• Title/Summary/Keyword: injection probe

검색결과 97건 처리시간 0.029초

열가소성 복합소재를 이용하여 사출성형 한 PEMFC용 bipolar plate의 전기전도도 및 기계적 특성 연구 (A study on the electrical and mechanical properties of PEMFC bipolar plate by thermoplastic composite injection molding process)

  • 윤용훈;김동학
    • 한국산학기술학회논문지
    • /
    • 제12권4호
    • /
    • pp.1999-2004
    • /
    • 2011
  • 본 논문은 매트릭스 수지로 LCP(Liquid crystal polymer)를 사용하였으며, 기계적 특성 및 화학적 특성을 증대시키기 위해 주 첨가제로 synthetic graphite, expanded graphite와 보조 첨가제로는 carbon black을 사용하여, 함량 별로 복합소재를 제조하였다. 사출성형 전 CAE 프로그램으로 해석을 하였으며, 유동성과 섬유 배향을 예측 했다. 복합 소재는 전동식 사출기를 이용하여 ASTM 복합 시편으로 사출성형 하였으며, 시편을 four point probe 장치를 사용하여 전기전도도를 측정/비교 하였으며, 기계적 강도는 굴곡강도, 굴곡탄성률, 충격강도를 측정하였다. 첨가제가 증가할 수록 전기전도도는 증가하나 첨가제의 brittle한 특성으로 인해 기계적 강도는 감소하는 것을 확인 할 수 있었다.

Application of Light Collecting Probe with High Spatial Resolution to Spark-Ignited Spherical Spray Flames

  • Yang, Young-Joon;Akamatsu, Fumiteru;Katsuki, Masashi
    • Journal of Mechanical Science and Technology
    • /
    • 제18권11호
    • /
    • pp.2058-2065
    • /
    • 2004
  • A light collecting probe named Multi-color Integrated Cassegrain Receiving Optics (MICRO) is applied to spark-ignited spherical spray flames to obtain the flame propagation speed in freely falling droplet suspension produced by an ultrasonic atomizer. Two MICRO probes are used to monitor time-series signals of OH chemiluminescence from two different locations in the flame. By detecting the arrival time difference of the propagating flame front, the flame propagation speed is calculated with a two-point delay-time method. In addition, time-series images of OH chemiluminescence are simultaneously obtained by a high-speed digital CCD camera to ensure the validity of the two-point delay-time method by the MICRO system. Furthermore, the relationship between the spray properties measured by phase Doppler anemometer (PDA) and the flame propagation speed are discussed with three different experimental conditions by changing the fuel injection rate. It was confirmed that the two-point delay-time method with two MICRO probes is useful and convenient to obtain the flame propagation speed and that the flame propagation speed depends on the spray properties.

CAD 모델에 기초한 기상측정 (OMM (On-the-Machine Measurement) based on CAD Model)

  • 김승록;박영근;권기복;박정환;고태조;김희술;김창일
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.169-172
    • /
    • 2000
  • In this paper, an OMM (On-the-Machine Measuring) system has been developed, which can perform measuring and inspection of sculptured surfaces of die and mold, by use of a scanning-type touch probe mounted into the spindle of a NC machine. The calibration procedures of a scanning prove (SP2-1, Renishaw) and an algorithm for measuring surface points by a ball-nosed stylus have been studied. The system has been developed based on commercial CAM software (Z-Master 2000), and tested through measuring a plastic injection molding-die. Also some experimental results of the calibration and measuring for given surface positions are analyzed to verify its accuracy and reliability.

  • PDF

직분식 가솔린기관 인젝터의 연료 분무 특성 (Fuel Spray Characteristics of GDI Injector)

  • 권상일;이창식
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.194-201
    • /
    • 2000
  • This paper is intended to analyze the macroscopic behavior and transient atomization characteristics of the high-pressure gasoline injector in direct-injection gasoline engine. The global spray behavior of fuel injector was visualized by shadowgraph technique. Time-resolved droplet axial and radial velocity components and droplet diameter were measured at many probe positions in both axial and radial directions by a two-component phase Doppler particle analyzer (PDPA). In order to obtain the influence of fuel injection pressure, the macroscopic visualization and experiment of particle measurement on the fuel spray were investigated at 3,5 and 7 MPa of injection pressure under different surrounding pressure in the spray chamber. The results of this work show that the fuel injection pressure of gasoline injector in GDI engine has influence upon the mean droplet diameter, mean velocity of spray droplet, the spray tip penetration, and spray width under the elevated ambient pressure.

