• 제목/요약/키워드: injection detection

검색결과 486건 처리시간 0.029초

Fault Detection and Reconstruction for Descriptor Systems with Actuator and Sensor Faults

  • Yeu, Tae-Kyeong;Matsunaga, Nobutomo;Kawaji, Shigeyasu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2582-2587
    • /
    • 2003
  • This paper proposes an application of sliding mode observer to the problem of fault detection and reconstruction for descriptor systems with both actuator and sensor faults. In detecting and reconstructing the faults simultaneously, first, we will consider the fault detection problem for sensor fault. The detection of sensor fault is achieved from the design of the matrix which eliminates the influence of actuator fault. Secondly, the sliding mode observer which adds the general full-order observer for descriptor system to feedforward injection map and feedforward compensation signal is designed, and through which the sensor fault is reconstructed. Finally, with the reconstructed sensor fault, and by eliminating differential term of the sensor fault, the actuator fault is detected and reconstructed.

  • PDF

리스테리아 식중독균 검출을 위한 광학식 바이오센서 개발 (Development of a Fiber-Optic Biosensor for the Detection of Listeria monocytogenes)

  • 김기영;최규홍
    • Journal of Biosystems Engineering
    • /
    • 제31권2호
    • /
    • pp.128-134
    • /
    • 2006
  • Frequent outbreaks of foodborne illness demand the need for rapid and sensitive methods for detection of these pathogens. Recent development of biosensor technology has a great potential to meet the need for rapid and sensitive pathogens detection from foods. An antibody-based fiber-optic biosensor and an automated reagents supply system to detect Listeria monocytogenes were developed. The biosensor for detection of Listeria monocytogenes in PBS and bacteria spiked food samples was evaluated. The automated reagents supply system eliminated cumbersome sample and detection antibody injection procedures that had been done manually. The biosensor could detect $10^4$ cfu/ml of Listeria monocytogenes in PBS. By using the fiber-optic biosensor, $2x10^8$ cfu/ml of Listeria monocytogenes in the food samples were detectable.

Flow Injective Determination of Thiourea by Amperometry

  • Lee Joon-Woo;Mho Sun-Il;Pyun Chong Hong;Yeo In-Hyeong
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권12호
    • /
    • pp.1038-1042
    • /
    • 1994
  • The amperometric responses of thiourea were studied in 0.1 M NaOH by flow injection analysis. D. C. amperometric and pulsed amperometric detection methods were applied for the determination of thiourea at novel metal electrodes such as Pt and Au. Triple-step potential waveforms were adopted in the pulsed amperometric detection. With an optimized pulsed waveform, the current for the oxidation of thiourea was examined with the variation of flow rate of carrier solution and with the change in the amount of sample injected. Gold working electrode turned out to be better in sensitivity and signal to noise ratio than Pt electrode in the pulsed amperometric detection of thiourea. Detection limit is estimated to be 5.33 ${\times}$ 10$^{-5}$ M with this detection method.

금붕어의 동작 감지에 미치는 갭 정션의 역할: 시각운동 반응 측정 (The Role of Gap Junction in the Goldfish's Motion Detection Measured with Optometer Response)

  • 이영섭;윤영현;정창섭
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.252-259
    • /
    • 2006
  • 갭 정션(gap junction)은 다양한 세포에 분포되어 있으며 분자 수준의 작은 물질들이 자유롭게 교환되는 전기적 시냅스다. 망막에서, 갭 정션의 차단이 동물의 동작 감지(motion detection)에 실제적으로 어떤 영향을 주는지에 대해서는 거의 조사되지 않았다. 본 연구에서는, 망막 세포간의 전기적 시냅스를 조절하는 약물이 금붕어의 동작 감지에 어떠한 영향을 주는지를 조사하기 위해 시각운동 반응(optometer response, OMR)이 사용되었다. 갭 정션 차단제인 carbenoxolone, 8-bromo cyclic AMP, sodium nitroprusside (SNP), 8-bromo-cyclic GMP 등의 초자체 내 주사는 광- 및 암-상태에서 모두 OMR을 감소시켰다. 광-상태에서 dopamine, SKF-38393 및 eticlopride의 주사는 OMR을 감소시킨 반면 SCH-23390의 주사는 OMR을 증가시켰다. 암-상태에서는 결과가 반대로 나타났다: 즉 dopamine, SKF-38393 및 eticlopride의 주사는 OMR을 증가시킨 반면 SCH-23390의 주사는 OMR을 감소시켰다. 이러한 결과는 망막 세포들 사이의 갭 정션이 금붕어의 동작 감지에 중요한 역할을 담당하고 있음을 시사한다.

