• Title/Summary/Keyword: indicator & standard

Search Result 408, Processing Time 0.027 seconds

Diagnostic Study of Problems under Asymptotically Generalized Least Squares Estimation of Physical Health Model

  • Kim, Jung-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.5
    • /
    • pp.1030-1041
    • /
    • 1999
  • This study examined those problems noticed under the Asymptotically Generalized Least Squares estimator in evaluating a structural model of physical health. The problems were highly correlated parameter estimates and high standard errors of some parameter estimates. Separate analyses of the endogenous part of the model and of the metric of a latent factor revealed a highly skewed and kurtotic measurement indicator as the focal point of the manifested problems. Since the sample sizes are far below that needed to produce adequate AGLS estimates in the given modeling conditions, the adequacy of the Maximum Likelihood estimator is further examined with the robust statistics and the bootstrap method. These methods demonstrated that the ML methods were unbiased and statistical decisions based upon the ML standard errors remained almost the same. Suggestions are made for future studies adopting structural equation modeling technique in terms of selecting of a reference indicator and adopting those statistics corrected for nonormality.

  • PDF

Supplementation of Regulation on the Offshore Oil Pipeline for Maintenance (해저 송유배관 유지관리를 위한 기준 보완 제시)

  • Kang, Chan-Seong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.8 no.2
    • /
    • pp.70-81
    • /
    • 2012
  • The study aims to supplement facility management plan and safety regulations & standard of oil pipeline by searching and reviewing related regulation & standard inside and outside of the country. Korean regulation & standard is reviewed based on harbor and fishery design standard of the ministry of maritime affairs and fisheries, general technology standard of oil pipeline safety regulation, gas excavation construction and safety maintenance indicator of Korea gas corporation. Global regulation & standard is reviewed based on U.S standard inspection for offshore pipeline and Europe/Mexico standard inspection for offshore pipeline. The contents of offshore pipeline installation is inserted into pipeline sector for objected facilities of safety inspection regulation & standard and, the standard of safety inspection for offshore pipeline is newly presented into pipeline maintenance part of the planning facilities management with its inspection period and method.

  • PDF

Volumetric Determination of a small amount of Iron with Potassium Ferrocyanide (훼로시안化 칼리움에 依한 鐵의 微量適定法)

  • Won, Chong-Hun
    • Journal of the Korean Chemical Society
    • /
    • v.5 no.1
    • /
    • pp.42-47
    • /
    • 1961
  • A titration of a small amount of iron with standard potassium ferrocyanide using potassium thiocyanate as indicator has been studied. A sample solution containing $0.1{\sim}1.0$ mg. $Fe^{3+}$ in 60 ml. is pipeted into 100 ml. Erlenmyer flask and the pH of the solution is adjusted to $1.5{\sim}3.0$ with 0.1 N or 1 N $HNO_3$ and $NH_4OH.$ To this solution one ml. of 1 M KCNS solution as indicator is added. The solution colored by iron thiocyanate complex is titrated with 1/200 M or 1/400 M standard solution of potassium ferrocyanide from a 5 ml. micro-buret. Near the end point, when the color of sample changes from deep red to green, about 20 ml. of ether is added and shake the flask vigorously. The red color is extracted to the ether layer. To settle the ether layer a few drops of ethanol is added and then standard solution is added dropwise and shake vigorously. The end point is reached when the color of the ether layer disappears owing to the quantitative formation of $Fe_4[Fe(CN)_6]_3.$ In this titration, 0.lmg. of $Fe^{3+}$ can be determined within 1.0% of titration error, provided the following optimum conditions, i.e., pH $1.5{\sim}3.0$, final concentration of KCNS indicator; $0.01{\sim}0.02M$, at room temperature. The titration found to be interfered by the presence of slightly soluble salts, stable complex forming ions and the ions which would be reduced by ferrocyanide or oxidized by ferric ion.

  • PDF

Determination of In-focus Criteria In Image Processing Method for Particle Size Measurement (입경측정을 위한 영상처리기법에서 입자 초점면 존재 판단 기준의 설정)

  • Koh, Kwang Uoong;Kim, Joo Youn;Lee, Sang Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.398-407
    • /
    • 1999
  • In the present image processing technique, the concept of the gradient indicator(GI) has been introduced to find out the depth-of-field in sizing large particles ranging from $30{\mu}m$ to $30{\mu}m$ where using of the concept of the normalized contrast value(VC) is not appropriate. The gradient indicator is defined as the ratio of the local value to the maximum possible value of the gray-level gradient in an image frame. The gradient indicator decreases with the increases of the particle size and the distance from the exact focal plane. A particle is considered to be in focus when the value of the gradient indicator at its image boundary stays above a critical value. This critical gradient indicator($GI_{critical}$) is defined as the maximum gradient indicator($GI_{max}$) subtracted by a constant ${\Delta}GI$ which is to account for the particle-size effect. In the present ca.so, the value of ${\Delta}GI$ was set to 0.28 to keep the standard deviation of the measured particles mostly within 0.1. It was also confirmed that, to find the depth-of-field for small particles(${\leq}30{\mu}m$) with the same measurement accuracy, tho concept of the critical normalized contrast($VC_{critical}$) is applicable with 85% of the maximum normalized contrast value($VC_{max}$). Finally, the depth-of-field was checked for the size range between $10{\mu}m$ and $300{\mu}m$ when the both in-focus criteria ($GI_{critical}$ and $VC_{critical}$) were adopted. The change of the depth-of-field with the particle size shows good linearity in both the VC-applicable and the GI-applicable ranges with a reasonable accuracy.

