• 제목/요약/키워드: indentation method

검색결과 292건 처리시간 0.026초

균열선단에 링압인 부가에 의한 잔류응력장분포와 피로균열성장지연 (Residual Stress Fields and Fatigue Crack Growth Retardation Induced by Ring-Indentation)

  • 임원균;송정훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.597-602
    • /
    • 2001
  • A method for the retardation of fatigue crack growth using ring indentation at the vicinity of a crack is examined. Residual stresses near crack tip are evaluated using fracture mechanics approach. The motivation is to develop a simple and effective method for obtaining an increase in fatigue lives to total failure of materials with crack. Fatigue testing of aluminum specimen showed that the retardation effects are observed after the application of the method.

  • PDF

링압인을 이용한 피로균열의 성장지연효과 (Fatigue Crack Growth Retardation Using Ring Indentation)

  • 임원균;송정훈
    • 한국항공우주학회지
    • /
    • 제31권10호
    • /
    • pp.27-33
    • /
    • 2003
  • 균열주위에 링압인을 부가함으로서 피로균열을 지연하는 수법을 제시하였다. 균열주위의 잔류응력분포는 Bueckner가중함수를 이용한 파괴역학적 수법으로 평가하였다. 본 연구는 균열을 가진 재료에 대한 파단시까지의 피로수명을 향상시키기 위한 단순하면서도 표과적인 수법을 개발하는데 있다. 알루미늄재료에 대한 피로실험결과 본 수법이 피로지연효과를 효율적으로 얻을 수 있는 것으로 나타났다.

압전효과를 이용한 압인방식의 휴대용 피부탄력 측정장치 (A Portable Skin Elasticity Measuring Device Based on Indentation Method Using Piezoelectric Effect)

  • 박준영;김명남
    • 한국멀티미디어학회논문지
    • /
    • 제25권9호
    • /
    • pp.1307-1315
    • /
    • 2022
  • In this paper, we proposed and developed a new portable skin elasticity measuring device based on the indentation method using piezoelectric effect. The proposed device is designed to minimize the uncertainty caused by the layer structure of the skin when measuring the elasticity of the skin. And, we developed a piezoelectric-based thin-film pressure sensor that can measure quantitatively and quickly during repeated measurement as a device sensor. To confirm the effectiveness of the proposed measuring device, it was compared with the experimental results of the conventional measuring devices under the same experimental conditions, and statistical correlation analysis was performed between the experimental data of the proposed measuring device and the experimental data of the conventional measuring devices. As a result of the correlation analysis, it was confirmed that the proposed measuring device had a high correlation with the conventional measuring devices. Therefore, it was confirmed that the proposed skin elasticity measuring device was effective.

압자압입법에 의한 치과용 도재의 파괴인성 평가 (AN EVALUATION OF FRACTURE TOUGHNESS OF DENTAL CERAMICS BY INDENTATION FRACTURE METHOD)

  • 안승근;이주형;배태성
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.309-319
    • /
    • 1996
  • This study was performed to evaluate the fracture toughness of seven commercially available dental ceramics by indentation fracture method. All specimens were fabricated to the final dimensions of approximately 12mm in diameter 2mm in thickness. The characte-ristic indentation dimensions of Vickers or Knoop indentation were measured to calculate the fracture toughness values and Young’s moduli. The results obtained were summarized as follows; 1. Young’s modulus and Vickers hardness of Vita In-Ceram showed the maximum values of $154.4{\pm}49.2$ Gpa and $12.60{\pm}0.71$Gpa, respectively. Results of Scheff test exhibited the significant difference between Vita In-Ceram group and others(p<0.01). 2. Maximum fracture toughness of $2.562{\pm}0.37 MPam^{1/2}$ for Vita In-Ceram and the maxi-mum one of $0.908{\pm}0.132MPam^{1/2}$ for Vitadur-N were calculated. Results of Scheff test showed the significant difference between Vita In-Ceram group and Vita Hi-Ceram(p<0.05) : also between Vita In-Ceram or Vita Hi-Ceram and others(p<0.01). 3. The alumina-based core ceramics showed the aspect of Palmqvist crack for the indentation load of 49.0N, but others showed the median/lateral crack for the indentation load of 9.8N.

