• 제목/요약/키워드: infrared spectroscopy

검색결과 2,103건 처리시간 0.028초

Studies on pharmaceutical assay method using Near Infrared Spectroscopy (NIRS) (II)

  • Kang, Shin-Jung;Yun, Mi-Ok;Lee, Su-Jung;Choi, Hyun-Chul;Kim, Ho-Jeong;Kim, Ji-Yeon
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.4113-4113
    • /
    • 2001
  • This study developed effective assay method of pharmaceutical quality control was developed by near-infrared spectroscopy (NIRS). The calibration equation model of assay was developed by 2nd deriviative PLS(Partial Least Squares) regression method with NIRS over the wavelength range from 1100 to 1400nm using diazepam tablets (2mg, 5mg). Although diazepam tablets are made by 5-different manufacture, they have similar formulation. When the correlation was compared with values by NIRS and HPLC, the R-2s and standard error of calibration (SEC) for 2mg were 0.9300 and 0.98%, the R-2s and SEC for 5mg were 0.9165 and 0.63%. The validation of the calibration equation model yield that the R-2s and standard error of prediction (SEP) for 2mg were 0.9611 and 0.995%, the R-2s and SEP for 5mg were 0.9114 and 0.842%. The method was validated on assay method for diazepam tablets by the calibration equation.

  • PDF

Two-dimensional near-infrared correlation spectroscopy, principal component analysis and water structure

  • Sectnan, Vegard H.;Sasic, Slobodan;Isaksson, Tomas;Ozaki, Yukihiro
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1287-1287
    • /
    • 2001
  • The structure of water molecules in the pure liquid state has been subjected to extensive research for several decades. Questions still remain unanswered, however, and no single model has been found capable of explaining all the anomalies of water. In the present study near-infrared spectra of water in the temperature region 6-$80^{\circ}C$ have been analysed by use of principal component analysis (PCA) and two-dimensional correlation spectroscopy in order to study the dynamic behaviour of the water band centred at 1440 nm, which is due to the combination of symmetric and antisymmetric O-H stretching modes. It has been found that the wavelengths 1412 and 1491 nm account for more than 99% of the spectral variation, representing two major water species with weaker and stronger hydrogen bonds, respectively. A third species located at 1438 nm, whose concentration was relatively constant as a function of temperature, is also indicated. A somewhat distorted two-state structural model for water is suggested.

  • PDF

적외선 분광분석과 다변량 통계에 기반한 바이오디젤 품질분석 (Analysis of biodiesel quality based on infrared spectroscopy and multivariate statistics)

  • 김혜실;조현우;유준
    • 분석과학
    • /
    • 제25권4호
    • /
    • pp.214-222
    • /
    • 2012
  • ASTM (American Society for Testing and Materials) D6751-10은 바이오디젤의 품질 규격 뿐 아니라 분석방법 또한 제시하고 있다. 하지만 ASTM 표준에 따른 바이오디젤 및 포함된 여러 불순물의 품질 분석은 경제적, 시간적으로 부담이 크다. 본 연구는 적외선 분광분석법(infrared spectroscopy)과 다변량 통계분석법 중 하나인 PLS (partial least square method)를 이용하여 1회 측정만으로 바이오 디젤 및 불순물들의 농도를 분석하는 시스템을 개발하고자 하였다. 특히, 적외선을 이용한 분석에서 생기는 각 물질의 스펙트럼에 대한 산란 보정, 노이즈 감소 등을 위해 SNV, MSC, OSC, Savitzky-Golay 등의 4가지 전처리 방법의 성능을 비교하였다. 품질 분석에 필요한 바이오 디젤 검량 모델을 PLS로 모델링 결과, Savitzky-Golay 전처리를 하였을 때 정확도가 가장 우수함을 알았다.

일본의 근적외선분광법에 대한 제약회사 응용 및 현황 (Application Study of Chemoinfometrical Near-Infrared Spectroscopic Method to Evaluate for Polymorphic Content of Pharmaceutical Powders)

  • Otsuka, Makoto
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2002년도 강연요지집
    • /
    • pp.97-117
    • /
    • 2002
  • A chemoinfometrical method for quantitative determination of crystal content of indomethacin (IMC) polymorphs based on fourie-transformed near-infrared (FT-NIR) spectroscopy was established. A direct comparison of the data with the ones collected from using the conventional powder X-ray diffraction method was performed. Pure $\alpha$ and ${\gamma}$ forms of IMC were prepared using published methods. Powder X-ray diffraction profiles and NIR spectra were recorded for six kinds of standard materials with various content of ${\gamma}$ form IMC. The principal component regression (PCR) analyses were performed based on normalized NIR spectra sets of standard samples of known content of IMC ${\gamma}$ form. A calibration equation was determined to minimize the root mean square error of the prediction. The predicted ${\gamma}$ form content values were reproducible and had a relatively small standard deviation. The values of ${\gamma}$ form content predicted by two methods were in close agreement. The results were indicated that NIR spectroscopy provides for an accurate quantitative analysis of crystallinity in polymorphs compared with the results obtained by conventional powder X-ray diffractometry.

