• Title/Summary/Keyword: information measurement

Search Result 8,368, Processing Time 0.035 seconds

Statistical analysis of KNHANES data with measurement error models

  • Hwang, Jinseub
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.3
    • /
    • pp.773-779
    • /
    • 2015
  • We study a statistical analysis about the fifth wave data of the Korea National Health and Nutrition Examination Survey based on linear regression models with measurement errors. The data is obtained from a national population-based complex survey. To demonstrate the availability of measurement error models, two results between the general linear regression model and measurement error model are compared based on the model selection criteria which are Akaike information criterion and Bayesian information criterion. For our study, we use the simulation extrapolation algorithm for measurement error model and the jackknife method for the estimation of standard errors.

A Study on Development of Integration Performance Measurement Model for Each Stage of Information Systems Integration and Measurement Indicators of Physical Integration Stage (정보시스템 통합단계별 성과측정 모형 및 물리적 통합단계의 측정지표 개발에 관한 연구)

  • Jung, Hae-Yong;Ra, Jong-Hei
    • Journal of Information Technology Services
    • /
    • v.7 no.4
    • /
    • pp.247-268
    • /
    • 2008
  • This study aims to develop an integration performance measurement model for each stage of information systems integration. In order to achieve the purpose of the research, first of all, the concepts of IS integration or consolidation are analyzed through theoretical and practical reviews. Also, a number of important studies of domestic and overseas cases about the stage models of IS integration or consolidation are critically reviewed. Second, we proposed three step stage model of is integration, Physical Integration stage, Application Integration stage, Service Integration stage, and Also proposed the performance measurement model for each stage of information systems integration. Third, especially in case of performance indicators and performance measurement methodology for physical integration stage are illustratively proposed, based upon the case of NCIA (National Computing Integration Agency) in Korea. This study provides the theoretical basis for reasonably deriving the stage model and performance measurement model for each stage of Information Systems Integration, and they are validating through investigating domestic and foreign practices. The results of this study are very likely to contribute to presenting the practical guideline for desirably implementing is integration or IS consolidation.

Considerations for error factors in four measurement systems determined in JEITA standard ED2523 (Measuring methods for matrix reflective LCD modules)

  • Narutaki, Yozo;Sakai, Eiji;Shimizu, Shinji;Tsuda, Keisuke;Uehara, Masao;Uehara, Toshinori;Katoh, Shinsuke;Yoda, Yuji
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1362-1365
    • /
    • 2008
  • ED-2523 (Measuring methods for matr ix reflective LCD modules) was published by JEITA (Japan Electronics and Information Technology Industries Association) in 2001. Since then, round robin tests had been done and the accuracy of measurement values had been discussed. In this paper, considerations for error factors in four measurement systems are showed.

  • PDF

Design of a MEMS sensor array for dam subsidence monitoring based on dual-sensor cooperative measurements

  • Tao, Tao;Yang, Jianfeng;Wei, Wei;Wozniak, Marcin;Scherer, Rafal;Damasevicius, Robertas
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.10
    • /
    • pp.3554-3570
    • /
    • 2021
  • With the rapid development of the Chinese water project, the safety monitoring of dams is urgently needed. Many drawbacks exist in dams, such as high monitoring costs, a limited equipment service life, long-term monitoring difficulties. MEMS sensors have the advantages of low cost, high precision, easy installation, and simplicity, so they have broad application prospects in engineering measurements. This paper designs intelligent monitoring based on the collaborative measurement of dual MEMS sensors. The system first determines the endpoint coordinates of the sensor array by the coordinate transformation relationship in the monitoring system and then obtains the dam settlement according to the endpoint coordinates. Next, this paper proposes a dual-MEMS sensor collaborative measurement algorithm that builds a mathematical model of the dual-sensor measurement. The monitoring system realizes mutual compensation between sensor measurement data by calculating the motion constraint matrix between the two sensors. Compared with the single-sensor measurement, the dual-sensor measurement algorithm is more accurate and can improve the reliability of long-term monitoring data. Finally, the experimental results show that the dam subsidence monitoring system proposed in this paper fully meets the engineering monitoring accuracy needs, and the dual-sensor collaborative measurement system is more stable than the single-sensor monitoring system.

Measurement Coding for Compressive Sensing of Color Images

  • Dinh, Khanh Quoc;Trinh, Chien Van;Nguyen, Viet Anh;Park, Younghyeon;Jeon, Byeungwoo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • From the perspective of reducing the sampling cost of color images at high resolution, block-based compressive sensing (CS) has attracted considerable attention as a promising alternative to conventional Nyquist/Shannon sampling. On the other hand, for storing/transmitting applications, CS requires a very efficient way of representing the measurement data in terms of data volume. This paper addresses this problem by developing a measurement-coding method with the proposed customized Huffman coding. In addition, by noting the difference in visual importance between the luma and chroma channels, this paper proposes measurement coding in YCbCr space rather than in conventional RGB color space for better rate allocation. Furthermore, as the proper use of the image property in pursuing smoothness improves the CS recovery, this paper proposes the integration of a low pass filter to the CS recovery of color images, which is the block-based ${\ell}_{20}$-norm minimization. The proposed coding scheme shows considerable gain compared to conventional measurement coding.

