• Title/Summary/Keyword: indoor product

Search Result 108, Processing Time 0.028 seconds

The metal corrosion caused by museum indoor air pollutants (박물관 실내 대기오염물질에 의한 금속 부식 영향)

  • Kang, Dai-Ill
    • Journal of Conservation Science
    • /
    • v.22
    • /
    • pp.5-14
    • /
    • 2008
  • The effect of air pollutants coming from internal museum materials such as wood-based products and cements on metal corrosion have been investigated. The Oddy test and the Chamber test was employed as a corrosion test. The metal pieces after the Oddy test had different corrosion types caused by the internal museum materials. The most effective wood based product was 18T HS(E0) and 9mm plywood(F0,E0). Iron(Fe) and copper(Cu) also bronze of the Chamber test had corrosion caused by Formic acid, Acetic acid, and Acetaldehyde. The packing materials in high humidity had caused more corrosion on the surface of the metal pieces than in low humidity.

  • PDF

Assessment of radon potential in the areas covered with granite and gneiss in Korea

  • Je Hyun-Kuk;Chon Hyo-Taek
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.501-503
    • /
    • 2003
  • Soil-gas radon level and other atmospheric factors have been measured at residual soil profiles that overlie granite bedrock which consists of major geology in Korea for 6 months from November, 2000 to April, 2001. Seasonal variations of soil-gas radon concentration are generally of greater magnitude than day-to-day fluctuations. The highest radon concentrations of 5,131 pCi/L measured during winter season and the lowest radon concentrations of 107 pCi/L during spring season. Two study areas, Bongcheon-dong(granite bedrock) and Seongnam-Yongin(gneiss bedrock) were investigated to assess the radon potential according to their field survey and emanation tests. The mean values of radon decrease in sequentially from Suji-A(813 pCi/L)>Suji-B(757 pCi/L)>Bundang-B(691 pCi/L)>Bundang-A(643 pCi/L)>Bongcheon-dong(513 pCi/L). Estimated soil-gas radon potential using maximum radon emanation ratios of each study area decreases in the order of Bongcheondong(950 pCi/L)>Suji-B(524 pCi/L)>Bundang-A(437 pCi/)>Bundang-B(259 pCi/L)>Suji-A(230 pCi/L) areas. The values of indoor radon and its daughter product concentrations in Bongcheon-dong area show that indoor basement rooms in poor ventilation condition could be classified as extremely high radon risk location of more than 4 pCi/L Rn and 0.02 WL.

  • PDF

Characteristics of Interior Space Shown In Public Space of Andree Putman's Design Hotels (안드레 푸트만의 디자인 호텔 공용공간에 나타난 실내공간 특성)

  • Noh, Hyun-Kyoung;Kim, Moon-Duck
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.1
    • /
    • pp.72-81
    • /
    • 2015
  • The change towards meeting diverse customer needs has started to affect the hotel industry as well. Design hotels emerged as customers demanded differentiated lodging experiences they could not fulfill at franchise hotels which were uniform in style everywhere in the world. Design hotels are meant to provide a new concept of space through unique design sensibility and work of designers, which highlighted the role of interior design. This research analyzes the characteristics of indoor space expressed in design hotel common spaces by the French designer Andree Putman, also known as the founder of boutique hotels and the concept of design hotels. As the original founder of the concept of design hotels, Putman's scope of work stretches wide, from interior design to product design. She is also one of the few French designers with a modernist inclination. The research runs a review on previous literature, characteristics of design hotels according to design tendency, and the association with characteristics of indoor space designed by Andree Putman, followed by case analyses extracted by analyses on design characteristics of common spaces she has designed. The analysis reveals that she creates comfortable yet elegant space, using contrast and fusion arising from negotiation of design styles to interpret space, the sense of spatial balance and understated expression of order through symmetrical structures, diverse creation of space through geometric structuring, highlighting indoor space by utilizing lights as objects, and the heterogeneous harmony achieved by contrasting juxtaposition, and understated formativeness. It is expected that study results would be utilized as methods of new designs of interior space in design hotels.

A Study on a 3-Dimensional Positioning System over Indoor Wireless Environments (실내 무선 환경에서 3차원 위치 추적 시스템에 관한 연구)

  • Kang, Byeong-Gwon;Choi, Sung-Ja;Kim, Gui-Jung;Park, Yong-Seo
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.273-279
    • /
    • 2014
  • In this paper, we propose a novel algorithm for three dimensional positioning system and implement a system over indoor wireless channel. A commercial modules are used for mobile and fixed nodes which are product of German company Nanotron Co. This module adopts chirp spread spreading scheme as modulation method to improve the ranging resolution and the module satisfies the IEEE standard 802.15.4a. The distance computation is based on received signal strength(RSS) levels and trilateration method. A testbed was set up to measure and compare the positioning estimation error of the proposed algorithm. The experiments results showed that the accuracy of location estimation was sufficiently good as much as 1m distance error in a wireless environment in an office building.

