• 제목/요약/키워드: indoor radon concentration

검색결과 86건 처리시간 0.02초

Determination of 226Ra in TENORM Sample Considering Radon Leakage Correction

  • Lim, Sooyeon;Syam, Nur Syamsi;Maeng, Seongjin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • 제46권3호
    • /
    • pp.127-133
    • /
    • 2021
  • Background: Phosphogypsum is material produced as a byproduct in fertilizer industry and is generally used for building materials. This material may contain enhanced radium-226 (226Ra) activity concentration compared to its natural concentration that may lead to indoor radon accumulation. Therefore, an accurate measurement method is proposed in this study to determine 226Ra activity concentration in phosphogypsum sample, considering the potential radon leakage from the sample container. Materials and Methods: The International Atomic Energy Agency (IAEA) phosphogypsum reference material was used as a sample in this study. High-purity germanium (HPGe) gamma spectrometry was used to measure the activity concentration of the 226Ra decay products, i.e., 214Bi and 214Pb. Marinelli beakers sealed with three different sealing methods were used as sample containers. Due to the potential leakage of radon from the Marinelli beaker (MB), correction to the activity concentration resulted in gamma spectrometry is needed. Therefore, the leaked fraction of radon escaped from the sample container was calculated and added to the gamma spectrometry measured values. Results and Discussion: Total activity concentration of 226Ra was determined by summing up the activity concentration from gamma spectrometry measurement and calculated concentration from radon leakage correction method. The results obtained from 214Bi peak were 723.4 ± 4.0 Bq·kg-1 in MB1 and 719.2 ± 3.5 Bq·kg-1 in MB2 that showed about 5% discrepancy compared to the certified activity. Besides, results obtained from 214Pb peak were 741.9 ± 3.6 Bq·kg-1 in MB1 and 740.1 ± 3.4 Bq·kg-1 in MB2 that showed about 2% difference compared to the certified activity measurement of 226Ra concentration activity. Conclusion: The results show that radon leakage correction was calculated with insignificant discrepancy to the certified values and provided improvement to the gamma spectrometry. Therefore, measuring 226Ra activity concentration in TENORM (technologically enhanced naturally occurring radioactive material) sample using radon leakage correction can be concluded as a convenient and accurate method that can be easily conducted with simple calculation.

스크린도어 설치 후 서울지하철역 라돈 농도의 변화 특성 (A Noticeable Change in Indoor Radon Levels After Platform Screen Doors Installation in Seoul Subway Station)

  • 전재식;윤종철;이호찬;엄석원;채영주
    • 한국대기환경학회지
    • /
    • 제28권1호
    • /
    • pp.59-67
    • /
    • 2012
  • Platform screen doors (PSD) installed at 289 stations in Seoul metropolitan subway from November 2005 to December 2009, are expected to prevent death from a fall and improve air quality. In this study, we systematically surveyed changes in radon concentrations before and after PSD installation in Seoul metropolitan subway stations. By solid-state nuclear track detectors (SSNTD), the radon concentrations before and after the PSD installation were measured at 54 stations of 6 lines from 2 to 7 reported to have relatively high radon concentrations. Mean radon concentrations at platforms were decreased by approximately 56% from 121.7 Bq/$m^3$ to 54.0 Bq/$m^3$. Before PSD installation, mean radon concentrations were in the decreasing order for subway lines 7, 5, 6, 3, 4 and 2. On the other hand, after PSD installation the order was changed to 5, 6, 7, 3, 4 and 2. According to a radon map of Seoul metropolitan subway, the number of platforms where radon concentration over was 74 Bq/$m^3$ decreased from 38 to 12 after PSD installation.

