• 제목/요약/키워드: inelastic seismic demands

검색결과 64건 처리시간 0.025초

Near Field 지진의 특징과 구조응답에 대한 영향 (Characteristics of Near Field Earthquakes and its effect on Seismic demands)

  • 배미혜;권오성;한상환
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.208-213
    • /
    • 2002
  • Near field ground motions contain distinct, large amplitude pulses in both velocity and displacement. This paper presents an investigation on the characteristics of near filed earthquakes and their effects on seismic demands. For this purpose 20 sets of near field ground motion and 20 sets of far filed ground motion are compared with respect to Linear Elastic Response Spectrum(LERS), Response Modification Factor(R), Inelastic Response Spectrum(IRS), and performance point of Capacity Spectum Method(CSM).

  • PDF

수정 모드해석방법을 이용한 비대칭 벽식 구조물의 내진성능평가 (Seismic Assessment of Plan-irregular Wall Structures using Adaptive Modal Analysis)

  • 하태휴;홍성걸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.589-596
    • /
    • 2006
  • Torsional behavior of eccentric structures under seismic loading may cause stress and/or strain concentration, which result in the failure of the structures in an unexpected manner. This study propose how to assess the seismic capacity of plan-irregular RC wall structures. The seismic capacities ate expressed in terms of lateral displacement capacity of each wall. The seismic demands for displacement are assessed by so called displacement-based design approach. Those seismic capacity and demands are combined D-R coordinate, which is made up of lateral displacement and rotation angle. To expand these concepts to the inelastic region the adaptive modal analysis method is used. In addition, the failure mechanisms including torsional failure are defined on D-R coordinate. Finally, seismic assessments of two 3-story plan-irregular wall structures ate presented.

  • PDF

Moment resisting steel frames under repeated earthquakes

  • Loulelis, D.;Hatzigeorgiou, G.D.;Beskos, D.E.
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.231-248
    • /
    • 2012
  • In this study, a systematic investigation is carried out on the seismic behaviour of plane moment resisting steel frames (MRF) to repeated strong ground motions. Such a sequence of earthquakes results in a significant damage accumulation in a structure because any rehabilitation action between any two successive seismic motions cannot be practically materialised due to lack of time. In this work, thirty-six MRF which have been designed for seismic and vertical loads according to European codes are first subjected to five real seismic sequences which are recorded at the same station, in the same direction and in a short period of time, up to three days. Furthermore, the examined frames are also subjected to sixty artificial seismic sequences. This investigation shows that the sequences of ground motions have a significant effect on the response and, hence, on the design of MRF. Additionally, it is concluded that ductility demands, behaviour factor and seismic damage of the repeated ground motions can be satisfactorily estimated using appropriate combinations of the corresponding demands of single ground motions.

On the seismic response of steel buckling-restrained braced structures including soil-structure interaction

  • Flogeras, Antonios K.;Papagiannopoulos, George A.
    • Earthquakes and Structures
    • /
    • 제12권4호
    • /
    • pp.469-478
    • /
    • 2017
  • This paper summarizes estimated seismic response results from three-dimensional nonlinear inelastic time-history analyses of some steel buckling-restrained braced (BRB) structures taking into account soil-structure interaction (SSI). The response results involve mean values for peak interstorey drift ratios, peak interstorey residual drift ratios and peak floor accelerations. Moreover, mean seismic demands in terms of axial force and rotation in columns, of axial and shear forces and bending moment in BRB beams and of axial displacement in BRBs are also discussed. For comparison purposes, three separate configurations of the BRBs have been considered and the aforementioned seismic response and demands results have been obtained firstly by considering SSI effects and then by neglecting them. It is concluded that SSI, when considered, may lead to larger interstorey and residual interstorey drifts than when not. These drifts did not cause failure of columns and of the BRBs. However, the BRB beam may fail due to flexure.

