• 제목/요약/키워드: induction

검색결과 12,050건 처리시간 0.04초

그래픽 프로그래밍 기법을 주축용 유도전동기의 속도 센서리스 토크감시 (Speed Sensorless Torque Monitoring of Induction Spindle Motor using Graphic programming)

  • 박진우;홍익준;권원태
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.319-322
    • /
    • 1997
  • In vector control technique, stator currents of an induction motor are transformed to equivalent d-q currents in reference frame consist of d and q axis, each of which is coincide with flux and torque direction respectively. In this paper, the new algorithm is suggested where the stator current through an induction motor torque is monitored by using a vector control method where an additional equipment is not need. The G-programming is used to apply the suggested algorithm in the experiment and this is applied to an actual system to monitor the torque value of an induction motor on real time. To solve the vibration trouble of estimated torque caused from an unbalanced real rotating speed of an induction motor and measured rotating speed by suggesting the reconstructed in a method based on measurement current signal. This produced system testifies an accuracy of an induction motor through the experiment by comparing the reference value of the control method.

  • PDF

용융아연도금라인(HGL)의 Induction Type Furnace 적용 (Application of the induction type furnace for HGL)

  • 이만식
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 제3회 압연심포지엄 논문집 압연기술의 미래개척 (Exploitation of Future Rolling Technologies)
    • /
    • pp.111-118
    • /
    • 1999
  • This article describes the basic engineering concepts to be considered in the application of an induction heating furnace in the hot-dip galvanizing line. Experience in the Dongkuk project in Pohang, has shown that this arrangement has many advantages over the conventional method of using a combustion-gas heated furnace. Investment and operating costs are lower, the line length is much shorter, line operation is more convenient, air pollution is reduced, and the coated strip at of top-quality. As these benefits become well known, it is anticipated that the concept of induction heating will be more widely used in both new and revamped process lines. Induction heating is suitable for the production of Commercial Quality hot galvanized coils. More research is required to extend the present concept to the production of higher forming grades such as Drawing, Deep Drawing and Extra Deep Drawing Quality steels. A combination of induction heating and combustion-gas heating may lead to the way to the processing of these qualities of strip.

  • PDF

전기신호를 이용한 전동기 온라인 고장진단 (Online Fault Diagnosis of Motor Using Electric Signatures)

  • 김낙교;임정환
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1882-1888
    • /
    • 2010
  • It is widely known that ESA(Electric Signature Analysis) method is very useful one for fault diagnosis of an induction motor. Online fault diagnosis system of induction motors using LabVIEW is proposed to detect the fault of broken rotor bars and shorted turns in stator. This system is not model-based system of induction motor but LabVIEW-based fault diagnosis system using FFT spectrum of stator current in faulty motor without estimating of motor parameters. FFT of stator current in faulty induction motor is measured and compared with various reference fault data in data base to diagnose the fault. This paper is focused on to predict and diagnose of the health state of induction motors in steady state. Also, it can be given to motor operator and maintenance team in order to enhance an availability and maintainability of induction motors. Experimental results are demonstrated that the proposed system is very useful to diagnose the fault and to implement the predictive maintenance of induction motors.

소수력에 적용한 동기발전기와 유도발전기의 운전 특성 비교 (A comparison of the operating characteristics of the synchronous generator and induction generator applied to the small hydroelectric power plant)

  • 김종겸;김영국
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.55-60
    • /
    • 2014
  • In general, A synchronous generator is higher than the voltage stability of the induction generator. However, induction generator has many advantages rather than a synchronous generator in terms of price and maintenance. So, coverage rate of the induction generator is gradually increasing in small hydroelectric power station rather than 1000kW recently. In order to increase the penetration of induction generator, pre-analysis of the operation of the generator is needed. In this study, we analyzed for the problems that occur when synchronous generator and induction generator of 1500kW is connected to the distribution system.

배전선로에 유도발전기 연결시 역률 변동에 관한 연구 (A study on the variation of power factor by connection of the induction generator to the distribution line)

  • 김종겸;박영진;이경배;김영국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1469-1470
    • /
    • 2015
  • Recently induction generator has been applied to many small hydro power plants. Induction generator needs a reactive power for magnetization. The reactive power of induction generator is being supplied from the supply side mostly. The use of induction generators in the power distribution grid can affect the power factor. The power factor of induction generator is fixed already during production. The power factor in the distribution system is due to the increase or decrease of the load rather than due to the induction generator. In this study, we analyzed how the power factor is changed according to the load increase or decrease in the distribution lines.