  • PDF

룰 기반 웹 IDS 시스템을 위한 효율적인 웹 로그 전처리 기법 설계 및 구현 (Design and Implementation of Advanced Web Log Preprocess Algorithm for Rule based Web IDS)

  • 이형우
    • 인터넷정보학회논문지
    • /
    • 제9권5호
    • /
    • pp.23-34
    • /
    • 2008
  • 웹 기반 서비스가 다양한 형태로 제공되면서 웹 서비스 사용자 수는 꾸준히 증가하고 있다. 그러나 웹 서버에 대한 SQL Injection, Parameter Injection 및 DoS 등의 공격 등의 취약점이 발견되고 있다. 이와 같은 형태의 웹 공격에 능동적으로 대응하기 위해 현재 웹 IDS 시스템을 구축하여 룰 기반 대응 시스템을 구축하고 있으나, 웹 서버에서 생성되는 로그 정보에 대한 전처리 과정 없이 룰 기반 IDS 시스템이 구동되기 때문에 효율적인 웹 공격 대응체계가 구축되지 못하고 있다. 이에 본 연구에서는 웹 로그 정보를 웹 IDS 기반 공격 탐지 시스템의 룰 비교 특성에 적합한 형태로 전처리하는 알고리즘을 제시하고 이를 구현하였다. 제안한 알고리즘은 웹 로그 정보에 대한 필드 단위 파싱 및 중복 문자열 처리 과정을 고속으로 수행하여 대용량의 로그 처리시 성능을 향상시켜 개선된 웹 IDS 시스템 구축이 가능하다.

  • PDF

Enflurane 전신마취중 경막외 시험용량의 표식자로서 Isoproterenol의 효율성 (Efficacy of Isoproterenol as a Marker of Epidural Test Dose in Patients Anesthetized with Enflurane)

  • 김건식;강화자;이두익
    • The Korean Journal of Pain
    • /
    • 제14권2호
    • /
    • pp.186-192
    • /
    • 2001
  • Background: Epidural test doses containing epinephrine are an incomplete marker for the detection of inadvertent intravascular injection. Therefore, many investigators have attempted to find a more reliable marker as an alternative to epinephrine in adult patients anesthetized with enflurane. The present study was designed to test whether two different simulated intravenous test doses of isoproterenol could be used as a reliable marker for the detection of inadvertent intravascular injection in adult patients anesthetized with $O_2-N_2O$-enflurane. Methods: Forty healthy adult patients were anesthetized with 1% end-tidal enflurane and nitrous oxide after endotracheal intubation and were randomized to one of two groups according to the dose of isoproterenol. Group 1 and 2 (n = 20 each) received 3 ml of 1.5% lidocaine with 3 and 5 g isoproterenol intravenously, respectively, to simulate an intravascularly administered test dose. Heart rate (HR) and systolic blood pressure (SBP) were measured at 20-second intervals for 4 min after injection. Results: Mean maximal HR increases were $24{\pm}17$, $35{\pm}11$ bpm (P < 0.05), mean maximal SBP increases were $14{\pm}8$, $13{\pm}9$ mmHg and mean maximal SBP decreases $20{\pm}11$, $22{\pm}9$ mmHg following the IV injection of 3, $5{\mu}g$ isoproterenol, respectively. The incidence of hypotension was similar in both groups. Isoproterenol 3 and $5{\mu}g$ produced 75%, 100% sensitivity in the HR criteria ($\geq$ 20 bpm increase) and 60%, 70% sensitivity in the SBP criteria ($\geq$ 15 mmHg), respectively. Conclusions: These results indicate that based on the HR response, the epidural test dose containing $5{\mu}g$ isoproterenol to simulate an intravascular administration is a more reliable marker than $3{\mu}g$ isoproterenol in adult healthy patients during enflurane anesthesia.

  • PDF

무선 센서 네트워크에서 퍼지 로직 기반의 허위 보고서 탐지 기법 (A Fuzzy Logic-Based False Report Detection Method in Wireless Sensor Networks)

