• Title/Summary/Keyword: industrial chimney

Search Result 20, Processing Time 0.022 seconds

A Study on Drone Flight Trajectory for Accurate Detection of Air Pollutant Emission Designation (정확한 대기오염물질 배출 지정 탐지를 위한 드론 비행 궤도에 관한 연구)

  • Kim, Suyeong;Lee, Sukhoon;Jeong, Dongwon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.15-17
    • /
    • 2021
  • This paper proposes a drone flight trajectory method for accurate air pollutant emission designation detection. In areas with many factories, such as industrial complexes, there are workplaces that illegally emit air pollutants in a situation where monitoring is neglected. In the past, studies have been actively conducted to measure air pollutants in these areas using drones. The measurement method using a drone uses a method of detecting pollution by stopping around the chimney of a factory, but it has a problem in that the detection of air pollutants is inaccurate depending on environmental factors such as air pressure and wind. Therefore, this paper proposes a drone flight trajectory method for accurate air pollutant emission designation detection. This paper devises a screw orbit flight method in which a drone flies upward while rotating the chimney, and the total area of the chimney is detected and measured considering environmental factors. In the experiment, our proposal shows a higher performance than the existing method.

  • PDF

Seismic Fragility Evaluation of Chimney Structure in Power Plant by Finite Element Analysis (유한요소 해석을 통한 발전소 연돌 구조물의 지진취약도 분석)

  • Kwon, Gyu-Bin;Kim, Jin-Sup;Kwon, Min-Ho;Park, Kwan-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.276-284
    • /
    • 2019
  • Seismic research on bridges, dams and nuclear power plants, which are infrastructure in Korea, has been carried out since early on, but in the case of structures in thermal power plants, research is insufficient. In this study, a total of 192 dynamic analyzes were performed for 16 actual seismic waves and 12 PGAs. As a result, the probability of failure increased as the PGA value increased for each applied seismic wave, but it was different for each seismic wave. As a result, at 0.22G, the ratio of the compressive limit reached to the limit state was 25% and the ratio of the relative displacement reached the limit state was 13%. So, the probability of collapse due to compressive failure Is higher. Therefore, the fragility curve of the chimney which is the subject of this study can be used as a quantitative basis to determine the limit state of the target structure when an earthquake occurs and to be used for the safety design of the thermal power plants.

Modal Identification of a Slender Structure using the Proper Orthogonal Decomposition Method (Proper Orthogonal Decomposition 기법을 이용한 세장한 구조물의 모드인자 파악)

  • Ham, Hee-Jung
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.135-141
    • /
    • 2008
  • In this paper, the Proper Orthogonal Decomposition (POD) method, which is a statistical analysis technique to find the modal characteristics of a structure, is adapted to identify the modal parameters of a tall chimney structure. A wind force time history, which is applied to the structure, is obtained by a wind tunnel test of a scale down model. The POD method is applied on the wind force induced responses of the structure, and the true normal modes of the structure can be obtained. The modal parameters including, natural frequency, mode shape, damping ratio and kinetic energy of the structure can be estimated accurately. With these results, it may be concluded that the POD method can be applied to obtain accurate modal parameters from the wind-induced building responses.

  • PDF

Numerical Analysis of Collapse Behavior in Industrial Stack Explosive Demolition (산업용 연돌 발파해체에서 붕괴거동에 관한 수치해석적 연구)

  • Pu-Reun Jeon;Gyeong-Jo Min;Daisuke Fukuda;Hoon Park;Chul-Gi Suk;Tae-Hyeob Song;Kyong-Pil Jang;Sang-Ho Cho
    • Explosives and Blasting
    • /
    • v.41 no.3
    • /
    • pp.62-72
    • /
    • 2023
  • The aging of plant structures due to industrialization in the 1970s has increased the demand for blast demolition. While blasting can reduce exposure to environmental pollution by shortening the demolition period, improper blasting design and construction plans pose significant safety risks. Thus, it is vital to consider optimal blasting demolition conditions and other factors through collapse behavior simulation. This study utilizes a 3-D combined finite-discrete element method (FDEM) code-based 3-D DFPA to simulate the collapse of a chimney structure in a thermal power plant in Seocheon, South Korea. The collapse behavior from the numerical simulation is compared to the actual structure collapse, and the numerical simulation result presents good agreement with the actual building demolition. Additionally, various numerical simulations have been conducted on the chimney models to analyze the impact of the duct size in the pre-weakening area. The no-duct, duct, and double-area duct models were compared in terms of crack pattern and history of Z-axis displacement. The findings show that the elapse-time for demolition decreases as the area of the duct increases, causing collapse to occur quickly by increasing the load-bearing area.

