• 제목/요약/키워드: indoor humidity

검색결과 490건 처리시간 0.037초

신조 운항실습선의 봄철 실내 온열환경 실측평가 (A Measurement and Evaluation on the Indoor Thermal Conditions in Spring of a New Training ship)

  • 신동걸;이진욱;이형기;박윤철;황광일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권8호
    • /
    • pp.939-946
    • /
    • 2007
  • The purpose of this study is to measure and analyze the ship's indoor thermal conditions and also to integrate experimental database of those, supplied and controlled by ship's HVAC. On this study, temperature, humidity and air volume of 6 different needs' cabin are measured on a newly-launched training ship during 2nd through 5th of April, 2007. Followings are the results of this study. (1)Because only partial loads are needed in spring season, the air volume from diffusers are measured as below 20%. (2)The temperatures are ranged between $20{\sim}25^{\circ}C$ and those are within comfort temperature range proposed by AHREA. (3)But humidities in cabins are very low and it could be the reason of a cold and/or a skin disease. (4)From the student cabins' measurements which have different supply diffuser(s), it is clear that the design is suitable for this case. (5)Because of low humidity, only 16.1% among the measured data are satisfied with the comfort standard range proposed by ASHREA. To improve the predictability and the comfort, HVAC should maintain the humidity as $40{\sim}60%$.

외기 온습도 조건에 따른 폐열회수 환기장치의 열전달 특성 및 불확실성에 관한 연구 (A Study on Heat Transfer Characteristics and Uncertainty of Heat Recovery Ventilator for Various Outdoor Temperature/Humidity Conditions)

  • 한화택;추연복
    • 설비공학논문집
    • /
    • 제20권9호
    • /
    • pp.608-613
    • /
    • 2008
  • The purpose of the present paper is to investigate the effect of outdoor weather conditions on the performance of a heat recovery ventilator. Experiments have been performed by varying outdoor temperature/humidity conditions with the indoor conditions fixed at the standard conditions by KARSE. Results indicate humidity efficiency shows larger uncertainties than temperature efficiency in general. With the heat generation by an internal fan removed, the modified temperature efficiency remains almost constant regardless of the indoor-outdoor temperature difference. The enthalpy efficiency can have very large or negative values in case the outdoor conditions are in the vicinity of the indoor enthalpy line. The direction of heat flow, in such a case, can be opposite to that of moisture flow between two air streams. Discussions are included about various interesting features of the psychrometric processes taking place in a heat recovery ventilator.

저온 대기압 플라즈마의 실내공기 중 곰팡이 생장억제 효과 (Inactivation of Indoor Airborne Fungi Using Cold Atmospheric Pressure Plasma)

  • 백남원;허성민;이일영
    • 한국산업보건학회지
    • /
    • 제29권3호
    • /
    • pp.351-357
    • /
    • 2019
  • Objectives: The objectives of this study were to investigate fungal contamination in a 31-year old university building in Seoul, Korea, and to study the inactivation of fungi using cold atmospheric pressure plasma(CAP). Methods: To investigate the fungal contamination in a university building, air samples were collected from five locations in the building, including two study rooms, a storage room, a laboratory, and a basement. The sampling was performed in a dry season(February to April) and in a wet season(July). To study the inactivation efficacy of fungi by CAP, airborne fungal concentrations were measured before and after the operation of the CAP generator. Results: Humidity was an important factor affecting fungal growth. The airborne fungal concentrations determined in the wet season(July) were significantly higher than those determined in the dry season(February to April). In the basement, the values determined in the dry and wet season were 319 and $3,403CFU/m^3$, respectively. The inactivation efficiency of fungi by CAP was 83-90% over five to nine days of operation. Conclusions: The university building was highly contaminated by airborne fungi, especially in summer. It is concluded that humidity is an important factor affecting fungal growth and CAP is a highly useful technique for inactivation of indoor airborne fungi.

서울 일부지역(一部地域)의 실내(室內) Radon 오염도(汚染度) 조사(調査) 연구(硏究)( I ) (A Study on Indoor Radon Concentrations in Seoul( I ))

  • 김창균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권1호
    • /
    • pp.51-54
    • /
    • 1996
  • This study was conducted to find out the indoor radon concentrations from Jan. 1, to Dec. 31, 1995 in Seoul, and the following results were achieved; 1. The average concentration of indoor radon ranged from $0.51pCi/\ell$ to $0.78pCi/\ell$. 2. The correlation coefficients(r) of radon concentration and indoor meteorological conditions were as follows; 1) temperature : r=0.11 2) atmospheric pressure : r= -0.01 3) humidity : r=0.227.

