• Title/Summary/Keyword: in-band 방식

Search Result 966, Processing Time 0.03 seconds

Design of An Amplifier using DGS Block (DGS 방식 DC Block을 이용한 증폭기의 설계)

  • 이경희;정용채
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.3
    • /
    • pp.432-438
    • /
    • 2001
  • In this paper, after applying Defected Ground Structure(DGS) to DC block, changes of gap and length of λ/4 coupled line are investigated by EM simulation and fabrication. As a result, on condition of the same output with the case using typical DC block, the gap between λ/4 coupled line is widen from 0.1 mm to 0.46 mm by 0.36 mm and the length of λ/4 coupled line gets shorter from 17.7 mm to 13.2 mm by 4.5 mm. Also three type power amplifiers using blocking capacitor, typical DC block and DGS DC block are fabricated and investigated. At first, when S parameter characteristics of each amplifier are considered at frequency band of 3.2 +-0.O5 GHz, every amplifier has similar characteristics of gain and S parameter. Second when the output power of amplifiers is 25 dBm after putting CW signal of 3.2 GHz into three type amplifiers, the difference of dominant signal and 2nd harmonic signal using blocking capacitor, typical DC block and DGS DC block is each -44.83 dBc, -66.84 dBc and -64.33 dBc. Therefore harmonic characteristics of amplifiers using typical DC block and DGS DC block is almost same.

  • PDF

Integrated Photonic Microwave Bandpass Filter Incorporating a Polymer Microring Resonator (폴리머 마이크로링 공진기를 이용한 광학적 마이크로웨이브 대역통과 필터)

  • Chin, Won-Jun;Kim, Do-Hwan;Song, Ju-Han;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.469-475
    • /
    • 2005
  • An integrated photonic microwave bandpass filter has been proposed and demonstrated incorporating a coherently coupled microring resonator in low-loss polymers. The proposed device may feature compact site, simple structure, tuning via the thermooptic and electrooptic effect, and flexible integration with other electrical and optical devices. The resonator was designed to have an extremely small bandwidth so that it could be used to selectively pass the optical signal carrying the microwave signal to attain efficient bandpass filtering. We made and tested two resonators with a single ring and double rings, and performed a theoretical fitting of their measured transfer curves to predict the performance of the microwave filters based on them precisely. It was found that as the number of the rings used for the resonator increases, the bandwidth gets smaller, the rolloff sharper, and the band rejection higher. Finally our filter exhibited the center frequency of 10GHz, the 3-dB bandwidth of 1.0GHz, the corresponding quality (Q) factor of 10, and the rejection outside of the passband of more than 25dB.

Electroencephalographic Changes Induced by a Neurofeedback Training : A Preliminary Study in Primary Insomniac Patients (뉴로피드백 훈련에 의한 뇌파 변화 연구 : 일차성 불면증 환자에 대한 예비 연구)

  • Lee, Jin Han;Shin, Hong-Beom;Kim, Jong Won;Suh, Ho-Suk;Lee, Young Jin
    • Sleep Medicine and Psychophysiology
    • /
    • v.26 no.1
    • /
    • pp.44-48
    • /
    • 2019
  • Objectives: Insomnia is one of the most prevalent sleep disorders. Recent studies suggest that cognitive and physical arousal play an important role in the generation of primary insomnia. Studies have also shown that information processing disorders due to cortical hyperactivity might interfere with normal sleep onset and sleep continuity. Therefore, focusing on central nervous system arousal and normalizing the information process have become current topics of interest. It has been well known that neurofeedback can reduce the brain hyperarousal by modulating patients' brain waves during a sequence of behavior therapy. The purpose of this study was to investigate effects of neurofeedback therapy on electroencephalography (EEG) characteristics in patients with primary insomnia. Methods: Thirteen subjects who met the criteria for an insomnia diagnosis and 14 control subjects who were matched on sex and age were included. Neurofeedback and sham treatments were performed in a random order for 30 minutes, respectively. EEG spectral power analyses were performed to quantify effects of the neurofeedback therapy on brain wave forms. Results: In patients with primary insomnia, relative spectral theta and sigma power during a therapeutic neurofeedback session were significantly lower than during a sham session ($13.9{\pm}2.6$ vs. $12.2{\pm}3.8$ and $3.6{\pm}0.9$ vs. $3.2{\pm}1.0$ in %, respectively; p < 0.05). There were no statistically significant changes in other EEG spectral bands. Conclusion: For the first time in Korea, EEG spectral power in the theta band was found to increase when a neurofeedback session was applied to patients with insomnia. This outcome might provide some insight into new interventions for improving sleep onset. However, the treatment response of insomniacs was not precisely evaluated due to limitations of the current pilot study, which requires follow-up studies with larger samples in the future.

