• 제목/요약/키워드: inelastic earthquake response

검색결과 188건 처리시간 0.022초

An assessment of code designed, torsionally stiff, asymmetric steel buildings under strong earthquake excitations

  • Kyrkos, M.T.;Anagnostopoulos, S.A.
    • Earthquakes and Structures
    • /
    • 제2권2호
    • /
    • pp.109-126
    • /
    • 2011
  • The inelastic earthquake response of non-symmetric, braced steel buildings, designed according to the EC3 (steel structures) and EC8 (earthquake resistant design) codes, is investigated using 1, 3 and 5-story models, subjected to a set of 10, two-component, semi-artificial motions, generated to match the design spectrum. It is found that in these buildings, the so-called "flexible" edge frames exhibit higher ductility demands and interstory drifts than the "stiff" edge frames. We note that the same results were reported in an earlier study for reinforced concrete buildings and are the opposite of what was predicted in several other studies based on the over simplified, hence very popular, one-story, shear-beam type models. The substantial differences in such demands between the two sides suggest a need for reassessment of the pertinent code provisions. In a follow up paper, a design modification will be introduced that can lead to a more uniform distribution of ductility demands in the elements of all building edges. This investigation is another step towards more rational design of non-symmetric steel buildings.

최대 비탄성 변위 응답 예측을 위한 기존 능력스펙트럼법들의 유효성 평가 및 비교 (Evaluation of Capacity Spectrum Methods for Estimating the Peak Inelastic Responses)

  • 김홍진;민경원;이상현;박민규
    • 한국지진공학회논문집
    • /
    • 제8권2호
    • /
    • pp.35-44
    • /
    • 2004
  • 탄성응답스펙트럼을 사용하는 능력스펙트럼법은 비선형 시스템을 등가의 선형시스템으로 치환하여 주어진 지진 하중에 대한 구조물의 최대 비선형 거동을 예측한다. 본 연구의 목적은 이러한 능력스펙트럼법들의 정확성을 검증하고, 예측 특성을 비교하는 것이다. 이를 위해, ATC-40, G lkan, Kowalsky, 그리고 Iwan이 제시한 방법을 이용하여 등가주기와 등가감쇠비를 산정한 후, ATC-40에서 제시한 절차B에 따라 성능점을 산정 하였다. 전반적으로 ATC-40 방범은 구조물의 응답을 과소 평가하여 안전하지 못한 설계결과를 가져 올 수 있으며, G lkan과 Kowalsky의 방법은 과대 평가하는 경향을 가지고 있다. Iwan이 제시한 방법은 ATC-40 방법과 G lkan과 Kowalsky 방법의 중간 값을 예측함으로써, 비교적 정확한 값에 가까운 최대 변위를 산출하였다. 그리고, Kowalsky 방법은 항복 후 강성비에 따라 등가감쇠비를 음수로 산정함으로써 예측 값을 제시하지 못하는 경우가 있음을 확인하였다.

비탄성 설계 스펙트럼에 의한 이력 모델의 효과 (Effect of Hysteretic Models on the Inelastic Design Spectra)

  • 한상환;오영훈;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.214-224
    • /
    • 1999
  • The design response spectrum has been widely used in seismic design to estimate force and deformation demands of structures imposed by Earthquake Ground Motion (EQGM). Inelastic Design Response Spectra (IDRS) to specify design yielding strength in seismic codes are obtained by reducing the ordinates of Linear Elastic Design Response Spectrum (LEDRS) by strength reduction factor (R). Since a building is designed using reduced design spectrum (IDRS) rather than LEDRS in current seismic design procedures it allows structures behave inelastically during design level EQGM. Inelastic Response Spectra (IRS) depend not only on the characteristics of the expected ground motion at a given site, but also on the dynamic properties and nonlinear characteristics of a structure. However, it has not been explicitly investigated the effect of different hysteretic models on IRS. In this study, the effect of hysteretic models on IRS is investigated.

