• Title/Summary/Keyword: indoor humidity

Search Result 490, Processing Time 0.063 seconds

An Investigation of Indoor Air Quality of Public Transportation System in Seoul City (서울시의 대중교통수단내 실내공기질에 대한 연구)

  • 김윤신;홍승철;전준민
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.1
    • /
    • pp.28-38
    • /
    • 1994
  • The objective of this study were to measure concentrations of indoor pollutants in public transportation systems to provide importance of indoor air quality in transportation systems to policy makers. Indoor air quality of the pollutants (CO, CO$_2$, PM-10) and environmental sources (temperature, humidity) were measured at subway, seat-type bus, and city-type bus in the Seoul area from April to September 1992. The same pollutants and environmental sources were also measured at selected bus stops and subway stations during October 1991-September 1992. The mean concentrations of indoor pollutants in the public transportation systems were showed 115.5 $\mu$g/m$^3$ in PM-10, 6.8 ppm in CO, and 2167.9 ppm in CO$_2$, respectively. The mean values of PM-10 and CO showed below the U.S. 24 hour standard value of PM-10 and the Korea ambient CO standard, while the mean concentrations of CO$_2$ exceeded the Korea CO$_2$ standard. The highest levels of indoor concentration at public transportation systems were PM-10 of 134.6 $\mu$g/m$^3$ in the subway, CO of 8.9 ppm in the city-type bus, CO$_2$ of 2,511.1ppm in seat-type bus, respectively. The results showed that indoor air quality in bus and subway seemed likely to be affected by number of passengers and outdoor air infiltrated from exhausted gases of automobiles.

  • PDF

Photocatalytic Oxidation of Indoor Air Volatile Organic Compounds (VOCs) in pub Level

  • Jo, Wan-Kuen;Kim, Dong-Hyun;Ki, Jae-Chang;Huh, Jeung-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.E4
    • /
    • pp.157-168
    • /
    • 2003
  • This study evaluated the technical feasibility of the application of titanium oxide (TiO$_2$) photocatalysis for the removal of VOCs in low ppb concentrations commonly associated with non -occupational indoor air quality issues. A series of experiments were conducted to evaluate four parameters (relative humidity (RH), hydraulic diameter (HD), photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) for the PCO destruction efficiencies of the selected target VOCs. None of the target VOCs presented significant dependency on the RH, which is inconsistent with a few previous studies. However, it is noted that the three parameters (HD, RM and IPS) should be considered for better VOCs removal efficiencies for the application of TiO$_2$ photocatalytic technology for cleansing non -occupational indoor air. The PCO destruction of VOCs at concentrations associated with non-occupational indoor air quality issues can be up to nearly 100%. The amount of CO generated during PCO would be negligible in comparison to the indoor CO levels. These results can make the PCO reactor an important tool in the effort to improve non-occupational indoor air quality.

Estimation of Source Emission Rate on Volatile Organic Compounds and Formaldehyde Using Indoor Air Quality Modeling in New Apartment (실내공기질 모델을 이용한 신축공동주택의 VOCs 및 HCHO 배출량 추정)

  • Sim, Sang-Hyo;Kim, Yoon-Shin;Yang, Won-Ho
    • Journal of Environmental Science International
    • /
    • v.15 no.10
    • /
    • pp.929-933
    • /
    • 2006
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time Indoors. Especially when indoor environments have sources of contaminants, exposure to in-door air can potentially pose a greater threat than exposure to ambient air. In this study, estimations of volatile organic compounds and formaldehyde omission rate in indoor environments of new apartments were carried out using mass balance model in indoor environment, because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. Considering the estimated emission rate of volatile organic compounds and formaldehyde, it Is suggested that new apartment should be designed and constructed in the aspect of using construction materials to emit low hazardous air pollutants.

The Indoor Thermal and Air Environment of General Apartment Houses during Winter in Cheongju City (청주시 아파트 일반가정의 겨울철 실내열·공기환경 현장측정조사)

  • Cho, Jun Haeng;Choi, Yoon Jung
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.111-120
    • /
    • 2013
  • The purposes of this study were to investigate the actual state of the indoor thermal and air environment in general apartment houses during winter in Cheongju City, to analyze the related factors with the indoor thermal and air environment, and to make suggestions for the improvement. A series of visiting field investigation was conducted in twenty units between 28th December, 2010, and 11th March, 2011. The field investigations included the measurement of physical indoor environmental conditions, the observation of architectural characteristics and resident's behavior, and the on-site questionnaire survey of residents. The measured values of each units were compared to evaluation standard and were categorized to group by the difference between units. Factors related to the difference of the measured values between the groups were analyzed. The findings are summarized as followed. The indoor temperature of apartment houses during winter in Cheongju City was generally suitable. The relative humidity was slightly dry, while the $CO_2$ concentration was found to be excessively high. The factors related indoor environment were analysed as heating operation, ventilation, gas range use, and hanging out the wash to dry in indoors.

