• Title/Summary/Keyword: indoor humidity

Search Result 490, Processing Time 0.025 seconds

Indoor air pollution in ger, a traditional type of residence in Mongolia (몽골 울란바토르 시 전통 주거공간의 실내공기 오염 기초조사)

  • Lee, Boram;Chimeddulam, Dalaijamts;Jargalsaikhan, Khishigt;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.2
    • /
    • pp.118-125
    • /
    • 2016
  • Objectives: The traditional type of residence in used in Mongolia, called a ger, is an important residential form and applies coal combustion for cooking and heating. The combustion of coal in ger is the major source of indoor air pollution. The purposes of this study were to measure indoor air pollution in ger and determine the effect of cooking and heating activities. Methods: Indoor temperature, relative humidity, particulate matter less than $2.5{\mu}m$ ($PM_{2.5}$) and black carbon (BC) were continuously measured for 24 hours in eight ger. The measurements were conducted in January or February 2015. Heavy metals in $PM_{2.5}$ filter samples were analyzed by ICP-MS. Results: Average indoor temperature and relative humidity were $19.6{\pm}4.6^{\circ}C$ and $21.4{\pm}5.2%$, respectively. The average indoor $PM_{2.5}$ concentration in the eight ger was $119.8{\mu}g/m^3$ and ranged from 69.4 to $202.7{\mu}g/m^3$. The peak concentrations of $PM_{2.5}$ and BC during cooking and heating periods were several times higher than the 24- hour average concentration. Conclusion: The major contributor to indoor $PM_{2.5}$ and BC concentrations in the ger was coal combustion for cooking and heating.

Present Condition of Indoor Thermal and Air Environment by Cooling in School Classrooms (학교교실의 냉방시 실내열.공기환경 실태)

  • Choi, Yoon-Jung;Jeong, Youn-Hong;Lee, Seon-A;Kim, Hye-Kyeong;Hwang, Jin-A
    • Journal of the Korean housing association
    • /
    • v.18 no.4
    • /
    • pp.49-58
    • /
    • 2007
  • The purpose of this study were to make clear the present condition of indoor thermal and air environment by cooling in school classrooms and to analyze the relation of the living conditions with indoor environment. The measurements on physical elements and observations on living conditions were carried out in 6 classrooms of 3 middle or high schools. Measuring elements were indoor temperature, relative humidity, PM10 and $CO_2$ concentration. As results, the averages of indoor temperature each classrooms were $24.9{\sim}26.6^{\circ}C$. Most of classrooms were lower than the Maintenance standard $(26{\sim}28^{\circ}C)$ of School Health Law. The means of relative humidity were $51.3{\sim}72%$, all classrooms were ranged within the standard $(30{\sim}80%)$. The means of PM10 concentration were $3.5{\sim}23.1{\mu}g/m^3$, all classrooms were kept within the standard $(100{\mu}g/m^3)$. The means of $CO_2$ concentration were $1218.7{\sim}4705.4ppm$, all classrooms were exceed the standard (1,000ppm). The results of analysis on relations of living conditions with the physical elements are as follow; the air conditioner set of temperature, windows and doors opening elapsed time, the number of students in classrooms and activities of students had certain effect on indoor environment.

Effect of Scindapsus aureus and Syngonium podophyllum on the Improvement in Indoor Humidity by a Difference of Hydoroculture Volume Ratio and Pot Media (하이드로컬쳐 부피비와 화분용토에 따른 스킨답서스, 싱고늄의 실내습도 개선효과)

  • Ju, Jin-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.4
    • /
    • pp.94-99
    • /
    • 2009
  • The purpose of this study was to utilize hydroculture by the vital means of the improvement of indoor relative humidity. This experiment employed a search of the effect of Scindapsus aureus and Syngonium podophyllum that are generalized for hydroculture foliage plant by a difference of volume ratio, pot media and plants species. In the case of Scindapsus aureus, relative humidity was high for growth chamber in which plants presented as opposed to control growth chambers in which there were no plants. Although relative humidity was 25% in control chamber, there was an increase of 40% at a 2% volume ratio, 45% at a 3% volume ratio and 50% at a 5% volume ratio. The relative humidity of Syngonium podophyllum was 40% at a 2% volume ratio, 44% at a 3% volume ratio and 46% at a 5% volume ratio, while the control treatment was 25% relative humidity in hydroculture. Both the control treatment and hydroball pot in a hydroball container were high at first. As time progressed, artificial soil pots in water containers was similar when housed within the control chamber by about 45% relative humidity. Hydroball pots in water container had about 30% relative humidity. Ardisia pusilla of hydroball poIt in hydroball container had about 38% relative humidity.