Seismic structural demands and inelastic deformation ratios: a theoretical approach

  • Chikh, Benazouz;Mebarki, Ahmed;Laouami, Nacer;Leblouba, Moussa;Mehani, Youcef;Hadid, Mohamed;Kibboua, Abderrahmane;Benouar, Djilali
    • Earthquakes and Structures
    • /
    • 제12권4호
    • /
    • pp.397-407
    • /
    • 2017
  • To estimate the structural seismic demand, some methods are based on an equivalent linear system such as the Capacity Spectrum Method, the N2 method and the Equivalent Linearization method. Another category, widely investigated, is based on displacement correction such as the Displacement Coefficient Method and the Coefficient Method. Its basic concept consists in converting the elastic linear displacement of an equivalent Single Degree of Freedom system (SDOF) into a corresponding inelastic displacement. It relies on adequate modifying or reduction coefficient such as the inelastic deformation ratio which is usually developed for systems with known ductility factors ($C_{\mu}$) and ($C_R$) for known yield-strength reduction factor. The present paper proposes a rational approach which estimates this inelastic deformation ratio for SDOF bilinear systems by rigorous nonlinear analysis. It proposes a new inelastic deformation ratio which unifies and combines both $C_{\mu}$ and $C_R$ effects. It is defined by the ratio between the inelastic and elastic maximum lateral displacement demands. Three options are investigated in order to express the inelastic response spectra in terms of: ductility demand, yield strength reduction factor, and inelastic deformation ratio which depends on the period, the post-to-preyield stiffness ratio, the yield strength and the peak ground acceleration. This new inelastic deformation ratio ($C_{\eta}$) is describes the response spectra and is related to the capacity curve (pushover curve): normalized yield strength coefficient (${\eta}$), post-to-preyield stiffness ratio (${\alpha}$), natural period (T), peak ductility factor (${\mu}$), and the yield strength reduction factor ($R_y$). For illustrative purposes, instantaneous ductility demand and yield strength reduction factor for a SDOF system subject to various recorded motions (El-Centro 1940 (N/S), Boumerdes: Algeria 2003). The method accuracy is investigated and compared to classical formulations, for various hysteretic models and values of the normalized yield strength coefficient (${\eta}$), post-to-preyield stiffness ratio (${\alpha}$), and natural period (T). Though the ductility demand and yield strength reduction factor differ greatly for some given T and ${\eta}$ ranges, they remain take close when ${\eta}>1$, whereas they are equal to 1 for periods $T{\geq}1s$.

중층 종합병원 건물의 내진성능평가 (Seismic Performance Evaluation of a Mid-rise General Hospital Building)

  • 김태완;추유림;김승래
    • 한국지진공학회논문집
    • /
    • 제21권5호
    • /
    • pp.245-254
    • /
    • 2017
  • The building which are essential for disaster recovery is classified as a special seismic use group. Especially, achievement of seismic performance is very important for the hospital, so the hospital should be able to maintain its function during and right after an earthquake without significant damage on both structural and non-structural elements. Therefore, this study aimed at checking the seismic performance of a hospital building, but which was limited to structural elements. For the goal, a plan with a configuration of general hospitals in Korea was selected and designed by two different seismic-force-resisting systems. In analytical modeling, the shear behavior of the wall was represented by three inelastic properties as well as elastic. Nonlinear dynamic analyses were conducted to evaluate the performance of structural members. The result showed that the performance of shear walls in the hospital buildings was not satisfied regardless of the seismic-force-resisting systems, while the demands on the beams and columns did not exceed the capacities. This is the result of only considering the shear of the wall as the force-controlled action. When the shear of the wall was modeled as inelastic, the walls were yielded in shear, and as the result, the demands for frames were increased. However, the increase did not exceed the capacities of the frames members. Consequently, since the performance of walls is significant to determine the seismic performance of a hospital building, it will be essential to establish a definite method of modeling shear behavior of walls and judging their performance.