  • PDF

기기의 지진취약도 평가를 위한 구조물 비탄성구조응답계수의 재평가 (Revaluation of Inelastic Structural Response Factor for Seismic Fragility Evaluation of Equipment)

  • 박준희;최인길
    • 한국전산구조공학회논문집
    • /
    • 제28권3호
    • /
    • pp.241-248
    • /
    • 2015
  • 원자력발전소에는 전력생산과 안전과 관련된 수많은 기기들이 존재하고 있다. 기본적으로 원자력발전소의 구조물과 기기는 지진시 탄성거동올 목표로 안전율을 매우 높게 적용하여 설계해 왔다. 그러나 최근 발생한 지진의 규모가 증가함에 따라 설계수준을 초과한 지진에 대한 기기의 안전성을 재평가할 필요가 있다. 본 연구에서는 구조물의 비선형 거동에 의한 층응답을 분석하였고, 비선형해석에 의한 구조물의 비탄성구조응답계수를 재평가하였다. 기기의 지진취약도 평가시 구조물의 비탄성구조응답이 어떤 영향을 주는지 분석하기 위하여 재평가된 구조물의 비탄성구조응답계수와 기존에 사용되어온 구조물 비탄성구조응답계수를 적용하여 지진취약도 평가를 수행하였다. 해석결과에 따르면 비탄성구조응답계수는 기기의 고유진동수, 기기의 위치 그리고 구조물의 동특성에 따라 영향을 받는 것으로 나타났다.

The M6.4 Lefkada 2003, Greece, earthquake: dynamic response of a 3-storey R/C structure on soft soil

  • Giarlelis, Christos;Lekka, Despina;Mylonakis, George;Karabalis, Dimitris L.
    • Earthquakes and Structures
    • /
    • 제2권3호
    • /
    • pp.257-277
    • /
    • 2011
  • An evaluation is presented of the response of a 3-storey R/C structure during the destructive Lefkada earthquake of 14/08/2003. Key aspects of the event include: (1) the unusually strong levels of ground motion (PGA = 0.48 g, $SA_{max}$ = 2.2 g) recorded approximately 10 km from fault, in downtown Lefkada; (2) the surprisingly low structural damage in the area; (3) the very soft soil conditions ($V_{s,max}$ = 150 m/s). Structural, geotechnical and seismological aspects of the earthquake are discussed. The study focuses on a 3-storey building, an elongated structure of rectangular plan supported on strip footings, that suffered severe column damage in the longitudinal direction, yet minor damage in the transverse one. Detailed spectral and time-history analyses highlight the interplay of soil, foundation and superstructure in modifying seismic demand in the two orthogonal directions of the building. It is shown that soil-structure interaction may affect inelastic seismic response and alter the dynamic behavior even for relatively flexible systems such as the structure at hand.

고진동수 지진에 대한 기기 정착부의 비탄성 거동을 고려한 지진취약도 평가 (Seismic Fragility Analysis Considering the Inelastic Behavior of Equipment Anchorages for High-Frequency Earthquakes)

  • 임승현;곽신영;최인길;정재욱;김석철
    • 한국지진공학회논문집
    • /
    • 제25권6호
    • /
    • pp.261-266
    • /
    • 2021
  • Nuclear power plants in Korea were designed and evaluated based on the NRC's Regulatory Guide 1.60, a design response spectrum for nuclear power plants. However, it can be seen that the seismic motion characteristics are different when analyzing the Gyeongju earthquake and the Pohang earthquake that has recently occurred in Korea. Compared to the design response spectrum, seismic motion characteristics in Korea have a larger spectral acceleration in the high-frequency region. Therefore, in the case of equipment with a high natural frequency installed in a nuclear power plant, seismic performance may be reduced by reflecting the characteristics of domestic seismic motions. The failure modes of the equipment are typically structural failure and functional failure, with an anchorage failure being a representative type of structural failure. In this study, comparative analyses were performed to decide whether to consider the inelastic behavior of the anchorage or not. As a result, it was confirmed that the seismic performance of the anchorages could be increased by considering the inelastic behavior of an anchorage.

