• Title/Summary/Keyword: indoor radon

Search Result 157, Processing Time 0.025 seconds

Evaluation of Radon Concentration according to Mechanical Ventilation Systems in Apartments (공동주택 내의 기계환기 설비에 따른 라돈농도 평가)

  • Choi, Jiwon;Hong, Hyungjin;Lee, Jeongsub;Yoo, Juhee;Park, Boram;Kim, Gahyun;Yoon, Sungwon;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.4
    • /
    • pp.330-338
    • /
    • 2021
  • Background: This study was conducted to provide background information for the proper management of radon contamination in apartments using mechanical ventilation facilities in residential environments. Objectives: To this end, this study compared and evaluated changes in radon concentrations based on different operating intensities of mechanical ventilation with or without natural ventilation. Methods: For the continuous measurement of radon concentrations, an RAD7 instrument was installed in four apartments equipped with a ventilation system. The measurements were done for comparison of ventilation types and different ventilation intensities ("high", "middle", "low"). Results: The results confirmed that both mechanical and natural ventilation sufficiently reduced the radon concentration in the apartments. In particular, mechanical ventilation at "high" intensity was the most effective. Natural ventilation combined with mechanical ventilation and then natural ventilation alone were the second and the third most effective, respectively. Conclusions: When using ventilation to reduce indoor radon concentrations, it is most effective to operate mechanical ventilation ("high") or natural ventilation and mechanical ventilation at the same time. In cases where mechanical ventilation is available alone, it is recommended to operate it at a minimum of "middle" intensity.

Evaluation of Indoor Air Improvement of Matrix Using Activated clay as Adsorption Material (활성백토를 흡착재로 활용한 경화체의 실내 공기 개선 평가)

  • Jeong, Hyun-Su;Kim, Yeon-Ho;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.189-190
    • /
    • 2020
  • The importance of indoor air quality management has recently been highlighted due to environmental problems such as indoor air pollution. Among indoor air pollutants, carbon dioxide occurs in cooking, heating, burning, and causes forgetfulness, dementia and amnesia. Radon, which occurs in building materials, soil and ground, is a type 1 carcinogen that causes lung cancer in the body through breathing. These substances can be released from the room through ventilation, but there is a limit to reducing the amount of indoor activity due to reduced ventilation conditions due to increased indoor activity time. However, these substances can be removed from the gas by adsorption. The purpose of this study was to identify the properties of granular active and powdered active white soil and mix them to make cement-based active white soil adsorbent matrix for carbon dioxide, fine dust and radon gas adsorption, and to evaluate indoor air improvements according to the mixing scale. The results of the experiment showed that active carbon dioxide adsorption performance increased for carbon dioxide and radon as the exchange rate increased through physical adsorption. In particular, the higher the replacement rate of the granular active bag, the better adsorption performance was shown.

  • PDF

Distribution of $^{222}Rn$ Concentration in Seoul Subway Stations (서울지역 지하철역의 라돈농도 분포 특성)

  • Jeon, Jae-Sik;Kim, Dok-Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.588-595
    • /
    • 2006
  • Indoor radon($^{222}Rn$) concentrations of subway stations in Seoul area were measured to survey the environmental indoor radon levels and to identify sources of radon. The radon concentration of indoor air by method of long-term measuring with a-track detector were surveyed at 232 subway stations from 1998 to 2004. And the radon concentration in ground-water was measured with a method of alpha particle counting. To trace main source of radon, 8 out of 232 stations were selected and their radon concentrations in tunnel and on platform were analyzed. Total geometric mean and arithmetic mean of radon concentrations in all stations from 1998 to 2004 were $1.40{\pm}1.94pCi/L,\;1.65{\pm}1.07$ respectively. Geometric means of radon concentrations on platform and concourse were $1.54{\pm}1.96pCi/L,\;1.23{\pm}1.88pCi/L$ respectively, with higher concentration at the platform than at the concourse. The geological structure was significantly correlated to the indoor radon concentration in subway stations region. Radon concentrations of adjacent tunnel and ground-water of subway station was significantly correlated to the indoor radon concentration in subway stations. And There was a significant difference in radon concentration, depending on the depth levels in platform of subway stations(p<0.05).