The Design of the Motor Bracket for Reduction of Structure- Borne Noise in Package Air-Conditioner (에어컨의 구조 소음 저감을 위한 실내기 모터 브라켓의 설계)

  • Sim Hyoun-Jin;Lee Sung-Jin;Kang Tae-Ho;Lee Jung-Yoon;Oh Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.2 s.245
    • /
    • pp.202-209
    • /
    • 2006
  • As the economic power is improved and the customer's demand is hard to please, the noise and vibration is the most important yardstick that can determine the quality of the product. Especially, as the airconditioner's demand increase suddenly, the product of quality and the noise is becoming a decisive factor of determining whether purchase the product or not. Therefore, every manufactory is investing a lot of money and research to cut down the unpleasantness induced from noise and vibration. And they are emphasizing their product's difference by advertising a silence very actively. With these reason, the demand of a silent indoor air-conditioner is the essential research filed when the product is develop(:d. In this study, the noise and vibration is visualized in the space and frequency domain by using experimental methods such as operational deflection shape (ODS), modal testing and sound intensity. Also the location of noise source and its characteristic is analyzed in an acoustical point of view to reduce the structure borne noise that come from the fan motor, and the pertinent control method is suggested. Furthermore, the most suitable shape of the motor bracket is suggested by applying FEM and DOE (Design of experiments) in the noise and vibration point a view.

The Variation of Indoor Air Quality in Nursing Home

  • Ji, Dong-Ha;Choi, Mi-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.1
    • /
    • pp.117-124
    • /
    • 2020
  • In this paper, we proposed a plan to maintain comfortable indoor air quality in nursing homes by suggesting ways to reduce items temporarily exceeding the reference values through real-time concentration variation analysis of indoor air quality. Five items including PM10, CO2, CO, VOC, and Radon are measured at nursing homes in spring (April) and autumn (September) was carried out and all of the measured items were analyzed to satisfy the criteria set by the Indoor Air Quality Control Act. As a result of the analysis of the real-time concentration change, the concentration of CO2 was close to the reference value based on the number of occupants in the sick room. Due to the disinfectant (alcohol) used to disinfect and the auxiliary tools (adhesive) used in the operation of the program such as making and coloring, it was analyzed to temporarily exceed the standard value in the hall. In conclusion, it is possible to provide pleasant indoor air quality and contribute to securing the nursing home's competitiveness if periodic ventilation, natural disinfectant and eco-friendly product are used in consideration of the thermal environment.

Assessment of VOCs Emission Characteristics from Building Materials such as Wall Paper, Paints, and Adhesives Using Small Chamber Method (소형챔버법을 이용한 건축자재 중 벽지, 페인트 및 접착제의 VOCs 방출특성 평가)

  • Lee Suk-Jo;Jang Seong-Ki;Cho Yong-Sung;Jung Kyung- Mi;Jeong Gi-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.191-204
    • /
    • 2005
  • Building and furnishing materials and consumer product are important sources of volatile organic compounds(VOCs) and other aldehydes in the indoor environment. Some available evidence indicates that VOCs can cause adverse health effects to the building occupants and contribute to some of the symptoms of what we call, 'Sick House Syndrome' in Korea. The aims of this study were to evaluate the efficiency of emission system and to investigate comparison of the emission characteristics of different building materials such as wall-papers, paints, and adhesives. The emission of VOCs from building materials were determined in the small chambers defining the temperature, relative humidity, and ventilation rate in this study. VOCs were sampled for 20 minutes using Tenax-TA tubes and analysed by GC-MS with thermal desorption. The stability of conditions for temperature and relative humidity in this small chamber system showed that the fluctuation of temperature was between 25.4$\pm$0.3$^{\circ}C$ and that of relative humidity was 50.2$\pm$0.6$\%$ under the airflow rate of 167 mL/min. The emission tests from building materials resulted in TVOC emission rates of 0.011 $\~$ 3.108 mg/m$^{2}$h after 7 days. The general wall-papers emitted toluene abundantly and the natural wall-papers mainly emitted n-butanol and a minor amount of alkanes compound such as n -tetradecane. The remainder consisted of toluene, m,p -xylene, and styrene. The paints mainly emitted toluene and the adhesives mainly emitted chloroform as well as toluene. As a result, this study is expected to suggest meaningful data for future studies in exposure control through selecting healthy building materials and for the establishment of guidelines for various building materials in Korea.

