• Title/Summary/Keyword: in-process detection

Search Result 3,550, Processing Time 0.035 seconds

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Acceleration of Early Embryonic Development by Induction of Acrosome Reaction in Intracytoplasmic Sperm Injection (세포질내 정자주입술 시행시 정자의 첨체반응이 수정란의 초기 발생과 임신율에 미치는 영향)

  • Lim, Y.J.;Lee, D.R.;Lee, J.E.;Kim, H.J.;Paik, H.R.;Yoon, H.S.;Shim, H.N.;Cho, J.H.;Roh, S.I.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.3
    • /
    • pp.311-318
    • /
    • 1997
  • Bypassing acrosome reaction and fusion process in intracytoplasmic sperm injection(ICSI), most of injected spermatozoa still contain intact acrosome contents and plasma membrane. It Is not known yet what acrosome contents and plasma membrane of spermatozoa have effect on the development of embryo. For further understanding of fertilization process after ICSI, we studied the time of pronucleus formation, disappearance and first cleavage in human zygote, and pregnancy rate in relation to acrosome reaction rate of spermatozoa after ICSI. Seventy cycles undergoing ICSI program were randomly selected. Sperm suspension from 38 cycles were treated 50% human follicular fluid(hFF) for 3 hours in order to induce acrosome reaction, others were not treated as control. Acrosome reaction in hFF treated and non-treated group was assessed by fluorescein isothiocyanate(FITC)-conjugated Arachis hypogea(PNA) and Pisum sativum agglutinin(PSA). Oocytes were classified into 'good' and 'poor' according to their morphology. After ICSI, fertilization of oocytes were assessed by detection of two pronuclei at 16 hours. The pronuclei disappearance and first cleavage of zygotes were observed at 24 hours, and then embryos were transferred to uterus after culture for 72 hours. The rate of acrosome reaction of spermatozoa in hFF treated group was significantly higher than that in control(p<0.01). Fertilization rates of good oocytes were not different both control and hFF treated group(81.3%(174/206) vs. 72.1%(102/130)). But, in poor oocytes, the fertilization rates in hFF treated group(72.1%(149/183)) were increased compared than those of control group (63.6%(98/140), p<0.01). In either good or poor oocytes, the rates of pronuclei disappearance in hFF treated-spermatozoa injected oocytes were higher than control (59.1%(103/174), 56.4%(84/149) vs. 32.4%(33/102), 37.8%(37/98), p<0.01). Also, the rates of thirst cleavage were increased in hFF treated group (31%(54/174), 24.1%(36/149)) compared than those of control group (10.8%(11/102), 13.2%(13/98), p<0.01). The pregnancy rates of hFF treated group (42.1%(16/38)) were slightly higher than control group (28.1%(9/32), p>0.05). But, the pregnancy rate of group which possessed more than one cleavaged zygote at 24 hours was higher than group which did not (45.2%(19/42) vs. 21.4%(6/28), p<0.05). From these results, the development of zygotes were faster in higher acrosome reacted sperm group than lower acrosome reacted sperm group after ICSI. Our results may be explained that acrosomal membrane and plasma membrane are easily detached from spermatozoa in acrosome reacted spermatozoa compared with acrosome intact sperm in the cytoplasm of oocyte during pronuclear formation. We conclude that the injection of acrosome reacted spermatozoa will increase the pregnancy rate as they can induce fast embryonic development in ICSI.

  • PDF

Effect of Okadaic Acids (OA) on Nuclear Maturation and Mitochondrial Activity of Hanwoo COCs during in vitro Maturation (소 난구복합체의 체외성숙시 Okadaic Acid (OA)가 핵성숙 및 Mitochondria 활성에 미치는 영향)

