• Title/Summary/Keyword: industrial buildings

Search Result 643, Processing Time 0.032 seconds

Seismic Performance Evaluation of Reinforced Concrete Moment Framed Low-story School buildings (철근콘크리트 모멘트 골조 저층형 학교건축물의 내진성능 평가)

  • Hwang, Ji-Hyun;Park, Tae-Won;Han, Ju-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4580-4586
    • /
    • 2013
  • Many school buildings are not applied seismic code because of small size structures. But it must be designed to show enough structural performance when subject to earthquake due to the fact that most of school buildings are generally used as public shelters when the natural disasters. In this study, the seismic risk of the reinforced concrete school building structure which is the most common types of school structures was evaluated by using the seismic performance evaluation methods. As a result, model structures don't have enough seismic performance.

Fragility-based rapid earthquake loss assessment of precast RC buildings in the Marmara region

  • Ali Yesilyurt;Oguzhan Cetindemir;Seyhan O. Akcan;Abdullah C. Zulfikar
    • Structural Engineering and Mechanics
    • /
    • v.88 no.1
    • /
    • pp.13-23
    • /
    • 2023
  • Seismic risk assessment studies are one of the most crucial instruments for mitigating casualties and economic losses. This work utilizes fragility curves to evaluate the seismic risk of single-story precast buildings, which are generally favored in Marmara's organized industrial zones. First, the precast building stock in the region has been categorized into nine sub-classes. Then, seven locations in the Marmara region with a high concentration of industrial activities are considered. Probabilistic seismic hazard assessments were conducted for both the soil-dependent and soil-independent scenarios. Subsequently, damage analysis was performed based on the structural capacity and mean fragility curves. Considering four different consequence models, 630 sub-class-specific loss curves for buildings were obtained. In the current study, it has been determined that the consequence model has a significant impact on the loss curves, hence, average loss curves were computed for each case investigated. In light of the acquired results, it was found that the loss ratio values obtained at different locations within the same region show significant variation. In addition, it was observed that the structural damage states change from serviceable to repairable or repairable to unrepairable. Within the scope of the study, 126 average loss functions were presented that could be easily used by non-experts in earthquake engineering, regardless of structural analysis. These functions, which offer loss ratios for varying hazard levels, are valuable outputs that allow preliminary risk assessment in the region and yield sensible outcomes for insurance activities.

Improvement of Fire Safety Management Plan in Response to Hydrogen Chloride Leak (염화수소 누출에 따른 소방계획서 개선방안)

  • Boohyun Baek;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.39-49
    • /
    • 2024
  • This study aims to propose an improvement of fire safety management plans for buildings, such as apartment complexes and schools, within a 10 km radius of industrial complexes. It utilizes an off-site consequence analysis program to reflect the toxic impact on national industrial complexes and surrounding areas. The ALOHA program was utilized to analyze the impact of toxicity due to a hydrogen chloride leak, a hazardous material. The results showed that the area with AEGL-2 and above ranged from 3.1 km to 10 km, the AEGL-3 area ranged from 1.9 km to 7.3 km. The ASET was measured to be between 3 and 24 minutes. Due to the impact of toxicity, it is necessary to prepare fire safety management plans for buildings, such as apartment complexes and schools that are within a 10 km radius from industrial complexes. These safety plans incorporate the hydrogen chloride risk assessment results, ASET, weather conditions, and coordination with the local community.

Health Risk Assessment and Evaluation of Asbestos Release from Asbestos-cement Slate Roofing Buildings in Busan (부산시내 석면슬레이트지붕 건축물로부터의 석면 노출 및 건강위해성 평가)

  • Jeong, Jae-Won;Cho, Sunja;Park, Geun-Tae;Lee, Sang-Joon
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1579-1587
    • /
    • 2013
  • This study was performed to evaluate the asbestos exposure levels and to calculate excess lifetime cancer risk (ELCR) for the risk assessment of the asbestos fibers released from asbestos-cement slate roofing (ASR) building. Total number of ASR buildings was into 21,267 in Busan, and 82.03 percent of the buildings was residential houses, and 43.61 percent of the buildings was constructed in 1970s. For this study, ten buildings were selected randomly among the ASR buildings. The range of airborne asbestos concentration in the selected ten ASR buildings was from 0.0016 to 0.0067 f/mL, and the concentration around no-admitted ASR buildings was higher than that around admitted buildings. The ELCR based on US EPA IRIS (integrated risk information system) model is within 3.5E-05 ~ 1.5E-04 levels, and the ELCR of no-admitted ASR buildings was higher than 1.0E-04 (one person per million) level that is considered a more aggressive approach to mitigate risk. These results indicate that the cancer risk from ASR buildings is higher than other buildings, and systematic public management is required for control of no-admitted ASR buildings within near future.