A Study on the Distribution and Reduction Method of Indoor Radon Concentration in Daejeon Metropolitan City (대전광역시 주택 실내 라돈 농도 분포와 저감 공법 적용 연구)

  • Jang, Yong-Chul;Yang, Jae Hwan;Kim, Hongkyoung;Lee, Gain;Song, Hakyun;Kim, Byeonghwan;Kwon, Youngsun
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.5
    • /
    • pp.286-295
    • /
    • 2022
  • In this study, the concentration distribution of indoor radon in Daejeon Metropolitan City was investigated and the reduction efficiency was evaluated by applying the radon reduction methods. Based on the results of the National Institute of Environmental Research, indoor radon measurements were conducted on 24 selected houses, and the average value of District A was 261 Bq/m3, far exceeding the standard, and even in the same house, indoor radon concentration was affected by measurement point and time. In the case of eight houses that applied the soil venting method to reduce radon, the indoorradon level was significantly lowerthan the standard value, and the average reduction efficiency was also around 55%, indicating a good reduction effect. In addition, the average reduction efficiency was around 90% in the two houses that carried out the shielding method, showing the very excellent effect of the indoorradon reduction. Even if the same reduction method is applied when reducing radon, the reduction efficiency may vary depending on various factors such as the structure of the building, the frequency of ventilation, and the season, so it is necessary to accurately evaluate the effectiveness of the reduction method in the future. Based on this, it is necessary to establish indoor radon management measures in Daejeon Metropolitan City to reduce human harm caused by radon exposure.

Properties of Radon Absorbed Blast Furnace Slag Matrix using Palm Activated Carbon (야자활성탄을 활용한 라돈흡착형 고로슬래그 경화체의 특성)

  • Lee, Jae-Hoon;Park, Chae-Wool;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.160-161
    • /
    • 2019
  • Recently, a bed company's product has detected a certain level of radon or higher, making it a popular search word on portal sites. Because of this problem, people are becoming more interested in radon. The government plans to support the establishment of a radon alert system for households through a radon concentration survey of 10,000 households. The use of palm charcoal as an indoor finishing material will reduce the risk of lung cancer through radon reduction. The experiment used a method of replacing palm activated carbon with blast furnace slag, and the adsorption performance of radon tends to increase as the replacement rate of palm activated carbon increases.

  • PDF

Radon concentration measurement at general house in Pusan area (부산지역 일반주택에서의 라돈농도측정)

  • Im, In-Cheol
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.29-33
    • /
    • 2004
  • Until early 1980s we have lived without thinking that radon ruins our health. But, scientists knew truth that radon radioactive danger is bedeviling on indoor that we live for a long time. Specially, interest about effect that get in danger and injury for Radon and human body is inactive in our country. Recently, with awareness for Radon contamination, We inform about importance and danger of Radon in some station of the Seoul subway, indoor air of school facilities and We had interest with measure and manages. Usually, Radon gas emitted in base of building enters into indoor through building floor split windage back among radon or indoor air of radon daughter nucleus contamination is increased. Therefore, indoor radon concentration rises as there are a lot of windages between number pipe of top and bottom and base that enter crack from estrangement of the done building floor, underground to indoor. Thus, Radon enters into indoor through architecture resources water as well as, kitchen natural gas for choice etc., but more than about 85% from earth's crust emit. Danger and injury of health by Radon and Radon daughter nucleus that is indicated for cause of lung cancer incerases content of uranium of soil rises specially from inside pit of High area and a mine, cave, hermetical space with house. Safe sub-officer of radon concentration can not know and danger always exists large or small during. So, Important thing reduces danger of lung cancer by lowering concentration of Radon within house and building. Therefore, is thought that need general house Radon concentration measurement, measured Radon concentration monthly using Sintillator radon monitor. Study finding appeared high all underground market 1 year than the ground, and the winter appeared high than the summer. Specially, month that pass over 4pCi in house that United States Environmental Protection Agency advises appeared in underground, and appeared and know Radon exposure gravity by 4 months during 12 months. Therefore, Thinking that establishment and regulation of norm and preparation of reduction countermeasure about Radon are pressing feels, and inform result that measure Radon concentration.