  • PDF

현장실측에 의한 메시(Mesh)접지저항 출정기법 연구 (A Study on the Measurement Technique of the Grounding Mesh Resistance by Field Measurements)

  • 한기붕;김삼수;정세중;이상익
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.426-429
    • /
    • 1999
  • In this paper, we have provided the measurement technique of the grounding mesh resistance by field measurements. The standard of measurement is specified in the IEEE Std 81.2-1991 and JEAC 5001-1988, which is the the fall-of-potential method by test-current injection, but this method is difficult to apply at field, where is small around a electric power substation of domestic. For the convenient measurement method, space of assistant probe and quantity of test-current injection are changed step for step. As the result, ' the proposed measurement technique of grounding mesh resistance is that the space of current and potential probes must be fixed at 150rn from a grounding mesh, the test-current injection has to keep 5A or more.

  • PDF

기체가 주입된 원통형 용기내에서 기포유동에 관한 연구 (A Study on Bubbles Flow in the Gas-injected Cylindrical Bath)

  • 서동표;박근욱;오율권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.393-396
    • /
    • 2002
  • Submerged gas-injected system can be applied to various industrial field such as metallurgical and chemical processes, So this study aims at presenting the relevant relationship between gas phase and liquid phase in a gas-injected bath. In a cylinderical bath, local gas volume fraction and bubble frequency were measured by electroconductivity probe and oscilloscope. The temperature of each phase was measured using thermocouple and data acquisition system. In vertical gas injection system, gas-liquid two phase plume was formed, being symmetry to the axial direction of injection nozzle and in a shape of con. Lacal gas-liquid flow becomes irregular around the injection nozzle due to kinetic energy of gas and the flow variables show radical change at the vicinity of gas(air) injection nozzle As most of the kinetic energy of gas was transferred to liquid in this region, liquid started to circulate. In this reason, this region was defined as 'developing flow region' The Bubble was taking a form of churn flow at the vicinity of nozzle. Sometimes smaller bubbles formed by the collapse of bubbles were observed. The gas injected into liquid bath lost its kinetic energy and then was governed by the effect of buoyancy. In this region the bubbles which lost their kinetic energy move upward with relatively uniform velocity and separate. Near the gas nozzle, gas concentration was the highest. But it started to decrease as the axial distance increased, showing a Gaussian distribution.

  • PDF

Effectiveness of a Hockey-Stick Probe to Localize a Catheter Fragment in a Dog

  • Kim, Kitae;Oh, Dayoung;Shin, Dongmin;Yoon, Junghee
    • 한국임상수의학회지
    • /
    • 제39권4호
    • /
    • pp.173-176
    • /
    • 2022
  • Intravenous catheterization is a common procedure in human and veterinary medicine. Occasionally, a catheter might break within the blood vessel, and the fragment may cause embolization, infections, or other severe complications, and therefore must be removed promptly. For a successful and low-risk removal, the fragment should be localized accurately; however, ultrasound may be challenging to perform on small dogs due to inadequate probes. We report the case of a 2-year-old, 2.6 kg, intact female toy poodle that presented to the veterinary medical center owing to a recent onion intake; the owner requested to induce emesis. A 24 gauge peripheral intravenous catheter was inserted into the cephalic vein prior to the emetic injection. When the clinician removed the catheter, a device breakage was observed. A tourniquet was applied immediately proximal to the elbow. Ultrasonography was performed with a high-frequency small-footprint linear array transducer, also called a hockey-stick probe, to localize the fragment. An additional ultrasound was performed before surgery to confirm the location of the catheter piece, which migrated 5 cm proximally. Afterward, a surgical intervention allowed us to retrieve the fragment. This report highlights the effectiveness of a hockey-stick probe to determine the location of a catheter fragment in small breed dogs.