  • PDF

코디어라이트-SiC위스커 복합재료에서 측정방법에 따른 파괴인성치의 변화 (Influence of Testing Method on the Fracture Toughness of Cordierite-SiC Whisker Ceramic Composites)

  • 강대갑
    • 한국세라믹학회지
    • /
    • 제24권4호
    • /
    • pp.313-320
    • /
    • 1987
  • Fracture toughness of hot pressed cordierite-SiC whisker ceramic composites contained up to 40vol.% SiC whiskers were determined by using the indentation crack length(IC), indentation strengthin-bending(IS), and single-edge notched-beam(SENB) methods. The results were compared to stress intensity factor, KB, at the crack branching boundary measured by using the mirror zone radius (MZ) method. IS method seems to provide a more reasonable estimation of fracture toughness than other methods for these composites.

  • PDF

인간공학적 좌석평가를 위한 좌면 형상 변형측정에 관한 연구 (A new seat surface deformation measurement method for ergonomic seat evaluation)

  • 이남식
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1990년도 춘계공동학술대회논문집; 한국과학기술원; 28 Apr. 1990
    • /
    • pp.171-185
    • /
    • 1990
  • In order to measure the shape deformation of seat surfaces, an indentation measurement mat was devised. The 50cm * 50 cm mat containing small polyethylene beads were made using two sheets of polyurethane film. The indentation measurement mat was shaped by vacuuming between the subject and the testing seat. This method showed less than 5mm of deformation measurement error. Deformation of CADILLAC and MAXIMA seats were compared to demonstrate usefulness of the new method.

  • PDF

Study on the Elastic Characteristics of Living Cells using Atomic Force Microscope Indentation Technique

  • Kwon Eun-Young;Kim Young-Tae;Kim Dae-Eun
    • KSTLE International Journal
    • /
    • 제7권1호
    • /
    • pp.10-13
    • /
    • 2006
  • In this work, imaging and study of elastic property of the living cell was performed. The motivation of this work was to seek the possibility of exploiting Young's modulus as a disease indicator using Atomic Force Microscope (AFM) and also to gain fundamental understanding of cell mechanics for applications in medical nanorobots of the future. L-929 fibroblast adherent cell was used as the sample. Imaging condition in cell culturing media environment was done in very low speed ($20{\mu}m/ s$) compared to that in the ambient environment. For measuring the Young's modulus of the living cell, AFM indentation method was used. From the force-distance curve obtained from the indentation experiment the Young's modulus could be derived using the Hertz model. The Young's modulus of living L-929 fibroblast cell was $1.29{\pm}0.2$ kPa.

연속압입시험법을 이용한 원전구조물의 잔류응력 평가를 위한 접촉깊이의 보정 (Calibration of Contact Depth for Evaluating Residual Stress using Instrumented Indentation Testing)

  • 김영천;강승균;안희준;김광호;권동일
    • 한국압력기기공학회 논문집
    • /
    • 제7권1호
    • /
    • pp.41-47
    • /
    • 2011
  • Residual stress is the key parameter for reliability and lifetime assessment because it can reduce the fatigue strength and fracture properties of industrial structures. Recently, instrumented indentation testing (IIT) has been widely used for evaluating it, since it does not need specific specimen and time-consuming procedure. However, conventional Oliver-Pharr method, which is used for calibrating contact depth to analyze indentation load-depth curve, cannot estimate plastic pile-up between indenter and surface of specimen. Here, we introduce f parameter which is the ratio of contact depth and maximum depth, to consider pile-up height. And, its application for evaluating residual stress of weldment is introduced.

압자압입시험에 의한 이종재료 접합층의 계면인성 평가 (Evaluation of Apparent Interface Toughness of Composites Layers by Indentation Test)

  • 송준희;김학근;임재규
    • 대한기계학회논문집A
    • /
    • 제26권10호
    • /
    • pp.2089-2095
    • /
    • 2002
  • Ceramic/metal composites have many attractive properties and great potential fur applications. Interfacial fracture properties of different layered composites are important in material integrity. Therefore, evaluation of fracture toughness at interface is required in essence. In this study, the mechanical characteristics for interface of ceramic/metal composites were investigated by indentation test of micro-hardness method. Apparent interfacial toughness of TBC system could be determined with a relation between the applied load and the length of the crack formed at the interface by indentation test.