• Title/Summary/Keyword: incineration facilities

Search Result 95, Processing Time 0.026 seconds

The Development of N2O Emission Factor at Killn Type Pyrolysis Melting Facility (외열킬른형 열분해용융시설의 N2O 배출계수 개발)

  • Yun, Hyun-Ki;Lee, Dae Kyeom;Cho, Changsang;Kang, Seongmin;Yoon, Young joong;Jeon, Youngjae;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.8 no.3
    • /
    • pp.231-237
    • /
    • 2017
  • In this study, the $N_2O$ emission factor of the facility was developed by measuring the kiln type pyrolysis melting facility. This used PAS (Photoacoustic Spectroscopy) method and measured the $N_2O$ emission concentration. From March 2016 to April 2016, it was measured over a total of two times and $N_2O$ concentrations were measured continuously for 24 hours using a 24 hour continuous measuring instrument (LSE-4405). The measured $N_2O$ emission concentration of the pyrolysis melting facility was 0.263 ppm on average and the emission concentration distribution in the range of 0.013~0.733 ppm was obtained. Therefore, the $N_2O$ emission factor of the kiln-type pyrolysis melting facility was estimated to be $0.829gN_2O/ton$-Waste. As a result of comparing the $N_2O$ emission factor of the thermal kiln type pyrolysis melting facility and the previous study, previous studies were about 18 times higher. It is estimated that this is due to the difference of furnace temperature, oxygen concentration and denitrification facilities. It is considered that the study of the emission factor of pyrolysis melting facility is an important factor in improving the credibility of greenhouse gas inventory in waste incineration sector.

Evaluation of Performance Index for Optimization of Food Waste Treatment and Recovery Facility (음식물류폐기물 자원화시설 최적화를 위한 이행지표 평가)

  • Kim, Jong-Hwan;Park, Joon-Seok;Phae, Chae-Gun
    • Clean Technology
    • /
    • v.22 no.3
    • /
    • pp.181-189
    • /
    • 2016
  • This research was performed to evaluate the food waste recovery facility using optimization performance index. In 2014, the generated amount of food waste occupied approximately 27% in total municipal solid waste. The 97.2% of the food waste was recycled and the others were treated through landfill and incineration in the portion of 0.9% and 1.9%, respectively. In food waste recovery facilities of year 2014, the composting and feed facilities were 49.5% and 22.9%, respectively. The feed facility showed higher scores in all technological, environmental, and especially economical evaluations than those of composting facility. As results of overall optimization performance index, the feed facility has higher score of 61.5 than 52.7 of composting facility. It was demonstrated that the feed facility has the advantage, compared with the composting facility.

A Study of Cold Flow Characteristics of a Flue Gas Recirculation Burner using Coanda Nozzles (코안다 노즐을 이용한 배기가스 재순환 버너의 냉간 유동 특성에 관한 연구)

  • Ha, Ji Soo;Park, Chan Hyuk;Shim, Sung Hun;Jung, Sang Hyun
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.152-158
    • /
    • 2016
  • Nitrogen oxide is generated by the chemical reaction of oxygen and nitrogen in higher temperature environment of combustion facilities. The NOx reduction equipment is generally used in the power plant or incineration plant and it causes enormous cost for the construction and maintenance. The flue gas recirculation method is commonly adopted for the reduction of NOx formation in the combustion facilities. In the present study, the computational fluid dynamic analysis was accomplished to elucidated the cold flow characteristics in the flue gas recirculation burner with coanda nozzles in the flue gas recirculation pipe. The inlet and outlet of flue gas recirculation pipes are directed toward the tangential direction of circular burner not toward the center of burner. The swirling flow is formed in the burner and it causes the reverse flow in the burner. The ratio of flue gas recirculation flow rate with the air flow rate was about 2.5 for the case with the coanda nozzle gap, 0.5mm and it was 1.5 for the case with the gap, 1.0mm. With the same coanda nozzle gap, the flue gas recirculation flow rate ratio had a little increase when the air flow rate changes from 1.1 to 2.2 times of ideal air flow rate.

