• Title/Summary/Keyword: industrial sludge

Search Result 444, Processing Time 0.023 seconds

Coupling Equation of Specific Resistance to Filtration(SRF) and Capillary Suction Time(CST) of Digested Sewage Sludge (소화슬러지의 비저항계수(SRF)와 모세관흡입시간(CST)의 상호관계식 유도 및 비교)

  • Khim, Jee-Hyeong;Na, Seung-Min;Park, Ji-Ho;Kim, Young-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.874-880
    • /
    • 2007
  • Capillary Suction Time(CST) and Specific Resistance to Filtration(SRF) were commonly used to evaluate the sludge dewatering behaviors. A coupled equation was developed through the mathematical theory which represented both CST and SRF as the physical filterability of the ultrasonically treated sludge. The model for coupling CST and SRF includes both equipment variables and variables related to sludge characteristics, and verified with the results from experiments. The results of the theoretical and experimental study showed that a good correlation relationship among dewaterability indices.

  • PDF

Solidification/Stabilization of Dyeing Sludge Treated by Fenton Reagent Using Blast Furnace Slag and Fly Ash

  • Lee, Sookoo;Kim, Sebum
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.453-458
    • /
    • 2001
  • This study was performed to reuse the dyeing wastewater sludge treated by Fenton process through the solidification/stabilization technique. To solidify the dyeing sludge the industrial by-products such as blast furnace slag, fly ash and waste sand with cement were used. The laboratory scale and pilot scale test were conducted at room temperature to make construction brick which has high compressive strength and low leaching of heavy metals. The experimental results showed that blast furnace slag and fly ash could be used instead of cement and the products satisfied the regulation of Korean Standards. The blast furnace slag increased the compressive strength and the optimum ratio of slag/dyeing sludge on dry basis was found 0.4. The solidifying agent of SB series could increase rapidly the compressive strength and the optimum ratio of solidifying agent/sludge on dry basis was 0.26 at which the strength was two times compared with non-added condition. The portion of waste and industrial by-products in matrix was over 80%. From the pilot test the optimum pressure in molding was 100kg/$\textrm{cm}^2$ at which the compressive strength was over 100kg/$\textrm{cm}^2$. And the strength increased continuously to 160kg/$\textrm{cm}^2$ until 120 days curing time due to pozzolanic reaction. When SB-20 as a solidifying agent was used, the unconfined compressive strength of dyeing sludge could be obtained 110kg/$\textrm{cm}^2$ which satisfied the regulation of cement brick in Korea Standard(KS).

  • PDF

Analysis of Octylphenol, Nonylphenol, Di-octylphthalate in Sewage Sludge by GC/MS-SIM (GC/MS-SIM에 의한 하수 슬러지중에 포함된 Octylphenol, Nonylphenol, Di-octylphthalate의 정량)

  • Kim, Jong-Hun
    • Analytical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.248-255
    • /
    • 1999
  • Sewage sludge samples were extracted with dichlomethane by Soxhlet extraction. The extracts were analysed for the endocrine disrupting compounds (EDC), octylphenol(OP), nonylphenol (NP) and bis (2-ethylhexyl)phthalate (DOP) using GC/MS-SIM. In industrial sewage sludge (sample Z-1) the concentration of NP and DOP were respectively $1168{\mu}g/g$ and $1172{\mu}g/g$ whereas in domestic sludge (sample Z-2) the concentration were respectively $10.8{\mu}g/g$ and $80{\mu}g/g$. OP was not detected in Z-2, but detected a small amount in Z-2 of the samples. Environmental EDC have been shown to affect the fertility of range of living organisms, including humans, and the high levels of NP and DOP in industrial sewage sludge could have serious implications for the reproductive health of humans particularly if the compounds entered the human food chain through water or the ingestion of vegetables or animal products.

