• 제목/요약/키워드: industrial waste incinerator

검색결과 52건 처리시간 0.023초

국내 일부 소각장 근로자와 주변지역주민들의 PCDDs/Fs 노출과 건강 영향 평가 (Exposure Assessment of PCDD/Fs and Monitoring of Health Effects on Workers and Resident near the Waste Incinerators in Korea)

  • 홍윤철;이관희;권호장;장재연;임종한
    • Journal of Preventive Medicine and Public Health
    • /
    • 제36권4호
    • /
    • pp.314-322
    • /
    • 2003
  • Objectives : In this study, the exposure status of the hazardous substances from incinerators, such as polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), were studied , and the relationship between the exposure of these hazardous substances and their heath effects on the workers and residents near municipal solid waste (MSW) incinerators and an industrial incinerator investigated. Methods : Between July 2001 and Jure 2002, 13 workers at two MSW incinerators, 16 residents from the area around the two MSW incinerators, 6 residents from the control area, and further 10 residents near an industrial incinerator, estimated to emit higher levels of hazardous substances, were interviewed. Information, including sociodemographic information, personal habits, and work history, detailed gynecologic and other medical history were collected through interviews. Blood samples were also collected from 45 subjects, and analyzed for PCDD/DFs, by high resolution gas chromatography -high resolution mass spectrometry, using the US EPA 1613 method. In addition to the questionnaire survey, urinary concentrations of 8-hydroxydeoxyguanosine (8-OH-dG) and malondialdehyde (MDA) were measured as oxidative injury biomarkers. The urinary concentrations of 8-OH-dG were determined by in vitro ELISA, and the MDA by HPLC, using u adduct with thiobarbituric acid. Results : The PCDD/DFs concentrations in the residents near the industrial incinerator were higher than those in the controls, workers and residents near the MSW incinerators. The average TEQ (Toxic Equivalencies) concentrations of the PCDD/DFs in residents near the industrial incinerator were 53.4pg I-TEQs/g lipid. The estimated daily intakes were within the tolerable daily intake range (1-4 pg I-TEQ/Kg bw/day) suggested by WHO (1997) in only 30% to the people near the industrial incinerator. Animal studies have already shown that even a low body border of PCDD/DFs, such as 10 ng TEQ/kg bw, can cause oxidative damage in laboratory animals. Our study also showed that the same body burden of PCDD/DFs can cause oxidative damage to humans. Conclusions : The exposures to PCDD/DFs and the oxidative stress of residents near the industrial incinerator, were higher than those in the controls, workers and residents near the MSW incinerators. Proper protection strategies against these hazardous chemicals are needed. Because a lower body burden of PCDD/Fs, such as 10ng TEQ/kg bw, can cause oxidative damage, the tolerable daily intake range should be restrictedly limited to 1pg I-TEQ/kg bw/day.

폐기물 소각시설 배가스에서의 수은 배출특성 (The Characteristics of Mercury Emission from Municipal Solid Waste (MSW) Incinerator Stack)

  • 이한국
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.378-387
    • /
    • 2004
  • This study was carried to investigate the emission characteristics of mercury from domestic and industrial MSW (municipal solid waste) incinerator stacks. The mercury concentration levels of flue gas from 32 MSW incinerators stacks selected were above the criteria level ($5{\mu}g/S\;m^3$). MSWI facilities exceeding the criteria levels in Korea are due to the poor units comparison of combustion chamber(CC)-cyclone(CY)-stack. So, the mercury from MSW incinerators stack were suspected to contaminate the natural system unless the MSW incinerators were properly controlled. Mean-while, the relationship between mercury concentration and temperature of flue gas in MSW incinerator stacks were examined at two temperature ranges (Group A : $29.85{\sim}327.63^{\circ}C$, Group B : $446.9{\sim}848.15^{\circ}C$). The mercury concentration in flue gas with high temperature range was higher than that of flue gas with low temperature rage. This mean that the temperature of flue gas plays an important role in mercury control in MSW incinerator. The emission characteristics oi mercury was also evaluated by using the correlation matrix between the mercury and NOx, $PM_{10}$, moisture (MO.) at both low temperature and high temperature flue gas ranges. The mercury concentration was mainly affected by NOx, $PM_{10}$. moisture (MO.) at low temperature range, while the mercury concentration at high temperature flue gas was mainly affected by NOx, moisture (MO.). From these results, it was suggested that the temperature of cooling system and the air pollution control device should be properly regulated in order to control mercury of flue gas in MSWI incinerator.