  • PDF

AKARI IRC INFRARED 2.5-5 ㎛ SPECTROSCOPY OF NEARBY LUMINOUS INFRARED GALAXIES

  • Imanishi, Masatoshi;Nakagawa, Takao;Shirahata, Mai;Ohyama, Yoichi;Onaka, Takashi
    • 천문학논총
    • /
    • 제27권4호
    • /
    • pp.271-274
    • /
    • 2012
  • We present the result of systematic AKARI IRC infrared $2.5-5{\mu}m$ spectroscopy of >100 nearby luminous infrared galaxies, to investigate the energetic roles of starbursts and optically-elusive buried AGNs. Based on (1) the equivalent widths of the $3.3{\mu}m$ PAH emission features, (2) the optical depths of absorption features, and (3) continuum slopes, we can disentangle emission from starbursts and AGNs. We find that the energetic importance of buried AGNs increases with increasing galaxy infrared luminosities, suggesting that the AGN-starburst connections (and thereby possible AGN feedback to host galaxies) are luminosity dependent.

INLINE NEAR INFRARED (NIR) SPECTROSCOPY FOR PROCESS CONTROL IN POLYMER EXTRUSION

  • Rohe, Thomas;Koelle, Sabine;Becker, Wolfgang;Eisenreich, Norbert;Eyerer, Peter
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1082-1082
    • /
    • 2001
  • Extrusion is one of the most important processes in polymer industry. The characterization of the polymer melt during processing will improve this process noticeably, One possibility of characterizing the actual processed polymer melt is the inline near infrared (NIR) spectroscopy, With this method several polymer properties can be observed during processing, e.g. composition, moisture ormechanical properties of the melt. For this purpose probes for transmission and reflection measurements have been developed, withstanding the high temperatures and pressures appearing during extrusion process (tested up to 300$^{\circ}C$ and 10 ㎫). For the transmission system an optical bypass was developed to eliminate disturbing spectral influences and hence increase the long term stability, which is the prerequisite for an industrial application. Measurements in transmission and reflection produced comparable results (or blending processes, where the prediction error was less than 1%. An optimum RMSEP of only 0.24% was found for preprocessed polymer blends measured in transmission on a laboratory extruder. A transflection measurement allowed for the first time the recording of relevant NIR-spectra in the screw area of an extruder. The application to a (PE+PP) blending process delivered promising results. This new measurement mode allows the observation of the ongoing processes within the screw area, which is of maximum Interest for reactive extrusion processes. Due to economic reasons the calibration transfer between different extrusion systems is also of high importance. Investigations on simulated and real-world spectra showed that a calibration transfer is possible. A new method alternatively to the well-known direct standardization procedures was developed, which is based on an automatic data pretreatment. This procedure delivers comparable results for the calibration transfer. Overall this paper presents concepts, components and algorithms for the inline near infrared (NIR) spectroscopy for polymer extrusion, which allows the use of it in a real industrial extrusion process.

  • PDF

Polymerization of Tetraethoxysilane by Using Remote Argon/dinitrogen oxide Microwave Plasma

  • Chun, Tae-Il;Rossbach, Volker
    • 한국염색가공학회지
    • /
    • 제21권3호
    • /
    • pp.19-25
    • /
    • 2009
  • Polymerization of tetraethoxysilane on a glass substrate was investigated by remote microwave plasma using argon with portions of nitrous oxide as carrier gas. Transparent layer like a thickness of 0.5 ${\mu}m$ 3 ${\mu}m$ were obtained, differing in chemical composition, depending on plasma power and treatment time as well as on ageing time. In general the milder the treatment and the shorter the ageing was, the higher was the content of organic structural elements in the layer. We have identified that the chemical structure of our samples composed of mainly Si O and Si C groups containing aliphatics, carbonyl groups. These results were obtained by X ray photon spectroscopy, Fourier transformed infrared spectroscopy, and scanning electron microscope combined with Energy dispersive X ray spectroscopy.