Research on the Actual State of Environmental Disease and Health Education at Middle and High School Students (일 지역 중.고등학생들의 환경성 질환 및 보건교육 실태 조사)

  • Jung, Jong-Hyeon;Moon, Ki-Nai;Seo, Bo-Soon;Kim, Chang-Tae;Lee, Jae-Hong
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.12 no.3
    • /
    • pp.65-87
    • /
    • 2011
  • Objectives: The purpose of this study was to perform basic study on environmental and respiratory diseases in Ulsan and vicinities. Also, this study evaluated the actual state of environmental disease and health education at middle and high schools in Ulsan and surroundings. Methods: For this study, we conducted a survey on the health of the general public, environmental effects, and investigated the characteristics of environmental disease, health and hygiene education, etc. The populations of this study were middle and high school students in Ulsan, Korea. This study investigated the knowledge of environmental disease and health education at schools in Ulsan and vicinities from November 2009 to December 2009. All statistical calculations were performed with Statistical Package for Social Sciences (SPSS) for Windows, and gained the following results by implementing Frequency Analysis, Cross-tabulation Analysis and ANOVA. Results: As more and more environmental diseases are increased, the interest of the people has been increasing on this. The incidence rates of asthma and atopy were represented the top 25% of the country in Korea. The source of heavy metal, PAHs and VOCs in Ulsan includes the Petrochemical Complex at Nam-gu and Ulju-gun, the Nonferrous Metal Industrial Complex at Onsan-eup, Ulju-gun, and the Heavy Industrial Complex at Dong-gu and Buk-gu. Especially, there are a number of fossil fuel combustion facilities such as waste incineration plants and boilers at Nam-gu and the Onsan Industrial Complex. It may help greatly to investigate the characteristics of environmental pollutants such as environmental air pollutant and indoor contaminant to better manage the local student's health. Conclusions: It has been revealed that the hazardous chemicals and environmental contaminants are main substances of cause for asthma, atopy, dermatitis, and allergy disease. Therefore, through with collecting basic data such as environmental disease of inhabitants, health education, conscious and knowledgeable level in parents of students and students, We have to exert to improve knowledge and prevention with health life in school through development of health education program systematically for preventing of environmental disease.

  • PDF

Mercury Level in Hair of Primary School Children in Korea and China

  • Park, Hee-Jin;Kim, Dae-Seon;Moon, Jeong-Suk;Yang, Won-Ho;Son, Bu-Soon
    • Molecular & Cellular Toxicology
    • /
    • v.4 no.3
    • /
    • pp.235-245
    • /
    • 2008
  • Exposure to mercury was assessed in 125 Korean (Gwangju and Busan) and 373 Chinese primary school students (Xinguang village, Goumen town) using hair mercury analysis from November 2006 to September 2007. The geometric mean concentration of mercury was higher among Korean children with recording 0.73 ${\mu}g$/g, compared to Chinese children of 0.12 ${\mu}g$/g, which indicated statistically difference (P<0.01). The mean concentration of Korean children living near incineration facilities was higher by recording 0.76 ${\mu}g$/g while the average concentration of their counterpart in Korea reached 0.69 ${\mu}g$/g. In case of Chinese children, those who are living near power plants showed higher level with posting 0.16 ${\mu}g$/g while the others recorded 0.10 ${\mu}g$/g (P<0.01). Intake of fish was found to be related to hair mercury level. In case of Korean children, those with high fish intake recorded 0.79 ${\mu}g$/g in terms of the geometric mean concentration while the others with low fish intake posted 0.61 ${\mu}g$/g. Among Chinese children, those who often eat fish recorded 0.13 ${\mu}g$/g compared to the others with low fish intake of 0.11 ${\mu}g$/g. On the other hand, amalgam dental fillings have limited influence on mean hair mercury level. As for vaccination, within a month of vaccination, the geometric mean concentration of Korean children reached 0.76 ${\mu}g$/g, and in case of 15 days after injection, the level was 1.20 ${\mu}g$/g. In China, the level of children at one month after receiving injection stood at 0.15 ${\mu}g$/g while the level within 15 days was 0.13 ${\mu}g$/g. Multiple regression analysis showed that BMI, passive smoking, and fish consumption are closely related to hair mercury level among the Korean subjects. In China, hair mercury level was affected by age, location, passive smoking, fish consumption, and vaccination. Explanatory power was 21.6% with $R^2$=0.216.