  • PDF

관측기관을 이용한 유도전동기의 센서리스 속도제어 (Sensorless Speed Control of Induction Motor Using Observation Technique)

  • 이충환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권1호
    • /
    • pp.96-102
    • /
    • 1999
  • Sensorless speed estimation in induction motor systems is one of the most control engineers. Based on the estimated speed the vector control has been applied to the high precision torque control however most speed estimation methods use adaptive scheme so that it takes long time to estimate the speed. Thus the adaptive estimation scheme is not effective to the induction motor which requires short sampling time. In this paper a new linearized equation of induction motor system is proposed and a sensorless speed estimation algorithm based on observation techniques is developed. First the nonlinear induction motor equation is linearized at an equilibrium point. Second a proportional integral(PI) observer is applied to estimate the speed state in the induction motor system. Finally simulation results will assure the effectiveness of the new linearized equation and the sensorless estimation algorithm by using PI observer in the nonlinear induction motor system.

  • PDF

Characteristics of the Two-phase Induction Motor By the Inverter Fed Control

  • Yang Byoung-Yull;Kwon Byung-Il
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.312-316
    • /
    • 2005
  • The single phase induction motor has been commonly applied to small-sized electrical appliances because of its low cost, but it has low efficiency and large torque ripple, and it is incapable of speed control. However, two-phase induction motors have small torque ripple, high efficiency and variable speed control, because they are inverter fed. In this paper, the dynamic characteristics of the two-phase induction motor, such as the torque ripple, current and speed, are analyzed by using the time-stepping finite element method, and compared with the cage-type single phase induction motor.

A Study on the Modeling and Design of Single Phase Induction Generators

  • Kim Cherl-Jin;Lee Kwan-Yong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.331-336
    • /
    • 2005
  • With increasing emphasis on non-conventional energy systems and autonomous power generation, development of improved and appropriate generating systems has recently taken on greater significance. This paper describes the performance analysis of a single phase self-excited induction generator (SEIG), suitable for autonomous/standby power systems. The system is also appropriate for wind energy systems and small portable systems. Both windings of the induction machine, the main and the auxiliary, are utilized. One winding will be devoted to the supply excitation current only, by being connected to the excitation capacitor, while the load is connected across the other winding. As the design of excitation, the minimum of self-excited capacitor connected auxiliary winding is determined as the suitable value using a circuit equation of auxiliary winding. For the steady state analysis, the equivalent circuit of the single-phase induction generators is used as a basis for modeling using the double-revolving field theory. The validity of the designed generator system is confirmed by experimental and computed results.

비접촉 회전 스테이지에의 구동 원리로서의 횡자속 원주형 유도 방법 (Transverse flux circumferential induction method as a driving principle of the contact-free revolving stage)

  • 김효준;정광석
    • 한국정밀공학회지
    • /
    • 제22권10호
    • /
    • pp.72-79
    • /
    • 2005
  • Compared with linear induction principle, the transverse flux circumferential induction principle is suggested as a driving mechanism of the revolving stage, which can rotate contactlessly without any supporting structure. The stage realizes the integrated motion of levitation, rotation, and planar perturbation, using the two-axis forces, normally directed force of the air-gap and tangential force, of the induction drivers mounted on the stator uniformly. In this paper, the force generating mechanism of the stage is described in detail. First, the various core shapes generating the transverse flux are analyzed to guarantee the proper thrust force. And the vector force intensity of the circumferential induction driver constituting the stage is compared with that of the linear induction driver. Especially it is shown that the magnetic force of the suggested system can be modeled with the linear equivalent model, including the test verification.

일반 및 고효율 유도 전동기의 특성 비교 해석 (Characteristic Comparison Analysis for Standard and High-Efficiency Induction Motor)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제56권4호
    • /
    • pp.186-190
    • /
    • 2007
  • This paper presents an analysis on the power characteristics of standard and high-efficiency induction motor. The parameter of induction motor play an important role in the expression of machine's performance characteristics. Induction motor can be differently found its characteristics parameters with the operation under the same capacity. So it is very difficult to detect correct parameter of induction motor. For the analysis, we discovered the motor parameters by the technical program with nameplate data. In this paper, we analyzed that how power and torque characteristics of induction motor would be changed for two kinds of motor parameters.