  • PDF

Unsteady Analysis of Indoor Radon in Apartment Buildings Considering Finishing Materials and Ventilation (마감재 및 환기를 고려한 공동주택 실내 라돈 농도의 비정상 해석)

  • Cho, Hyun;Pang, Seung-Ki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.24-31
    • /
    • 2019
  • In this paper, we simulated a new apartment building by using radon emission test values from various building materials used as interior finishing materials. The simulations evaluated the radon concentration in the room according to the radon emissions and the ventilations for each type of finishing material (gypsum board, stone, tile and concrete). Overall concrete finish simulation case showed the highest concentration than the case using other materials due to the effect of wall area at the center of each room and the mean radon concentration at 1.5 m above the floor was slightly lower than the mean value at each center. In the case of the porch, pantry and bathroom, the radon concentration was high even when the same materials were used as in the other rooms.

Influence of Ventilation on the Subway Radon Level (환기에 의한 지하 역의 라돈농도 변화)

  • 박덕신;정우성;정병철
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.2
    • /
    • pp.62-67
    • /
    • 2000
  • Modern people stay at indoor places about 90% of a day. Radon-222 is a gas produced by the radioactive decay of the element radium. And, radon is one of the major indoor air pollutants. Radon moves into the underground space through various routes and is considered to cause lung cancer by hurting the lung tissues. In this study, we measured the subway radon level at 9 stations of 3 lines. According to test results, we can figure out the concentration of radon by lines, times, and measuring points. So, it was found that ventilation conditions are the most important factors in the subway air quality. Finally, we suggested effective and economic management methods of air pollution in the subway.

  • PDF

Assessment of radon potential in the areas covered with granite and gneiss in Korea

  • Je Hyun-Kuk;Chon Hyo-Taek
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.501-503
    • /
    • 2003
  • Soil-gas radon level and other atmospheric factors have been measured at residual soil profiles that overlie granite bedrock which consists of major geology in Korea for 6 months from November, 2000 to April, 2001. Seasonal variations of soil-gas radon concentration are generally of greater magnitude than day-to-day fluctuations. The highest radon concentrations of 5,131 pCi/L measured during winter season and the lowest radon concentrations of 107 pCi/L during spring season. Two study areas, Bongcheon-dong(granite bedrock) and Seongnam-Yongin(gneiss bedrock) were investigated to assess the radon potential according to their field survey and emanation tests. The mean values of radon decrease in sequentially from Suji-A(813 pCi/L)>Suji-B(757 pCi/L)>Bundang-B(691 pCi/L)>Bundang-A(643 pCi/L)>Bongcheon-dong(513 pCi/L). Estimated soil-gas radon potential using maximum radon emanation ratios of each study area decreases in the order of Bongcheondong(950 pCi/L)>Suji-B(524 pCi/L)>Bundang-A(437 pCi/)>Bundang-B(259 pCi/L)>Suji-A(230 pCi/L) areas. The values of indoor radon and its daughter product concentrations in Bongcheon-dong area show that indoor basement rooms in poor ventilation condition could be classified as extremely high radon risk location of more than 4 pCi/L Rn and 0.02 WL.

  • PDF

Evaluation of the Radon Contribution Rate in Apartments through Evaluation of the Radon Exhalation Rate from Building Materials (건축자재 라돈 방출률 평가를 통한 공동주택 내 라돈 기여율 평가)

  • Hong, Hyungjin;Choi, Jiwon;Yoon, Sungwon;Kim, Heechun;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.425-431
    • /
    • 2021
  • Background: This study evaluated the radon contribution rate through an evaluation of the exhalation rate of radon from building materials. Objectives: This study compared and evaluated the computation of the radon contribution rate based on each different exhalation rate in a building. Methods: The six demonstration houses that are the subject of this study are wall structures or Rahmen structures, and include demonstration houses similar to general residential environments and non-finishing houses with some walls exposed. Results: The highest exhalation rate was found at 62.98 Bq/m2 per day from the non-finishing floor, and the second highest exhalation rate was from stone materials at 58.76 Bq/m2 per day. Based on this result, investigating the contribution rate of building materials derived from building materials among indoor radon concentrations, house three was the highest at 81.7%, and house one was confirmed to be 33.96%. Conclusions: It can be judged that the effect of exposed concrete and stone is high, and that it is possible to reduce radon emitted from indoor building structures by controlling the indoor materials.