Aging Measurement and Compensation for OLED Panel (OLED 패널의 노화 측정 및 보상)

  • Jeong, Kyung-Joong;Jeong, Hong
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1009-1010
    • /
    • 2008
  • This paper presents a real-time aging measurement and feasible compensation system for the prolonged lifetime of OLED panel. The proposed system is composed of four parts, a PC with a man-machine interface, a measurement block, an adaptive amplifier block, and a compensation block. We apply a tree algorithm for less complexity and convenience of measurement on the degree of aging. An adaptive multi-stage differential amplifier is also implemented to deal with a various range of input voltages at the same spot.

  • PDF

Errors in Recorded Information and Calibration of a Catchment Modelling System(I) - Analysis of Measurement Errors in Recorded Information - (기록치 오차와 유역모형의 검정(I) - 기록치 내의 측정 오차 분석 -)

  • Kyung Sook Choi;James E. Ball
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.5
    • /
    • pp.110-116
    • /
    • 2003
  • A catchment modelling system is the summation of the numerous hydrologic, hydraulic and other process models necessary to simulate the response of a catchment to a storm event. Differences between the recorded catchment response and that predicted by a catchment modelling system can arise from structural errors within the catchment modelling system, evaluation errors in the control parameters, or measurement errors in the recorded data being used to assess the reliability of the evaluation of the control parameters. Presented herein is an investigation of the potential measurement errors within the recorded information, which was considered to occur from instrument error in the ultra sonic flow monitor. This investigation was undertaken using three available rating curves at the Musgrave Avenue Stormwater System in Centennial Park, Sydney, developed by Abustan (1997), Water Board (1994), and using Manning's equation.

Development of Portable Atmospheric Environment Measurement System using Low Power Wireless Communication

  • Chae, Soohyeon;Kim, Hack-Yoon;Gim, Jangwon
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.1
    • /
    • pp.99-109
    • /
    • 2020
  • As environmental pollution has become severe due to the rapid increase in pollutant generation in the air, measurement, collection, and analysis of atmospheric environment information plays an important role. However, it is difficult to measure the high-resolution and real-time atmospheric environment of the cities and tourist spots with high population mobility only by measuring equipment of stationary measuring stations. Therefore, this paper proposes a portable atmospheric environment measurement system for real-time measurement and monitoring of atmospheric environment information. The proposed system is a portable client with a low-power wireless communication method. It is possible to reliably transmit and receive the measured data through a multi-threaded server to monitor the trend of pollutants in the air in real-time.

Development and Validation of Privacy Concern Measurement Tool in Personal Medical Information (개인의료정보 프라이버시 염려 측정도구 개발 및 타당도 검증)

  • Lee, Kiho;Chung, Youngchul;Han, Kyeongseok;Song, Taemin
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.6
    • /
    • pp.197-208
    • /
    • 2014
  • In an information society, privacy protection is one of the most important ethical issues. In medical institutes in which personal medical information is collected and stored, in addition, a privacy breach can cause a serious damage on personal lives. This study attempted to develop privacy concern measurement tool in personal medical information to measure patients' concern on their medical information from medical service consumers' perspective and verify its validity. For this, privacy concern measurement tool in personal medical information was developed based on the results of previous studies. After performing Exploratory Factor Analysis(EFA) and Confirmatory Factor Analysis(CFA) on the measurement tool, its reliability and validity were verified. It appears that the measurement tool would be useful in developing decent privacy protection policy after investigating citizens' concern on the protection of personal medical information and domains they are interested in. For medical institutes as well, they would be helpful in coming up with a reasonable plan after figuring out problems in the protection of personal medical information and current status.

Developing a Performance Information Integration Method (PIIM) (성과 정보 통합 방법의 개발)

  • Park, Chang-Kyu
    • IE interfaces
    • /
    • v.11 no.3
    • /
    • pp.41-53
    • /
    • 1998
  • Several performance measurement systems have been proposed and are currently being used in many organizations. However, no performance measurement system has presented a mechanism for integrating all of the information of performance measures in a way that considers the relationships between them. This paper proposes the performance information integration method (PIIM) which synthesizes all useful information of performance measures with consideration of the relationships and generates a single, global, organizational performance score. The PIIM showed good performance in the implementation in one long-term care facility. This paper provides performance measurement systems with an integration mechanism for multiple performance measures.

  • PDF