  • Choi S. H.;Han M. H.;Cho S. R.;Kim H. J.;Choe C. Y.;Son D. S.;Kim Y. K.;Lee M. H.;Jeoung Y. G.;Chung Y. H.
    • Journal of Embryo Transfer
    • /
    • v.20 no.3
    • /
    • pp.303-309
    • /
    • 2005
  • This study was conducted to examine the effects of OA on metaphase of meiosis II and the mitochondrial activity of cytoplasm in bovine cumulus oocytes complexes(COCs) during in vitro maturation. Hanwoo COCs were collected from the slaughterhouse cow ovaries and matured in TCM199 supplemented with $0.1\%$ PVA, 0.2 uM, 2 uM, 20 uM OA for the maturation rate of OA concentration. For the maturation effects between OA and cycloheximide(CX), COCs were matured in TCM199 with 25 ug/mL CX, 25 ug/mL CX (6 hrs culture) plus 2 uM OA or 2 uM OA only at a atmosphere $5\%\;CO_2,\;95\%$ air $39^{\circ}C$ for 6, 12, 24 hrs. To evaluate the nuclear types of matured COCs, cumulus cells were removedby $0.5\%$ hyaluronidase sol. and oocytes were fixed in 1:3 acetic acid ethyl alcohol for 30 sec. and then stained with $0.1\%$ basic Fuchsin sol. For the detection of fluoriscent intensity (FI) of matures oocytes, cumulus cells were removed same as performed above and were stained with 20 nM mite tracker for 20 min. at $39^{\circ}C$. Mitochondrial activity of FI in matured oocytes was imaged by laser conforcal microscopy (Fluoview, Olympus, Japan) and were measured scanned face on 5 um from median to endpoint of oocytes. Statical analysis of nuclear types observed the three replicates was carried out with ANOVA and Fisher's protected least significant difference test using the STATVIEW program. FI of matures oocytes was compared the multiples of the least intensity among the measured oocytes. Maturing in TCM199 supplemented with $0.1\%$ PVA, 0.2 uM, 2 uM, 20 uM OA, metaphase B were showed 72.0, 50.0, 70.0, $68.8\%$, respectively and there were different significant(p<0.05). In the case of treatment with OA and CX, metaphase were $73.8\%,\;8.2\%,\;45.5\%,\;73.7\%$ in $0.1\%$ PVA-TCM199, 25 ug/mL CX, 25 ug/mL CX plus OA or 2uM OA only, respeclively. FI was revealed the increasing tendency during the process of maturation. Whereas FI in CX was decreased about 3 times compared to the other treatments of 6 hrs maturation. We conclude that OA regulates bovine COCs maturation and induces the mitochondrial activity during the process of maturation.

A Study on the Sanitation Condition for Products of Powdered Raw Grains and Vegetables (곡류 가공품 등의 위생실태에 관한 조사 연구)

  • Cho, Bae-Sick;Gang, Gyung-Lee;Lee, Hyang-Hee;Ha, Dong-Ryong;Kee, Hye-Young;Seo, Kye-Won;Kim, Eun-Sun;Park, Jong-Tae
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.4
    • /
    • pp.273-278
    • /
    • 2007
  • Recently, the demand for the powdered products to process raw grains and vegetables has been expanded, and the growth possibility of their fields(markets) in the future will be highly valued with the westernization of living environment and the change of the dietary life. We have bought and analyzed the 111 products of raw grains and vegetables from the large-sized marts, markets and internet orders from March to October 2006. The rate of moisture content was $1.7{\sim}12.5%$. We also found out that the foods over 10% moisture content was 8 of those samples we bought or collected. Their ash rates were averagely $0.3{\sim}8.6%$. The number of those foods that the alien substances were detected was 2. The tar pigments, artificial sweeteners and sulfur dioxides of components that contained food additives were not detected. Each detection range of Cadmium, Lead and Arsenic of the injurious heavy metals was non-detectable $(nd){\sim}0.55,\;nd{\sim}4.52,\;nd{\sim}0.10mg/kg$, while the average detection content were 0.08, 0.48, 0.01 mg/kg. By investigating the contamination degree of the microflora, we discovered that the number of the aerobic plate count, B. cereus over 1,000 cfu/g and C. perfringens over 100 cfu/g was 36 (32.4%), 9 (8.1%) and zero, and that the whole sanitation condition of the products of powdered raw grains and vegetables circulated in the market was not so good.