서울.경기지역 초.중.고등학교 교실의 실내공기오염에 관한 연구 (A Study on the Indoor Air Pollution in the Classrooms of Primary, Middle and High Schools in Seoul and Gyeonggi-Do)

  • 김윤신;이철민;문정숙;김상욱
    • 한국학교보건학회지
    • /
    • 제16권1호
    • /
    • pp.81-90
    • /
    • 2003
  • This study was conducted to contribute to the basic data for decisions on environment policy improvement in health promotion for students in elementary, middle and high schools. This study was carried out to investigate the extent of indoor air pollution in elementary, middle and high schools in residential, traffic congestional and industrial areas. The concentrations of major indoor air pollutants(carbon monoxide, carbon dioxide, respiratory particulate, radon) and thermocircumstance (temperature, relative humidity, intensity of illumination) indices were observed from June to August 2000. As results of the survey, the mean values of thermocircumstance in school were $26.94{\pm}1.15^{\circ}C$ of temperature, $68.88{\pm}5.31%$ of humidity and $268.26{\pm}164.60$ Lux of intensity of illumination. The mean concentrations of carbon monoxide, carbon dioxide, respiratory particulate were $8.36{\pm}0.29\;ppm$, $547.66{\pm}175.58\;ppm$, $36.23{\pm}48.39\;{\mu}g/m3$, respectively. These values were lower than those of the indoor environmental standard on the first clause of Article 45 of public utilization service notified public hygiene of the Ministry of Health and Social Affairs. The mean concentration of radon was $20.07{\pm}17.95\;Bq/m3$. Which was below the U.S. EPA radon action level.

건물 저층과 고층에서 환기와 공기정화 식물을 통한 라돈 농도의 비교 (Comparing the Effects of Ventilation and Air Purification Plants on Radon Concentration in the Lower and Upper Floors of a Building)

  • 공유진;남소영;신민서;장혜림;전민철;유세종;김성호
    • 한국방사선학회논문지
    • /
    • 제14권7호
    • /
    • pp.881-889
    • /
    • 2020
  • 본 연구는 건물의 저층과 고층에서 환기와 공기정화 식물을 통한 라돈의 농도 변화를 정량적으로 측정하고자 하였다. 건물의 저층과 고층에서 라돈 농도 측정을 위해 시간을 설정하고 라돈 측정기를 이용하여 실내를 폐쇄 했을 때와 환기, 공기정화식물을 배치했을 때의 라돈 농도를 각각 측정하여 비교하였다. 폐쇄, 환기, 공기정화식물 배치에 따라 라돈 농도 변화에 유의한 차이를 보이는지 검증하고자 일원배치 분산분석(One-way ANOVA)를 시행하였다. 실험 결과 건물의 저층과 고층에서 환기와 공기정화식물 배치를 통한 라돈 농도의 감소는 통계적으로 유의한 차이를 보였으며, 환기와 공기정화식물을 배치 했을 때에는 통계적으로 유의한 차이점을 나타내지 않았다. 따라서 건물내 환기 뿐만 아니라 공기정화식물을 적절히 활용하면 라돈 농도를 효과적으로 감소시킬 수 있을 것으로 사료된다.

제주도 고산지역의 라돈 배경농도 실시간 모니터링 (Real-time monitoring of radon background level at Gosan site, Jeju Island)

  • 강창희;김원형;허철구;강동훈
    • 분석과학
    • /
    • 제25권1호
    • /
    • pp.7-13
    • /
    • 2012
  • 제주도 고산지역에서 라돈($^{222}Rn$)을 실시간 모니터링하여 대기 중의 배경농도 수준을 확인하였다. 고산지역의 라돈 농도는 평균 2831 $mBq/m^3$ (0.077 pCi/L)로 우리나라 실내 평균농도보다는 19.5배 낮은 배경농도 수준을 나타내었다. 계절별로는 봄, 여름, 가을, 겨울에 각각 2657, 2071, 3249, 3384 $mBq/m^3$ 농도를 보여 겨울에 높고 여름에 낮은 것으로 조사되었다. 월별로는 10월에 가장 높고 7월에 가장 낮은 농도를 나타내었다. 일간 농도는 오전 7시에 하루 중 가장 높은 농도를 보였고, 오후 2~3시경에 가장 낮은 농도를 나타내는 것으로 확인되었다. 역궤적 분석 결과, 라돈 농도는 기류의 유입경로에 따라 차이를 보였고, 아시아대륙으로부터 제주도로 이동했을 때 농도가 높고 북태평양으로부터 기류가 유입될 때 훨씬 더 낮은 농도를 나타내었다.