Characteristics of Trace Element Concentrations in Dust by Facilities and Areas in Daegu, Korea (대구지역 축적먼지 중 미량원소성분의 시설별 및 지역별 농도분포)

  • Song, Hee-Bong;Do, Hwa-Seok;Kwak, Jin-Hee;Kim, Jong-Woo;Kang, Jae-Hyoung;Phee, Young-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.3
    • /
    • pp.287-295
    • /
    • 2010
  • Dust samples have been collected from streets, schools, subway stations and households in Daegu metropolitan city. Samples were sieved through a 100 ${\mu}m$ mesh and the concentration of 14 elements have been determined using by ICP after acid extraction. Results showed that Ca, Fe, K, Mg, Mn, Na and V were influenced by natural sources while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. In particular, school dust had higher levels of Ca and Pb and subway station dust had higher levels of Cu and Zn. The percentage composition of chemicals from subway stations, households, and schools were remarkably higher in components from anthropogenic sources than that from streets. It is well recognized that anthropogenic sources were affected by indoor dust. Results of pollution index of hazardous heavy metals indicated that schools, households, and subway stations were more contaminated than streets and urban areas typically had higher pollution index than rural areas. The correlation analysis among trace elements seem to suggest that there were correlations between components of soil/road dust resuspension, and components of waste incineration and fuel combustion.

Distribution of Persistent Organic Pollutants (POPs) in Different Sizes of Particles in the Ambient Air of the Pyeongteak Area (평택지역 대기 중 먼지 입경별 잔류성유기오염물질 분포특성 연구)

  • Kim, Dong-Gi;Woo, Jung-Sik;Kim, Yong-Jun;Jung, Hye-Eun;Park, Ju-Eun;Cho, Duck-Hee;Moon, Hee-Chun;Oh, Jo-Gyo
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.192-203
    • /
    • 2020
  • Objectives: The concentration distributions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), dioxin-like polychlorinated biphenlys (dl-PCBs), and polycyclic aromatic hydrocarbons (PAHs) in fine particles were investigated to provide basic data on POP behavior and composition analysis. Methods: The concentrations of PCDD/Fs, dl-PCBs, and PAHs by particle size were evaluated for TSP, PM10, and PM2.5. Also, fine dust component analysis and factor analysis were performed to identify the source of PCDD/Fs. Results: The particle size distribution was found to account for 24.3% of >10 ㎛, 14.5% of 2.5-10 ㎛, and 61.2% of <2.5 ㎛. The average contributions of coarse particles (>2.5 ㎛) and fine particles (<2.5 ㎛) were PCDD/Fs 67%, dl-PCBs 66%, benzo (a) pyrene 83% and PAHs 84%, and the contributions of fine particles (<2.5 ㎛) were higher than coarse particles (>2.5 ㎛). However, the contributions of coarse particles increased in April to September with higher temperatures, while those of fine particles increased in February to March with lower temperatures. Conclusions: Low chlorinated (4Cl-5Cl) PCDD/Fs were more adsorbed compared to coarse particles due to the influence of pollutant migration from particulate to gas phase according to temperature rise, whereas high chlorinated (6Cl-8Cl) PCDD/Fs were more adsorbed compared to fine particles. PCDD/Fs sources were assessed to be major sources of emissions, such as incineration facilities and/or open burning.