On the wind and earthquake response of reinforced concrete chimneys

  • Turkeli, Erdem;Karaca, Zeki;Ozturk, Hasan Tahsin
    • Earthquakes and Structures
    • /
    • v.12 no.5
    • /
    • pp.559-567
    • /
    • 2017
  • Slender structures like reinforced concrete (RC) chimneys are severely damaged or collapsed during severe wind storms or strong ground motions all over the world. Today, with the improvement in technology and industry, most factories need these slender structures with increasing height and decreasing in shell thickness causing vulnerable to winds and earthquakes. Main objectives in this study are to make structural wind and earthquake analysis of RC chimneys by using a well-known international standard CICIND 2001 and real recorded time history accelerations and to clarify weak points of these tall and slender structures against these severe natural actions. Findings of this study show that maximum tensile stress and shear stress approximately increase 103.90% and 312.77% over or near the openings on the body of the RC chimneys that cause brittle failure around this region of openings.

An Analysis of the Place Branding Methods for Regenerated Idle Industrial Facilities (재생 유휴산업시설의 플레이스 브랜딩 방법 분석)

  • Cho, Youn-Joo;Shin, Kyung-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.1
    • /
    • pp.54-63
    • /
    • 2015
  • This study aims to suggest the place branding methods applicable for regenerated idle industrial facilities. The place branding methods were analyzed by separating into hard branding methods and soft branding methods, and the results of the study are as follows: As for the hard branding methods, the exterior, outer wall materials and interior materials of the building and industrial equipment are preserved to revive the historicity of the building. In order to organize a differentiated space, it is important to create the convenience space such as cafes, experience space, lounge, and restaurants as well as the space for the operation of the programs. The building itself is utilized as a landmark or the iconic facility such as the winding tower or chimney is utilized as a landmark. As the methods of introducing natural elements, there is a need to create the resting space, law area and water space where trees can be planted and landscape can be viewed, and the development of tourism products utilizing the peripheral resources and the link of programs are also important. As for the soft branding methods, the provision of programs where a variety of art genres and the sense of place are reflected and the programs linked to the region is needed, and the story of place can be shared by storytelling utilizing the work and programs reflecting the sense of place. In addition, the content development and physical improvement of facilities reflecting the needs of visitors and the establishment of the organic collaboration system of a variety of subjects are needed for the sustainability of place.

Development of atmospheric environment information collection system using drone (드론을 이용한 대기환경정보 수집장치 개발 및 응용 연구)

  • Kim, Nam Ho
    • Smart Media Journal
    • /
    • v.7 no.4
    • /
    • pp.44-51
    • /
    • 2018
  • The purpose of this research is to collect atmospheric environmental information at specific altitudes in a range of 0 to 1 km above the surface and to monitor it using drones. The corresponding temperature and humidity were measured with the meteorological factors, and the amounts of fine dust and $CO_2$ were observed by the environmental factors so that they could receive the normal values. Monitoring the status of atmospheric gas emission in specific enterprises, industrial complexes and regions through the measurement is meant to help establish policies to reduce pollution factors. In conventional means previously practiced, exhaust gas detection accompanies a great deal of risks in terms of safety because the surveyor is directly exposed to the source of contamination such as the holes installed in the chimney. However, in our proposed method, the drone can collect information in a wide range under safe circumstances, which can be utilized through wide industrial areas.