NATM 공법에 의한 고속도로 터널 공사 중 라돈 노출 평가 (Evaluation of Radon Exposure During Highway Tunnel Construction by New Austrian Tunneling Method)

  • 유예지;김형렬;강모열;최상준
    • 한국산업보건학회지
    • /
    • 제33권2호
    • /
    • pp.115-125
    • /
    • 2023
  • Objectives: This study was conducted to measure the level of radon in the air at a highway tunnel construction site in a gneiss area using the New Austrian Tunneling Method (NATM) and to evaluate exposure levels by occupation. Methods: Radon concentrations in the air were measured using E-PERM at points 300 m, 600 m, and 900 m from the tunnel entrance during the excavation and waterproofing work inside the tunnel. In addition, radon concentrations were measured during external excavation to compare with the inside of the tunnel. Personal exposure levels for major occupations including tunnel workers, construction equipment operators, waterproofers, shotcrete workers, and safety and health managers who participated in the construction were estimated using radon concentration measured in the work process area and working hours by occupation. Results: As a result of a total of 77 radon measurements, the geometric mean (GM) concentration was 71.1 Bq/m3, and the maximum concentration was 127.3 Bq/m3, which was below the indoor air quality criteria. Radon concentration by process decreased in the order of the tunnel excavation process (GM= Bq/m3, GSD=1.2), waterproofing process (GM=73.35 Bq/m3, GSD=1.2), and outside excavating process (GM=45.28 Bq/m3, GSD=1.2). Processes inside the tunnel were significantly higher than outside excavating processes (p<0.05). There was no statistically significant difference in radon concentration measured inside by distance from the tunnel entrance, but the innermost point of the tunnel, 900 m (GM=79.24 Bq/m3, GSD=1.27), measured the highest. Conclusions: The occupation with the highest individual exposure to radon was tunnel worker (64.16 Bq/m3), followed by construction equipment driver (64.04 Bq/m3) and waterproofer (63.13 Bq/m3).

수도권 지하철 전동차에서의 라돈 농도 분포 조사 (Indoor Radon Levels in the Subway Cabins of the Seoul Metropolitan Area)

  • 전재식;서종원;전명진;엄석원;채영주
    • 한국대기환경학회지
    • /
    • 제28권4호
    • /
    • pp.374-383
    • /
    • 2012
  • In this study, we have observed the airborne radon levels in the subway cabins before and after platform screen doors (PSD) installation. The measurements have been conducted at Seoul metropolitan subway lines in 2008, 2009 and 2010. The mean concentration of the radon inside subway cabins were increased by approximately 53% from $20.1Bq/m^3$ to $30.8Bq/m^3$ by installing PSD. After PSD installation, measured values for the different lines were rather different, and varied between 8.2 and $76.5Bq/m^3$. And mean radon concentrations were in the decreasing order for subway lines 5, 6, 7, 8, 3, 4, 2, 9 and 1. It was also found that the indoor radon concentrations in the subway cabins were highly dependent on the management approach of a ventilation system at the subway stations. By assuming an average of $720\;h\;year^{-1}$ and $2,880\;h\;year^{-1}$ spent in subway cabin, effective doses to passengers and employee were estimated. The expected annual effective dose, in case of an equilibrium factor of 0.4, were $0.07mSv\;y^{-1}$ and $0.26mSv\;y^{-1}$, respectively.

라돈 농도 분포도 작성을 위한 단변량 크리깅 기법의 정량적 비교 (Quantitative Comparison of Univariate Kriging Algorithms for Radon Concentration Mapping)

