• 제목/요약/키워드: indoor cleaning

검색결과 117건 처리시간 0.028초

실내화, 책상, 책가방의 위생학적 고찰 (A Bacteriological Study on the Indoor-Shoes, Desk and Bag of Student의s)

  • 공동
    • 한국환경보건학회지
    • /
    • 제4권1호
    • /
    • pp.26-33
    • /
    • 1977
  • A bacteriological research of the school desks, bags and indoor-shoes was made from Oct. 2, 197 through May 28, 1976. The research included one girl's middle school, two boy's middle schools, two boy's high schools and 15 girl's high schools, alltogether 244 students from 28 schools, The research was analyzed and the results are as follows: 1) The research showed that 95% of the indoor-shoes materials were of cloth. Only 13% of the students carried the indoor-shoes in shoes sacks and 84.8% of them kept the shoes in schoolbags with books and lunchbox. 2) Only 5% of them cleaned their shoes every week and 79% cleaned every six. 3) 49.3% of the students kept the indoor-shoes in the school bag with other contents at home. 4) 88% of the bag was made of vinyl and 24.8% of the students carried their lunch in their bag without lunch box. 5) The research showed that 79.1% of the students never cleaned their bags. 6) In using the desk drawer, 58.2% of the students put their out-door shoes into the drawer, 18.9% of them kept their lunch in it, 11.9% used it keeping books alone and 11% keeping school bags with books. 7) 30.4% of the students had an experience of having cleaned their desks and 69.6% were unconcerned wirh desk-cleaning. 8) 34.4% of the indoor-shoes using school showed fecal coliform positive, 40.2% showed non-fecal coliform positive and 25.4% showed no reaction to IMViC. 9) The 34.4% of the fecal coliform positive showing schools, equivalant to 77 students, was composed of zero percents of girl's middle school, 18.2% of girl's high school, 36.4% of boy's middle school and 45.4% of boy's high school. 10) Among the 77 students, whose shoes showed fecal coliform positive, only 6.5% of them cleaned their shoes once in a week or a month and 62.3% of them cleaned them once in a six month. 11) The fccal coliform positive rate was higher in the cloth shoes materials than the vinyl materials. 12) The concrete-bottomed building higher positive rate (40.2%) than the wood-bottomed building (7.5%). 13) Even among the student's who frequently cleaned their desk drawer, 2.3% were in the positive, and among those who were unconcerned with drawer cleaning, 48.9% were involved in the positive. 14) In the fecal coliform positive rate of bags, 38.5% of the positive rate belonged to using indoor shoes while cleaning their class bottom with water, 53.8% belonged to using outdoor shoes while cleaning their class bottom with water, 7.7% belonged to using outdoor shoes while cleaning their class with oil.

  • PDF

지하철 역사의 실내공기질 개선을 위한 공조기 적용 공기청정장치 선정에 대한 기초연구 (Study of HVAC system with air cleaning system for indoor air quality of subway station)

  • 정의경;박재홍;이양화;윤기영;황정호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.537-540
    • /
    • 2008
  • A numerical study has been carried out on the optimization of an air cleaning system which was installed in a heating, ventilation and air conditioning system (HVAC) system of subway station for particle removal. Required particle removal efficiencies of three different air cleaning systems were calculated from ventilation rate, and indoor/outdoor concentration of PM10. Mass balance equations of PM10 were used to solve the required particle removal efficiencies. Fibrous filter was considered as an air cleaning system. Calculations were carried out about two different places which were waiting area and platform of subway station, respectively. This study proposed optimized design and operation condition of each air cleaning system.

  • PDF

지하철 공기청정을 위한 2유체노즐형 자동세정 공기청정 시스템 개발에 관한 연구 (Performance Evaluation of Automatic Self-Cleaning Filter System using Twin-Fluid Nozzles for Air Cleaning in the Subway Stations)

  • 안영철;이재근
    • 한국분무공학회지
    • /
    • 제9권3호
    • /
    • pp.15-21
    • /
    • 2004
  • The removal of the dusts in the subway stations, tunnels, factories and buildings becomes issue for comfortable indoor and outdoor conditions. There has been used an automatic self-cleaning filter system to collect the dusts. In general, the collected particles are removed by water spray nozzles. The new design for improving the cleaning efficiency of collected dusts and reducing the supplied water is the concept of the plane array of demister filters and the twin-fluid nozzle for mixing compressed air and water in the automatic self-cleaning filter system. Results show that the cleaning efficiency of twin-nozzle filter systems is 99.1%, compared to 47% in the conventional filter system. Therefore the automatic self-cleaning filter system using twin-fluid nozzle filter systems reduces water supplied in the filter system, and increases cleaning efficiency and drying efficiency.