Distribution and Risk Assessment of Bisphenol-A in Tap Water from Rehabilitated Indoor Water Service Pipe (갱생 옥내급수관 수돗물에서 비스페놀-A 분포 및 위해성 평가)

  • Jeong, Gwanjo;Son, Boyoung;Lee, Inja;Ahn, Chihwa;Kim, Junil;Moon, Boram;Lee, Suwon;Ahn, Jaechan;Kim, Bogsoon;Chung, Deukmo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.371-376
    • /
    • 2016
  • In this study, the survey of bisphenol-A in indoor water service pipes rehabilitated with epoxy resin was conducted and the risk assessment was done to investigate the effect on the human health to drink tap water. Bisphenol-A in raw water was detected in a range of 50~118 ng/L in all samples, where the limit of quantification was 10 ng/L. This is caused by inflow of the sewage effluent or the tributaries of the surrounding area containing bisphenol-A. Bisphenol-A was not detected in finished water after the advanced water treatment process. It was achieved by its removal from the processes of flocculation-precipitation and oxidation of ozone and chlorine and by being changed to other by-product materials. For the indoor water service pipe, bisphenol-A was not detected in all cases which was not coated with epoxy resin. However, when epoxy resin is lined within the indoor water service pipe, bisphenol-A was identified at maximum level of 521 ng/L and was detected above the limit of quantitation at 68 percentages of all samples. The Hazard Quotient (HQ) at the maximum level (521 ng/L) of the detected bisphenol-A is 0.004, which is less than the reference value of 0.1 for the tap water intake. Therefore, it is considered that the detected levels of bisphenol-A in this study would be safe to drink tap water.

Design of Integrated Process-Based Model for Large Assembly Blocks Considering Resource Constraints in Shipbuilding (자원제약을 고려한 조선 대조립 공정의 통합 프로세스 기반 모델 설계)

  • Jeong, Eunsun;Jeong, Dongsu;Seo, Yoonho
    • Journal of the Korea Society for Simulation
    • /
    • v.28 no.2
    • /
    • pp.107-117
    • /
    • 2019
  • Because shipbuilding is single-product production with limited resources, production management technology is essential to manage the resources effectively and maximize the productivity of ship-process. Therefore, many shipbuilding companies are conducting research on ship production plan and process considering various constraints in the field by applying modeling and simulation. However, it is difficult to provide accurate production plan on sudden schedule and process changes, and to understand the interconnectivity between the processes that produce blocks in existing research. In addition, there are many differences between the production planning and field planning because detailed processes and quantity of blocks can not be considered. In this research, we propose the integrated process-based modeling method considering process-operation sequences, BOM(Bill of materials) and resource constraints of all the scheduled blocks in the indoor system. Through the integrated process-based model, it is easy for the user to grasp the assembly relationship, workspace and preliminary relationship of assembly process between the blocks in indoor system. Also, it is possible to obtain the overall production plan that maximizes resource efficiency without the separate simulation and resource modeling procedures because resource balancing that considers the amount of resource quantity shared in the indoor system is carried out.

An Investigation of Consumer Product Co-use Patterns - Focusing on air-fresheners and deodorizer - (생활화학제품 동시 사용현황 조사 - 방향제와 탈취제를 중심으로 -)

  • Lee, Daeyeop;Lim, Hyunwoo;Kim, Joo-Hyon;Kim, Taksoo;Hwang, Moonyoung;Seok, Kwangseol;Seo, Jungkwan
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.275-282
    • /
    • 2018
  • Objective: Since certain chemicals are widely applied in a variety of consumer products, exposure via simultaneous use of multiple consumer products can put human health at risk. For this reason, use patterns of consumer products are an important factor inhuman health risk assessment. The aim of this study is to investigate co-use patterns of air-fresheners and deodorizers in Korea in order to estimate potential cumulative exposure. Methods: To collect the information on use patterns of air-fresheners and deodorizers, ten air-fresheners and 14 deodorizers were selected. A total of 3,000 participants were recruited and asked through on line questionnaires whether they had simultaneously used the selected air-fresheners and deodorant products in their daily lives. Results: Among the 3,000 participants, 45.6% had used more than two air fresheners and 46.3% used more than two deodorizers. The most common types of air fresheners used concurrently include liquid and candle types for indoor environments, while those of deodorizers were fabric trigger sprays and refrigerator gels. In addition, 73.7% used more than two products without product categories. Fabric trigger sprays were contained in all of the high-ranking product combinations. Conclusions: This study showed that many consumers concurrently used air-fresheners and deodorizers in their daily routines. For accurate exposure assessment, co-use patterns of consumer products should be further investigated.