SRF Conversion Potential of Biomass and Mixed Plastic Waste Generated in D City (D시 내에서 발생하는 바이오매스 및 폐플라스틱 혼합 폐기물의 SRF 전환 포텐셜 분석)

  • Yang, Han-Sol;Kim, Ki-Kwang;Lim, Chae-Wook;Hyun, Jae-Hyuk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.3
    • /
    • pp.55-61
    • /
    • 2018
  • This study evaluated if the selected samples meets the Solid Refuse Fuel quality criteria in Korea. Biomass and plastic wastes generated in D City were mixed in diverse ratio. When the biomass content was about 40%, the moisture content was close to the SRF criteria and was measured to be 9.8%. The ash contents were analyzed up to 4.19%, and the lower calorific values based on Steuer, Dulong Equation and Bomb Calorimeter were at least 4,851, 4,181 and 3,847 kcal/kg, respectively. As a result of the elemental analysis, sulfur and chloride content were measured up to 0.05%. Those values satisfied the SRF criteria. Also, heavy metals(Hg, Cd, Pb, As) were analyzed to be below the SRF criteria. This makes it possible to use efficiently the wood byproducts abandoned in the woods, and the physical properties of wood being weak to moisture can be supplemented with plastics. Consequently, if plastic and biomass were well mixed and made into SRF, it would overcome the problem of shortening the life span of incineration facilities due to the high temperature of plastic wastes in the incinerator.

The Study of Preparation of Block Using Wastewater Sludge of Petrochemical Factory (석유화학공장 폐수슬러지를 이용한 벽돌제조 연구)

  • Hu, Kwan;Lu, Juk-Yong;Wang, Seung-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.2
    • /
    • pp.66-73
    • /
    • 2003
  • To investigate the availability of solidified wastes as resource, wastewater sludge, waste gypsum and fly ash were mixed and the results with various mixing ratios are as follows. Compressive strength turned out to be increasing as the amount of waste gypsum increases, keeps longer curing inhibition, and higher forming Pressure under the conditions of waste gypsum/sludge ratio 0.31-0.45, and 0.9kg cement as 15% and 1.2kg cement as 20% of total amount. Solidified agent under the fly ash/sludge ratio 0.45, 0.6, compressive strength seemed to be higher than standard one which means solidified wastes with these conditions could be applicable in real life. These results inform that concentrations of the leachate $Cr^{+6}$, Cu, Zn, Cd, Pb solidified matrix, containing low concentration of heavy metal, were cured with/without enough time it still will cause adverse effect on nature environment and application of heavy metal sequester must be needed to reuse industrial wastes from incineration plant solidified matrix. Total cost price, when considering manufacturing capability of the facilities for resourcerizing as 18,000ton was presented 678,664,000 won, as it were, manufacturing cost price was 37,704 won per ton. The results as above has shown that it's possible to use the mixture of waste gypsum/sludge, fly ash/sludge, cement, additions, and solidification matter as substitute of materials like brick, block, interlocking which has proper compressive strength of KS L 5201 and KS F 4004.

  • PDF

Investigation on Economical Feasibility for Energy Business of Waste Water Sludge Discharged in 'A' Industrial Complex (A-산업단지 발생 슬러지의 에너지화를 위한 경제성 검토)

  • Byun, Jung-Joo;Lee, Kang-Soo;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.4
    • /
    • pp.61-74
    • /
    • 2012
  • Industrial complexes in Korea have been vigorously established by economic development plan and development policy of industry in 1960s. Recently, Korean government has promoted Eco Industrial Park (EIP) project to recycle by-products and wastes in industrial park In this study, we analyzed the physical and chemical properties for the sludges discharged from A industrial complex. And we investigated the economic feasibility and environmental impact of sludge to energy facilities. The analysis results indicated that the petrochemical industry were 92% in sludge production, the highest treatment amount was landfill, followed by incineration and recycling and then ocean disposal. Wastewater sludge and process sludge samples are collected and analyzed to use as basic data on economic feasibility and environmental impact. Weighted average heating value of sludge samples was 3,891kcal/kg. Based on this data, installation and operation costs, operation returns of operating the drying facility are estimated, compared with cogeneration facility. And this study examines how the payback period of each simulation(total 8 case) with the important parameter changes. As a result, it was found that what needs the shortest payback period is 3years with connection of drying facility and cogeneration facility based on the government's financial subsidy system.