• Title/Summary/Keyword: infrared radiological materials

Search Result 5, Processing Time 0.024 seconds

Effects of far infrared radiological materials on immune response and changes of fecal microorganism in pigs (돼지에 있어 원적외선 방사물질의 첨가가 면역반응 및 분중 미생물의 변화에 미치는 영향)

  • Kwon, Ki-bum;Kim, In-ho;Hong, Jong-wook;Moon, Tea-hyun;Choi, Sang-yul;Seok, Ho-bong
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.1
    • /
    • pp.37-42
    • /
    • 2001
  • This research was conducted to investigate the effects of far infrared radiological materials on growth performance, immune response and changes of microbial flora in feces for growing pigs. Twelve growing pigs($Duroc{\times}Yorkshire{\times}Landrace$, average initial body weight of $15.6{\pm}0.5kg$) were used in a 40 day growth assay. Treatments were control(saline injection with diet: S); saline injection with Bio-Plus in diet(SBP); and vaccination with Bio-Plus in diet(VBP) in a randomized complete block design with initial BW as the blocking criterion. Serum concentrations of IgG of SBP and VBP were higher than those of S at day 10(p<0.05), 20(p<0.05), 30(p<0.05) and 40(p<0.05). Pigs fed with treatment diets had increased lymphocyte level compared to S at day 20(p<0.05) and 40(p<0.05). Cortisol was lower in treatments than in S at day 30(p<0.05). At day 20, there was no significant difference in E. coli among the treatments. However, it was observed that E, coli of the treatments was decreased compared to S at day 40(p<0.01). Lactobacillus of SBP was significantly higher(p<0.05) than that of S at day 40. In conclusion, the results of the experiment suggest that far infrared radiological materials could be a very beneficial immune response for growing pigs in health aspects.

  • PDF

Small Target Detecting and Tracking Using Mean Shifter Guided Kalman Filter

  • Ye, Soo-Young;Joo, Jae-Heum;Nam, Ki-Gon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.187-192
    • /
    • 2013
  • Because of the importance of small target detection in infrared images, many studies have been carried out in this area. Using a Kalman filter and mean shift algorithm, this study proposes an algorithm to track multiple small moving targets even in cases of target disappearance and appearance in serial infrared images in an environment with many noises. Difference images, which highlight the background images estimated with a background estimation filter from the original images, have a relatively very bright value, which becomes a candidate target area. Multiple target tracking consists of a Kalman filter section (target position prediction) and candidate target classification section (target selection). The system removes error detection from the detection results of candidate targets in still images and associates targets in serial images. The final target detection locations were revised with the mean shift algorithm to have comparatively low tracking location errors and allow for continuous tracking with standard model updating. In the experiment with actual marine infrared serial images, the proposed system was compared with the Kalman filter method and mean shift algorithm. As a result, the proposed system recorded the lowest tracking location errors and ensured stable tracking with no tracking location diffusion.

Sterilization Effect by the Nd:YAG Laser pulse (Nd:YAG 레이저 펄스에 따른 멸균효과)

  • Jeong, Kyeonghwan;Jung, Dongkyung;Park, Jeongkyu;Choi, Hyeonwoo;Seo, Jeongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.695-703
    • /
    • 2020
  • The use of medical devices is increasing due to the development of medical technology. Among medical devices, it is often used in the human body for graft and treatment. Therefore, in medical institutions, various sterilization methods according to the type and material of medical devices are applied to prevent infection. Hydrophosphite (HA) materials are the most popular in bone grafts. We would like to present a sterilization method using Q-switch Nd:YAG laser with high output energy among non-ionizing radiation suitable for small medical devices. In this study, sterilization power was most ideally shown at UV wavelengths of 1.5 W, 266 nm, and 10 pulses. Different wavelength bands; infrared and visible light; showed passive sterilization, and ultraviolet A and C showed differences in sterilization according to the pulse. In laser sterilization were differences that found according to the wavelength bands and pulses.