  • PDF

Mechanical Properties of Non-cement Matrix Utilizing the Circulating Fluidized Bed Combustion Boiler Fly Ash and Dyeing Sludge Carbide (염색슬러지 탄화물과 순환 유동층 연소 보일러 플라이애시를 활용한 무시멘트 경화체의 역학적 특성)

  • Kim, Tae-Hyun;Lee, Seung-Ho;Lee, Yong;Shin, Jin-Hyun;Lee, Sang-Soo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.425-430
    • /
    • 2016
  • Both rapid industrial development and society has achieved more comfortable life. But, behind this facts of this industrial development have current pictures that occur global warming and much more by-products by environmental pollution. Therefore, this study used BFS and CFA as by-products to reduce cement usage emitted at a high rate of $CO_2$ gas, to examine sludge recycling strategy more than 200,000ton emitted at local dyeing complex, we suggest basic data research about non-cement matrix properties of utilizing dyeing sludge carbide. As a result, the more dyeing sludge carbide replacement ratio gets higher, the more air content and flow rise. Also, as the dyeing sludge carbide replacement ratio increase more, flexural strength and compressive strength go down.

Study on solubilization of sewage sludge using electrolysis techniques (전기분해에 의한 하수슬러지 가용 효과 연구)

  • Lee, Ji-Sun;Chang, In-Soung;Lee, Chul-Ku;Joung, Seun-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.979-984
    • /
    • 2011
  • Although sludge production has been increased due to the number of the wastewater treatment plants expanded, needs of the techniques for the sludge reduction and disposal has been issued importantly because the sludge dumping to ocean is prohibited from 2012 by the London Dumping Convention. Therefore, the sludge solubilization using electrolysis as an alternative techniques for the sludge disposal was carried out in this study. Iridium coated titanium based insoluble electrodes were used and 20 volt was applied to the electrolysis reactor using DC power supply. Supernatants of the treated sludge was monitored: The soluble COD, TN, TP of it was increased to 151%, 22% and 6% respectively. And the sludge floc size distribution was changed, that is, the flocs ranged from 0.1 to 1.0 ${\mu}m$ were increased. All of these results indicate that the cells were lysed and the internal matters bursted out of the cell after electrolysis. As well as the reduction of the sludge production, the soluble organic matters from the cells could be used as an external carbon sources in the advanced wastewater treatment plants.

The Present Status of Standard Sludge Characterization Method (슬러지 성상평가방법의 표준화 현황)

  • Kim, Tak-Hyun;Park, Chul-Hwan;Kim, Sang-Yong
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.87-98
    • /
    • 2007
  • As the interest in environmental problems increased, the guideline of effluent qualities becomes strict and the amount of sludge produced from the wastewater treatment facilities steeply increased. The revised Korean acts prohibit the direct reclamation of the sludge exhausted in sewage treatment works from 2003, and the ocean dump of sludge will be also prohibited from 2012. Therefore, the sludge must be recycled, incinerated or composted. To properly perform the utilization and disposal operations, the establishment of well-defined procedures for the characterization of sludge by physical, chemical and biological method and setting up of guidelines for different treatment and disposal routes has become necessary. However, there have not been such standardized methods for sludge characterization in Korea. This review analyzes the present status of establishment and problems of sludge characterization method of Korea. Finally, it was proposed total 15 items of standardized characterization methods suitable to our country for proper sludge recycling and disposal, which was based on the more systematic standard methods of Germany (DIN 38414) and those of advanced nations.

  • PDF

Co-incineration Characteristics of Sewage Sludge and Industrial Waste Using the Rotary Kiln Incinerator (로타리킬른 소각로를 이용한 하수슬러지와 사업장폐기물의 혼합소각 특성)

  • Yang, Dong-Jib;Ko, Jae-Cheol;Kim, Jeong-Keun;Park, Hui-Jae;Park, Joon-Seok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.3
    • /
    • pp.91-99
    • /
    • 2009
  • This research were performed to evaluate co-incineration characteristics of sewage sludge and industrial waste in rotary kiln incinerator, and provide the fundamental data. Plastic portion (42.55%) in this industrial waste showed over 3 times higher than that (11.92%) of paper. Korean proximate analysis of the waste mixed with sewage sludge and industrial waste (3 : 7, volumetric basis) showed 16.3% of moisture, 70.5% of volatile solids, and 13.2% of ash, respectively. Low heating value of the mixed waste was 4,513kcal/kg. So it was thought that the mixed waste of sewage sludge and industrial waste (containing 43% of plastics and 12% papers) has enough heating value for co-incineration. The incineration of mixed waste showed the lowest SOx and NOx concentrations at $700^{\circ}C$. However, the operation at $950^{\circ}C$ was feasible in considering dioxin and the other hazardous gases. It was concluded that use of $Ca(OH)_2$ should be under investigation for the operation at $950^{\circ}C$.

