    • 제10권1호
    • /
    • pp.51-55
    • /
    • 2005
  • For proper installation, operation and performance of axial flow jet engines in aircrafts, the impacts and effects of inlet flow distortion in axial compressors have to be understood. Inlet distortion conditions may cause component-mismatch and instability problems known as rotating stall, and severe oscillations of mass flow rate called surge or a combination of both. Typical effects of this phenomenon include stresses and wear on the compressor blading, destruction of entire jet engines due to the failure of airfoil and mechanical failure or interruption of the combustion process. Therefore, it is important to study inlet flow distortion and its propagation effects to minimize and hence to prevent the occurrence of such calamity. The current novel integral method with parametric analysis signifies its validity to this field of research and offers much potential for further improvements. The present effort further indicates that this simple method may be flourishing in the problems of strongly distorted flow and propagating stall in axial compressor. It is therefore believe that using a more realistic and flexible velocity and pressure profiles could develop this approach further.

초음속 터빈 캐스케이드 입구 경계조건의 특성에 관한 연구 (A Study on The Characteristics of The Inlet Boundary Condition of a Supersonic Turbine Cascade)

  • 신봉근;성영식;정수인;김귀순;이은석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.99-103
    • /
    • 2003
  • 캐스케이드 내 유동 해석은 터보 펌프의 설계 제작에 필수적인 요소이다. 그러나 기존의 무한 입구 경계 조건에서는 입구 유동의 초기 설정 경계치와 계산 후 입구 유동 경계치의 차이가 발생하여 원하는 입구 경계 조건에서의 유동 해석을 하지 못한다. 이에 본 연구에서는 Fine Turbo를 이용하여 입구 경계 조건으로 무한 경계 조건을 적용하였을 때 발생하는 문제점을 분석하였다. 그리고 무한 입구 경계 조건 대신 캐스케이드 앞에 수축·확산 노즐이나 직선 노즐을 위치시켜 전산 해석을 실시하여 그 특성을 비교, 검토하였다.

  • PDF

Numerical Study on Coolant Flow Distribution at the Core Inlet for an Integral Pressurized Water Reactor

  • Sun, Lin;Peng, Minjun;Xia, Genglei;Lv, Xing;Li, Ren
    • Nuclear Engineering and Technology
    • /
    • 제49권1호
    • /
    • pp.71-81
    • /
    • 2017
  • When an integral pressurized water reactor is operated under low power conditions, once-through steam generator group operation strategy is applied. However, group operation strategy will cause nonuniform coolant flow distribution at the core inlet and lower plenum. To help coolant flow mix more uniformly, a flow mixing chamber (FMC) has been designed. In this paper, computational fluid dynamics methods have been used to investigate the coolant distribution by the effect of FMC. Velocity and temperature characteristics under different low power conditions and optimized FMC configuration have been analyzed. The results illustrate that the FMC can help improve the nonuniform coolant temperature distribution at the core inlet effectively; at the same time, the FMC will induce more resistance in the downcomer and lower plenum.