• Title/Summary/Keyword: indoor air pollutants

Search Result 308, Processing Time 0.027 seconds

A Development of Coupled Simulation Tool to Evaluate Performance of Ventilation System (환기시스템의 성능평가를 위한 통합 시뮬레이션 Tool의 개발)

  • Cho Wang-Hee;Song Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.112-121
    • /
    • 2006
  • To evaluate the performance of ventilation system properly, the correlations among the ventilation rate, indoor air-quality and cooling/heating load should be analysed. In this study, simulation tool to analyze the performance of ventilation system was developed. The simulation tool is based on the TRNSYS and some modules to calculate concentration of pollutants with the operation of ventilation system and to decide the signal of ventilation system were newly developed in this study. And these modules coupled with building load and heating/cooling simulation modules. To verify the validity of developed simulation tool, comparison study between simulation and field study were accomplished. As results, the simulation tool developed in this study can be used to predict the performance of ventilation system with accuracy.

Influence of Ventilation on the Subway Radon Level (환기에 의한 지하 역의 라돈농도 변화)

  • 박덕신;정우성;정병철
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.2
    • /
    • pp.62-67
    • /
    • 2000
  • Modern people stay at indoor places about 90% of a day. Radon-222 is a gas produced by the radioactive decay of the element radium. And, radon is one of the major indoor air pollutants. Radon moves into the underground space through various routes and is considered to cause lung cancer by hurting the lung tissues. In this study, we measured the subway radon level at 9 stations of 3 lines. According to test results, we can figure out the concentration of radon by lines, times, and measuring points. So, it was found that ventilation conditions are the most important factors in the subway air quality. Finally, we suggested effective and economic management methods of air pollution in the subway.

  • PDF

Study on the Control Performance Evaluation of the Exhaust Stack used in High Riser Public House (초고층공동주택 국소배기용 입상덕트시스템의 제어성능평가에 관한 연구)

  • Kwon, Yong-Il;Ahn, Jung-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.2
    • /
    • pp.103-108
    • /
    • 2009
  • Local exhaust system used in toilet and cooking place of low-rise public house installed roof ventilator at terminal of stack. There are many high riser public houses in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser public house depends on stack effect. But Neutral pressure level represents in a terminal of stack with air tightness for the best exhaust efficiency. Thereby, lower floors have the worst indoor air quality. This paper focuses mainly on the exhaust efficiency improved by roof fan with motor installed in high riser public house. It is observed there is higher exhaust efficiency than the existing natural roof ventilator.

Status of particulate matter pollution in urban railway environments (도시철도 환경의 미세먼지 오염 현황)

  • Kim, Jong Bum;Lee, Seung-Bok;Bae, Gwi-Nam
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.303-314
    • /
    • 2018
  • The urban railway system is a convenient public transportation system, as it carries many people without increasing traffic congestion. However, air quality in urban railway environments is worse than ambient air quality due to the internal location of the source of air pollutants and the isolated space. In this paper, characteristics of particulate matter (PM) pollution in urban railway environments are described from the perspective of diurnal variation, chemical composition and source apportionment of PM. PM concentrations in concourse, platform, passenger cabin, and tunnel are summarized through an analysis of 34 journal articles published in Korea and overseas. This information will be helpful in developing effective policies to reduce PM pollution in urban railway environments.

Reduction Methods of Indoor hiy Quality on the Subway Station using by Ventilation (환기를 이용한 지하 역 실내 공기질 개선 방안)

  • 박덕신;정병철;조준호;정우성
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.139-146
    • /
    • 2001
  • Modern people stay at indoor places about 90% of a day. Radon-222 is a gas produced radioactive decay of the element radium. And, radon is one of the major indoor air pollutants moves into the underground space through various routes and is considered to cause lung c hurting the lung tissues, In this study, we measured the subway radon level at 9 stations o According to test results, we can figure out the concentration of radon by lines, times, and m points. So, it was found that ventilation conditions are the most important factors in the su quality. Finally, we suggested effective and economic management methods of air pollution subway.

  • PDF

Characteristics of concentration distribution for indoor air pollutants (VOCs and Carbonyl compounds) in new apartments (신축 공동주택에서 실내공기오염물질(휘발성유기화합물 및 카보닐화합물) 농도분포 특성)

  • Jang, Seong-Ki;Chun, Jae-Young;Lee, Tae-Young;Lim, Soo-Gil;Lu, Jung-Min;Seo, Soo-Yun;Lim, Jeong-Yun
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.17-24
    • /
    • 2007
  • This study was performed to investigate the distributions of volatile organic compounds and carbonyl compounds at the 120 households in new apartments before occupation. The concentration of toluene, m, p-xylene, formaldehyde, acetone and ethylbenzene dominated as $272.81{\mu}g/m^3$, $98.90{\mu}g/m^3$, $71.68{\mu}g/m^3$, $70.58{\mu}g/m^3$ and $49.76{\mu}g/m^3$, respectively. The identified compounds by standards occupied 42.5% of the TVOCs, also the concentration of toluene occupied the largest part of the identified compounds as 18.5%. The concentration of formaldehyde and acetone were 43.1% and 42.4% among carbonyl compounds. The indoor/outdoor ratio of the concentration of benzene, toluene, formaldehyde and o-xylene were investigated 1.29, 3.59, 10.76 and 28.74, respectively.