고층건물 내진설계기법의 개선 (IMPROVED EARTHQUAKE RESISTANT DESIGN OF MULTISTORY BUILDING FRAMES)

  • Lee, Dong-Guen-;Lee, Seok-Youn-
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1991년도 봄 학술발표회 논문집
    • /
    • pp.72-78
    • /
    • 1991
  • An improved procedure for earthquake resistant design of multistory building structures is proposed in this study. The effect of gravity load on seismic response of structures is evaluated through nonlinear dynamic analyses of a single story example structure. The presence of gravity load tends to initiate plastic hinge formation in earlier stage of a strong earthquake. However, the effect of gravity load seems to disapper as ground motion is getting stronger. And one of shortcomings in current earthquake resistant codes is overestimation of gravity load effects when earthquake load is applied at the same time so that it may leads to less inelastic deformation or structural damage in upper stories, and inelastic deformation is increased in lower stories. Based on these observation, an improved procedure for earthquake resistant design is derived by reducing the factor for gravity load and inceasing that for seismic load. Structures designed by the proposed design procedure turned out to have increased safety and stability against strong earthquakes.

  • PDF

요구스펙트럼의 비탄성이력특성 -완전탄소성모델을 중심으로- (Inelastic Hysteretic Characteristics of Demand Spectrum -Focused on Elasto Perfectly Plastic Model-)

  • 이현호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.367-374
    • /
    • 2000
  • This study investigates the effect of hysteretic characteristics to the Inelastic Demand Spectrum (IDS) which was expressed by an acceleration(Sa) and a displacement response spectrum (Sd). Elasto Perfectly Plastic(EPP) model is used in this study and inelastic demand spectrum (Sa vs, Sd) are obtained from a given target ductility ratio. For a given target ductility ratio IDS can be obtained by using nonlinear time history analysis of single degree of system with forth five recorded earthquake ground motions for stiff soil site. The effect EPP model under demand spectrum is investigated by ductility factor and natural frequency. According to the results obtained in this study IDS has dependency on ductility factor and natural frequency.

  • PDF

경주지진과 유사한 특성을 가지는 지반가속도로 가진된 단주기 구조물 변위연성도 평가 (Ductility Demand for Short-period Structures Excited by Ground Accelerations Similar to Gyeong-ju Earthquakes)

  • 노지은;이상현;서준원;김동관
    • 한국지진공학회논문집
    • /
    • 제20권7_spc호
    • /
    • pp.495-502
    • /
    • 2016
  • In this paper, time and frequency domain characteristics of Gyeong-ju earthquakes were investigated, and nonlinear time history analyses were conducted for bi-linear hysteretic structures excited by short-duration ground accelerations. Previous studies showed that larger inelastic displacements than the peak displacement of the corresponding elastic system were observed especially for the structures with structural period shorter than 0.3s, and the similar results could be obtained when long-duration ground accelerations were used as excitation loads. For the short-duration earthquakes, however, the inelastic displacements were not so large and almost identical to the peak elastic displacements.

모멘트-연성 강구조물의 내진설계를 위한 반응수정계수의 평가 (Evaluation of Response Modification Factore for Earthquake Resistant Design of Moment-Resisting Steel Frames)

  • 송종걸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.201-208
    • /
    • 1997
  • In most seismic codes such as the Uniform Building Code(UBC), the response modification factor(or the force reduction factor)is used to reflect the capability of a structure in dissipating energy through inelastic behavior. The response modification factor is assigned according to structural system type. Ductile systems such as special moment-resisting steel frames are assigned larger values of the response modification factor, and are consequently designed for smaller seismic design forces. Therefore, structural damage may occur during a severe earthquake. To ensure safety of the structures, the suitability of the response modification factor used in aseismic design procedures shall be evaluated. The object of this study is to develop a method for the evaluating of the response modification factor. The validity of the evaluating method has been examined for several cases of different structures and different earthquake excitations.

  • PDF