Detecting Incipient Caries Using Front-illuminated Infrared Light Scattering Imaging

  • Kim, Ji-Young;Ro, Jung-Hoon;Jeon, Gye-Rok;Kim, Jin-Bom;Ye, Soo-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.6
    • /
    • pp.310-316
    • /
    • 2012
  • A new method for early caries diagnosis was proposed and tested through a home-made optical examination system that used quantitative light fluorescence (QLF) and digital imaging fiber optic transillumination (FOTI) (DIFOTI), with light sources across a wide spectral range, from 350 nm to 1,000 nm. The front-illuminated infrared light scattering image (FIR) showed similar diagnostic abilities to that of DIFOTI. The FIR method was invented based on the observation that caries lesions lose the high transmittance and low scattering properties of benign enamel tissue. There are various methods for the early diagnosis of caries, such as visual examination, exploration, X-ray radiography, QLF, FOTI, and infrared fluorescence (diagnodent). Among them, methods based on optical properties are regarded as having the most potential. A comparative study was performed between the FOTI, QLF, diagnodent, optical coherence tomography, and FIR scattering image methods, using 20 extracted teeth samples with early caries. A scale of lesion measurement based on optical image contrast was proposed. The statistical analysis showed a significant correlation between the DIFOTI and FIR methods (r = 0.35, p < 0.05). However, the QLF and diagnodent methods showed little association with FIR images, as they have different detection principles as compared with FIR. Tomographic images obtained by OCT, using 1,330 nm super luminescent LED as a gold standard of tooth structure, verified that the FOTI and FIR results correctly represented the lack of homogeneity in dental tissue. The newly proposed FIR method attained similar diagnostic results to those of FOTI, but with an easier approach.

Effects of Yucca Extract and (or) Far Infrared Emitted Materials Supplementation on the Growth Performance, Serum Characteristics and Ammonia Production of Growing and Finishing Pigs

  • Hong, J.W.;Kim, I.H.;Moon, T.H.;Kwon, O.S.;Lee, S.H.;Kim, Y.G.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.9
    • /
    • pp.1299-1303
    • /
    • 2001
  • For the Exp. 1, a total of fifty four crossbred [(Duroc Yorkshire)${\times}$Landrace] pigs ($77.67{\pm}1.42kg$ average initial BW) were used in a 41-d growth assay to determine the effects of yucca extract supplementation on growth performance, nutrient digestibility and serum characteristics of finishing pigs. Dietary treatments included 1) Control (basal diet), 2) YE60 (basal diet+60 ppm yucca extract), 3) YE120 (basal diet+120 ppm yucca extract). Average daily gain was not improved by yucca extract supplementation during the whole experimental perid (d 0 to 41). Pigs fed control diet showed the best average daily gain. Pigs fed control and YE120 diets tended to increase average daily feed intake compared with pigs fed YE60 diet (quadratic effect, p<0.0001). Gain/feed with control treatment was significantly better than the YE groups (linear effect, p<0.071). However, there was no significant difference among levels of yucca extract (p>0.10). Apparent digestibility of dry matter in pigs fed yucca extract were greater than for pigs fed control diets (linear effect, p<0.017). Pigs fed YE120 tended to have higher digestibility of nitrogen than pigs fed the control diets (linear effect, p<0.019). There were no significant differences in Total-, HDL- and LDL-cholesterol concentrations of serum, and the blood urea nitrogen (BUN) concentrations in serum was not influenced by the yucca extract supplementation (p>0.10). For the Exp. 2, fifteen [(Duroc${\times}$Yorkshire)${\times}$Landrace] pigs ($25.00{\pm}0.50kg$ average initial BW) were used in a 30-d metabolism experiment to determine the effects of yucca extract supplementation on fecal ammonia gas production. Treatments were : 1) Control (basal diet); 2) YE (basal diet+150 ppm yucca extract); 3) BD (basal diet+100 ppm Bio-Dr; yucca extract+far infrared emitted materials). Fecal ammonia gas production differences between d 0 and d 30 were significantly reduced (p<0.05) by feeding BD compared to control and YE. Also, when pigs were fed the diet with YE tended to be decreased ammonia gas production compared to pigs fed the control diet without significant differences (p>0.05). There were no differences for DM and N digestibility among pigs fed the treatment diets. In conclusion, yucca and (or) far infrared radiological materials can be used to make environment-friendly diets for growing-finishing pigs without negative effects on growth performance and nutrient digestibility.