  • PDF

아파트 실내공기질 현장측정에 의한 전열교환 청정환기유니트 성능평가 (IAQ Field Survey in an Apartment Housing Equiped for Heat Recovery Ventilation System with Air Cleaning Function)

  • 이정재;이중훈;이승민
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.688-693
    • /
    • 2005
  • Nowaday the natural ventilation rate decreases because the apartment housing is being air-tight. Therefore, Indoor Air Quality (IAQ) and indoor environment grow worse. Especially, Formaldehyde (HCHO), Volatile Organic Compounds (VOCs) which is emitted from the building materials and coating material etc. occur Sick House Syndrome that cause negative impact on resident's respiratory system and body. Therefore in construction field, it will be a important issues that development of a ventilation system with high effectiveness which can exhaust the contaminant out of the building quickly. In this research we evaluated 'wall attachable duct-less Heat Recovery Ventilation (HRV) system with air cleaning function'. We executed a synthetic evaluation about indoor air environment under various operating condition installing the system in real scale apartment house that is built in Anyang city. HRV system with air cleaning function showed good performance by removing HCHO, VOCs with less ventilation energy.

Indoor Emission Characteristics of Liquid Household Products using Purge - and - Trap Method

  • Kwon, Ki-Dong;Jo, Wan-Kuen
    • Environmental Engineering Research
    • /
    • 제12권5호
    • /
    • pp.203-210
    • /
    • 2007
  • Since the emissions composition from the household products have potentially been associated with health risks for building occupants, the chemical composition emitted from the products should be surveyed. The current study identified the emission composition for 42 liquid household products, using a purge-and-trap method. This evaluation was done by classifying the household products into five product classes (deodorizers, household cleaners, color removers, pesticides, and polishes). Nineteen compounds were chosen on the basis of selection criteria. The quality control program for purge-and-trap and analytical systems included tests of laboratory blank Tenax traps and blank water samples, and the determination of calibration equation, measurement precision, method detection limit (MDL), and recovery. The number of chemicals varied according to the product categories, ranging from 4 for the product category of bleaches to 12 for the product categories of air fresheners and nail color removers. For all product categories, the emission composition and concentrations varied broadly according to product. It is noteworthy that most household products emit limonene: 19 of 25 cleaning products; 5 of 6 deodorizers; 1 of 3 pesticides; 3 of 3 color removers; and 4 of 5 polishes. It was suggested that the use of household products sold in Korea could elevate the formation of secondary toxic pollutants in indoor environments, by the reaction of limonene with ozone, which entered indoor environments or might be generated by indoor sources such as electronic air cleaning devices and copying machines.

공동주택에서 환기장치류 가동특성에 따른 실내공기질 변화특성에 관한 연구 (The Effects to Indoor Air Quality as Ventilation System Operation in Apartment House Using CFD Simulation)

  • 김석근;이정재
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.142-148
    • /
    • 2007
  • The purpose of this study is to suggest the effective ventilation strategies and control methods that can minimize energy cost maintaining acceptable IAQ level in apartment house. The effects of the air-cleaning and heat-recovery ventilation system on IAQ under various operating conditions are investigated based on the experimental and CFD analyzed results. The results can be summarized as follows. (1) When a ventilator is not operated, the concentration of several pollutants may highly show in the house even though environment-friendly building materials are applied. Therefore, a mechanical ventilation system is required to obtain proper ventilation. (2) The pollutant concentration is noticeably deceased under air-cleaning/ventilation mode of air-clinic system, however, pollutant of kitchen is stagnant, because fresh air is not carried into the kitchen. (3) When air-clinic system is only equipped at master bedroom and living room, the system does not effectively deliver fresh air throughout the whole house, and then high pollutant concentration is obtained in each room. In contrast the average pollutant concentration meets the guideline when air-clinic system is installed at each room. (4) The air-cleaning/ventilation mode significantly affects on room ventilation in comparison with ventilation mode only.