Assessment of ASCE 7-10 for wind effects on low-rise wood frame buildings with database-assisted design methodology

  • He, Jing;Pan, Fang;Cai, C.S.
    • Wind and Structures
    • /
    • v.27 no.3
    • /
    • pp.163-173
    • /
    • 2018
  • The design wind pressure for low-rise buildings in the ASCE 7-10 is defined by procedures that are categorized into the Main Wind Force-Resisting System (MWFRS) and the Components and Cladding (C&C). Some of these procedures were originally developed based on steel portal frames of industrial buildings, while the residential structures are a completely different structural system, most of which are designed as low-rise light-frame wood constructions. The purpose of this study is to discuss the rationality (or irrationality) of the extension of the wind loads calculated by the ASCE 7-10 to the light-frame wood residential buildings that represent the most vulnerable structures under extreme wind conditions. To serve this purpose, the same approach as used in the development of Chapter 28 of the ASCE 7-10 that envelops peak responses is adopted in the present study. Database-assisted design (DAD) methodology is used by applying the dynamic wind loads from Louisiana State University (LSU) database on a typical residential building model to assess the applicability of the standard by comparing the induced responses. Rather than the postulated critical member demands on the industrial building such as the bending moments at the knee, the maximum values at the critical points for wood frame buildings under wind loads are used as indicators for the comparison. Then, the critical members are identified through these indicators in terms of the displacement or the uplift force at connections and roof envelope. As a result, some situations for each of the ASCE 7 procedures yielding unconservative wind loads on the typical low-rise residential building are identified.

Site-Plan Types of Common Design's Goon Office Buildings and their Addition & Remodeling in Japanese Colonial Period (일제강점기 '공통형' 군청사의 배치 유형과 유형별 증·개축 경향)

  • Kim, Myungsun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7629-7634
    • /
    • 2015
  • The purpose of this study is is to organize the site-plan types of common design's Goon office buildings in Japanese colonial period based on the main building's shape and main & attached building connection way and to investigate all the types' addition & remodeling ways. The study used literature research method, analysing the digital images, the annotation of the images, official documents between the Japanese government-general of Korea and To, and articles of newspapers or journals. The site-plans are sorted 5 types and subdivided 13 as their addition & remodelling ways. The initial shapes of site-plan were changed to apply every Goon's site circumstances, The main buildings were always in the center ahead and attached buildings behind or next to them in any cases of new construction, addition or remodeling. The buildings of the common design's were constructed until early 1930s and it means that their architectural level was lower than Pu office buildings, although both had same administrational level.

Evaluating high performance steel tube-framed diagrid for high-rise buildings

  • Lee, Dongkyu;Ha, Taehyu;Jung, Miyoung;Kim, Jinho
    • Steel and Composite Structures
    • /
    • v.16 no.3
    • /
    • pp.289-303
    • /
    • 2014
  • In recent, development of construction and design technology gives taller, larger and heavier steel framed structures. With the tendency of increasing high-rise building, this study is strongly related to structural system, one of significant components in structural design. This study presents an innovative structural system, with high performance steel material, diagrid. Its detail, structural analysis, and structural experiments are all included for the development of new structures.