가속탄산화를 통한 Ca-rich Waste Mineral의 정량적인 CO2 고용량 평가 (Quantitative Evaluation of CO2 Sequestration in Ca-rich Waste Mineral for Accelerated Carbonation)

  • 남성영;엄남일;안지환
    • 한국세라믹학회지
    • /
    • 제51권2호
    • /
    • pp.64-71
    • /
    • 2014
  • Accelerated carbonation is a technique that can be used as a CCS technology for $CO_2$ sequestration of approximately 5~20% in a stable solid through the precipitation of carbonate. An alkaline inorganic waste material such as ash, slag, and cement paste are generated from incinerators, accelerated carbonation offers the advantage of lower transport and processing costs at the same generation location of waste and $CO_2$. In this study, we evaluated an amount of $CO_2$ sequestration in various types of inorganic alkaline waste processed by means of accelerated carbonation. A quantitative evaluation of $CO_2$ real sequestration based on a TG/DTA analysis, the maximum 118.88 $g/kg_{-waste}$ of $CO_2$ in paper sludge fly ash, the maximum 134.46 $g/kg_{-waste}$ of $CO_2$ in municipal solid waste incinerator bottom ash, the maximum 9.72 $g/kg_{-waste}$ of $CO_2$ in industrial solid waste incinerator fly ash, and the maximum $18.19g/kg_{-waste}$ of $CO_2$ in waste cement paste.

산업쓰레기 소각재를 이용한 인공골재의 품질특성 (The Quality Characteristics of Artificial Aggregates Using Bottom ash from Industrial Waste Incinerator)

  • 김재신;고대형;문경주;백명종;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.257-262
    • /
    • 2000
  • The purpose of this study is grasping quality aggregate using Bottom Ash of Industrial Waste Incinerator, and is evaluating possibility of application as construction materials. Cement and Fly ash is used with binder of aggregates using bottom ash. It is tested for basic property and strength of artificial aggregates, and the results are compared with crushed stone and elution tests is done for environmental safety. In the results of tests, it is confirmed that basic property and strength are lowe than crushed stone but the aggregates have possibility of application as artificial lightweight aggregates. When it is manufactured with aggregates, it is sage environmentally because of protecting elution of harmful heavy metals.

  • PDF

소나무 잎을 이용한 대기 중 다이옥신/퓨란 발생원 추정 (Source Tracking of PCDD/Fs in Ambient Air Using Pine Needles)

  • 천만영;김정수;고도현
    • 한국환경보건학회지
    • /
    • 제41권1호
    • /
    • pp.49-60
    • /
    • 2015
  • Objectives: Pine needles were used as a passive air sampler (PAS) of atmospheric persistent organic pollutants (POPs). This study was performed to investigate concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) deposited on pine needles near a waste incinerator and PCDD/Fs source contributions using principal component analysis (PCA). Methods: Two-year-old pine needles were sampled at 11 points with respect to distance and wind direction from the incinerator. PCDD/Fs deposited on pine needles were analyzed with HRGC/HRMS. The source contribution of PCA was calculated with SPSS. Results: The average concentration of PCDD/Fs deposited on pine needle was 0.79 (0.27-1.76) pg TEQ/g dry, PCDDs with 0.24 (0.01-0.95) pg TEQ/g dry and PCDFs with 0.56 (0.27-0.82) pg TEQ/g dry, respectively. The average concentration fraction of PCDDs was 29.7%, that of PCDFs was 70.3%, and PCDFs were more prevalent than PCDDs. The contributions of PCDD/Fs sources were estimated as incineration at 58.3% and automobiles at 28.4%. However, a relation and regulation between PCDD/Fs concentrations deposited on pine needles and distance from incinerator or wind direction was not shown. Conclusion: It was concluded that atmospheric PCDD/Fs concentrations near an industrial complex with a waste incinerator were affected by multiple sources. However, PCDD/Fs concentrations were lower than in other inland cities with the exception of background area.