The effect of soil-structure interaction on inelastic displacement ratio of structures

  • Eser, Muberra;Aydemir, Cem
    • Structural Engineering and Mechanics
    • /
    • 제39권5호
    • /
    • pp.683-701
    • /
    • 2011
  • In this study, inelastic displacement ratios and ductility demands are investigated for SDOF systems with period range of 0.1-3.0 s. with elastoplastic behavior considering soil structure interaction. Earthquake motions recorded on different site conditions such as rock, stiff soil, soft soil and very soft soil are used in analyses. Soil structure interacting systems are modeled with effective period, effective damping and effective ductility values differing from fixed-base case. For inelastic time history analyses, Newmark method for step by step time integration was adapted in an in-house computer program. Results are compared with those calculated for fixed-base case. A new equation is proposed for inelastic displacement ratio of interacting system ($\tilde{C}_R$) as a function of structural period of interacting system ($\tilde{T}$), strength reduction factor (R) and period lengthening ratio ($\tilde{T}/T$). The proposed equation for $\tilde{C}_R$ which takes the soil-structure interaction into account should be useful in estimating the inelastic deformation of existing structures with known lateral strength.

건축구조물의 시스템 연성요구도 평가를 위한 대표응답의 활용 (Responses of Equivalent SDOF System for System Ductility Demands Evaluation of Multistory Building Structures)

  • 최원호;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.446-453
    • /
    • 2001
  • System-level ductility is an essential parameter for seismic performance evaluation of multistory building structures. The ductility demands for single degree of freedom structures or individual structural members can be determined easily. However, there is no clearly established method to determine the ductility demands for structural systems. The system ductility demands are estimated in this study by the equivalent SDOF system methods and proposed method which used the representative responses obtained from the MDOF systems directly. And seismic performance of building structures is evaluated by the modified Capacity Spectrum Method using the representative responses, and the result was compared with those of the inelastic time history analysis.

  • PDF

철근 콘크리트 특수 모멘트 골조 건물의 비탄성 동적 요구값 (Inelastic Dynamic Demands of a RC Special Moment Frame Building)

  • 김태완
    • 한국지진공학회논문집
    • /
    • 제9권5호
    • /
    • pp.11-19
    • /
    • 2005
  • 건축 구조물의 내진 설계는 탄성 정적 방법에 기초하고 있으나, 강진시 구조물의 실제 거동은 비탄성 동적이기 때문에 설계 규준의 적합성을 판단하기 위해서는 비탄성 동적 해석이 요구된다. 본 논문에서는 철근 콘크리트 특수 모멘트 저항 골조 건물을 선택하여 IBC 2003에 따라 설계한 후, 선택된 부재들의 최대 소성 회전, 소산 에너지를 구하여, 건물의 비탄성 거동이 규준에서 의도한 거동을 보이는 지를 검토함과 동시에 층간변위률 요구값을 구하여 설계 한도를 만족하는 지를 조사하였다. 더불어 비횡력 저항 시스템인 내부 모멘트 저항 골조의 해석시 포함 여부의 영향도 함께 조사하였다. 해석 결과 IBC 2003에 의해 설계된 건물은 규준이 의도한 비탄성 거동을 보여주었으며 층간변위률 또한 설계한도를 만족하였다. 그리고, 내부 모멘트 저항 골조는 지진 해석 결과에 중요한 영향을 미치므로 해석 모델에 반드시 포함되어야 함을 알수 있었다.

Influence of incident angles of earthquakes on inelastic responses of asymmetric-plan structures

  • Nguyen, Van Tu;Kim, Dookie
    • Structural Engineering and Mechanics
    • /
    • 제45권3호
    • /
    • pp.373-389
    • /
    • 2013
  • This paper presents the influence of incident angles of earthquakes on inelastic dynamic responses of asymmetry single story buildings under seismic ground motions. The dynamic responses such as internal forces and rotational ductility factor are used to evaluate the importance of the incident angles of ground motions in the inelastic range of structural behavior. The base shear and torque (BST) response histories of the resisting elements and of the building are used to prove that the shape of the BST surface of the building can be a practical tool to represent those of all resisting elements. This paper also shows that the different global forces which produce the maximum demands in the resisting elements tend to converge toward a single distribution in a definable intensity range, and this single distribution is related to the resistance distribution of the building.