사출성형품의 역공학에서 Geometry 정보를 이용한 정밀도 향상에 관한 연구 (A Study on Improvement of Accuracy using Geometry Information in Reverse Engineering of Injection Molding Parts)

  • 김연술;이희관;황금종;공영식;양균의
    • 한국정밀공학회지
    • /
    • 제19권10호
    • /
    • pp.99-106
    • /
    • 2002
  • This paper proposes an error compensation method that improves accuracy with geometry information of injection molding parts. Geometric information can give an improved accuracy in reverse engineering. Measuring data can not lead to get accurate geometric model, including errors of physical parts and measuring machines. Measuring data include errors which can be classified into two types. One is molding error in product, the other is measuring error. Measuring error includes optical error of laser scanner, deformation by probe forces of CMM and machine error. It is important to compensate these in reverse engineering. Least square method (LSM) provides the cloud data with a geometry compensation, improving accuracy of geometry. Also, the functional shape of a part and design concept can be reconstructed by error compensation using geometry information.

레이저 다이오드의 직접 광주파수 변조를 이용한 광섬유의 브릴루앙 이득 스펙트럼 측정 (Measurement of Brillouin Gain Spectrum of Optical Fiber Using Direct Optical Frequency Modulation of Laser Diode)

  • 서민성;윤승철;박희갑
    • 한국광학회지
    • /
    • 제17권2호
    • /
    • pp.143-148
    • /
    • 2006
  • 광섬유 내 브릴루앙 산란의 이득 스펙트럼을 측정하는 새로운 방법을 제안하고 실험하였다. 기존의 측정 방식과는 달리, 주입전류를 직접 변조하여 광주파수 변조된 하나의 레이저 다이오드로부터 펌프광과 프로브광을 발생시키고, 주입전류를 사각파로 변조할 때 나타나는 광주파수 처핑을 이용하여 펌프/프로브간 광주파수 차이를 연속적으로 변화시키는 방법으로 브릴루앙 이득 스펙트럼을 측정하였다. 통신용 단일모드 광섬유의 브릴루앙 이득 스펙트럼을 측정하여 기존 문헌의 결과와 거의 일치하는 결과를 얻었다.

유륜하 주사에 의한 유방암 환자의 전초림프절 스캔과 전초림프절 생검에 있어서 당일검사와 전날검사의 비교: 후향적 연구 (Camparison between the 1 Day and the 2 Day Protocols of Lymphoscintigraphy and Sentinel Node Biopsy using Subareolar Injection in Breast Cancer Patients: A Retrospective Study)

  • 석주원;전성민;남현열;김인주
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권1호
    • /
    • pp.55-59
    • /
    • 2009
  • 목적: 전초림프절 스캔과 전초림프절 생검은 유방암 환자에서 액와림프절 전이를 인지하기 위해서 사용되지만, 표준화된 방법이 마련되어 있지 않다. 액와림프절 전이를 인지하기 위한 전초림프절 검사에 있어서 본 연구에서는 수술당일 주사하는 당일검사와 수술전날 주사하는 전날검사의 결과를 비교하여 보았다. 대상 및 방법: 본 연구에서는 2001년에서 2004년사이에 유방암으로 수술을 시행했던 349명의 환자를 대상으로 하였다. 171명의 환자는 Tc-99m Tin-Colloid (37 MBq) 0.8 ml를 유륜하로 수술당일(1시간 전)에 주사하였다. 178명의 환자는 Tc-99m Tin-Colloid (185 MBq) 0.8 ml를 유륜하로 수술전날(16시간 전)에 주사하였다. 앉은 자세에서 림프신티그라피가 시행되었고, 수술 중에 감마프로브로 전초림프절을 발견하였다. 결과: 당일검사를 시행한 전체 171명의 환자 중에서 153명(89.5%)이 림프신티그라피에 의해 전초림프절이 발견되었고, 150명(87.7%)이 감마프로브에 의해 전초림프절이 발견되었다. 전날검사를 시행한 전체 178명의 환자 중에서 159명(89.3%)이 림프신티그라피에 의해 전초림프절이 발견되었고, 154명(86.5%)이 감마프로브에 의해 전초림프절이 발견되었다. 당일검사와 전날검사에 있어서, 림프신티그라피와 감마프로브에 의한 전초림프절 발견율의 유의한 차이는 없었다(p>0.05, p>0.05). 결론 : 유방암 환자에서 전초림프절을 발견하는데 있어 당일검사와 전날검사에 의한 차이는 없었다. 전날검사는 전초림프절 스캔을 시행할 충분한 시간을 얻을 수가 있어서, 유방암 환자에서 전초림프절을 발견하는데 더 유용할 것이다.