SO$_2$ and NOx Reaction Characteristics of Waste Clam Sorbent in Fixed Bed Reactor

  • Jung, Jong-Hyeon;Shon, Byung-Hyun;Yoo, Kyung-Sun;Kim, Hyun-Gyu;Lee, Gang-Woo;Kim, Young-Sik
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2003년도 Challenges and Achievements in Environmental Health
    • /
    • pp.152-156
    • /
    • 2003
  • Air pollution problems due to the emission of pollutants from the various industrial facilities become serious issues and lots of air pollution control processes have been developed. To remove the SO$_2$ and NOx emitted from the solid waste incinerator and coal fired power plants, we studied the Ca-based sorbent which was prepared by waste clam and limestone. The objectives of this study were to develop a clam-based sorbent for removal of SO$_2$ and NOx, and to investigate the physicochemical properties of the waste clam sorbent. In order to determine acid gas removal capacity of sorbent, the batch study on SO$_2$ and NOx removal was performed with the Ca-based sorbent in the fixed bed reactor. Results of the research revealed that clam-based sorbent can be used as the iron-manufacturing industry and chemical adsorbents for the removal of acid gases because the lime content of the waste calm was more than 53.92%. From physicochemical analysis and gas reaction experiments, it could be concluded that clam is good sorbent for the removal of SO$_2$ and NOx in waste incinerator and flue gas desulfurization processes.

  • PDF

로타리킬른 소각로를 이용한 하수슬러지와 사업장폐기물의 혼합소각 특성 (Co-incineration Characteristics of Sewage Sludge and Industrial Waste Using the Rotary Kiln Incinerator)

  • 양동집;고재철;김정근;박희재;박준석
    • 유기물자원화
    • /
    • 제17권3호
    • /
    • pp.91-99
    • /
    • 2009
  • 본 연구에서는 하수슬러지와 사업장폐기물의 혼합소각을 위한 폐기물특성 및 운전특성을 살펴보고 향후 하수슬러지와 사업장폐기물의 혼합소각에 관한 기초자료를 제시하고자 하였다. 본 사업장폐기물은 플라스틱류가 42.55% 로 종이류(11.92%) 보다 3배 이상의 조성을 나타내었다. 하수슬러지와 사업장폐기물을 부피비로 3 : 7로 혼합한 폐기물의 삼성분은 수분함량이 16.3%, 가연분과 회분 함량은 각각 70.5%와 13.2%을 나타내었으며, 습윤저위발열량도 4,513kcal/kg으로 함수율 15%인 하수슬러지와 사업장폐기물(플라스틱류 약 43% 및 종이류 약 12% 함유)의 3 : 7 혼합소각이 가능할 것으로 예상된다. 혼합폐기물을 $700^{\circ}C$로 소각할 경우 SOx와 NOx 농도는 최소화할 수 있었으 나 다이옥신 등 유해가스 발생면에서 볼 때 $950^{\circ}C$로 소각하는 것이 더 바람직할 것으로 사료되며, 이를 위해서는 $Ca(OH)_2$의 적정사용이 검토되어야 할 것으로 판단된다.

Demonstration of a Modular Electrostatic Precipitator to Control Particulate Emissions from a Small Municipal Waste Incinerator

  • Intra, Panich;Yawootti, Artit;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.239-246
    • /
    • 2014
  • Incineration is conceptually sound as a waste treatment technology. There is, however, concern over its emissions when it is improperly designed and operated. An electrostatic precipitator is one of the most commonly used devices to control particulate emissions from boilers, incinerators and some other industrial processes. In this work, a modular electrostatic precipitator with sizing of $1m{\times}1m{\times}1m$ was developed for removal of particulate matter from the exhaust gases of a small waste incinerator. Its design was based on a simple wire-and-plate concept. The corona discharge wires were connected to a positive high-voltage pulse generator, while the collection plates were grounded. The high-voltage pulse generator was used to produce the corona discharge field between the individual discharge wire and the collection plate. The particulate-laden exhaust gas flow was directed across the corona discharge field. The charged particles were deflected outward and collected on the plate. The collection efficiency was evaluated as a mass loading ratio between the difference at the inlet and the outlet to the particulate loading at the inlet of the precipitator. The collection efficiency of this modular electrostatic precipitator design was approximately 80 %.

