• Title/Summary/Keyword: indoor clothing

Search Result 63, Processing Time 0.02 seconds

A Study on the Activity and Training Plan of a Field Crew for the Design of Training Scenarios Assuming Chemical Accidents and Terrorism (화학사고·테러를 가정한 훈련 시나리오 설계를 위한 현장 대원의 활동성 분석과 훈련방안에 관한 연구)

  • Kim, Si-Kuk;Choi, Su-Gil;Hong, Sung-chul
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.72-85
    • /
    • 2020
  • This article is a study on the activity of rescue workers for designing simulation training scenarios assuming chemical accidents. On the basis of the complexity of the indoor scene in the case of chemical accidents and terrorism, we designed a 12-step simulation training scenario for two teams to analyze the improvement in firefighters' capabilities. On the basis of activity measurement in the simulation scenario, step 2 of training had the most drops in the maximum heart rate, as follow: N1, from 163 bpm to 153 bpm; N2, from 186 bpm to 151 bpm; N3, from 168 bpm to 162 bpm; and N4, from 166 bpm to 152 bpm. In terms of intensity level in the allowable activity time, it was found that in step 2 both N1 and N2 reduced from Level 5 to Level 3, N3 remained at Level 4, N4 reduced from Level 4 to Level 3, and the maximum allowable activity time increased.

A Study on Evaluation of LED Lighting Environments for Energy Saving and Work Effectiveness (에너지 저감과 업무 효율성을 위한 LED 조명환경 평가에 대한 연구)

  • Kim, Hyung-Sun;Lim, Jae-Hyun;Lee, Kee-Sun;Kim, Kil-Hee;Jung, Hee-Chang;Kim, Jin Ho
    • Science of Emotion and Sensibility
    • /
    • v.18 no.2
    • /
    • pp.45-54
    • /
    • 2015
  • This study carried out an experiment to identify subject's work effectiveness and energy saving effect using LED light. Towards this end, this study configured nine various lighting environments in order to control PWM (Pulse Width Modulation) and illuminance (lux), which are the characteristics of LED light. The PWM ratio of LED light was set as R:G:B=1:1:1, R:G:B=4:1:5, and R:G:B=8:7:7, respectively, and illuminance (lux) was set as 400 lx, 700 lx, and 1000 lx, respectively. In addition, the indoor environment was set temperature $20-24^{\circ}C$, humidity 50%-60%, and the amount of clothing 1. This study analyzed work effectiveness and energy consumption in nine lighting environments, each. Error correction was performed for work effectiveness analysis, and cumulative power consumption was measured in each lighting environment for energy consumption analysis. According to experiment results through the lighting environments suggested in this study, accuracy and spent time effectiveness were good in 700lux and higher than 400lux. For spent time, the best effectiveness was revealed in the suggested PWM ratio, R:G:B=8:7:7. The lowest power consumption on each illuminance (lux) was revealed in the order of R:G:B=8:7:7, RGB=1:1:1, and R:G:B=4:1:5. Therefore, pulse-width modulation effect is proposed in this paper was found to affect the efficiency and energy saving.

A Study on Reinforcement of Fire Safety in Residential Spaces of Low-Income Classes (저소득계층 주거 공간 화재안전성 강화를 위한 연구)

  • Park, Nam-Kwon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.882-889
    • /
    • 2021
  • Purpose: The purpose of this study was to improve fire safety in Gosiwon, a residential space for the low-income class. Method: Problems appearing in the process of fire occurrence and damage were verified once again. In addition, we would like to suggest improvement measures through systematic discussions on blind spots. Results: As a result of examining the risk of cool fire, the causes of fire occurred in various ways. In addition, the possibility of radiant heat due to heat accumulation due to narrow rooms inside the Gosiwon was high. Also, it was found that the possibility of fire spread was high due to clothing and household goods. It was reconfirmed that the poor internal structure of a narrow indoor space had a significant effect on the spread of fire and the scale of damage as it tried to accommodate as many people as possible inside. Conclusion: It is necessary to complete the installation as soon as possible for Gosiwon where the simple sprinkler is not installed. For this, a stronger driving force from the government and local governments is needed. In addition, it will be necessary to discuss how to improve the spatial and structural fire vulnerabilities that appear due to the structural characteristics of the Gosiwon.