Observational failure analysis of precast buildings after the 2012 Emilia earthquakes

  • Minghini, Fabio;Ongaretto, Elena;Ligabue, Veronica;Savoia, Marco;Tullini, Nerio
    • Earthquakes and Structures
    • /
    • v.11 no.2
    • /
    • pp.327-346
    • /
    • 2016
  • The 2012 Emilia (Italy) earthquakes struck a highly industrialized area including several thousands of industrial prefabricated buildings. Due to the lack of specific design and detailing for earthquake resistance, precast reinforced concrete (RC) buildings suffered from severe damages and even partial or total collapses in many cases. The present study reports a data inventory of damages from field survey on prefabricated buildings. The damage database concerns more than 1400 buildings (about 30% of the total precast building stock in the struck region). Making use of the available shakemaps of the two mainshocks, damage distributions were related with distance from the nearest epicentre and corresponding Pseudo-Spectral Acceleration for a period of 1 second (PSA at 1 s) or Peak Ground Acceleration (PGA). It was found that about 90% of the severely damaged to collapsed buildings included into the database stay within 16 km from the epicentre and experienced a PSA larger than 0.12 g. Moreover, 90% of slightly to moderately damaged buildings are located at less than 25 km from the epicentre and were affected by a PSA larger than 0.06 g. Nevertheless, the undamaged buildings examined are almost uniformly distributed over the struck region and 10% of them suffered a PSA not lower than 0.19g. The damage distributions in terms of the maximum experienced PGA show a sudden increase for $PGA{\geq}0.28g$. In this PGA interval, 442 buildings were collected in the database; 55% of them suffered severe damages up to collapse, 32% reported slight to moderate damages, whereas the remaining 13% resulted undamaged.

A Study on u-Residential Space Service of Ubiquitous Vertical Farm (Ubiquitous Vertical Farm의 u-주거공간 서비스 도출에 관한 연구)

  • Lee, Heang-Woo;Kim, Yong-Seong;Lee, Jae-Il
    • Journal of the Korean housing association
    • /
    • v.23 no.5
    • /
    • pp.51-60
    • /
    • 2012
  • Large-scale urban developments with increasing population and expansion of industrial facilities have destroyed the ecosystem. Consequently, the importance of vertical farm as a form of urban agriculture is increasing. However, such problems of vertical farms as economy and lack of awareness of residents are being raised. Firstly, this study derived types of vertical farm that are applicable to residential spaces through an examination of vertical farm buildings, and then inferred assessment items for a questionnaire survey for the development of u-services. Secondly, based on the issues deduced from the survey, u-services needed in vertical farm buildings were derived to use them as the basic data when we plan for a ubiquitous vertical farm building in residential space in the future. As result, the following uservices of ubiquitous vertical farm were proposed: u-notification service about the condition of crops from the aspect of growth management based on ubiquitous technology, remote/automatic control u-services, harvest information u-service for harvest management, recipe information u-service, and indoor air quality monitoring u-service, indoor environment adjusting u-service, and farm environment control u-service. Considering that many new buildings in Korea are residential buildings and many high-rise buildings are being planned, studies on vertical farm buildings must be continued.

Progressive collapse vulnerability in 6-Story RC symmetric and asymmetric buildings under earthquake loads

  • Karimiyan, Somayyeh;Kashan, Ali Husseinzadeh;Karimiyan, Morteza
    • Earthquakes and Structures
    • /
    • v.6 no.5
    • /
    • pp.473-494
    • /
    • 2014
  • Progressive collapse, which is referred to as the collapse of the entire building under local damages, is a common failure mode happened by earthquakes. The collapse process highly depends on the whole structural system. Since, asymmetry of the building plan leads to the local damage concentration; it may intensify the progressive collapse mechanism of asymmetric buildings. In this research the progressive collapse of regular and irregular 6-story RC ordinary moment resisting frame buildings are studied in the presence of the earthquake loads. Collapse process and collapse propagation are investigated using nonlinear time history analyses (NLTHA) in buildings with 5%, 15% and 25% mass asymmetry with respect to the number of collapsed hinges and story drifts criteria. Results show that increasing the value of mass eccentricity makes the asymmetric buildings become unstable earlier and in the early stages with lower number of the collapsed hinges. So, with increasing the mass eccentricity in building, instability and collapse of the entire building occurs earlier, with lower potential of the progressive collapse. It is also demonstrated that with increasing the mass asymmetry the decreasing trend of the number of collapsed beam and column hinges is approximately similar to the decreasing trend in the average story drifts of the mass centers and stiff edges. So, as an alternative to a much difficult-to-calculate local response parameter of the number of collapsed hinges, the story drift, as a global response parameter, measures the potential of progressive collapse more easily.