Research Investigations at the Municipal (2×35) and Clinical (2×5 MW) Waste Incinerators in Sheffield, UK

  • Swithenbank, J.;Nasserzadeh, V.;Ewan, B.C.R.;Delay, I.;Lawrence, D.;Jones, B.
    • 청정기술
    • /
    • 제2권2호
    • /
    • pp.100-125
    • /
    • 1996
  • After recycle of spent materials has been optimised, there remains a proportion of waste which must be dealt with in the most environmentally friendly manner available. For materials such as municipal waste, clinical waste, toxic waste and special wastes such as tyres, incineration is often the most appropriate technology. The study of incineration must take a process system approach covering the following aspects: ${\bullet}$ Collection and blending of waste, ${\bullet}$ The two stage combustion process, ${\bullet}$ Quenching, scrubbing and polishing of the flue gases, ${\bullet}$ Dispersion of the flue gases and disposal of any solid or liquid effluent. The design of furnaces for the burning of a bed of material is being hampered by lack of an accurate mathematical model of the process and some semi-empirical correlations have to be used at present. The prediction of the incinerator gas phase flow is in a more advanced stage of development using computational fluid dynamics (CFD) analysis, although further validation data is still required. Unfortunately, it is not possible to scale down many aspects of waste incineration and tests on full scale incinerators are essencial. Thanks to a close relationship between SUWIC and Sheffield Heat&Power Ltd., an extended research programme has been carried out ar the Bernard Road Incinerator plant in Sheffield. This plant consists of two Municipal(35 MW) and two Clinical (5MW) Waste Incinerators which provide district heating for a large part of city. The heat is distributed as hot water to commercial, domestic ( >5000 dwelling) and industrial buildings through 30km of 14" pipes plus a smaller pipe distribution system. To improve the economics, a 6 MW generator is now being added to the system.

  • PDF

생활폐기물 성상변화에 따른 소각시설 바닥재의 특성 변화와 시멘트 클링커 원료로 재활용 가능성 평가 (Investigation of Characteristics of Incinerator Bottom Ash and Assessment for Recycle due to the Change of MSW Composition)

  • 이우찬;신득철;동종인
    • 공업화학
    • /
    • 제25권1호
    • /
    • pp.103-106
    • /
    • 2014
  • 생활폐기물 소각시설에서 발생하는 바닥재는 높은 염소함량과 불순물 때문에 재활용에 한계가 있다. 하지만 종량제봉투의 도입과 음식물폐기물의 직매립 금지, 생산자책임제도의 도입 등 다양한 제도의 개선을 통해 성상이 변화되고 있다. 최근의 생활폐기물은 수분함량과 염소함량이 낮고 발열량이 높은 특성을 보이는데 이는 음식물폐기물의 분리배출, 폐기물의 전처리를 통한 불연물의 분리, 염소 등이 함유된 PVC 분리 등에 기인한 것으로 볼 수 있다. 본 연구의 목적은 이러한 제도, 특히 음식물폐기물의 분리배출 등의 정책 도입에 따른 생활폐기물 소각시설의 바닥재 성상변화 특성을 분석하고 이를 토대로 바닥재의 재활용 가능성을 평가하는 것이다. 바닥재에 함유된 다양한 성분 중 시멘트 클링커의 주요 성분인 CaO는 2001년 26.7%에서 2006년 34.0%로 증가하였고, 염소성분은 2001년 1.84%에서 2006년 0.00655%로 큰 폭으로 감소하였는데 이는 석탄 화력발전소에서 발생하는 비산재의 특성에 근접하는 것으로서 시멘트 클링커의 원료물질 등 재활용 가능성을 가지게 된 것으로 판단할 수 있다.