• 제목/요약/키워드: infrared spectra

검색결과 855건 처리시간 0.028초

THE 3.3 MICRON PAH EMISSION OF THE MID-INFRARED EXCESS GALAXIES DISCOVERED BY THE AKARI MID-INFRARED ALL-SKY SURVEY

  • Yamada, R.;Oyabu, S.;Kaneda, H.;Yamagishi, M.;Ishihara, D.;Kim, J.H.;Im, M.;Toba, Y.;Matsuhara, H.
    • 천문학논총
    • /
    • 제27권4호
    • /
    • pp.299-300
    • /
    • 2012
  • We investigate the relation between star formation activity and PAH $3.3{\mu}m$ emission. Our targets are mid-infrared-excess galaxies selected from the AKARI all-sky survey point source catalog. We performed AKARI near-infrared spectroscopy for them. As a result, we obtained $2.5-5{\mu}m$spectra of 79 galaxies, and selected 35 star-forming galaxies out of them. Comparing the PAH $3.3{\mu}m$ luminosities with the infrared luminosities, we find a linear correlation between them. However, by adding the results from literatures for luminous infrared galaxies and ultra-luminous infrared galaxies that are more luminous than our sample, the ratio of the PAH to the infrared luminosity is found to decrease towards the luminous end.

SOURCES OF NON-LINEARITY IN NIR SPECTRA OF SCATTERING SAMPLES

  • Dahm, Donald J.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1011-1011
    • /
    • 2001
  • In general, NIR reflectance spectra (whether recorded using log(1/R) or the Kubelka-Munk function) are not linear functions of the concentration of the absorbers which we are measuring. There are several causes for this non-linearity, the most commonly cited one being front surface reflection. However, non-linearity also arises from the effects of particle size, sample thickness, void fraction, and experimental arrangement. In this talk, we will attempt to isolate the effects of the various causes, and show the effects of each, using both theoretical calculations and actual data. The listener should then be able to assess where we stand in our quest to produce “linear” data through pre-processing and/or alternate collection schemes.

  • PDF

Pitfall in calibration development - "chance correlation + wishful thinking" - an example of pH determination in grass silages

  • Tillmann, Peter;Horst, Hartmut
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1275-1275
    • /
    • 2001
  • The pH value of grass silages is one important parameter to determine the quality of the forages. In an attempt to use NIRS spectra taken for other quality parameter of grass silage it has been shown that a good correlation between NIR spectra of the dried forage and pH value of the fresh forage could be determined. Further investigations revealed that the B coefficients of the pH value calibration were almost the same as the B coefficients of the sugar calibration multiplied with -1. And indead the pH value - in the fresh sample material - of the calibration set is strongly correlated with the sugar concentration - in the dried sample material. It is concluded that next to scientific tools in research the scientist and the user of NTRS equippment has to scrutinze his own work. Examples are given. NIRS is a powerfull technique, but pitfalls are present in surplus.

  • PDF

근적외선 분광분석법을 이용한 LAS (linear alkyl benzene sulfonate)의 정량분석법 (Near Infrared Spectroscopy of LAS (linear alkyl benzene sulfonate))

  • 조창희;최병기;김효진
    • Environmental Analysis Health and Toxicology
    • /
    • 제15권1_2호
    • /
    • pp.39-43
    • /
    • 2000
  • Linear alkyl sulfonates (LAS) constitute a large fraction of the surfactants used in cleaning processes in households, trade and industry Despite the industrial significance and the possible environmental impact of these compounds, the fast and inexpensive determination of LAS concentrations is still a difficult task. In this study, near infrared (NIR) spectroscopy which is a rapid spectroscopic analysis method compared with a traditional analytical method for the measurement of LAS concentration such as HPLC, GC and standard wet chemistry method. NIR spectra of LAS between 0.313 and 25.0% (w/v) in water were utilized to develop a calibration model. The best results (R = 0.998, SEP = 0.244% (w/v)) obtained by using partial least-squares regression with spectral data treatment and 2nd derivatization were comparable to the results (SEC = 0.186% (w/v), SEP = 0.206% (w/v)) obtained by using multiple linear least-squares regression (MLR). However, models based on derivative spectra have no significant advantage with MLR.

  • PDF

Generation of Si-O-C Bond without Si-$CH_3$ Bond in Hybrid Type SiOC Film

  • Oh, Teresa
    • 반도체디스플레이기술학회지
    • /
    • 제7권3호
    • /
    • pp.1-4
    • /
    • 2008
  • The chemical shift of SiOC film was observed according to the flow rate ratio. SiOC film had the broad main band of $880\sim1190cm^{-1}$ and the sharp Si-$CH_3$ bond at $1252cm^{-1}$, and the peak position of the main bond in the infrared spectra moved to high frequency according to the increasing of an BTMSM flow rate. So the increment of the alkyl group induced the C-H bond condensation in the film, and shows the blueshift in the infrared spectra. In the case of P5000 system of Applied Materials Corporation, the strong bond of Si-CH3 bond in precursor does not enough to dissociated and ionized, because low plasma energy due to the capactive coupled CVD. Therefore, there was the sharp peak of Si-$CH_3$ bond at $1252cm^{-1}$.

