• 제목/요약/키워드: inlet Vortex

검색결과 181건 처리시간 0.019초

Vortex Tube의 부분유입율과 저온 입.출구비가 에너지분리 특성에 미치는 영향 (Effects of the partial admission rate and cold flow inlet-outlet ratio on energy separation of Vortex Tube)

  • 김정수;추홍록;상희선
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.51-59
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air conditioner for special purpose. The phenomena of energy separation through the vortex tube were investigated to see the effects of cold flow inlet-outlet ratios and partial admission rates on the energy separation experimentally. The experiment was carried out with various cold flow inlet-outlet ratios from 0.28 to 10.56 and partial admission rates from 0.176 to 0.956 by varying input pressure and cold air flow ratio. To find best use in a given cold flow inlet-outlet ratio and partial admission rate, the maximum temperature difference of cold air was presented. The experimental results were indicated that there are an optimum range of cold flow inlet-outlet ratio for each partial admission rate and available partial admission rate.

  • PDF

입.출구의 압력조건에 따른 보텍스 튜브의 에너지분리 특성에 관한 실험적 고찰 (Experimental Investigation for the Characteristics of Energy Separation of a Vortex Tube at Various Inlet and outlet Pressure Conditions)

  • 유갑종;김정수;최인수
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1149-1155
    • /
    • 2001
  • The experimental investigation on energy separation in a vortex tube has been carried out to sow the effect of inlet and outlet pressures with various working fluids(air,$O_2,\;and\; CO_2$). Those outlet pressure means cold outlet and hot outlet pressure which were set equally. The results showed that the total enthalpy variation became a maximum when the mass flow rate at the cold outlet was a half of the total mass flow rate in the vortex tube (y=0.5). The total enthalpy variation was quite affected by the pressure difference between the inlet and outlet of vortex tube when the ratio of the inlet pressure to the cold outlet pressure remained constant. Although specific enthalpy differences between the inlet and the outlet (both cold and hot outlet) did not noticeably vary with the pressure difference, the specific enthalpy difference between the inlet and cold outlet was dominantly affected by physical properties of working gases.

  • PDF

Inlet Cone Vortex에 의한 500 MW급 발전용 보일러 홴-덕트 시스템의 과대진동 (Excessive Vibration of the Fan-duct Systems in 500 MW Power Plant Boilers Due to Inlet Cone Vortex)

  • 김철홍;주영호;변형현
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.116-121
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure Pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

화력 발전용 보일러 Duct/Fan 시스템의 진동현상에 대한 연구 : Inlet Vortex에 의한 과대진동 사례 (A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers: Inlet Vortex Induced Excessive Vibration)

  • 김철홍;주영호;변형현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.82-87
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

연구용 원자로 유입 공동에서 다공형 차폐물에 의한 와류 감쇄효과 예측 (Prediction of Vortex Reducing Effect by a Peforated Baffle in the Inlet Plenum of a Research Reactor)

  • 박종학;채희택;박철;김헌일
    • 한국전산유체공학회지
    • /
    • 제9권2호
    • /
    • pp.11-17
    • /
    • 2004
  • CFD analysis was performed to figure out flow behavior in the inlet plenum of new research reactor where coolant is injected to the flow tubes with the fuel assembly. The computation results showed that large-scale vortices are generated in the inlet plenum by flow stream injected from inlet pipe. These vortices are divided into small vortices and reversed their revolution. They may lead to flow-induced vibration of fuel assembly, moreover, which has been regarded as a cause of fretting wear of fuel assembly. Also there is an another important thing that average velocity of each flow-tube is uneven showing difference in maximum 18%. So it has been suggested that perforated baffle will be installed to prevent the formation of vortex in the inlet plenum. Two perforated baffles, one is flow skirt and the other is muffler type flow straightener, were proposed and their effect was evaluated using commercial CFD code, Fluent. According to CFD analysis for two perforated baffles, it was confirmed that both of them can prevent or reduce vortex formation in the inlet plenum and make average velocity of each flow tube more even.

