• 제목/요약/키워드: indoor environmental factors

검색결과 292건 처리시간 0.026초

실내 수공간 도입에 따른 온열 환경 변화 분석 (Analysis of Thermo Environment Change by Introduction of Indoor Water Space)

  • 오상목;오세규
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.53-60
    • /
    • 2012
  • This research is an illustrative research to verify the thermo environmental change created after introduction of indoor pond through abridged model test and simulation analysis. Especially, temperature and comfort level are analyzed by adjusting factors like size of water space, distance length, and location. Summary of the research is as follows. First, the most effective size of water space is 7% of the indoor size, from southern side. Temperature reduction effect is about $1.6^{\circ}C$(5.5%), and for the comfort level, it is found that pmv index increases 8%. Second, based on the simulation of distance length with the sphere, it is more effective as it is close to the surface. If distance length is more than 0.5m, there is no effect on reduction of temperature and comfort level of indoor environment. Lastly, for the analysis by location of the introduced water space, simulation is undertaken by dividing the water space (14% of the indoor size) with front, side, rear and center types. Temperature reduction effect is found to be : front type ($-1.53^{\circ}C$), side type ($-0.82^{\circ}C$), rear type ($-0.44^{\circ}C$), center type ($-0.28^{\circ}C$), respectively. The indoor environment change data by introduction of water space, found in this research, is at initial phase, but it is deemed to be a basic data to refer when planning actual water space.

생활 습관, 주거지 주변 녹지 비율 및 지하수 내 라돈 농도 따른 실내 라돈 농도 영향 모델 (Affected Model of Indoor Radon Concentrations Based on Lifestyle, Greenery Ratio, and Radon Levels in Groundwater)

  • Lee, Hyun Young;Park, Ji Hyun;Lee, Cheol-Min;Kang, Dae Ryong
    • Journal of health informatics and statistics
    • /
    • 제42권4호
    • /
    • pp.309-316
    • /
    • 2017
  • 라돈 및 그 자손은 폐암을 일으키는 환경적 위험인자로, 일상 활동 및 수면 등으로 많은 시간을 보내는 실내 라돈 농도 관리는 필수적이다. 이를 위해서는, 주거지를 둘러싼 개인적, 사회적, 환경적 요소에 대한 총체적 접근이 필요하다. 따라서 본 연구는 실내 라돈 농도에 영향을 미치는 다양한 인자를 찾아내고, 이를 활용한 포괄적 모델을 구축하고자 한다. 건축 자재 및 생활 양식을 포함한 주거 환경에 대한 자료를 얻기 위해 설문을 실시하였고, 의사결정트리 및 구조 방정식 모델링을 활용하였다. 그 결과 주거지 주변 녹지 비율, 불 투과성 층 비율, 주택과 지면의 맞닿은 상태, 매일 환기 습관, 난방 습관, 측정 장치 주위의 균열 및 침실여부는 실내 라돈 농도와 유의한 연관성을 보였다. 매일 환기 습관을 가질 경우 실내 라돈 농도가 $200Bq/m^3$ 이상인 비율이 11.6%로 줄었다. 한편 매일 환기습관이 없는 주거자의 주거지 주변 녹지 비율이 65% 이상이면 매일 환기 습관이 있는 주거자와 비교하여 15.3%의 비율이 증가하였다. 구축된 포괄적 모델의 실내 라돈 농도에 직접 영향을 미치는 인자는 주거지 주변 녹지 비율과 환기율이었다. 제시된 모델로 국내 라돈 농도에 대한 개인의 지리적 특성, 지하수 및 생활 양식 요소의 결합된 영향을 확인할 수 있었다.

사물인터넷 기반 실내 환경 관제시스템 설계 및 구현 (Indoor Environment Monitoring and Controlling System design and implementation based on Internet of Things)

  • 박재운;김대식;주낙근
    • 한국정보통신학회논문지
    • /
    • 제20권2호
    • /
    • pp.367-374
    • /
    • 2016
  • 오늘날 많은 사람들은 공동의 실내 공간에서 학업이나 업무 등의 다양한 일을 수행한다. 그러나 이렇게 함께 공동으로 사용하는 공간은 여러 가지 오염 요인에 의해 업무의 효율 뿐 만아니라 건강에도 좋지 않은 영향을 미치게 될 수 있다. 그래서 무엇보다도 공동으로 사용하는 공간에 대한 쾌적한 환경의 유지가 중요한 요소로 인식되고 있다. 본 논문에서는 이러한 공동으로 사용되는 사무실이나 도서관, 강의실 등의 공간을 보다 쾌적한 환경으로 만들기 위해서 환경적으로 유해한 요소들을 분석하고, 이러한 유해 요소들을 관리하여 보다 좋은 생활환경을 제공하기 위한 통합 실내 환경 관제시스템을 설계 구현한다. 제안된 실내 환경 관제시스템은 실내 환경의 상태를 실시간으로 모니터링 할 수 있고 액추에이터를 구동시킴으로써 쾌적한 환경을 제공할 것이다. 또한, 각종 실내 공간에 적용할 수 있을 뿐만아니라 사람들의 실내 환경오염 인지도 역시 높이는 방안이 될 것이다.