Deriving geological contact geometry from potential field data (포텐셜 필드 자료를 이용한 지짙학적 경계 구조 해석)

  • Ugalde, Hernan;Morris, William A.
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.1
    • /
    • pp.40-50
    • /
    • 2010
  • The building process of any geological map involves linking sparse lithological outcrop information with equally sparse geometrical measurements, all in a single entity which is the preferred interpretation of the field geologist. The actual veracity of this interpretative map is partially dependent upon the frequency and distribution of geological outcrops compounded by the complexity of the local geology. Geophysics is commonly used as a tool to augment the distribution of data points, however it normally does not have sufficient geometrical constraints due to: a) all geophysical inversion models being inherently non-unique; and b) the lack of knowledge of the physical property contrasts associated with specific lithologies. This contribution proposes the combined use of geophysical edge detection routines and 'three point' solutions from topographic data as a possible approach to obtaining geological contact geometry information (strike and dip), which can be used in the construction of a preliminary geological model. This derived geological information should first be assessed for its compatibility with the scale of the problem, and any directly observed geological data. Once verified it can be used to help constrain the preferred geological map interpretation being developed by the field geologist. The method models the contacts as planar surfaces. Therefore, it must be ensured that this assumption fits the scale and geometry of the problem. Two examples are shown from folded sequences at the Bathurst Mining Camp, New Brunswick, Canada.

A Power MOSFET Driver with Protection Circuits (보호 회로를 포함한 전력 MOSFET 구동기)

  • Han, Sang-Chan;Lee, Soon-Seop;Kim, Soo-Won;Lee, Duk-Min;Kim, Seong-Dong
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.2
    • /
    • pp.71-80
    • /
    • 1999
  • In this paper, a power MOSFET driver with protection circuits is designed using a 2${\mu}m$ high-voltage CMOS process. For stable operations of control circuits a power managing circuit is designed, and a voltage-detecting short-circuit protection(VDSCP) is proposed to protect a voltage regulator in the power control circuit. The proposed VDSCP scheme eliminates voltage drop caused by a series resistor, and turns off output current under short-circuit state. To protect a power MOSFET, a short-load protection, a gate-voltage limiter, and an over-voltage protection circuit are also designed A high voltage 2 ${\mu}m$ technology provides the breakdown voltage of 50 V. The driver consumes the power of 20 ~ 100 mW along its operation state excluding the power of the power MOSFET. The active area of the power MOSFET driver occupies $3.5 {\times}2..8mm^2$.

  • PDF

AVO analysis using crossplot and amplitude polynomial methods for characterisation of hydrocarbon reservoirs (탄화수소 부존구조 평가를 위한 교차출력과 진폭다항식을 이용한 AVO 분석)

  • Kim, Ji-Soo;Kim, Won-Ki;Ha, Hee-Sang;Kim, Sung-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.1
    • /
    • pp.25-41
    • /
    • 2011
  • AVO analysis was conducted on hydrocarbon-bearing structures by applying the crossplot and offset-coordinate amplitude polynomial techniques. To evaluate the applicability of the AVO analysis, it was conducted on synthetic data that were generated with an anticline model, and field data from the hydrocarbon-bearing Colony Sand bed in Canada. Analysis of synthetic data from the anticline model demonstrates that the crossplot method yields zero-offset reflection amplitude and amplitude variation with negative values for the upper interface of the hydrocarbon-bearing layer. The crossplot values are clustered in the third quadrant. The results of AVO analysis based on the coefficients of the amplitude polynomial are similar to those from the crossplots. These well correlated results of AVO analysis on field and synthetic data suggest that both methods successfully investigate the characteristics of the reflections from the upper interface of a hydrocarbon-bearing layer. Analysis based on the incident-angle equation facilitates the application of various interpretation methods. However, it requires the conversion of seismic data to an incident angle gather. By contrast, analysis using coefficients of the amplitude polynomial is cost-effective because it allows examining amplitude variation with offset without involving the conversion process. However, it warrants further investigation into versatile application. The two different techniques can be complement each other effectively as AVO-analysis tools for the detection of hydrocarbon reservoirs.

