• 제목/요약/키워드: indoor environmental efficiency

검색결과 163건 처리시간 0.021초

인식 및 이용실태에 기반한 학교 실내 녹색공간의 효용성 분석 -수도권 중·고등학교를 중심으로- (Analysis of the Recognition and Usage of Indoor Green Space in Middle and High Schools )

  • 박준호;이주영
    • 한국환경과학회지
    • /
    • 제32권8호
    • /
    • pp.573-583
    • /
    • 2023
  • This study was conducted to verify the effectiveness of improving indoor environmental awareness, relieving stress, and improving learning efficiency in school indoor green space, and suggest desirable ways to develop indoor green space in the future. As part of the study, a survey was conducted among 225 individuals across six schools in a metropolitan area with garden and panel-type indoor gardens inside the school building. The survey comprised the current status and use of indoor green spaces, the perception of indoor green spaces, improvement measures in indoor green spaces, and basic properties. Semantic Differential (SD) was used to investigate the impression of school indoor spaces. Resultantly, the more frequent the use of green spaces in the school, the more they feel the positive effects of indoor green spaces, such as improving the school's indoor environment, reducing stress, and improving learning efficiency. In addition, it appears that the more frequent contact with the natural environment, the more they feel the positive effects provided by indoor green space at school. Therefore, it is suggested that educational conditions must be improved by revitalizing various green welfare, including indoor green areas, at the school level.

환기구 위치별 실내오염물질의 환기효과 변동에 관한 연구 (A Study on the Variation of Ventilation Effect for Indoor Air Pollutants by Ventilation Hole Sites)

  • 이정주;이주상;김신도
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.226-240
    • /
    • 1995
  • This research has a purpose to achieve experimental data used for design of ventilation systems necessary for indoor air quality control and their operation and management. For the study, spatial concentration distribution of indoor air quality according to pollutant site in a simplified model chamber. In low flow ventilation, flow pattern of indoor air was mainly influenced by diffusion and additionally, spatial distribution was formed by convection. Distribution of ventilation efficiency according to each pattern of model chamber was evaluated. It was confirmed that diffusion patterns of a pollutant among sites were formed, centering around main stream areas of supply and exhaust outlets.

  • PDF

아파트 실내정원의 겨울철 실내온열환경 조절효과 (Indoor Environmental Efficiency Indoor Garden in Apartment House during Winter)

  • 김정민;최윤정
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.212-216
    • /
    • 2005
  • The purpose of this study is to make clear the indoor thermal environmental efficiency of indoor garden in apartment during winter. The questionnaire survey was carried out during the l0th${\sim}$20th of February 2004, respondents consisted of 215 residents living in a subject apartment estate. The field measurements of indoor thermal elements were carried out at A house with indoor garden and at B house without indoor garden. The measurements in two-subject houses were taken on simultaneously the 11th of February. As Results, the residents living in apartments with indoor garden show positive response on air moisture and satisfaction. The daily ranges of indoor temperature and globe temperature in the A house were narrower than the B house. The average relative humidity in the A house was higher and constant than the B house. Therefore, it was seemed that indoor environment during winter in the house with indoor garden maintained more constant or comfortable than the house without indoor garden by earning effect and humidity control effect of plants.

  • PDF

공기청정기의 일부 실내공기 오염물질 제거효율에 관한 연구 (Efficiency of Removal for Indoor air pollutants by Air Cleaners in the Indoor Environments)

  • 이태형;김윤신;홍승철;이철민;김종철;전형진;김중호
    • 한국환경과학회지
    • /
    • 제14권5호
    • /
    • pp.491-497
    • /
    • 2005
  • In this study, we investigated $PM_{10},\;NO_2$, and l-hydroxypyrene(1-OHP) in urine at indoor environments which are 35 houses and 20 hospitals for using air cleaner and non-using air cleaner in Seoul metropolitan area and Kyoung-gi province from April, 2003 to February, 2004. Moreover, we examined effect of improvement for indoor air quality and health effect by concentration of 1-OHP also we investigated removal efficiency by air cleaner for $PM_{10},\;NO_2$, and 1-OHP that were 28.5\%,\;27.4\%,\;and\;42.1\%$ respectively. Concentration of$PM_{10},\;NO_2$, and 1-OHP were $19.02\pm18.14{\mu}g/m^3,\;8.66\pm3.06ppb,\;and\;0.19\pm0.18{\mu}g/g$, creatinine when air cleaner was no worked. The concentration for $PM_{10},\;NO_2$. and 1-OHP were $13.60\pm10.79{\mu}g/m^3,\; 6.29\pm2.71ppb,\;and\;0.11\pm0.10{\mu}g/g$ creatinine, respectively. It was significant statistically. Therefore, it is considered using the air cleaner to remove the partial pollutants in indoor environment and is positive effect for health.