Comparison of Shallow Model Tunnel Test Using Image Processing and Numerical Analysis (이미지 프로세싱을 이용한 얕은 터널 모형실험과 수치해석의 비교)

  • Lee, Yong-Joo
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.7
    • /
    • pp.5-12
    • /
    • 2006
  • In this study, 2D shallow tunnel model test using close range photogrammetric technique was conducted with aluminium rods simulating continuum granular material. Numerical analysis was also carried out in order to identify the behaviour of subsurface deformations caused by shallow tunnelling. Direction and magnitude of displacement vectors from the model test were identical to the result of numerical analysis based on the model data. In particular, it is shown that the vector direction was toward a point below the tunnel invert level. A narrow "chimney or tulip like" pattern of vertical displacement was confirmed by both the model test and numerical analysis. This behaviour is consistent with the field data. In addition to the qualitative comparison, the quantitative result of subsurface settlements according to 2D volume loss showed good agreement between the model test and numerical analysis. Therefore, close range photogrammetric technique applied in the model test may be used to validate the result from the continuum numerical analysis.

A Study on the Design Concept & Construction Method of Office Building with Stacks at Thermal Power Plant (화력발전소 연돌통합형 종합사무동의 설계개념과 시공공법 연구)

  • Kim, Si-Hyun;Choi, Jang-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.677-686
    • /
    • 2016
  • A thermal power plant is the first CFBC (Circulating Fluidized Bed Combustion) power plant consisting of 2 boilers-1 turbine. The optimal height of a stack needs to be approximately 156 meters in the case of this thermal power plant; however, the thermal power plant sites satisfy a function and reduce the construction cost by using mountains in the sites after cutting the ground and locating an integrated office and chimney at an altitude of 70 meters thereby lowering the height of the stack to 86 meters. In addition, the integrated office, which has a combined stack style with a unique design, is constructed by connecting with 2 stacks and disposing the office and an observatory in the space between them. Therefore, this study examined the design concept that fulfils the structural, functional, and aesthetic factors, harmoniously by joining the integrated office and the stack, which are disparate, and investigated special construction methods (Slip Form, Steel Inner Flue & Lift-up) through which heterogeneous architectures are structurally, functionally, and aesthetically constructed.

Comparison of Airborne Lead Concentration in and Around Lead Production Plant (재생 납 생산 공장과 인근 지역의 공기 중 납 농도 수준 비교)

  • Park, Changhwan;Park, Yunkyung;Oh, Younhee;Choi, Inja;Cha, Wonseok;Choi, Sangjun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.1
    • /
    • pp.34-41
    • /
    • 2019
  • Objective: This study is conducted to evaluate airborne lead concentration in and around lead production plant. Methods: Airborne lead concentration was monitored simultaneously inside of the processes of lead recycling factory and outside of factory which include stack, boundary of factory and residential area 1 km and 7.5 km from factory, respectively. All samples were measured three times at 1.5 m from the ground and analyzed using inductively coupled plasma mass spectrometer, inductively coupled plasma optical emission spectrometer or flame atomic absorption spectrometer. Results: All airborne lead concentrations measured inside of factory($13.9{\mu}g/m^3-252.9{\mu}g/m^3$) and outside of factory($0.001{\mu}g/m^3-54.97{\mu}g/m^3$) showed log-normal distribution. Geometric mean lead concentration, $54.81{\mu}g/m^3$, measured inside of factory was significantly higher than outside of factory, $0.20{\mu}g/m^3$(p<0.01). Among the samples measured inside the factory, lead concentration was the highest in the refining process($59.02{\mu}g/m^3-252.9{\mu}g/m^3$). In the case of the samples outside the factory, the nearest chimney was the highest($3.84{\mu}g/m^3-54.97{\mu}g/m^3$), and the lead concentration at the farthest place, 7.5 km from the factory was the lowest($0.001{\mu}g/m^3-1.7{\mu}g/m^3$). The arithmetic lead concentration, $0.45{\mu}g/m^3$ in the residential area near the factory was below the atmospheric environment standard of $0.5{\mu}g/m^3$, but the maximum concentration of $3.4{\mu}g/m^3$ was exceeded. Conclusions: Airborne lead concentration in residential area, 1 km away from lead recycling plant, may exceed ambient air standard of $0.5{\mu}g/m^3$.