  • PDF

Assessment of indoor air micro-flora in selected schools

  • Katiyar, Vinita
    • Advances in environmental research
    • /
    • 제2권1호
    • /
    • pp.61-80
    • /
    • 2013
  • Quantification of viable forms of microbial community (bacteria and fungi) using culture-dependent methods was done in order to characterize the indoor air quality (IAQ). Role of those factors, which may influence the concentration of viable counts of bacteria and fungi, like ventilation, occupancy, outdoor concentration and environmental parameters (temperature and relative humidity) were also determined. Volumetric-infiltration sampling technique was employed to collect air samples both inside and outside the schools. As regard of measurements of airborne viable culturable microflora of schools during one academic year, the level of TVMCs in school buildings was ranged between 803-5368 cfu/$m^3$. Viable counts of bacteria (VBCs) were constituted 63.7% of the mean total viable microbial counts where as viable counts of fungi (VFCs) formed 36.3% of the total. Mean a total viable microbial count (TVMCs) in three schools was 2491 cfu/$m^3$. Outdoor level of TVMCs was varied from 736-5855 cfu/$m^3$. Maximum and minimum VBCs were 3678-286 cfu/m3 respectively. Culturable fungal counts were ranged from 268-2089 cfu/$m^3$ in three schools. Significant positive correlation (p < 0.01) was indicated that indoor concentration of viable community reliant upon outdoor concentration. Temperature seemed to have a large effect (p < 0.05, p < 0.01) on the concentration of viable culturable microbial community rather than relative humidity. Consistent with the analysis and findings, the concentration of viable cultural counts of bacteria and fungi found indoors, were of several orders of magnitude, depending upon the potential of local, spatial and temporal factors, IO ratio appeared as a crucial indicator to identify the source of microbial contaminants.

철도차량 객실 온습도 USN 모니터링 기술 (Temperature and Humidity Monitoring Using Ubiquitous Senor Network in Railway Cabin)

  • 권순박;조영민;박덕신;박은영;김세영;정미영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.948-951
    • /
    • 2008
  • Ubiquitous sensor network (USN) based on ZigBee communication protocol has been used in various application fields, such as home-network, intelligent building and machine, logistics, environmental monitoring, military field, security field and etc. The ZigBee is targeted at radio-frequency application that require a low data rate, long battery life and secure network. Especially, the USN system can be applied efficiently to building-indoor where the complex geometry is adopted. In this study, all 90 points of railway cabin indoor were monitored for temperature and humidity using USN technology. All sensors were pre/post-calibrated and the temperature/humidity change were analyzed in a railway cabin in real-time. The results would be useful to develop the cabin heating, ventilating and air conditing (HVAC) system to meet all passengers' thermal comfort regardless of their seat position.

  • PDF

황토벽돌벽 주택의 실내온열환경에 관한 연구 (A Study on the Indoor Thermal Environment of House Using Earth Brick Wall)

  • 이재윤
    • 한국주거학회논문집
    • /
    • 제15권1호
    • /
    • pp.25-32
    • /
    • 2004
  • The purpose of this study is to understand the indoor thermal environment in the earth brick wall building what is called a ecological Architecture. To investigate thermal performances of the earth brick walls, it measured indoor and outdoor air temperature, relative humidity, globe temperature and PMV in reference house. The result of this study were summarized as the followings; 1) When the outdoor average air temperature was $21.8^{\circ}$, livingroom was $24.9^{\circ}$, kitchen was $25.1^{\circ}$ and 2nd floor room was $25.6^{\circ}$ at 150 cm height from the floor. 2) Although the average outdoor relative humidity was 78%, the livingroom was 67.5%. 3) As the air temperature difference between at the top and bottom was $0.6^{\circ}$ in living room, this value was below 1 % of PPD by ASHRAE Handbook. 4) Predicted Mean Vote(PMV) by ISO-7730 was +0.41.

