This study evaluated indoor environmental characteristics in an office room equipped both with ventilation window system and central cooling system. Fresh air is supplied only by the central cooling system whereas indoor air is discharged outside through both ceiling diffuser and a ventilation window system. Numerical study is conducted by changing the volumetric flow rates of exhaust ports of each system. For estimating the performance of this coupled system, $CO_2$ concentration and Predicted Mean Vote (PMV) were calculated using Computational Fluid Dynamics (CFD) simulation. The more the ceiling diffuser exhausts indoor air, the more the $CO_2$ concentration decreases. However, when the ventilation window system exhausts more indoor air, thermal comfort level gets improved in the office room with cooling system. Therefore, when the ventilation window system is operated, the coupled operation with central cooling system should be considered for enhancing indoor air quality and thermal comfort, together.
Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Understanding the effectiveness of indoor air quality control depends on knowledge of the characteristics of air pollutants in indoor air, especially their quantities and persistence, and the relevance of indoor sources to these factors. Toluene within new and established houses has been determined and factors significant to its presence have been identified. A total of 30 selected houses in Seoul, Asan and Daegu areas that were constructed within 4 years and over 4 years of construction were measured the concentration of toluene from July to September in 2004. Toluene emission decay of double-exponential model exhibited good fit of $Y=276.37e^{-1.21x}(R^{2}=0.34,\;P=0.06)$ for 2 years and then $Y=51.54e^{-0.11x}(R^{2}=0.40,\;P=0.0)$ from 23 years in new houses. In case of living in new houses, noncarcinogenic health effects of exposure to toluene was 1.38 of hazard quotient (HQ) comparing to toluene reference dose of 0.13 mg/kg-day.
Six modules composed of individual sensors and circuit systems for oxygen, temperature, humidity, volatile organic compounds, dust, carbon dioxide, in the indoor air quality control were examined to see their individual performances. Experimental results showed that all the six modules were in good linearity with individual concentration variations
한국환경보건학회 2004년도 International Conference Current Challenges and Advances in Environmental Health
/
pp.45-50
/
2004
Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Alt hough technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor NO2 concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and NO2 source strength were estimated. Geometric means of ventilation rate were 1.44 ACH in Brisbane, assuming a residential NO2 deposition constant of 1.05 hr-1, and 1.36 ACH in Seoul, with the measured residential NO2 deposition constant of 0.94 hr-1. Source strengths of N02 were 15.8 ${\pm}$ 18.2 ${\mu}$g/m3${\cdot}$hr and 44.7 ${\pm}$ 38.1 ${\mu}$g/m3${\cdot}$hr in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.
The work of hairdressers includes washing, coloring, bleaching, permanent waving, conditioning, and cutting hair. Hairdressers are subjected to a number of physical and toxicological hazards. The toxicological hazards are those resulting from exposure to a wide range of chemicals that are usually classified active processes. In this study, twenty beauty shops were selected to assess the exposure to indoor air pollutants such as VOCs and particulate matter $(PM_{10})$ during one month from September 1 to September 30, 2003. Indoor air quality of beauty shops might be worse by vehicle emissions because the beauty shops were generally located near roadways. Personal exposures to VOCs and $PM_{10}$ were related to indoor concentrations of beauty shops. According to the questionnaire, hairdressers complained of sore throat, eye irritation, and nervousness as physical symptoms. The measured mean concentrations of respiratory particulates were $30.5ng/m^3$ in indoor, $30.5ng/m^3$ in outdoor and $44.0ng/m^3$ on personal levels. The personal concentration was found higher than indoor and outdoor concentrations. The heavy metals mean concentrations were shown as indoor (Na>Zn>Cr), outdoor (Cr>Zn>Pb), and personal (Na>Cr>Zn) levels. Conclusively, customers as well as workers in the beauty shops might be highly exposed to air pollutants from indoor and outdoor sources. Therefore, proper management should be taken to improve the indoor air quality in beauty shops.
Journal of Korean Society for Atmospheric Environment
/
제17권E3호
/
pp.109-115
/
2001
Acidic air pollutants were collected to characterize indoor air quality at a private house in Seoul during the spring period. All indoor and outdoor samples were measured simultaneously using an annular denuder system. The data set was collected on twelve different days with a 24-hr sampling period in April and May 1997. The chemical species measured were HN $O_3$, HN $O_2$, S $O_2$ and N $H_3$in the gas phase and P $M_{2.5}$ (dp 2.5 ${\mu}{\textrm}{m}$), S $O_4$$^{2-}$, N $O_3$$^{[-10]}$ and N $H_4$$^{+}$ in the particulate phase. Indoor concentrations of HN $O_2$, N $H_3$, and P $M_{2.5}$ were greater than outdoor levels. However, indoor concentrations of HN $O_3$, S $O_2$, N $O_3$$^{[-10]}$ and N $H_4$$^{+}$ were less than those found from outdoors. In the case of S $O_4$$^{2-}$, the indoor and outdoor concentrations were similar. Indoor concentrations of P $M_{2.5}$ , S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ were dependent upon the outdoor concentrations. A tracer-gas decay technique with sulfur hexafluoride (S $F_{6}$ ) as the tracer gas was used to estimate the air exchange rate of a private home in the spring. The average air exchange rate was computed to be 2.87 h $r^{-1}$ .X> .
Background: Adolescents are relatively more sensitive than adults to exposure to indoor pollutants. The indoor air quality in classrooms where students spend time together must therefore be managed at a safe level because it can affect the health of students. Objectives: In this study, three types of green-wall models were applied to classrooms where students spend a long time in a limited space, and the resulting effects on reducing PM were evaluated. Methods: In the middle school classrooms which were selected as the experimental subjects, IoT-based indoor air quality monitoring equipment was installed for real-time monitoring. Three types of plant models (passive, active, and active+light) were installed in each classroom to evaluate the effects on improving indoor air quality. Results: The concentration of PM in the classroom is influenced by outdoor air quality, but repeated increases and decreases in concentration were observed due to the influence of students' activities. There was a PM reduction effect by applying the green-wall model. There was a difference in PM reduction efficiency depending on the type of green-wall model, and the reduction efficiency of the active model was higher than the passive model. Conclusions: The active green-wall model can be used as an efficient method of improving indoor air quality. Additionally, more research is needed to increase the efficiency of improving indoor air quality by setting conditions that can stimulate the growth of each type of plant.
Background: With the rise in global mobility, aircraft indoor air quality has become a significant public health concern. This study focuses on the health implications of increased travel and bleed air-air drawn from aircraft engines for cabin pressurization and air conditioning. Objectives: This research aims to review the potential health effects related to exposure to aircraft cabin air, particularly the effects of bleed air during fume events. Methods: We conducted a literature review of existing studies on aircraft cabin air quality. We focused on both the immediate and health effects of exposure to cabin air, particularly those related to bleed air contaminants. Results: The review found a possible link between exposure to aircraft cabin air and certain health issues, especially in cabin crew and frequent flyers. There was an increased incidence of respiratory and neurological symptoms related to bleed air exposure. However, the cumulative health effects of frequent air travel remain inconclusive due to limited data. Conclusions: This study highlights the need for improving air quality in aircraft to protect public health. While further research is needed to understand the cumulative effects of frequent air travel, the reduction of exposure to bleed air contaminants should be a priority. These findings underline the need for regulatory changes and technological improvements in aircraft cabin air quality.
Recently, people's rising interests toward a 'well-being' lifestyle together with research contributions are accelerating the concerns regarding indoor air pollution making indoor air quality management an emerging environmental challenge of the era. The Ministry of Environment began to regulate the air quality of railway stations last year. The newly established 'Indoor Air Quality Act' covers 17 facilities whereas only underground subway stations and underground markets were regulated by previous 'Underground Air Quality Management Act' of 1996. In this study, we carried out the measurement of temperature, relative humidity, CO(carbon monooxide), $CO_2$(carbon dioxide), HCHO(formaldehyde), PM-10(particulate matters), and VOCs(volatile organic compounds) in underground subway stations. Based on the obtained results, we will suggest a way to improve the indoor air quality of the subway stations.
Objectives: The Korean government implemented a smoke-free regulation for pubs with a net indoor area of ${\geq}100m^2$ on January 1, 2014. The purpose of this study was to determine the indoor levels of concentrations of particulate matter smaller than $2.5{\mu}m$ ($PM_{2.5}$) in implemented and non-implemented pubs in Seoul and Changwon. Methods: $PM_{2.5}$ concentrations in fifty-two $100-150m^2$ (implemented) and fifty-seven < $100m^2$ (non-implemented) pubs were measured. A real-time aerosol monitor was used to measure $PM_{2.5}$ concentrations. Field technicians recorded characteristics of the pubs including net indoor area, indoor volume and presence of smoking rooms and counted the number of burning cigarettes, patrons and vents. Results: Differences between indoor and outdoor $PM_{2.5}$ concentrations in $100-150m^2$ and < $100m^2$ pubs were not significantly different in each city. Smoking was observed in 33% of $100-150m^2$ pubs and 51% of < $100m^2$ pubs. Average differences between indoor and outdoor $PM_{2.5}$ concentrations in the $100-150m^2$ and < $100m^2$ pubs were $79.2{\mu}g/m^3$ and $155.6{\mu}g/m^3$, respectively. When smokers were not observed, differences between indoor and outdoor $PM_{2.5}$ concentrations ware $12.4{\mu}g/m^3$ in $100-150m^2$ pubs and $24.5{\mu}g/m^3$ in < $100m^2$ pubs. Conclusion: Although the regulation was implemented only in ${\geq}100m^2$ pubs, a higher difference between indoor and outdoor $PM_{2.5}$ concentrations was observed in implemented and non-implemented pubs with smokers. Strict implementation of the regulation in all pubs is needed for better indoor air quality.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.