Nondestructive Determination of Humic Acids in Soils by Near Infrared Reflectance Spectroscopy

  • Seo, Sang-Hyun;Park, Woo-Churl;Cho, Rae-Kwang;Xiaori Han
    • Near Infrared Analysis
    • /
    • 제1권1호
    • /
    • pp.31-35
    • /
    • 2000
  • Near-infrared reflectance spectroscopy(NIRS) was used to determine the humic acids in soil samples from the fields of different crops and land-use over Youngnam and Honam regions in Korea. An InfraAlyzer 500 scanning spectrophotometer was obtained near infrared relectance spectra of soil at 2-nm intervals from 1100 to 2500nm. Multiple linear regression(MLR) or partial least square regression (PLSR) was used to evaluate a NIRS method for the rapid and nondestructive determination of humic acid, fulvic acid and its total contents in soils. The raw spectral data(log 1/R) can be used for estimating humic acid, fulvic acid and its total contents in soil by MLR procedure between the content of a given constituent and the spectral response of several bands. In which the predicted results for fulvic acid is the best in the constituents. The new spectral data are converted from the raw spectra by PLSR method such as the first derivative of each spectrum can also be used to predict humic acid and fulvic acid of the soil samples. A low SEC, SEP and a high coefficient of correlation in the calibration and validation stages enable selection of the best manipulation. But a simple calibration and prediction method for determining humic acid and fulvic acid should be selected under similar accuracy and precision of prediction. NIRS technique may be an effective method for rapid and nondestructive determination for humic acid, fulvic acid and its total contents in soils.

중적외선 영역의 무반사 코팅된 ZnS 기판의 설계와 광학 특성 (Design and Analysis of Optical Properties of Anti-reflection Coated ZnS Substrates in the Mid-infrared Region)

  • 박범근;백종후
    • 센서학회지
    • /
    • 제31권4호
    • /
    • pp.255-259
    • /
    • 2022
  • In this study, we fabricated ZnS substrates with excellent transmittance in the mid-infrared region (3-5 ㎛) using hot pressing instead of conventional chemical vapor deposition (CVD). Diamond-like carbon (DLC) was coated on either one or both sides of the ZnS substrates to improve their mechanical properties and transmittance efficiency. To reduce the reflectance and further improve transmittance in the mid-infrared region, anti-reflection (AR) coating was designed for DLC/ZnS /AR and AR/ ZnS /AR structures. The coating structure, microstructure, and optical properties of the AR-coated ZnS substrates were subsequently investigated by employing energy dispersive X-ray spectroscopy, scanning electron microscopy, and Fourier-transform infrared (FTIR) spectroscopy. The FTIR spectroscopy results demonstrated that, in the mid-infrared region, the average transmittance of the samples with AR coating on one and both sides increased by approximately 18% and 27%, respectively. Thus, AR coating improved the transmittance of the ZnS substrates.

Measurement of lipid content of compost fermentation using near-infrared spectroscopy

  • Daisuke Masui;Suehara, Ken-ichiro;Yasuhisa Nakano;Takuo Yano
    • Near Infrared Analysis
    • /
    • 제2권1호
    • /
    • pp.37-42
    • /
    • 2001
  • Near infrared spectroscopy (NIRS) was applied to determination of the lipid content of the compost during the compost fermentation of tofu (soybean0curd) refuse. The absorption of lipid observed at 5 wavelengths, 1208, 1712, 1772, 2312 and 2352 nm on the second derivative spectra. To formulated a calibration equation, a multiple linear regression analysis was carried out between the near-infrared spectral data and on the lipid content in the calibration sample set (sample number, n=60) obtained using Soxhlet extraction method. The value of the multiple correlation coefficient (R) was 0.975 when using the wavelengths of 1208 and 1712 nm were used in the calibration equation. To validate the calibration equation obtained, the lipid content in the validation sample set (n=35) not used for formulating the calibration equation was calculated using the calibration equation, and compared with the value obtained using the Soxhlet extraction method. Good agreement was observed between the results of the Soxhlet extraction method and those values of the NIRS method. The simple correlation coefficient (r) and standard error of prediction (SEP) were 0.964 and 0.815 %, respectively. suitability of the lipid content as an indicator of the compost fermentation of tofu refuse was also studied. The decrease of the lipid content in the compost corresponded to the decrease of the total dry weight of the compost in the composter. The lipid content was a significant indicator of the compost fermentation. The NIRS method was applied to measure the time course of the lipid content in the compost fermentation and good results were obtained. The study indicates that NIRS is a useful method for process management of the compost fermentation of tofu refuse.