쾌적한 실내 환경을 조성하기 위한 아두이노의 온도와 습도를 이용한 퍼지 기반의 팬 제어 연구 (Fuzzy-based Fan Control using Arduino's Temperature and Humidity for Comfortable Indoor Environment)

  • 김재홍;김재우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 추계학술대회
    • /
    • pp.389-392
    • /
    • 2018
  • 본 논문에서는 덥고 습한 실내에서 온도,습도에 의해 움직이는 팬을 적절하게 조절하여 쾌적 환경을 조성하고자 한다. 이를 위해 실내 온도와 습도를 이용한 퍼지 기반의 팬 제어를 제안하고, 이를 아두이노를 이용하여 실내 온, 습도 등의 환경 데이터 수집하고, 블루투스 통신으로 전달하고, 퍼지 로직에 따라 팬의 동작 시간을 조절한다. 먼저 이를 위해 아두이노 하드웨어에 온도 습도 센서를 연결하고, 컴퓨터에 있는 아두이노 프로그램을 이용해서 소스코드를 작성하고 아두이노에 코딩한다. 그뒤 아두이노로부터 온도와 습도 등의 환경 데이터 수집하고 나서 얻은 환경 데이터를 아두이노 제어 모듈에 블루투스 통신으로 전달한다. 전달 받은 환경데이터를 퍼지 로직을 이용하여 온도 습도 등 환경 데이터에 따라 팬이 동작하는 시간을 조절한다. 이 과정이 끝나면 팬이 온도,습도에 따라 동작하여 환경을 쾌적하게 조성 한다. 이 연구를 통해 아두이노는 더욱 간단하고 일반인들도 쉽게 사용이 가능하고, 아두이노 하드웨어, 데이터 수집, 퍼지 로직, 제어 등을 이용하여 실생활에 활용할 수 있다.

  • PDF

실내공기질 개선 시스템의 서버 구성 방식에 따른 응답 시간의 차이 비교 (Comparison of the Difference in Response Time According to the Server Configuration Type of the Indoor Air Quality Improvement System)

  • 국중진
    • 반도체디스플레이기술학회지
    • /
    • 제22권1호
    • /
    • pp.59-63
    • /
    • 2023
  • Various devices have been emerging as a means of measuring indoor air quality, and among them, there are devices that support real-time remote monitoring through IoT technology and a cloud environment. To improve indoor air quality, based on the results determined by measuring devices, air purifiers or ventilation systems may need to be operated, and temperature and humidity control may be required. In this paper, we propose a design of indoor air quality measuring devices required for indoor air quality evaluation, and of the system needed to control relevant devices to improve indoor air quality through the interaction with the measuring devices. Currently, the servers for the interaction of indoor air quality devices and IoT devices are divided into conventional server type and serverless type, comparing the differences in response time of IoT devices to changes of indoor air quality.

  • PDF

학교교실의 냉방시 실내열.공기 환경 실태 (Present Condition of Indoor Thermal and Air Environment by Air-conditioning in School Classrooms)

  • 최윤정;김혜경;황진아;이선아;정연홍
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.291-296
    • /
    • 2006
  • The purpose of this study were to make clear the present condition of indoor thermal and air environment by air-conditioning in school classrooms and to analyze the relation of the living conditions with indoor environment. The measurements on physical elements and observations on living conditions were carried out in 6 classrooms of 3 middle or high schools. Measuring elements were indoor temperature, relative humidity, $PM_{10}$ and $CO_2$ concentration. As results, the averages of indoor temperature each classrooms were 24.9${\sim}$26.6 . Most of classrooms were lower than the Maintenance standard(26${\sim}$28 ) of School Health Law. The means of relative humidity were 51.3${\sim}$72%, all classrooms were ranged within the standard(30${\sim}$80%). The means of $PM_{10}$ concentration were 3.5${\sim}$23.1 ${\mu}g/m^3$, all classrooms were kept within the standard(100 ${\mu}g/m^3$). The means of $CO_2$ concentration were 1218.7${\sim}$4705.4 ppm, all classrooms were exceed the standard(1,000ppm). The results of analysis on relations of living conditions with the physical elements are as follow; the air conditioner set of temperature, windows and doors opening elapsed time, the number of students in classrooms and activities of students had certain effect on indoor environment.

  • PDF