Performance Analysis of a Deep Vertical Closed-Loop Heat Exchanger through Thermal Response Test and Thermal Resistance Analysis (열응답 실험 및 열저항 해석을 통한 장심도 수직밀폐형 지중열교환기의 성능 분석)

  • Shim, Byoung Ohan;Park, Chan-Hee;Cho, Heuy-Nam;Lee, Byeong-Dae;Nam, Yujin
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.459-467
    • /
    • 2016
  • Due to the limited areal space for installation, borehole heat exchangers (BHEs) at depths deeper than 300 m are considered for geothermal heating and cooling in the urban area. The deep vertical closed-loop BHEs are unconventional due to the depth and the range of the typical installation depth is between 100 and 200 m in Korea. The BHE in the study consists of 50A (outer diameter 50 mm, SDR 11) PE U-tube pipe in a 150 mm diameter borehole with the depth of 300 m. In order to compensate the buoyancy caused by the low density of PE pipe ($0.94{\sim}0.96g/cm^3$) in the borehole filled with ground water, 10 weight band sets (4.6 kg/set) were attached to the bottom of U-tube. A thermal response test (TRT) and fundamental basic surveys on the thermophysical characteristics of the ground were conducted. Ground temperature measures around $15^{\circ}C$ from the surface to 100 m, and the geothermal gradient represents $1.9^{\circ}C/100m$ below 100 m. The TRT was conducted for 48 hours with 17.5 kW heat injection, 28.65 l/min at a circulation fluid flow rate indicates an average temperature difference $8.9^{\circ}C$ between inlet and outlet circulation fluid. The estimated thermophysical parameters are 3.0 W/mk of ground thermal conductivity and 0.104 mk/W of borehole thermal resistance. In the stepwise evaluation of TRT, the ground thermal conductivity was calculated at the standard deviation of 0.16 after the initial 13 hours. The sensitivity analysis on the borehole thermal resistance was also conducted with respect to the PE pipe diameter and the thermal conductivity of backfill material. The borehole thermal resistivity slightly decreased with the increase of the two parameters.

A study on the implementation of Medical Telemetry systems using wireless public data network (무선공중망을 이용한 의료 정보 데이터 원격 모니터링 시스템에 관한 연구)

  • 이택규;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.278-283
    • /
    • 2000
  • As information communication technology developed we could check our blood pressure, pulsation electrocardiogram, SpO2 and blood test easily at home. To check our health at ordinary times is able though interlocking the house medical instrument with the wireless public data network This service will help the inconvenience to visit the hospital everytime and will save the individual's time and cost. In each house an organism data which is detected from the human body will be transmitted to the distance hospital and will be essentially applied through wireless public data network The medical information transmit system is utilized by wireless close range network It would transmit the obtained organism signal wirelessly from the personal device to the main center system in the hospital. Remote telemetry system is embodied by utilizing wireless media access protocol. The protocol is embodied by grafting CSMA/CA(Carrier Sense Multiple Access with Collision Avoidance) protocol falling mode which is standards from IEEE 802.11. Among the house care telemetry system which could measure blood pressure, pulsation, electrocardiogram, SpO2 the study embodies the ECC(electrocardiograph) measure part. It within the ECC function into the movable device and add 900㎒ band wireless public data interface. Then the aged, the patients even anyone in the house could obtain ECG and keep, record the data. It would be essential to control those who had a health-examination heart diseases or more complicated heart diseases and to observe the latent heart disease patient continuously. To embody the medical information transmit system which is based on wireless network. It would transmit the ECG data among the organism signal data which would be utilized by wireless network modem and NCL(Native Control Language) protocol to contact through wireless network Through the SCR(Standard Context Routing) protocol in the network it will be connected to the wired host computer. The computer will check the recorded individual information and the obtained ECC data then send the correspond examination to the movable device. The study suggests the medical transmit system model utilized by the wireless public data network.

  • PDF

Study on the establishment of an efficient disaster emergency communication system focused on the site (현장중심의 효율적 재난통신체계 수립 방안 연구)

  • Kim, Yongsoo;Kim, Dongyeon
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.518-527
    • /
    • 2014
  • Our society is changed and diversified rapidly and such tendency is accelerated day after day and has made a lot of problems in the many fields. The important thing we have to recognize is such tendency has a bad effect recently on the safety system in Korea. So it is time to enhance the national safety system and moreover recently Sewol-ho(passenger ship) went down in the sea, it made people remind the importance of national safety system. With this incident, Korean government decided to establish the national safety communication network against the disaster. At this time, I will propose several ideas about the national safety communication network. 1. It must to be established an unified network to contact people who is on a disaster site anytime and anywhere. This is most important element on all disaster sites. 2. PS-LTE technology must to be adopted to the network because it has many advantages including various multimedia services compared to the TETRA in the past. 3. 700MHz is the most efficient band for the network because it has wide cell sites coverage compared to 1.8GHz. 4. Satellite communication system is needed to the network for back-up. 5. It will be effective to adopt Social Media to the communication network system like a Twitter or Facebook for sharing many kinds of information and notifying people of warning message. 6. It can make the network more useful to introduce the latest technology like a sensor network. And Korean government has to improve the system related to the disaster including law and operating organization.