  • 곽근호;김용재;장병욱;박노욱
    • 한국지리정보학회지
    • /
    • 제20권1호
    • /
    • pp.71-84
    • /
    • 2017
  • 토양, 암석, 지하수로부터 실내에 유입되는 라돈은 인간에게 큰 위해를 끼치는 방사능 가스이다. 라돈 가스의 위해성을 확인하기 위해 실내 라돈 농도를 측정해 오고 있는데, 추가적인 분석 수행을 위해서는 신뢰성 높은 분포도 작성이 매우 중요하다. 본 연구에서는 비대칭 분포를 나타내는 라돈 농도의 공간 분포도 작성을 위해 단변량 크리깅 기법들의 비교를 목적으로 정규 크리깅, 비선형 자료 변환 기반의 로그 정규 크리깅, 다중 가우시안 크리깅과 지시자 크리깅의 예측 능력을 비교하였다. 예측 능력을 비교 분석하기 위해 잭나이프 방법을 이용하여 검증을 수행하였으며, 자료 구간별 오차와 샘플링 밀도의 차이에 따른 오차도 추가적으로 분석하였다. 남한 지역을 대상으로 한 사례 연구 결과에서 전반적으로 정규 크리깅에 비해 비선형 자료 변환 기반 크리깅 기법들이 좋은 예측 능력을 보였으며, 비선형 자료 변환 기반 크리깅은 로그 정규 크리깅, 다중 가우시안 크리깅 순으로 좋게 나타났다. 그러나 공간 패턴과 높은 값의 재생산을 고려할 때, 높은 값의 예측 능력은 정규 크리깅이 가장 우수하였다. 본 연구의 결과는 비대칭 분포 자료의 공간 예측을 위한 크리깅 기법의 선정에 유용하게 사용될 것으로 기대된다.

판재형 활성탄을 이용한 라돈 저감 연구 (A Study of Radon Reduction using Panel-type Activated Carbon)

  • 최일홍;강상식;전제훈;양승우;박지군
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.297-302
    • /
    • 2017
  • 최근 실내공기 중의 라돈기체의 농도를 저감하기 위하여 친환경 숯을 이용한 공기정화 필터 및 건축자재를 개발하기 위한 연구가 활발히 진행되고 있다. 본 연구에서는 종래의 입상 활성탄 필터에 비해 취급이 용이하고, 효율적으로 라돈을 흡착 및 제거할 수 있는 새로운 판재형 활성탄을 설계 및 제작하여 라돈 저감 성능을 평가하였다. 판재형 활성탄은 분말 활성탄과 폴리우레탄 폼을 일정한 비율로 혼합하고 믹싱 및 압착 공정을 통해 성형제품으로 제작하였으며, 다이아몬드 절삭을 통해 2 mm, 4 mm, 6 mm 두께로 각각 제작하였다. 제작된 활성탄 필터에 대한 물리적 특성을 분석하기 위해 비표면적과 휨 강도를 측정을 하였다. 또한, 실내 라돈기체의 저감성능을 평가하기 위해 3개의 아크릴 챔버를 이용하였으며, 일정한 공기유량에 대해 필터 통과 전과 후의 라돈 농도를 연속 측정하여 저감율을 평가하였다. 측정결과, 제작된 판재형 활성탄의 비표면적은 약 $1,008m^2/g$으로 종래의 활성탄과 유사한 값을 보였으며, 휨 파괴 하중은 435 N으로 석고보드보다 3배 이상 높은 강도를 가지는 것을 알 수 있었다. 끝으로, 실내 라돈기체의 저감은 활성탄의 두께가 증가함에 따라 저감효율이 증가하였으며, 6 mm 두께의 활성탄 필터에서 90 % 이상의 우수한 라돈제거율을 보였다. 이러한 결과로부터 본 연구에서 제작된 판재형 활성탄은 밀폐된 실내에서 라돈 기체의 농도를 감소시키기 위한 친환경 건축 재료 및 공기 정화 필터로 활용이 가능할 것으로 기대된다.

공공위락 시설의 실내 공기환경에 관한 연구 (A Study on the Indoor Air Quality of Public Entertainment Facilities.)

  • 정재국
    • 한국주거학회논문집
    • /
    • 제9권1호
    • /
    • pp.143-152
    • /
    • 1998
  • This study aims to suggest ventilation design data for Public Entertainment Facilities in relation to Indoor Air Quality. The concentration of indoor air pollution such as CO, CO2, RH, Radon, HCHO, TSP was investigate, and the reguired ventilation rate of Public Rooms was calculated. As resuits of this study, the following conclusion could be obtained. Field measurement of P.E.F reveals that the concentration of CO2 was mist polluted and higher than IAQ standard, while that of other pollutats did not exceed the standard. In underground the concentration of CO2 increased 1130ppm(2 persons) 2170ppm(4 persons) 1970ppm(6 persons). The CO2 pollution was serions problem in underground more than second floor, in only exhaust ventilation system more than exhaust and supply system.

  • PDF