열화상 카메라를 이용한 공기 중 부유 진균 농도 추정방법 개발에 관한 연구 (Method Development for Estimating Concentration of Airborne Fungi Using a Thermal Imaging Camera)

  • 김기연
    • 한국산업보건학회지
    • /
    • 제25권4호
    • /
    • pp.465-471
    • /
    • 2015
  • Objectives: An objective of this study is to apply a thermal image camera which shows various color according to temperature of indoor surface for estimating concentration of airborne fungi. Materials and Methods: While wall temperature were monitored by applying the thermal image camera, airborne bacteria as well as air temperature and relative humidity have been measured in lecture room and toilet of university for seven months. Results: Based on the results obtained from this study, the ranges of temperature and airborne fungi concentration were $20{\sim}24^{\circ}C$ and $20{\sim}400cfu/m^3 $ for red image, $17.5{\sim}20^{\circ}C$ and $35{\sim}150cfu/m^3$ for orange image, $15.5{\sim}17.5^{\circ}C$ and $25{\sim}650cfu/m^3$ for sky-blue image, and $13.5{\sim}15.5^{\circ}C$ and $50{\sim}200cfu/m^3$ for blue image, respectively. The color of indoor surface taken shot by thermal image camera showed consistent trend with temperature of indoor surface. There is, however, little correlation between color of indoor surface and airborne fungi concentration(p>0.05). Among environmental factors, relative humidity in indoor air showed a significant relationship with airborne fungi concentration(p<0.05). Conclusions: The more measurement data for proving statistically an association between color of indoor surface and airborne fungi concentration should be provided to easily estimate indoor level of airborne fungi.

老人福祉施設의 冬.夏節期 室內 溫熱環境 測定 및 溫熱感 評價 (An Study on the Evaluation of Thermal Indoor Environment and Thermal Sensations during Winter and Summer in Elderly Welfare Facilities)

  • 곽호;류우동;황광일;홍원화
    • 한국주거학회논문집
    • /
    • 제14권1호
    • /
    • pp.19-27
    • /
    • 2003
  • This study aims to survey the living spaces of the welfare facilities for the aged to get the objective relationships between the physical thermal environment and the users' subjective responses. The surveys were made twice in winter and once in summer during 2001 and 2002. An ambient temperature, relative humidity, air velocity, globe temperature were measured as physical elements of thermal environment and the ASHRAE Psychophysical Voting Scale were used as an evaluation index for subjective responses. As the results, the aged respond thermally comfortable, in spite of the differences among important factors such as thermal sensations, humidity sensations and air velocity sensations. Also the physical thermal environmental elements and the subjective responses indices exceed thermal comfort range calculated by PMV(Predicted Mean Vote) and PPD(Predicted Percentage Dissatisfied). It shows that the insulation of walls of the facilities is not enough for heating and cooling seasons, and the indoor environmental control is necessary.

직장인의 시간활동 양상 평가 (Assessment of Time Activity Pattern for Workers)

  • 이현수;솨이 지엔페이;우병렬;황문영;박충희;유승도;양원호
    • 한국산업보건학회지
    • /
    • 제20권2호
    • /
    • pp.102-110
    • /
    • 2010
  • Personal exposure relies on characteristics of time activity patterns of the population of concern as human activities impact the timing, location, and level of personal exposure. The information about time spent in microenvironments plays a critical role for personal exposure to air pollutants. It is useful to determine the precise times of the day that the subjects are in certain locations or engaging in specific activities because exposure to some air pollutants can depend on temporal trends. This study investigated time activity pattern for workers of Korean population over 19 years old with 8,778 workers in weekday. The residential indoor times were 12 hours. Time activity was different by gender and the mean times stayed at home in weekday were 12.9 hours in female and 11.42 hours in male, respectively. The major factors on residential indoor time and workplace time were age, monthly income, occupation and industry type, work position, education, and gender. Considering shorter than those in other countries, Korean workers spent less time at home after the working hours. Determinants of time activity pattern need to be taken into account in exposure assessment, epidemiological analyses, exposure simulations, as well as in the development of preventive strategies. Since there are substantial difference of Korean worker activity pattern, this information can be critical for exposure assessment in Korea.