Air Cleaning Unit using Combination of $TiO_2$ Photocatalyst and Pulsed Discharge Plasma (산화티타늄 광촉매와 펄스 방전 플라즈마 조합에 의한 공기정화장치)

  • Hong, Yeong-Gi;Sin, Su-Yeon;Gang, Jeong-Hun;Lee, Seong-Hwa;Jo, Jeong-Su;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.10
    • /
    • pp.710-715
    • /
    • 1999
  • The purpose of this work is to develop a high-efficiency air cleaning system for air pollutants such as particulate and gaseous state in indoor environments. In order to enhance a removal efficiency of gaseous state pollutants, we suggested that pulsed discharge plasma be combined with $TiO_2$ photocatalyst (photocatalytic plasma air cleaning unit). We investigated experimentally the basic characteristics of photocatalytic plasma air cleaning unit and measured air pollutants removal efficiency. The wavelength of light radiated from pulsed discharge plasma under the atmospheric condition was 310~380nm. Its energy is enough to excite the $TiO_2$ photocatalyst and it makes a photochemical reaction in the surface of $TiO_2$ photocatalyst. The removal quantity of trimethylamine$((CH_3)_3N)\; was\; 130mg/m^34 which is twice quantity of pulsed discharge plasma without $TiO_2$ phtocatalyst unit. From the result of gas analysis using FT-IR, nitric oxide was not detected and trimethylamine was decomposed to $H_2O\; and \;CO_2$. And trimethylamine removal efficiency was 95%. These experimental results indicate that photocatalytic plasma air cleaning unit is a potential method in removing the pollutants.

  • PDF

Study on Adsorption of Carbon Dioxide in Cabin Using Chamber (챔버를 이용한 객실 이산화탄소 흡착 연구)

  • Cho, Young-Min;Lee, Ji-Yun;Choi, Jin-Shik;Kwon, Soon-Bark;Park, Duck-Shin;Kim, Hee-Man
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1309-1314
    • /
    • 2011
  • People spend approximately 80 ~ 90 % of their time in various kinds of indoor spaces. And, in metropolitan area, most people spend more than 1 hour in public transportation everyday. For this reason, people's interest in the indoor air quality is drastically increasing. Among various indoor air pollutants, $CO_2$ is one of the most severe environmental concerns. Ventilation is commonly used to keep low $CO_2$ concentration in the passenger cabin. However, ventilation may worse the indoor air quality problem in case of subway because the tunnel is seriously polluted by particulate matters. In this study, an alternative way to remove $CO_2$ was suggested. The adsorption of $CO_2$ by $CO_2$ adsorbent was studied. Zeolite modified with base was prepared, and $CO_2$ removal performance was tested in $4m^3$ and $24m^3$ environmental chambers. It was found that $CO_2$ adsorbent could effectively remove $CO_2$ in the chambers.

  • PDF

Studying indoor contaminant value according to vary ventilation and humidity, when operating bake-out on a new apartment (신축 공동주택 베이크 아웃시 환기.습도 변화에 따른 실내오염물질 저감비교)

  • Cho, Yeon-Hyo;Shin, Sung-Woo;Lee, Ji-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.702-707
    • /
    • 2008
  • Improving quality of life and wellbeing of the residential environment and increased interests and importance is growing confidentiality, insulation, high-rise due to a lack of ventilation and indoor air pollution. Several human diseases caused tremendously due to the indoor air which consists of formaldehyde, radon, pollutants such as volatile substances that is called the phenomenon of a new house syndrome. It has become a world-wide issue that the United States, Japan and several other countries of Europe are showing more interests. Furthermore, a lot of damages caused by the syndrome occurs in the new house should be resolved by somehow is urgent. Thus, this study would like to propose the measures based on the whether condition and the way of heating in korea against a new house syndrome via analysis of indoor contaminant Reduction comparison according to vary ventilation and humidity when operating bake-out on a new apartment.

  • PDF

An Experimental Study on Indoor Pollutant Reduction of Cementitious Composite Using Charcoal and Phytoncide (숯과 피톤치드를 사용한 시멘트계 복합재의 실내 오염물질 저감에 관한 실험적 연구)

  • Jeong, Hyeon-Woo;Jeong, We-Young;Jung, Yoong-Hoon;Han, Song-Yi;Park, Sun-Gyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.1
    • /
    • pp.13-19
    • /
    • 2021
  • In modern society, indoor activities time is increasing due to industrial development. Interest in indoor air quality is increasing as indoor activity time increases. The main causes of indoor air pollution are formaldehyde which a chemical cause, and fungi which a biological cause. Phytoncide effectively reduces Formaldehyde and Fungi. Charcoal which possess porous-structure has a good absorbance of pollutants. In this study, the authors manufactured functional cement matrix using by phytoncide and charcoal to remove formaldehyde and fungi. In this study, Functional cement matrix reduced formaldehyde and Fungi and effectively improve indoor air quality.