An Efficient Real-Time Image Reconstruction Scheme using Network m Multiple View and Multiple Cluster Environments (다시점 및 다중클러스터 환경에서 네트워크를 이용한 효율적인 실시간 영상 합성 기법)

  • You, Kang-Soo;Lim, Eun-Cheon;Sim, Chun-Bo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2251-2259
    • /
    • 2009
  • We propose an algorithm and system which generates 3D stereo image by composition of 2D image from 4 multiple clusters which 1 cluster was composed of 4 multiple cameras based on network. Proposed Schemes have a network-based client-server architecture for load balancing of system caused to process a large amounts of data with real-time as well as multiple cluster environments. In addition, we make use of JPEG compression and RAM disk method for better performance. Our scheme first converts input images from 4 channel, 16 cameras to binary image. And then we generate 3D stereo images after applying edge detection algorithm such as Sobel algorithm and Prewiit algorithm used to get disparities from images of 16 multiple cameras. With respect of performance results, the proposed scheme takes about 0.05 sec. to transfer image from client to server as well as 0.84 to generate 3D stereo images after composing 2D images from 16 multiple cameras. We finally confirm that our scheme is efficient to generate 3D stereo images in multiple view and multiple clusters environments with real-time.

A Study on the Threats of Wiretapping and Effective Security Management Strategies (도청보안의 취약성 및 개선방안에 관한 연구)

  • Lee, Young Ho;Choi, Kyung Cheol;Woo, Sang Yeob
    • Korean Security Journal
    • /
    • no.62
    • /
    • pp.347-367
    • /
    • 2020
  • Rapid advancement of technology in today's society has allowed for easy access and use of data, promoting the process of informationization. Along with the merits of such development, unintended consequences of security risks involving wiretapping have been increasing as well. The security threats posed by wiretapping technology must be addressed by every organization and individual, as it could be used to leak confidential information about the nation's security, military and diplomatic strategies, industrial technologies, and personal information. Despite increasing threats stemming from the surrounding nations using advanced wiretapping technology, there is a lack of awareness at the government level, and the existing security measures for detecting and counteracting the wiretapping equipment are ineffective. In this research, the authors offered technical suggestions for improving the security strategies against the threats of wiretapping and information leakage by conducting a content analysis. The authors suggested the units of an agency be assigned a security grade based on its importance, and that adequate security equipment should be operated according to the grade. For instance, around-the-clock surveillance is recommended for grade-1 facilities, and portable wiretapping equipment detectors should be used to protect conference rooms and other key sites.

Hazard Analysis of Autonomous Vehicle due to V2I Malfunction (V2I 오작동에 의한 자율주행자동차의 위험성 분석)

  • Ahn, Dae-ryong;Shin, Seong-geun;Baek, Yun-soek;Lee, Hyuck-kee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.6
    • /
    • pp.251-261
    • /
    • 2019
  • The importance of autonomous driving systems that utilize V2X services such as V2V(Vehicle to Vehicle) and V2I(Vehicle to Infrastructure) for safer and more comfortable driving is increasing with the recent development of autonomous vehicles. Partly autonomous vehicles based on environmental sensors have limitations for predicting and determining areas beyond the recognition distance of the mounted sensors and in response to atypical objects that are difficult to detect. Therefore, it is important to utilize the V2X service to improve the limit of sensor detection performance and to make driving safer and more comfortable. However, there may be an accident risk of autonomous vehicles due to incorrect information provided by V2X. Thus, the application of technology to prevent this needs to be considered. In this pater, we used the ISO-26262 Part3 Process and performed HARA (Hazard Analysis and Risk Assessment) to derive the risk sources of autonomous vehicles due to V2I malfunctions by using the communication between vehicles and infrastructure among V2X. We also developed ASIL ratings based on the simulations and real vehicle tests of the malfunctions of major cases of usnig V2I.