  • 김문수;이해영;조대호
    • 한국시뮬레이션학회논문지
    • /
    • 제17권3호
    • /
    • pp.27-34
    • /
    • 2008
  • 무선 센서 네트워크는 자원 제약을 가지는 센서 노드들로 이루어진다. 센서 네트워크에서 충분한 보호를 받지 못하는 노드들은 공격자들에 의해 훼손될 수 있다. 이러한 훼손된 노드들은 허위 보고서 주입 공격이나 정상 보고서에 대한 허위 데이터 주입 공격과 같은 공격들에 취약하다. 허위 보고서 주입 공격에서, 공격자는 싱크의 기만이나 배터리로 동작하는 네트워크의 제한된 에너지를 고갈을 목적으로 허위 보고서들을 네트워크에 주입한다. 정상 보고서에 대한 허위 데이터 주입 공격에서, 공격자는 모든 정상 보고서에 거짓 데이터를 주입할 수도 있다. 이러한 공격들을 다루기 위하여, Li와 Wu는 확률적 투표-기반 여과기법(PVFS)을 제안하였다. 그러나 PVFS에서 각 클러스터 헤드는 추가적인 전송 장비를 필요로 한다. 그러므로 본 논문에서는 이러한 공격들의 위협을 완화시키기 위하여 퍼지 로직-기반 허위 보고서 탐지 기법(FRD)를 제안한다. FRD는 통계적 전달 중 여과 기법을 기반으로 채택하여 이를 개선한다. 시뮬레이션에서 FRD가 제공하는 보안 능력이 효율적이며, 보안과 에너지 소비간의 트레이오프가 있음을 보인다.

  • PDF

전류측정성분과 불량정보 검출을 고려한 전력계통에서의 상태추정에 관한 연구 (State Estimation Considering Current Measurement Component and Bad Data Detection)

  • 김준현;이종범
    • 대한전기학회논문지
    • /
    • 제35권7호
    • /
    • pp.261-271
    • /
    • 1986
  • This paper describes a method for the state estimation considering current measurement component and detection of the bad data. The state values are estimated by weighted least square method in which measurement vector included bus injection current and line current. The bad data are detected using standardized variable of normal distribution and identified using sensitivity coefficients. When the bad data were occured by the bad measurement values. The results of the application to the model power system reveal the effectiveness of the presented algorithms.

  • PDF

SQL 질의 애트리뷰트 값 제거 방법을 이용한 효과적인 SQL Injection 공격 탐지 방법 연구 (A Method for SQL Injection Attack Detection using the Removal of SQL Query Attribute Values)

  • 이인용;조재익;조규형;문종섭
    • 정보보호학회논문지
    • /
    • 제18권5호
    • /
    • pp.135-148
    • /
    • 2008
  • 인터넷이 발전함에 따라 웹 애플리케이션을 이용한 서비스가 대중화되었고, 웹 애플리케이션의 취약점을 목표로 하는 공격들도 증가하게 되었다. 많은 웹 공격 중의 하나인 SQL Injection 공격은 민감한 데이터를 처리하는 곳에서는 매우 치명적이고 위험하기 때문에 이를 탐지하고 예방하기 위한 연구들이 다양하게 이루어져 왔다. 이로 인하여 SQL Injection 공격들이 많이 감소했지만 아직도 이를 우회하는 방법들이 존재하며, 기존의 연구 방법들 또한 매우 복잡하여 실제 웹 애플리케이션에 적용하여 사용하기 어렵다. 따라서 본 논문에서는 SQL Injection 공격 탐지를 위해 웹 애플리케이션에 고정되어 있는 정적 SQL 질의와 사용자로부터 생성되는 동적 SQL 질의의 애트리뷰트 값을 제거한 정적 및 동적 분석 방법을 제안하고, 실험을 통하여 효율성을 검증하였다.

로드셀과 자이로센서를 융합한 수액 감지 시스템 설계 및 오차 검증 (Design and Error Verification of Intravenous Injection Detection System that Combines Load Cell and Gyro Sensor)

  • 김선칠
    • 한국융합학회논문지
    • /
    • 제12권1호
    • /
    • pp.127-132
    • /
    • 2021
  • 의료기관에서 사용되는 수액 모니터링 시스템은 원격으로 환자에게 투입된 수액량과 투여의 종료시점 정보를 제공하기 위해서 개발되었다. 수액 투입량을 측정하기 위해서는 수액 내부에서 외부로 나가는 정량을 무게로 혹은 유량을 측정센서로 측정할 수 있다. 여기에 적용되는 장치의 기준은 정확성, 경계성이다. 또한 소형으로 환자에게 수액 설치시 사용에 용이해야 한다. 의료기관에서는 측정값의 정확도가 높아야 하며, 경제적으로 저가의 장치를 요구하고 있다. 본 연구에서는 저가의 소형 무게 중심 로드셀 센서를 적용하였으며, 측정값의 정확도를 위해 자이로센서와 융합하여 외부 움직임에 의한 아트펙트를 줄이는 알고리즘을 적용하였다. 그 결과 측정의 오차를 줄일 수 있어 수액 모니터링 측정값의 정확도를 향상시키는 효과를 확인하였다.