실내오염물질의 환기기술전략에 따른 영향평가 : 수치적 모델을 이용한 HVAC 시스템의 비교연구 (The Impact of Ventilation Strategies on Indoor Air Pollution: A Comparative Study of HVAC Systems Using a Numerical Model)

  • Park, Sung-Woo;Song, Dong-Woong;D.J. Moschandreas
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제11권E호
    • /
    • pp.45-54
    • /
    • 1995
  • Indoor air quality models are useful to predict indoor air pollutant concentrations as a function of several indoor factors. Indoor air quality model was developed to evaluate the pollutant removal efficiency of variable-air-volume/bypass filtration system (VAV/BPFS) compared with the conventional variable-air-volume (VAV) system. This model provides relative pollutant removal effectiveness of VAV/BPFS by concentration ratio between the conventional VAV system and VAV/BPFS. The predictions agree closely, from 5 to 10 percent, with the measured values for each energy load. As a results, we recommend the VAV/BPFS is a promising alternative to conventional VAV system because it is capable of reducing indoor air pollutant concentration and maintaining good indoor air quality.

  • PDF

확률론적 모의실험을 이용한 공기청정기의 실내공기중 PM10과 $NO_2$ 제거효율에 관한 연구 (Efficiency of Removal for PM10 and $NO_2$ by Air Cleaner in Residential Indoor Environment with Monte-Carlo Simulation)

  • 이철민;김윤신;이태형;김종철;김중호
    • 한국환경보건학회지
    • /
    • 제30권3호
    • /
    • pp.221-229
    • /
    • 2004
  • We estimated decreasing rate of indoor air pollutants which are PM10 and $NO_2$ by the air cleaner in indoor environment. This study respectively examined concentration of PM10 and $NO_2$ two times in 34 sites located in Seoul and Kyung-gi Do from April to September in 2003. Sectional period was respectively divided for operating the air cleaner and non-operating the air cleaner. Moreover, questionnaire was executed to grasp physical characteristic of objective building and residential characteristic of residents by using method of self-entry. There was a trend that concentration of PM10 and $NO_2$ separated number of residents during operating period respectively decreased among indoor air. According to the existence of smoker in indoor, both concentration of PM10 and $NO_2$ during operating period decreased in each case, and according to existence of pets, both cases decreased concentration of pollutants by operating the air cleaner. We used Monte-Calro simulation to remove uncertainty and identify efficiency of eliminated pollutants such as PM10 and $NO_2$ by the air cleaner. Average efficiency of removal for PM10 and $NO_2$ were 61.84${\pm}$23.04% and 48.67${\pm}$18.03% respectively.

아파트 전면발코니의 실내환경 조절효과 및 공간기능 -전면발코니를 실내공간과 통합개조한 경우와의 비교- (Residents' Responses on Indoor Environmental Efficiency and Spatial Function of Front Balcony in Apartments)

  • 최윤정
    • 대한가정학회지
    • /
    • 제42권5호
    • /
    • pp.93-106
    • /
    • 2004
  • The purpose of this study is to make clear the indoor environmental efficiency and spatial function of the front balcony in apartments using responses from residents'. An interview survey carried out during the 14/sup th/∼24/sup th/ of January 2003, and a questionnaire survey was given during the 17/sup th/∼29/sup th/of January. Interviewees consisted of 31 residents living in renovated apartments, which had the front balcony added onto the living room. The respondents of the questionnaire survey consisted of 37 residents living in ordinary apartments with an existing front balcony. The residents living in ordinary apartments show relatively positive responses on the indoor thermal environment during winter, glare by daylight, and outdoor noise. The average heating charges of the renovated apartments came out to be more expensive than the ordinary apartments. In most renovated apartments, the living area converted from front balcony was used as the same functions ('space for drying the laundry', 'storage space', or 'space for cultivating of flower pots') of ordinary front balcony. From the results of this study, it is undesirable to renovate the front balcony as an addition to the livingroom.