Study on Thermal Dewatering of Sludge Using the Parabolic Through Collector(PTC) Solar Collector (PTC태양열 집열기를 이용한 슬러지 열탈수 연구)

  • Lee, Jung-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.49-56
    • /
    • 2014
  • A fiat-plate or vacuum tube solar collector have been mainly used for hot water supply of house because of some being difficult to get uniform energy density, so little applied into industrial field. This study is to apply the PTC(parabolic trough collector) solar collector into industrial field such as sludge dewatering system for energy reduction. The real scale system which composed of PTC Solar Collector and Thermal Dewatering (TDW) is established. PTC solar collector is designed to produce a hot water with $80^{\circ}C$ of temperature. And size of TDW is $630{\times}630mm$. Hot water produced from PTC solar collector is supplied into heating plate of TDW, and sludge like waterworks or wastewater is dewatered. PTC solar collector with $10m^2$ of area produce energy of average 5,618 kcal. As according to results from real scale performance, solar collector takes charge 94 % of the amount that TDW consume energy which is so large part if compare with boiler. It means that PTC solar collector is useful to apply industrial field under the condition of sufficient solar radiation. And it is analyzed that TDW by PTC solar collector has an economical validity.

Study on Bio-H2 Production from Synthetic Food Waste and Activated Sludge from Industrial Waste Water Processes using Dark-fermentation (산업공정의 폐수처리에서 발생된 폐활성슬러지 및 인공음식폐기물을 이용한 생물학적 수소생성에 관한 연구)

  • Kim, Tae-Hyeong;Kim, Mi-Hyung;Lee, Myoung-Joo;Hwang, Sun-Jin;Eom, Hyoung-Choon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.703-712
    • /
    • 2010
  • This study performed to extract operation factors of major organic wastes, which were food wastes and waste activated sludge generated in industries in order to use them as a substrate for bio-H2 production. According to the results of experimental analysis for hydrogen production capacity by various organic concentrations, the hydrogen production yield was the highest at 80 g/L, and the efficiency was improved by the pretreatment of waste activated sludge (acid treatment, alkali treatment). Hydrogen production efficiency was improved by mixing food wastes and waste activated sludge if waste activated sludge was below than 30%, however, it was decreased when it was more than 50%. The impacts of heavy metals on the hydrogen production shows that the inhibition level depends on the concentration of Cr, Zn, and Cu, Fe was able to enhance the hydrogen production.

Drying Characteristics of Plating Sludge by Microwave (마이크로파 가열에 의한 도금슬러지 건조특성)

  • 문경환;손종렬;김덕찬
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.9-15
    • /
    • 1998
  • Microwave heating and drying processes have been well established in various industrial applications. Feasibilities of successful application of microwave drying to many material have been shown on the laboratory or pilot-plant scale. The microwave drying behavior of plating sludge are considered in this paper. The plating sludge containing 70%, 80% and 90% water exposed to microwave power at 2,450 MHz, 700W. An experimental microwave drying apparatus was designed and constructed to monitor weight loss during drying. By studying the drying characteristic curve, the moisture in sludge was almost classified into two categories : free moisture and intestinal moisture. And the critical moisture contents at which the drying rate ceases to be constant were from 10.1 to 10.5%. A simple drying model is proposed which may be used to describe drying behavior of plating sludge. The constant rate and the falling rate periods in microwave drying were addressed separately. From the eqation of constant rate period the drying rate constants decreased exponentially with increasing depth. Microwave heating compared with conventional heating offered higher heating rates from 9 to 16 times. Therefore, microwave drying process can be effective in removing moisture from plating sludge.

  • PDF