주기적인 입구 속도 변동에 따른 원관 주위 유동 및 열전달 특성 (Flow and Heat Transfer Characteristics of a Circular Cylinder with the Periodic Inlet Velocity)

  • 하지수
    • 한국가스학회지
    • /
    • 제23권3호
    • /
    • pp.27-32
    • /
    • 2019
  • 본 연구에서는 단일 원관에서 입구의 유속이 일정한 경우와 주기적인 변동이 있는 경우에 대하여 시간에 따라 원관 주위에서 와류 분포와 온도 분포 변화를 비교 분석하였다. 또한, 양력과 항력의 시간 변화와 PSD(power spectral density)를 분석하여 유동의 주파수 특성을 규명하였다. 일정 입구 유속의 경우는 잘 알려진 칼만 와류 분포를 보여 주었으며 원관의 상하에서 교대로 와류가 발생하는 것을 관찰할 수 있었다. 주기적인 입구 유속 변동의 경우는 원관의 상하에서 동시에 와류가 발생하는 것을 관찰할 수 있었다. 두 가지 모두 시간에 따른 온도 분포 변화는 와류 분포 변화와 거의 유사하게 거동하는 것을 확인할 수 있었다. 일정 입구 유속의 경우의 와류 유동 주파수는 31.15 Hz 이며 주기적인 입구 유속의 경우는 와류 유동 주파수는 입구 유속의 주파수와 동일하게 15.57 Hz으로 나타났다. 원관 표면 평균 누셀수는 일정 입구 유속의 경우는 99.6이며 주기적인 입구 유속 변동의 경우는 110.7로 나타나서 주기적인 입구 속도 변동의 경우가 열전달이 11.1% 증가하는 것을 알 수 있었다.

볼텍스 튜브의 에너지 분리 특성에 대한 실험적 연구 (Experimental Study on Energy Separation Characteristics of Vortex Tube)

  • 이준순;한근희;박성영
    • 대한기계학회논문집B
    • /
    • 제35권5호
    • /
    • pp.517-524
    • /
    • 2011
  • 볼텍스 튜브는 고압의 가스를 이용하여 고온 가스와 저온 가스를 분리하거나 입자상 물질의 분리에 사용 할 수 있는 장치이다. 본 연구에서는 직경 10mm의 볼텍스 튜브의 기본 설계 자료를 구축하기 위하여 에너지 분리 성능 실험을 수행하였다. 설계를 위한 기초 자료를 확보하기 위하여, 공급압력, 볼텍스 발생기의 오리피스 직경 및 튜브의 길이가 에너지 분리 특성에 미치는 영향력을 실험을 통하여 분석하였다. 결과적으로 오리피스 직경과 공급압력이 볼텍스 튜브의 성능의 지배적인 성능인자임을 확인하였다. 튜브길이가 성능에 미치는 영향은 미미하였다. Dc=0.7D, L=16D의 볼텍스 튜브에서 가장 우수한 에너지 분리효과를 얻을 수 있었다.

보텍스 생성실 지름비가 에너지 분리에 미치는 영향 (The Effect of a Vortex Chamber Diameter Ratio on Energy Separation)

  • 유갑종;이병화;최인수
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.667-673
    • /
    • 2001
  • As an alternative cooling method to reduce environmental hazard, vortex tubes have been studied for energy separation into cold and hot streams. Hence, the experiments were carried out systematically to find the best ratio of vortex chamber diameter to tube diameter. Also, the work was don to investigate how inlet pressure and geometric ratios of vortex tube affected temperature differences at tow needs as ell as cooling capacity and cooling efficiency. The result showed that the maximum temperature differences at the both ends and the maximum cooling efficiency were obtained when the ratio of vortex chamber diameter was about 1.45, while the inlet pressure ws not higher than 0.7 MPa.

  • PDF

화력 발전용 보일러 덕트-홴 시스템의 진동현상에 대한 연구 : 입구측 와류에 의한 과대진동 사례 (A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers : Inlet Vortex Induced Excessive Vibration)

  • 김철홍;주영호
    • 한국소음진동공학회논문집
    • /
    • 제13권3호
    • /
    • pp.194-201
    • /
    • 2003
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in a fan-duct system of fossil fueled boilers. We measured static pressure variation (pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this Paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

균일 전단유동 내에 위치한 구 주위의 유동특성 (Characteristics of Flow past a Sphere in Uniform Shear)

  • 김동주;최형석;최해천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1607-1612
    • /
    • 2004
  • Numerical simulations are performed to investigate the characteristics of flow past a sphere in uniform shear. The Reynolds numbers considered are Re=300, 425 and 480 based on the inlet center velocity and sphere diameter. The non-dimensional shear rate K of the inlet uniform shear is varied from 0 to 0.15. At Re=300, the head of the hairpin vortex loop always locates on the high-velocity side in uniform shear, and the flow maintains the planar symmetry. At Re=425 and 480, the irregularity in the location and strength of the hairpin vortex appearing in uniform inlet flow is much reduced in uniform shear, but the flows still keep the asymmetry for most inlet shear rates. However, in the cases of K=0.075 and 0.1 at Re=425, the flows become planar symmetric and their characteristics of the evolution of the hairpin vortex loops are different from those of asymmetric flows. A hysteresis phenomenon switching from the planar symmetry to the asymmetry (or vice versa) depending on the initial condition is also observed at Re=425.

  • PDF