건축자재의 산화티타늄 코팅을 통한 휘발성 유기화합물 분해 (Destruction of Volatile Organic Compounds Using Photocatalyst-Coated Construction Materials)

  • 조완근;전희동
    • 한국환경과학회지
    • /
    • 제14권8호
    • /
    • pp.785-792
    • /
    • 2005
  • In order to reduce roadside and indoor air pollution for volatile organic compounds VOC), it may be necessary to apply photocatalyst-coated construction materials. This study evaluated the technical feasibility of the application of $TiO_2$ photocatalysis for the removal of VOC present in roadside or indoor air. The photocatalytic removal of five target VOC was investigated: benzene, toluene, ethyl benzene and o,m,p-xylenes. Variables tested for the current study included ultraviolet(UV) light intensity coating materials, relative humidity (RH), and input concentrations. Prior to performing the parameter tests, adsorption of VOC onto the current experiment was surveyed, and no adsorption was observed. Stronger UV intensity provided higher photocatalytic destruction(PCD) efficiency of the target compounds. For higher humidity, higher PCD efficiency was observed. The PCD efficiency depended on coating material. Contrary to certain previous findings, lower PCD efficiencies were observed for the experimental condition of higher input concentrations. The current findings suggested that the four parameters tested in the present study should be considered for the application of photocatalyst-coated construction materials in cleaning VOC of roadside or indoor air.

대전광역시 주택 실내 라돈 농도 분포와 저감 공법 적용 연구 (A Study on the Distribution and Reduction Method of Indoor Radon Concentration in Daejeon Metropolitan City)

  • 장용철;양재환;김홍경;이가인;송하균;김병환;권영선
    • 환경영향평가
    • /
    • 제31권5호
    • /
    • pp.286-295
    • /
    • 2022
  • 본 연구에서는 대전광역시 실내 라돈의 농도 분포를 조사하고 라돈 저감 공법을 적용하여 저감 효율을 평가하였다. 전국주택라돈조사 결과를 기초로 선별된 24개 주택을 대상으로 실내 라돈 측정을 실시한 결과, A자치구의 평균치가 261 Bq/m3로서 기준치를 크게 상회하는 수준임을 알 수 있었고, 동일한 주택에서도 실내 라돈 농도는 측정 지점과 시간에 따라 영향을 받고 있음을 확인하였다. 라돈 저감을 위해 토양 배기법을 적용한 8개 주택의 경우, 실내 라돈 수치는 기준치에 비해 크게 낮아졌으며 평균 저감 효율 역시 55% 정도로 나타나 양호한 라돈 저감 효과를 알 수 있었다. 또한 차폐법을 실시한 2개의 주택에서는 평균 저감 효율이 90% 정도로서 실내 라돈 저감 효과가 매우 우수하였다. 라돈 저감 시 동일한 저감공법을 적용하여도 건물의 구조, 환기의 빈도, 계절 등 여러 요인에 따라 저감 효율이 달라질 수 있으므로 향후 다양한 인자를 반영하여 저감공법의 효과를 정밀하게 평가할 필요가 있다. 이를 기초로 하여 라돈 노출에 의한 인체 위해 저감을 위한 대전광역시 실내 라돈 관리 대책 마련이 필요하다.

저농도 실내공기 정화를 위한 염소화 및 방향족 탄화수소의 광촉매 분해 (Photocatalytic Destruction of Chlorinated and Aromatic Hydrocarbons for Low-Level Indoor Air Cleaning)

  • 조완근;권기동;최상준;송동익
    • 한국환경과학회지
    • /
    • 제13권9호
    • /
    • pp.767-777
    • /
    • 2004
  • This study evaluated the technical feasibility of the application of $TiO_2$ photocatalysis for the removal of volatile hydrocarbons(VHC) at low ppb concentrations commonly associated with non-occupational indoor air quality issues. A series of experiments was conducted to evaluate five parameters (relative humidity (RH), hydraulic diameter (HD), feeding type (FT) of VHC, photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) for the PCO destruction efficiencies of the selected target VHC. None of the target VHC presented significant dependence on the RH, which are inconsistent with a certain previous study that reported that under conditions of low humidity and a ppm toluene inlet level, there was a drop in the PCO efficiency with decreasing humidity. However, it is noted that the four parameters (HD, RM, FT and IPS) should be considered for better VHC removal efficiencies for the application of $TiO_2$ photocatalytic technology for cleansing non-occupational indoor air. The PCO destruction of VHC at concentrations associated with non-occupational indoor air quality issues can be up to nearly 100%. The amount of CO generated during PCO were a negligible addition to the indoor CO levels. These abilities can make the PCO reactor an important tool in the effort to improve non-occupational indoor air quality.