Evaluation of Indoor Thermal Environment of Houses using for heating in winter (도시가스 사용 주택의 동절기 실내온열환경 평가)

  • Park, Seok-Bong;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.125-131
    • /
    • 2005
  • This study identified satisfaction with gas heating and indoor thermal environment, targeting houses using gases for heating. 1) Thermal environment is relatively satisfactory except that indoor humidity is low. 2) A question that indoor temperature has to be decreased for saving energy was given and about two thirds of the respondents answered that temperature has to be lowered. When they were asked how to save energy 57% answered that they put on more clothes and 27% answered that they lower indoor temperature If consistent promotion on energy saving is implementer it's believed that energy can be effectively saved. 3) People wear simple clothes when they stay indoor because they think it is comfortable. However, for energy saving. they gave to wear warm clothes though they stay indoor.

An Experimental Study on the Temperature and Humidity Evaluation in the Summer and Winter Season of the Korean Traditional Houses in Chonnam Province (전남지방 전통주택 하절기와 동절기의 온습도 평가에 관한 실험적 연구)

  • Lee, Tai-Kang;Choi, Eun-Seok;Kim, Hang;Kim, Hyung-Ryul;Gi, No-Gab;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.57-62
    • /
    • 2006
  • Korean Traditional houses has been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various passive system of using natural materials, considering micro climate, building lay out, and these system are more natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed control performance of outdoor environment of five Korean traditional houses during the summer and winter. These houses are varied with lay out and floor plan to reflect the way of control for environmental condition, surveyed the reverberation time and sound level difference between rooms of the main living room and other main floored room, master room and kitchen. Especially air temperature and humidity have been measured simultaneously in each rooms to compare with outdoor condition. As a result, the variation of air temperature and humidity of most rooms are considerably static while condition of outdoors are much varied, it is showed that indoor climate has been controled with traditional soiled walls.

A Comparative Functionality Evaluation of Paulownia Wood Storage Boxes and Acid-free Archival Boxes to Store the Annals of Joseon Dynasty - Indoor and Outdoor Temperature and Relative Humidity Controls, and Heat Release Rate -

  • Park, Hae Jin;Kim, Seong Eun;Lee, Jin Kyung;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.38 no.1
    • /
    • pp.72-79
    • /
    • 2022
  • A paulownia wood has been widely used with various advantages as its low weight, permeability, convenient workability and aesthetic patterns for a long time. However, the related empirical researches and simultaneous evaluations of functionality are insufficient compared with acid-free archival boxes for now. In this study, the indoor and outdoor temperature and relative humidity control and heat release rate were evaluated under the controlled and uncontrolled circumstance in 2018. The paulownia wood storage box showed superior control effect of relative humidity than the acid-free archival box in constantly uncontrolled environment. Also, the possibility of the flame diffusion from the surface of the materials was higher for the paulownia materials, and the acid-free archival box showed more dangerous patterns in the early stages of the fire.