  • PDF

Matrix Infrared Spectra and DFT Computations of 2H-Azirine Produced from Acetonitrile by Laser-Ablation Plume Radiation

  • Cho, Han-Gook
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권7호
    • /
    • pp.2093-2096
    • /
    • 2014
  • 2H-azirine, a less known acetonitrile isomer, is observed in matrix IR spectra from the precursor exposed to radiation from laser ablation of transition-metals. Its vibrational characteristics confirm the previous results, and those for the deuterated and $^{13}C$ substituted isotopomers are also newly reported. The weak absorptions are traced to the low production yield due to its high energy and low extinction constants. IRC computations reveal smooth inter-conversion between 2H-azirine and $CH_2NCH$, providing a rationale for the observed variation of their relative contents during photolysis.

Observation of Elusive CF2Cl…Cl in Matrix Infrared Spectra and Density Functional Calculations

  • Cho, Han-Gook
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3274-3278
    • /
    • 2013
  • $CF_2Cl{\cdots}Cl$, an elusive photo-isomer of $CF_2Cl_2$, has been observed in matrix IR spectra from the precursors exposed to radiation from laser ablation of transition-metals. Other plausible products, $CFCl_2{\cdots}F$ and $FClC{\cdots}F-Cl$ are not detected due to their considerably higher energies. Parallel to its previously reported analogues, the C-X bonds are considerably stronger than those of the reactant, and particularly the Cl atom that is weakly bound to the residual Cl atom forms an unusually strong carbon-halogen bond. NBO analysis reveals that the C-Cl bond is a true double bond, and the weak $Cl{\cdots}Cl$ bond is largely ionic, $F_2C=Cl^{\delta+}{\cdots}Cl^{\delta-}$. IRC computation reproduces smooth inter-conversion between the reactant and product, and the transition state is energetically close to the product, consistent with its prompt disappearance in the early stage of photolysis.

유전체 혼합 법칙을 이용한 $(Pb_{0.5}Ca_{0.5})(Fe_{0.5}Ta_{0.5})O_3$세라믹스의 마이크로파 유전특성 평가 (Evaluation of Microwave Dielectric Properties in $(Pb_{0.5}Ca_{0.5})(Fe_{0.5}Ta_{0.5})O_3$ Ceramics by the Dielectric Mixing Rule)

  • 박흥수;윤기현;김응수
    • 한국세라믹학회지
    • /
    • 제37권3호
    • /
    • pp.240-246
    • /
    • 2000
  • The microwave dielectric properties of the complex perovskite (Pb0.5Ca0.5)(Fe0.5Ta0.5)O3 ceramics were investigated with the porosity and the dielectric mixing rule. Assuming that the specimens were mixtures of real dielectrics and pores, with 3-0 connectivity, the ionic polarizabilities modified by Maxwell's equation were more close to the theoretical values rather than those modified by Wiener's equation in porous specimens. The theoretical dielectirc loss were obtained with the infrared reflectivity spectra from 50 to 4000cm-1, which were calculated by Kramers-Kronig analysis and classical osciallator model. The relative tendency of dielectric loss calculated from the theoretical value and Maxwell's equation in the specimens with different porosities was in good agreement with the one by the post resonant method.

  • PDF

MEDIUM RESOLUTION SPECTRAL LIBRARY OF LATE-TYPE STELLAR TEMPLATES IN NEAR-INFRARED BAND

  • ;박수종;임명신;강원석;이상각;;표태수
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.69.2-69.2
    • /
    • 2011
  • We present medium resolution spectra in the near-infrared (IR) band 1.4-1.8 microns at a resolving power of R = 5000-10000 of template stars in G, K, and M types with luminosity classes of III observed by the echelle spectrometer, IRCS, at the SUBARU 8.2 m telescope. Identification of lines in the template star spectra has been completed base on the reference of Arcturus spectrum. We measured equivalent width (EW) of the lines, and analyze the trends of EW through the stellar spectral types.

  • PDF

A Spatial-domain Fourier Transform Infrared Spectrometer: Application for Analyte Measurement in Cell Culture Media

  • Jung, Byung-Jo
    • Journal of the Optical Society of Korea
    • /
    • 제9권4호
    • /
    • pp.151-156
    • /
    • 2005
  • A spatial-domain Fourier Transform (FT) infrared (IR) spectrometer coupled with a PtSi Schottky­barrier IR detector plane was developed in the spectral range of $2.0-2.5{\mu}m$ for noninvasive measurement of analyte concentrations in cell culture media during cell culture processing. A key optical component of the spectrometer is a Savart plate which is a birefringent polarizer generating coherent two rays for interfering. The spectral resolution of the spectrometer was determined as $71cm^{-1}$ (${\~}0.05{\mu}m$ at $2.5{\mu}m$). Clear IR fringe patterns were imaged on the IR detector plane. The feasibility of the spectrometer for our application was investigated by measuring absorbance spectra of glucose and fetal bovine serum (FBS) which are important compounds in cell culture media. Experiment results show that the spectral quality of glucose and FBS was comparable with the standard spectra acquired with a commercial FT-IR spectrometer, presenting the feasibility of the spectrometer to perform analyte measurement in cell culture media.