A Study on the Improvement in Statistical Indicator of Public Library (공공도서관 통계지표 항목 설정의 개선방향에 관한 연구)

  • Cho, Hyun-Yang;Kim, Hong-Ryul
    • Journal of Korean Library and Information Science Society
    • /
    • v.43 no.4
    • /
    • pp.427-450
    • /
    • 2012
  • This study was to propose an improvement direction in statistical indicators of public libraries to collect objective data from such libraries. This improvement direction was made by deriving from countable factors at the library. These were selected from various parts of the library sectors, such as the library-related laws, public library standard of our country, and statistical indicators of IFLA and other major countries. Also The these statistical indicator was compared to the current statistical indicator of public library in Korea. The results will be able to develop new draft of statistical indicator, which can be used in understanding the present situation of public libraries.

The Predicton of the Shelf-life of Packaged Meals (Kim Pab) Marketed in Covenience Stores Using Simulation Study (모의실험을 통한 편의점 판매용 김밥 도시락의 유통기한 예측)

  • 곽동경;김성희
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.3
    • /
    • pp.189-196
    • /
    • 1996
  • Based on microbiological-chemical test results under simulated time-temperature conditions, total plate count, coliform, and volatile basic nitrogen were selected as effective quality indicators for estimating probable shelf-life on Kim Pab dosirak marketed in convenience stores, and shelf-life at each storage temperature was calculated from regression equation between effective quality indicator standard limit and storage time. Estimated shelf lives of Kim Pab Dosirak were 17, 3 and 2 hours respectively under 1$0^{\circ}C$, 2$0^{\circ}C$ and 3$0^{\circ}C$. Because shelf-life was especially affected by intial values, regression analysis between initial effective quality indicator values and storage hours was performed for the estimation of probable shelf-life on Kim Pab during storage at 10, 20, or 3$0^{\circ}C$.

  • PDF

Use of Geographic Information System Tools for Improving Atmospheric Emission Inventories of Biogenic Source

  • Shin, Tae-joo
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.3
    • /
    • pp.151-158
    • /
    • 1999
  • Biogenic source emissions refer to naturally occuring emissions from vegetation, microbial activities in soil, lightening, and so on. Vegetation is especially known to emit a considerable amout of volatile organic compounds into the atmosphere. Therefore, biogenic source emissions are an important input to photochemical air quality models. since most biogenic source emissions are calculated at the county-level, they should be geographically allocated to the computational grid cells of a photochemical air quality model prior to running the model. The traditional method for the spatial allocation for biogenic source emissions has been to use a "spatial surrogate indicator" such as a county area. In order to examine the applicability of such approximations, this study developed more detailed surrogate indicators to improve the spatial allocation method for biogenic source emissions. Due to the spatially variable nature of biogenic source emissions, Geographic Information Systems(GIS) were introduced as new tools to develop more detailed spatial surrogate indicators. Use of these newly developed spatial surrogate indicators for biogenic source emission allocation provides a better resolution than the standard spatial surrogate indicator.indicator.

  • PDF

Readmission Rate: Experience in USA, Canada and UK (미국, 캐나다, 영국의 재입원율 활용 현황)

  • Lee, Sang-Ah;Ju, Yeong-Jun;Shin, Jae-Yong;Park, Eun-Cheol;Lee, Hoo-Yeon
    • Quality Improvement in Health Care
    • /
    • v.22 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • Readmission which reflects capacity to manage patients and general level of medical services has been known for one of the causes of medical expenditure due to inefficient service. Compared to disease-specific readmission, hospital wide readmission (HWR) is relatively easy to understand, and has merit to get over limitation of collateral medical services assessment; therefore, a growing interest in development and usage of readmission indicator as quality of care indicator focusing on all-disease is detected. In this study, we investigate current state of risk standardized readmission rate indicator used in the United States, the United Kingdom, and Canada, and examine the considerations when using readmission rate as quality indicator in Korea. Differences in risk-adjustment methods were showed among countries. The United States do not control race not to hide socio-demographic factors on readmission. Canada shows differentiation compared to other countries about reflecting community factors. All three-countries utilize readmission rate as monitoring quality of care rather than incentives or penalty due to the fact that readmission rate could not represent the whole quality of hospital and has a limitation at controlling socio-economic factors. Therefore, for usage readmission rate as quality indicator in Korea, preparing readmission classification standard for Korean medical environment and additional methods for acquiring information by using discharge summary is need. Moreover, continued discussion with clinical specialists is needed for obtain clinical reliability and validity.

Assessing the Appropriateness of the Spatial Distribution of Standard Lots Using the L-index

  • Lee, Sang-Kyeong;Lee, Byoungkil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.6_2
    • /
    • pp.601-609
    • /
    • 2013
  • Standard lots, which are used to assess values of individual lots in Korea, have been criticized for their improper distribution. However, there has been very little evaluation for the spatial distribution of standard lots, and an evaluation method has never been developed. In order to overcome this situation, we attempt to assess the appropriateness of the spatial distribution of standard lots using the L-index and Monte Carlo simulation. The L-index is a well-known indicator of the complete spatial randomness (CSR) of points in spatial statistics. If the L-index of standard lots is similar to that of individual lots, the former is considered to be randomly distributed according to the latter. By analyzing L-indices of two study areas, Gangnam and Seongdong, we find a statistically significant difference in Gangnam area and a relatively small difference in Seongdong area. We confirm that the spatial distribution of standard lots is not CSR and that the L-index is useful as an evaluation method. These results suggest that the standard lot selection and management guidelines need to be modified to apply the spatial distribution of individual lots to the standard lot selection process.