겨울철 고등학교 교실에서 재실자의 환경조절행동이 공기환경 개선에 미치는 영향 (Effect of Occupants' Behaviour of Environmental Control on Improvement of Air Environment in Winter's High School Classroom)

  • 곽노열
    • 대한건축학회논문집:구조계
    • /
    • 제36권4호
    • /
    • pp.163-172
    • /
    • 2020
  • In this study, the effect of window opening, which is a control mechanism for air control in winter high school classrooms, on the change in air and indoor environment of the classroom was analyzed and physical conditions of indoor and air environment were observed during the classroom course, and satisfaction of the students and teachers was assessed with questionnaires. And the changes in air environment were assessed by the performance of the duster cleaning work in the classroom. It was found that 84.6% of the students surveyed said the air was stuffy. And among the alternatives, opening windows all times during class was most effective in reducing CO2 concentration and PM concentration was measured within classroom's standard. In addition, the concentration change rate of duster cleaning work was reduced by 74.4% and 65.4% of PM10 compared to broom cleaning work.

Exposure Assessment of Airborne Bacteria and Fungi in the Aircraft

  • Doo-Young Kim;Ki-Youn Kim
    • Safety and Health at Work
    • /
    • 제13권4호
    • /
    • pp.487-492
    • /
    • 2022
  • Objective: The exposure levels of disease-causing bacteria and germs were assessed on aircraft cleaning workers on multiple different aircrafts. Method: Five measuring points were selected depending on the aircraft types. Four aircraft cleaning agencies were selected for the test. Aircraft cleaning work was classified as intensive cleaning and general cleaning work. Ventilation in aircraft when sampling during the cleaning operation was categorized into forced ventilation and natural ventilation. The collection of airborne microorganisms was made through inertial impactors which were installed 1.5 meters above the bottom of the aircraft. The airborne bacteria and fungus growth badges were selected by Trytpic Soy Agar and Sabouraud Dextrose Agar. Results: The average concentrations of bacteria in the air were higher in the order of small, medium, and large airplanes. Rainy days had higher concentrations inside and outside the aircraft as compared to those in sunny days. Regarding ventilation, concentrations in natural ventilation were higher than concentrations in forced ventilation. According to the type of work, the concentrations in the intensive cleaning groups (cleaning one plane a day) were lower than those of the ordinary cleaning groups (cleaning several planes per day). Conclusion: The concentration levels of airborne bacteria and fungi in the aircraft surveyed were lower than the indoor environmental standards of Korea (800 cfu/m3 and 500 cfu/m3). The average concentrations of bacteria in the air and fungi in the air were highest in small aircraft owned by Company D.

인공신경망 기반 공기정화기 설치위치에 따른 공기교환성능 예측 (Prediction of Air Exchange Performance of an Air Purifier by Installation Location using Artificial Neural Network)

  • 김나경;강동희;강현욱
    • 한국가시화정보학회지
    • /
    • 제20권2호
    • /
    • pp.21-27
    • /
    • 2022
  • Air purifiers can be placed where the air cleaning is required, making it easy to manage indoor air quality. The position of the air purifier affects the indoor airflow pattern, resulting in different air cleaning efficiency. Many efforts and strategies have been examined through numerical simulations and experiments to find the proper location of the air purifier, but problems still remain due to the various geometrical indoor spaces and arrangements. Herein, we develop an artificial intelligence model to predict the performance of an air purifier depending on the installation location. To obtain the training data, numerical simulations were performed on the different locations of the air purifiers and airflow patterns. The trained artificial intelligence model predicted the air exchange performance depending on the installation location of the air purifier with a prediction accuracy of 92%.

청소로봇의 최적비용함수를 고려한 지도 작성에 관한 연구 (A Study on the Map-Building of a Cleaning Robot Base upon the Optimal Cost Function)

  • 강진구
    • 디지털산업정보학회논문지
    • /
    • 제5권3호
    • /
    • pp.39-45
    • /
    • 2009
  • In this paper we present a cleaning robot system for an autonomous mobile robot. Our robot performs goal reaching tasks into unknown indoor environments by using sensor fusion. The robot's operation objective is to clean floor or any other applicable surface and to build a map of the surrounding environment for some further purpose such as finding the shortest path available. Using its cleaning robot system for an autonomous mobile robot can move in various modes and perform dexterous tasks. Performance of the cleaning robot system is better than a fixed base redundant robot in avoiding singularity and obstacle. Sensor fusion using the clean robot improves the performance of the robot with redundant freedom in workspace and Map-Building. In this paper, Map-building of the cleaning robot has been studied using sensor fusion. A sequence of this alternating task execution scheme enables the clean robot to execute various tasks efficiently. The proposed algorithm is experimentally verified and discussed with a cleaning robot, KCCR.