Evaluation of Indoor Air Quality Improvement by Formaldehyde Emission Rate in School Indoor Environment Using Mass Balance (물질수지를 이용한 학교 실내환경의 포름알데히드(HCHO) 배출량 산정에 의한 실내공기질 개선 평가)

  • Yang, Won-Ho;Son, Bu-Soon;Kim, Dae-Won;Kim, Young-Hee;Byeon, Jae-Cheol;Jung, Soon-won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.160-165
    • /
    • 2005
  • Schools have significant and serious indoor environmental health problem, of which indoor air quality (IAQ) in school building may affect the health of the students and indirectly affect learning performance. Schools are of special concern when regarding indoor exposure to air pollutants, because students are particularly sensitive to pollutants and spend a significant amount of time in that environment. Therefore researches for improvement of indoor air quality have been developed such as installation of air cleaning device, ventilation system, titanium dioxide(TiO2) coating and so on. However, it is difficult to evaluate the magnitude of improvement of indoor air quality in field study because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. In this study, evaluation of reduction of formaldehyde emission rate in school indoor environments by far-Infrared ray coating material was carried out using mass balance model in indoor environment. we proposed the evaluation method of magnitude of improvement in indoor air quality, considering outdoor level and ventilation. Since simple indoor concentration measurements could not properly evaluate the indoor air quality, outdoor level and ventilation should be considered when evaluate the indoor air quality.

Wireless Sensors Module for Remote Room Environment Monitoring

  • Lee, Dae-Seok;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.449-452
    • /
    • 2005
  • For home networking system with a function of air quality monitoring, a wireless sensor module with several air quality monitoring sensors was developed for indoor environment monitoring system in home networking. The module has various enlargements for various kinds of sensors such as humidity sensor, temperature sensor, CO2 sensor, flying dust sensor, and etc. The developed wireless module is very convenient to be installed on the wall of a room or office, and the sensors in the module can be easily replaced due to well designed module structure and RF connection method. To reduce the system cost, only one RF transmission block was used for sensors' signal transmission to 8051 microcontroller board in time sharing method. In this home networking system, various indoor environmental parameters could be monitored in real time from RF wireless sensor module. Indoor vision was transferred to client PC or PDA from surveillance camera installed indoor or desired site. Web server using Oracle DB was used for saving the visions by web-camera and various data from wireless sensor module.

  • PDF

Study on the Air Quality of Metropolitan Subway Stations (수도권 지하철 지하역사의 실내공기질 연구)

  • Cho Young-Min;Park Duckshin;Park Byung-Hyun;Park Eun-Young
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.77-82
    • /
    • 2005
  • Recently, people's rising interests toward a 'well-being' lifestyle together with research contributions are accelerating the concerns regarding indoor air pollution making indoor air quality management an emerging environmental challenge of the era. The Ministry of Environment began to regulate the air quality of railway stations last year. The newly established 'Indoor Air Quality Act' covers 17 facilities whereas only underground subway stations and underground markets were regulated by previous 'Underground Air Quality Management Act' of 1996. In this study, we carried out the measurement of temperature, relative humidity, CO(carbon monooxide), $CO_2$(carbon dioxide), HCHO(formaldehyde), PM-10(particulate matters), and VOCs(volatile organic compounds) in underground subway stations. Based on the obtained results, we will suggest a way to improve the indoor air quality of the subway stations.

  • PDF

Effect of indoor environmental factors on the physical symptoms of dental hygienists (실내 환경 요인이 치과위생사의 신체증상에 미치는 영향)

  • Hong, Min-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.2
    • /
    • pp.197-204
    • /
    • 2014
  • Objectives : The purpose of the study is to examine the effect of the indoor environmental factors of dental hygienists on physical symptoms. Methods : The subjects were 210 dental hygienists in dental hospitals and clinics in Seoul, Gyeonggi Province, Incheon and South Chungnam Province from May 1 to June 20, 2013. Results : There were significant differences between the presence or absence of windows in respiratory symptoms and eye symptoms. Room temperature, bad smell, and dry humidity had significant influences on physical and respiratory symptoms. Dermatological and ophthalmological symptoms were affected by dryness, smell and dusts. Dusts and bad smell also had influences on a variety of subjective symptoms. Conclusions : The indoor environments of dental hospitals and clinics affect the respiratory, dermatological, and ophthalmological symptoms because various hazardous materials are generated by the dental treatment. Therefore dental hygienists should have a correct understanding of bacteria, dusts and bio-aerosol in order to ensure the successful environmental control.

The Study of Relationship on Bio-Aerosol with Indoor Temperature Difference (실내 온도차에 따른 부유세균과의 상관관계 연구)

  • Park, Jin-Young;Kim, Sam-Uel;Yun, Jung-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.737-741
    • /
    • 2008
  • The indoor environment has an effect on heath of human in indoor room that they live largely. We will know Bio-Aerosol that causes illness, such as a flu, an asthma and an atopy etc. and see a relationship between Bio-Aerosol and temperature as an experiment in Air-Conditioned room. In the future, this data can use a basic data for an effect of Bio-Aerosol on indoor environment.

  • PDF

A Study on the Control of Water Flow and Water Temperature in the Radiant Cooling System through Simulations (시뮬레이션을 통한 바닥복사냉방 시스템의 공급유량 및 냉수온도 제어에 관한 연구)

  • 김용이;윤혜림;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.532-540
    • /
    • 2001
  • The objectives of this study are to analyze the control variables according to condensation occurrence, to find the range in floor surface temperature and frequency of condensation, and to evaluate the control methods through simulations when the radiant heating system is used for cooling. Through the simulation analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The results show that the lowest floor surface temperature is around $23^{\circ}C$, the surface condensation can be prevented by controlling indoor humidity within 20g/kg(DA0, and that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF