• Title/Summary/Keyword: indoor environmental quality

Search Result 530, Processing Time 0.026 seconds

Assessment of PM2.5 and Black Carbon Concentrations among Street Vendors: Focusing on Cooking Stalls (거리 가판대에서의 초미세먼지(PM2.5)와 블랙 카본(BC)의 농도평가: 조리 가판대를 중심으로)

  • Minjung, Kim;Jiyun, Shin;Jiwon, Jeong;Sueun, Choi;Kiyoung, Lee
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.6
    • /
    • pp.291-297
    • /
    • 2022
  • Background: PM2.5 and black carbon (BC) can be generated from cooking and from vehicle operation. Street vendors may be exposed to PM2.5 and BC due to their proximity both to roads and to cooking activities. Objectives: The objectives of this study were to evaluate the PM2.5 and BC concentrations in cooking stalls and to determine the effects of cooking activity and of types of cooking. Methods: Indoor and outdoor PM2.5 and BC concentrations, temperature, and relative humidity were measured in 32 stalls in April and May 2022. Behavioral factors such as the presence of cooking activity and types of cooking were observed. Student's T-test was performed using the difference of indoor and outdoor PM2.5 and BC concentrations to compare the effects of cooking activity and to compare types of cooking. Results: One-hour averages of the difference in indoor and outdoor PM2.5 concentrations for cooking stalls and non-cooking stalls were 9.7±15.7 ㎍/m3 (n=22) and -0.5±0.4 ㎍/m3 (n=10), respectively. The difference in indoor and outdoor PM2.5 concentrations in cooking stalls was significantly higher than in non-cooking stalls (p<0.05). The indoor PM2.5 concentration for stalls for Chinese pancakes and teokbokki exceeded the standards for indoor air quality in South Korea (50 ㎍/m3 ). The indoor PM2.5 concentration for Korean pancake stalls exceeded the standards for outdoor air quality in South Korea (35 ㎍/m3 for 24 hours). Conclusions: The PM2.5 concentrations in stalls with cooking activity was significantly higher than those in stalls without cooking activity. Some stalls with certain types of foods exceeded standards for indoor and outdoor air quality in South Korea. Better management of indoor air quality in stalls with cooking activities is necessary.

Occupant Characteristics Analysis based on Integrative IEQ Weighting Factor in Residential Buildings - Based on Occupant Survey of Residential Building in Chungbuk Province (주거건물에서의 통합 실내환경평가 가중치 분석을 통한 거주자 특성분석 - 충북지역 주거건물 거주자 설문조사를 바탕으로)

  • Yoon, Sung-Hoon;Yun, Hee-Jin
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.87-92
    • /
    • 2016
  • Purpose: The objective of this research is to investigate and analyze the relationship between physical residential conditions and occupants' responses in apartment buildings by POE(Post-Occupancy Evaluation). The analysis results from this research will help to identify the indoor residential problems and find design solutions for improving overall residential indoor residential environment. Method: The occupant survey was conducted at four different apartment complex area at Cheongju City, Chungbuk Province, Korea. Combination of unbalanced indoor environmental conditions in residential building had difference of occupants' responses according to occupants' characteristics, such as gender, age, and so on. The survey collected data regarding the occupants' EQ(Environmental Quality) priorities to determine the weight of each environmental-quality factor (lighting, acoustic, thermal and indoor air quality). A paired comparison method was used to determine the weight by comparing the relative importance of the two factors based on occupant's survey response. Result: The output from this research is useful to understand the residential environment, occupants' satisfaction, preference, and identifies the current residential problems and finds an architectural solution in apartment buildings.

A Study on the Safety Consciousness of Resident for the Environmental Factors in Apartments (공동주택 환경요인에 대한 거주자의 안전의식 조사 연구)

  • Park, Hyeon-Ku;Song, Hyuk;Go, Seong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.106-113
    • /
    • 2005
  • The housing is a human's basic space and the comfort and the safety are the most basic conditions. According to the flow of age for Well-Being since the 21th, the suppliers and the users of apartment are making best effort now for the embossment of green environmental quality of apartment, and outstretch their hands for marketing strategic purposes in a side of indoor and outdoor environment with distinctive elements. But these supply and use are on progress competitively with the simple distinction, it is thought that indoor and outdoor environment are must be promoted according to the survey of residents' consciousness. So this study aims to provide basic materials with residents for the promotion of comfortable dwelling environment by solving the basic safety problem and also aims to survey and analyze the residents' safety consciousness in object of physical and non-physical environmental quality of indoor and outdoor of apartment by analyzing indoor air quality pollution, the feeling of being victimize caused by air pollution and safety consciousness according to physical environment elements.

Classification of Pollution Patterns in High School Classrooms using Disjoint Principal Component Analysis (분산주성분 분석을 이용한 고등학교교실 내 오염패턴분류에 관한 연구)

  • Jang, Choul-Soon;Lee, Tae-Jung;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.808-820
    • /
    • 2006
  • In regard to indoor air quality patterns, the government introduced various polices that were about managing and monitoring quality of indoor air as a major assignment, and also executed 'Indoor Air Quality Management Act' which was presented in the May, 2004. However, among the multi-usage facilities controlled by the Act, the school was not included yet. This study goal was to investigate PM 10 pollution patterns of the high school classrooms using a pattern recognition method based on cluster analysis and disjoint principal component analysis, and further to survey levels of inorganic elements in May, June, and September, 2004. A hierarchical clustering method was examined to obtain possible objects in pseudo homogeneous sample classes by transformation raw data and by applying various distance. Following the analysis, the disjoint principal component analysis was used to define homogeneous sample class after deleting outliers. Then three homogeneous Patterns were obtained as follows: the first class had been separated and objects in the class were considered to be sampled under semi-open condition. This class had high concentration of Ca, Fe, Mg, K, Al, and Na which are related with a soil and a chalk compounds. The second class was obtained in which objects were sampled while working air-conditioners and was identified low concentration of PM 10 and elements. Objects in the last class were assigned during rainy day. A chalk, soil element and various types of anthropogenic sources including combustions and industrial influenced the third class. This methodology was thought to be helpful enough to classify indoor air quality patterns and indoor environmental categories when controlling an indoor air quality.

Assessment of Conscious Coginition Degree and Survey on Oxyen Generators using the Indoor Environment (실내환경중의 산소발생기 사용에 대한 인식도 평가)

  • 손종렬;조윤수;이규현;황상용
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.4
    • /
    • pp.64-69
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and office has been concern of people, scientists and related the public. The oxygen in air was very important and essential element in every aspect of life. This study was performed on a questionnaire survey of 400 people about their awareness of indoor air quality, oxygen generators and measured of oxygen concentration in indoor environment. The results obtained were as follows; As respondents are having their 90% of daytime indoors a day, and 80% of them can feel indoor air pollutions degrees directly by particle matters. The control of most important problems of IAQ was the poor ventilation. We know that 22% of the respondents was recognized the oxgen generator. And for the installation of indoor pollution control equipment, 20% of all respondents installed oxygen generators because almost respondents was not satified the trust of ability purified indoor air pollutants. In the experimental results, it was found that the oxygen concentration of sampling sites were in the range of 20~23.5%. Therefore, it was recommended that the government related IAQ was suggested the guideline and control of oxygen generators. Finally, it appeared that the oxygen generators using indoor environment can be applied to new technology for cleaning of indoor air.

Assesment of Indoor Air Quality within Public Transport Vehicles operating in specified locations throughout Seoul (서울 일부 지역 교통수단의 실내 공기질 평가)

  • Sohn Jong-Ryeul;Choi Dal-Woong;Choi Jung-Sook;Woo Wan-Gi
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.12-20
    • /
    • 2006
  • This paper was conducted concerning the degree of indoor air quality in public transport vehicles such as taxicabs, buses and subway trains, as sampled through the active participation of drivers and passengers in Seoul between 13th August 2005 and 2nd November 2005. The results were summarized as follows: 1. Among the measured substances especially respirable particulate matters ($PM_{10}$), total bacteria counts (TBC) and carbon dioxide ($CO_2$) exceeded the standard level of $150{\mu}g/m^3,\;800CFU/m^3$ and 1000ppm. 2. The concentration of carbon dioxide ($CO_2$) in taxi recorded 2491ppm, which is more than the standard amount of 1000ppm. This level was comparatively higher than all other public transportation methods. Total bacteria counts (TBC) in bus and subway recorded $1082CFU/m^3\;and\;1856CFU/m^3$, respectively. 3. The drivers who regularly work long hours showed the higher concern about contamination of the air inside the public transport vehicles and they considered it to be worse than the air outside. In contrast, the general public showed less concern about the air quality inside the public transport vehicles. However, they too acknowledged that the quality of the air inside the public transport vehicles was poor. In regards to the degree of indoor air quality in the public transport vehicles, a counterplan must be implemented urgently to effectively combat the excessive levels of $PM_{10}$, microorganism and $CO_2$. We need to gather more conclusive evidence pertaining to other possible contaminants and influencing factors.

The physicochemical Characterization of ETS (Environmental Tobacco Smoke) (Environmental Tobacco Smoke의 이화학적 특성)

  • 이문수
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.17 no.1
    • /
    • pp.79-97
    • /
    • 1995
  • On the basis of the literature, which is at present still scientific information improvable, the results of research done so far into the occurrence and analytical methodology of major markers of environmental tobacco smoke(ETS) have been summarized. Key areas addressed are: differences in physicochemical composition between mainstream smoke, sidestream smoke and ETS: techniques for field measurement of ETS: relationship between indoor air quality with ETS and its distribution view of US EPA and its problems: biological effects and concerning estimation of ETS exposure.