Exposure Level of Airborne Bacteria in the University Laboratories in Seoul, Korea

  • Hwang, Sung-Ho;Yoo, Kyong-Nam;Park, Ji-Ho;Park, Dong-Uk;Yoon, Chung-Sik
    • 한국환경보건학회지
    • /
    • 제35권5호
    • /
    • pp.355-361
    • /
    • 2009
  • This study evaluated the bacterial concentrations and affecting factors at the laboratories of a university in Seoul, Korea. Thirty-three samples of total airborne bacteria (TAB) and eighteen samples of gram negative bacteria (GNB) were collected from both microbiology laboratories (7) and chemistry laboratories (6). GM (GSD) of TAB and GNB concentrations were 194 (2.52) $cfu/m^3$, 24 (4.1) $cfu/m^3$, respectively. TAB concentrations in the chemical laboratories (GM (GSD): 193 (2.0) $cfu/m^3$) were not significantly different from those in microbial laboratories (GM (GSD): 202 (2.7) $cfu/m^3$, (p>0.05)). GM (GSD) of TAB concentrationsat the top of sink, the center of laboratory, and the front of ventilation ventilation device within laboratories, 182 (3.2) $cfu/m^3$, 217 (2.2) $cfu/m^3$, 176 (2.4) $cfu/m^3$, respectively, were not significantly different (p=0.48). Related factors were measured such as temperature, relative humidity, floor of laboratory, number of persons and laboratory area. TAB concentrations were significantly related to temperature (r=0.36, p<0.05), and the floor of laboratory and temperature were also significantly related (r=0.49, p<0.001). However, other factors such as relative humidity, number of persons and laboratory area did not show any significant relationship with TAB concentrations (p>0.05). TAB concentrations were affected significantly by cleaning frequency (p<0.001) and floor of laboratory (p<0.05). There was also a significant difference (p<0.01) between TAB indoor concentrations and TAB outdoor concentrations. However, other factors such as general ventilation did not affect TAB concentrations (p>0.05) in this study.

A Location Tracking System using BLE Beacon Exploiting a Double-Gaussian Filter

  • Lee, Jae Gu;Kim, Jin;Lee, Seon Woo;Ko, Young Woong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권2호
    • /
    • pp.1162-1179
    • /
    • 2017
  • In this paper, we propose indoor location tracking method using RSSI(Received Signal Strength Indicator) value received from BLE(Bluetooth Low Energy) beacon. Due to the influence of various external environmental factors, it is very difficult to improve the accuracy in indoor location tracking. In order to solve this problem, we propose a novel method of reducing the noise generated in the external environment by using a double Gaussian filter. In addition, the value of the RSSI signal generated in the BLE beacon is different for each device. In this study, we propose a method to allocate additional weights in order to compensate the intensity of signal generated in each device. This makes it possible to improve the accuracy of indoor location tracking using beacons. The experiment results show that the proposed method effectively decrease the RSSI deviation and increase location accuracy. In order to verify the usefulness of this study, we compared the Kalman filter algorithm which is widely used in signal processing. We further performed additional experiments for application area for indoor location service and find that the proposed scheme is useful for BLE-based indoor location service.

화학 및 천연페인트에서 발생되는 TVOCs의 방출강도 특성 연구 (Characteristics of TVOCs Emission Factors from Chemical and Natural Coating Materials)

  • 김신도;김정호;박진수;이정주
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.487-492
    • /
    • 2004
  • Building materials are composed of very complex chemical compounds, and these indoor building materials discharge very much Volatile Organic Compounds(VOCs). We performed the environmental chamber test to investigate the Total VOCs(TVOCs) emission characteristics and emission factors about chemical and natural coating materials. As the result, we concluded that TVOCs emission are high at initial time and decreased in course of time. Natural paint was low emission level for TVOCs than chemical paint by small chamber test. The TVOCs emission factor-time profile showed a good fit with the results from the measured and predicted value.

A Study on the Perception Level and Proper Management of Indoor Air Quality Recognition in Elderly Care Hospital Workers

  • Choi, Mi-Suk
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권11호
    • /
    • pp.171-178
    • /
    • 2019
  • 본 연구에서는 노인요양병원의 실내공기질 관리계획을 제안하고자 노인요양병원의 실내공기질 수준을 측정하고 근무자의 실내공기질에 대한 인식에 대하여 조사하였다. 측정 항목은 온도, 습도, CO2, CO, PM10, VOC이며 2019년 4월 26일에 실시하였다. 설문 조사에 따르면 실내 공기질에 대한 만족도가 낮을수록 실외 공기질이 더 좋다고 응답하였으며 실내환경 요소 중 악취가 가장 낮은 것으로 응답하였으며 실내 공기질의 만족도가 높을 경우 실내환경 요소의 만족도도 높은 것으로 분석되었다. 다중응답 분석결과 "환기 부족"이었고 회귀 분석 결과 "공기질 관련성" 항목이 가장 낮은 것으로 분석되었다. 노인 요양 병원의 실내 공기질 환경을 최고 수준으로 유지하려면 냄새를 제거하기 위한 환기 장지를 추가로 설치하고 자연 환기 횟수를 늘리고 정기적인 환기담당자를 지정해야 할 것으로 판단된다. 이러한 계획을 수립함으로써 노인요양병원 근무자에게 최상의 서비스를 제공하기 위한 실내 공기질 환경을 제공 할 수 있다.