A Study on Thermal Comfort Comparison between Tencel and Polyester Indoor Cothing

  • Chung, Sham-Ho;Yoo, Eun-Ok;Hwang, Soo-Kyung;Lee, Han-Seop
    • International Journal of Costume and Fashion
    • /
    • v.9 no.1
    • /
    • pp.34-43
    • /
    • 2009
  • This study compared the thermal comfort of indoor clothing from Tencel material that is getting higher in demand due to being eco-friendly with superior wettability, with that from Polyester material that despite being most widely used for indoor clothing, rapidly discharges body sweat due to low wettability. The experiments were performed in the two manners, objective evaluation under the conditions of an artificial climate chamber and subjective evaluation of wearing the given clothes at home followed by filling in the questionnaire. Subjects were 8 healthy elderly women in their 60's who spend majority of their time at home rather than in social activities, and comparison was made on skin temperature and humidity inside clothing at exercise and relaxation states under early summer environment. Based on these results, wearing Tencel material clothing maintained cooler temperatures under warm environment rather than when wearing Polyester material clothing, thus enabling activities under more comfortable state. Regarding humidity inside clothing, parts with twofold clothing did not show difference between Tencel and Polyester, but the onefold arm showed lower when wearing Tencel. With this results, Tencel is regarded as more comfortable and nicer than Polyester.

Studying indoor contaminant value according to vary ventilation and humidity, when operating bake-out on a new apartment (신축 공동주택 베이크 아웃시 환기.습도 변화에 따른 실내오염물질 저감비교)

  • Cho, Yeon-Hyo;Shin, Sung-Woo;Lee, Ji-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.702-707
    • /
    • 2008
  • Improving quality of life and wellbeing of the residential environment and increased interests and importance is growing confidentiality, insulation, high-rise due to a lack of ventilation and indoor air pollution. Several human diseases caused tremendously due to the indoor air which consists of formaldehyde, radon, pollutants such as volatile substances that is called the phenomenon of a new house syndrome. It has become a world-wide issue that the United States, Japan and several other countries of Europe are showing more interests. Furthermore, a lot of damages caused by the syndrome occurs in the new house should be resolved by somehow is urgent. Thus, this study would like to propose the measures based on the whether condition and the way of heating in korea against a new house syndrome via analysis of indoor contaminant Reduction comparison according to vary ventilation and humidity when operating bake-out on a new apartment.

  • PDF

Destruction of Volatile Organic Compounds Using Photocatalyst-Coated Construction Materials (건축자재의 산화티타늄 코팅을 통한 휘발성 유기화합물 분해)

  • Jo Wan-Kuen;Chun Hee-Dong
    • Journal of Environmental Science International
    • /
    • v.14 no.8
    • /
    • pp.785-792
    • /
    • 2005
  • In order to reduce roadside and indoor air pollution for volatile organic compounds VOC), it may be necessary to apply photocatalyst-coated construction materials. This study evaluated the technical feasibility of the application of $TiO_2$ photocatalysis for the removal of VOC present in roadside or indoor air. The photocatalytic removal of five target VOC was investigated: benzene, toluene, ethyl benzene and o,m,p-xylenes. Variables tested for the current study included ultraviolet(UV) light intensity coating materials, relative humidity (RH), and input concentrations. Prior to performing the parameter tests, adsorption of VOC onto the current experiment was surveyed, and no adsorption was observed. Stronger UV intensity provided higher photocatalytic destruction(PCD) efficiency of the target compounds. For higher humidity, higher PCD efficiency was observed. The PCD efficiency depended on coating material. Contrary to certain previous findings, lower PCD efficiencies were observed for the experimental condition of higher input concentrations. The current findings suggested that the four parameters tested in the present study should be considered for the application of photocatalyst-coated construction materials in cleaning VOC of roadside or indoor air.

A Study on the Indoor Comfort Control By Smart Comfort Algorithm (스마트 쾌적 알고리즘을 적용한 실내 쾌적 제어에 대한 연구)

  • Yoon, Seok-Am;Lee, Jeong-Il
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.603-609
    • /
    • 2015
  • Thermal comfort is one of the fundamental aspects of indoor environmental quality and it is strongly related to occupant satisfaction and energy used in building. In this paper, we proposes smart comfort algorithm that save energy and provide a pleasant and comfortable environment for workers by the indoor comfort conditions(Predictive Mean Vote) detection and controlling the temperature and humidity, air flow. Simulation results, heating and cooling control of the thermal comfort control can be compared with the existing general air conditioners reduces the power of 0.5kW and indoor comfort can be maintained. Also, It showed a 49.2% improvement in the light by lighting control algorithm.