  • PDF

The Characteristics of Indoor Air Quality Variation in Underground Parking Lots of Apartments located in Northern Gyeonggi Province (경기도 북부지역 아파트의 지하주차장 실내공기질 변동 특성)

  • Park, Hyun-Ku;Jung, Yeon-Hoon;Kim, Byeong-Lok;Kim, Jin-gil;Shin, Hyung-Soon;Lee, Sang-Soo;Oh, Jo-Kyo
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.250-258
    • /
    • 2018
  • Objectives: The study examined indoor air quality during daytime and commute times in underground parking lots in five apartments located in northern Gyeonggi province. Methods: This study examined the temporal characteristics of $PM_{10}$, $CO_2$, CO, HCHO and VOCs in the indoor air quality of the underground parking lots in five apartments. Results: $PM_{10}$ concentration in daytime were ranged from 37.4 to $69.9{\mu}g/m^3$ which complied with the indoor air quality maintenance standard ($200{\mu}g/m^3$) and Gyeonggi province ordinance standard ($180{\mu}g/m^3$). However $PM_{10}$ concentrations in commuting time were in range of $447.3{\sim}944.0{\mu}g/m^3$ that exceeded for both criteria. The $CO_2$, CO and HCHO concentrations complied with the standard. The VOCs indicated high tendency in the order of toluene, xylene, ethylbenzene and benzene. This tendency was more apparent in commuting time than daytime. Conclusion: All indoor parking lots of five apartments were equipped with ventilators. However the most apartment residents did not operate blowers to save electricity and the lack of interest for indoor air quality. In order to improve the indoor air quality of underground parking lots in apartment, operating ventilation system during commuting time is recommended.

Evaluation of Ventilation System Performance Using Indoor Air Quality Model (실내공기질 모델을 이용한 환기 시스템의 공기 정화 효율성 평가)

  • 최성우
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.57-66
    • /
    • 1997
  • Successful energy conservation and good indcfor air quality (IAQ) are highly dependent on ventilation system. Air filtration is a primary solution of indoor air control strategies in terms of reducing energy consumption and improving ihdoor air quality. A conventional system with bypass filter, as it is called variable-air-volume/bypass filtration system (VAV/BPFS), is a variation of the conventional variable air volume (VAV) systems, which is designed to eliminate indoor air pollutant and to save energy. Bypass filtration system equipped with a high-efficiency particulate filter and carbon absorbent provides additional cleaned air into indoor environments and maintain good IAQ for human health. The objectives of this research were to compare the relative total decay rate of indoor air pollutant concentrations, and to develop a mathematical model simulating the performance of VAV/BPFS. All experiments were performed in chamber under the controlled conditions. The specific conclusions of this research are: 1. The VAV/BPFS system is more efficient than the VAV system in removing indoor air pollutant concentration. The total decay rates of aerosol, and total volatile organic compound (TVOC) for the VAV/BPFS system were higher than those of the conventional VAV system. 2. IAQ model predictions of each pollutant agree closely with the measured values. 3. According to IAQ model evaluation, reduction of outdoor supply air results in decreased dilution removal rate and on increased bypass filtration removal rate with the VAV/BPFS. As a results, we recommends the VAV/BPFS as an alternative to conventional VAV systems.

  • PDF

Characteristics of Heavy Metal Concentrations and Indoor Atmospheric Environments in Busan Metropolitan Area, Korea

  • Park, Jong-Kil;Kim, Yoo-Kuen;Lee, Hwa-Woon;Jang, Nan-Sim;Park, Moon-Ki
    • Journal of Environmental Science International
    • /
    • v.11 no.8
    • /
    • pp.801-810
    • /
    • 2002
  • The current paper describes the indoor/outdoor air quality in school environments through analyses of the heavy metal concentrations using Inductive Coupled Plasma(ICP). School environments in a heavy traffic area, two industrial areas, quasi-industrial area, and residential area were evaluated. The results were as follows: (1) The locations with the highest indoor and outdoor concentrations of heavy metals were the industrial areas followed by the heavy traffic area, residential area, and quasi-industrial area in a descending order of magnitude. Plus, the indoor heavy metal concentrations were higher then the outdoor ones. (2) The main heavy metal components were Zn, Al and Ca. Higher concentration levels were found indoors than outdoors. The heavy metal concentrations were also higher in the classrooms than in the corridor or outdoors. (3) The total heavy metal concentrations in the studied areas were highly dependent on the weather elements. including the relative humidity, mixing ratio, and wet-bulb depression. Accordingly, special ventilation systems are recommended to reduce air pollution in school environments.